Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹43.8 L+₹3.1 L (7.55%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹44.5 L+₹3.7 L (9.17%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹44.8 L+₹4.1 L (9.98%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹45.9 L+₹5.1 L (12.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Apr 2024, 6:00 pmClosed
GE BRICHGUNJ
GE BRICHGUNJ
REPAIR AND MAINT OF SPLIT AC WINDOW AC REFRIGERATORS DEEP FREEZERS WATER COOLERS FANS GEYSERS AND OTHER ACCESSORIES UNDER GE BRICHGUNJ
2024_MES_646562_1
8463A
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE BRICHGUNJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
22 May 2024
15 Mar 2024
11 Apr 2024
15 Mar 2024
9 Apr 2024
30 Mar 2024
Amount
M&L for charging of refrigerant gas R-404 (a)/R-410 (a) for water cooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed by Engr-in-Charge.
M&L for charging of refrigerant gas R-134 (a) in Refrigerator of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed by Engr-in-Charge.
Taking down storage type water heater of 50 ltrs capacity of any make and any type and disconnecting inlet/outlet pipe connections complete, including dismantling and servicing, leak testing compltely and refixing the same in position with suitable nuts and bolts and connecting inlet/outlet connections including testing and commissioning all as specified and as directed by Engr-in-Charge.
All as per item No 03.00 here in before but water heater of 25 litres capacity
S&F in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Heating element of 2000 watts, 240 volts suitable for existing complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Thermostat element suitable for 25/50 ltrs capacity water heater, suitable for existing complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Geyser "Hot & Cold" PVC pipe line connecting to stop cock off 15mm dia, 450mm length all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of scotch screw 10mm for installation of water heater
Supply and fix in repair of neon bulb red and green in colour for indication of water heater
Supply and fix in repair of top cover of water heater
Supply only bottom cover of water heater
supply and fix in replacement of plug top 15 Amps
Supply and fix in repair of 3 core 1.5sqmm copper cable
M&L for pressure testing the compressor unit including connecting pipe line with nitrogen gas and holding the appropriated pressure for approved period (as per manufactureal instruction) and rectify the leakages by means of welding, soldering/brazing etc for window/splitt type air conditioner/ water cooler/refrigerator of any capacity and make, including testing and commissioning complete all as specified and as directed by Engr-in-Charge.
M&L Repair to voltage stabilizer 5.0/4.0 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed by Engr-in-Charge.
M&L Repair to voltage stabilizer 0.5 to 3 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed by Engr-in-Charge.
S & F in repair of 20 A MCB DB BOX COMBO Plastic Enclosure modular type complete with one MCB, SP, 20 Amps, 240 Volts fixed complete all as specified and as directed.
Supply and fix in repair earthed plug top 20 Amps capacity with sheet metal enclosure etc all as specified and directed.
M & L for AC point sub main wiring with 3 runs (Phase, neutral, earth) of 4 Sq.mm PVC Insulated Unsheathed single core cable, 1100 Volts Grade Multistranded with Copper Conductor drawn through and including PVC Casing and Caping (or) PVC conduit of 20mm dia non metalic rigid with conduit accessories fixed to walls/roofs/floors etc and One run of 4 Sq.mm Single Core Multistranded Copper Conductor as earth continuity conductor all as specified and as directed by Engr-in-Charge.. (Note: 2 runs of 4 Sq.mm & 1 run of 4 Sq.mm earth conductor will be measured as one running metre)
Supply and fix in repair of PVC conduit 20mm for drain out of air conditioner, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 5/8 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 1/2 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 3/8 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 1/4 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed by Engr-in-Charge.
All as per item No 26.00 hereinbefore but exhaust fan of 400/450mm sweep
Supply and fix in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix in repalcement ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed.
Supply and fix in repalcement condensor 4 mfd AC 230 volts 50 cycles, complete all as specified and as directed.
Taking down wall mounted fan of any size/sweep from existing position complete with bladesfrom brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix in repair of ball bearing suitable for wall mounted fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking out and the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the wall mounted fan of size 400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repalcement wall mounted fan covering Net
Supply and fix in repalcement wall mounted fan blade
Supply and fix in repalcement capacitor 2 mfd for wall fan.
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repalcement canopy of ceiling fan, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repalcement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix in repair of ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair of down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix in reapir of fan condensor 2.5 mfd AC 240 volts 50 Hz complete all as specified and as directed.
M&L for servicing of window type air conditioner of 1.5/2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
Dismantling the following unservicable items from window type air conditioner of capacity 1.5/2.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
AC fan motor single phase, 1/5 hp, 1100 rpm, 130 watts, 240 volts
Over load protector
Thremostat
Capacitor 55/ 60 mfd 230 volts
Fan capacitor 5/6 mfd
Starting relay
Blower motor fan blade set
Rubber mounting bush for blower motor
S&F in repairs copper condensor coil suitable for 1.5/2 T Split/window AC complete all as specified and as directed by Engr-in-Charge.
M&L for servicing of split type air conditioner of 2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
M&L for servicing of split type air conditioner of 1.5 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
Dismantling the following unservicable items from split type air conditioner of capacity 1.5/2.0/4.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed Compressor for 1.5 ton split type air conditioner under manufacturers exchange scheme.
Compressor for 2.0 ton split type air conditioner under manufacturers exchange scheme.
Compressor for 4.0 ton split type air conditioner under manufacturers exchange scheme.
Blower motor for 1.5 ton split type air conditioner
Blower motor for 2.0 ton split type air conditioner
Condensor motor
Capacitor for 2.0 ton split type air conditioner, 55/60 mfd 230 volts
Capacitor for 1.5 ton split type air conditioner, 45/50 mfd 230 volts
Fan capacitor 3/4/5 mfd
Starting relay for 1.5/2.0 ton split type air conditioner
PCB Electronic control board for 1.5/2.0 ton split type air conditioner
Insulation rubber hose 12mm for split AC any type
Hand Remote set for 1.5/2.0 ton split type air conditioner
Outer brass valve of size 5/8" for out door unit of split AC 2 ton
Outer brass valve of size 3/8" for out door unit of split AC 2 ton
Outer brass valve of size 1/2" for out door unit of split AC 1.5 ton
Outer brass valve of size 1/4" for out door unit of split AC 1.5 ton
MS Stand for outer unit of split AC 1.5/2 ton capacity.
Expansion valve with capillary for window/split type AC
Dismantling the following unservicable items from water cooler storage type 40/80 and 60/120 ltrs cooling of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme 60/120 Ltrs capacity.
Compressor under manufacturers exchange scheme 40/80 Ltrs capacity.
Fan motor 60/120 ltrs capacity.
Fan motor 40/80 ltrs capacity.
Thermal over load protector 40/80 ltrs capacity.
Starting relay 40/80 and 60/120 ltrs capacity.
Thermostat 40/80 and 60/120 ltrs capacity.
Starting capacitor 80/100 mfd 230 volts
Running capacitor 10 mfd 230 volts
Self closing tap of chromium plated brass, size 15mm
Expansion valve with capillary for water cooler
Condenser coil
Aluminium cooling coil/Freezer coil
Dismantling the following unservicable items from Refrigerator 175 to 220 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Limit Switch
Fan motor
Timer
Bimetal
Expansion valve with capillary for refrigerator
Dismantling the following unservicable items from Refrigerator 280 to 310 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Aluminium cooling coil/Freezer coil
condensor coil
Thermostat
Dismantling the following unservicable items from deep Freezer 200/400 Ltrs capacity of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed Compressor under manufacturers exchange scheme.
starting relay
Thermostat
Starting capacitor for deep Freezer, 80/100 mfd 230 volts
Running capacitor for deep Freezer, 40/60 mfd 230 volts
Taking down unserviceable Split AC 1.5 Ton/2 Ton and deposit E&M store and refixing serviceable unit complete in position all as specified and as directed by Engr-in-Charge.
M&L for charging of refrigerant gas R-22 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed by Engr-in-Charge.
Tropical Refrigeration
MGP Enterprises
SK CONSTRUCTION
DHAKSHNA MOORTHY AND SON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .