SITC of Fire Alarm System at Ground, 2nd and 3rd Floors at PTI Building for MoT, New Delhi.
2025_ITDC_236596_1
ITDC/EM/Fire/PTI/2025
Open Tender
Electrical Works
Works
90 days
PTI Building
As per Tender Documents
19 documents required · 19 mandatory
₹0
₹27,200
Yes
1 Aug 2025
27 May 2025
13 Jun 2025
27 May 2025
12 Jun 2025
27 May 2025
Amount
SITC of 4 Kg ABC Type fire Extinguisher duly ISI marked conforming to IS: 15683:2006, with IS 14609, ISI marked ABC powder complete with squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket, on wall with mounting bracket as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
SITC of 2 kg CO2 type fire Extinguisher ISI marked conforming to IS: 15683. Complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket, with floor stand or wall with mounting bracket as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
SITC of 9 kg CO2 type fire Extinguisher SI marked conforming to IS: 16018. Complete with composite trolley with handle & wheel, operation manual, wheel type release valve, locking arrangement and shut-off valve fitted with delivery hose horn as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
SITC of Clean agent Type fire Extinguisher with necessary accessories 2 Kg ISI marked IS: 15683 filled with HFC 236FAClean Agent Gas. Complete with squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing and Commissioning of Conventional type Fire Alarm Panel shall be running on full digital protocol type Fire Alarm Control Panel. The Panel shall be complete with liquid-crystal display (LCD). LCD Display status and Security events displays. System should be capable to have 4 Zones. The panel shall have the Fire Fighter Touch Screen the system cards shall have ground fault detection and diagnostic LEDs by card. The system shall be polarity insensitive. The panel shall have battery backup of 24 hrs in normal condition and 30 minutes in Alarm condition as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge
Supply, installation, testing and commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
SITC of UL listed conventional Multicriteria detector with Advanced Signal Analysis, Provides enhanced detection light-scattering technology having two optical and two thermal sensors Differentiates between deceptive phenomena and an actual fire (nuisance-alarm avoidance) and complying with NFPA/yellow for trouble and Red for alarm as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of Response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supply, Installation, Testing & Commissioning of Manual Pull Station. Shock and Vibration Resistant, Pull Down Lever Remains Down Until Reset, complete at site as per Direction of Engineer In charge. (M.S. Body)
Supplying and Fixing of 25 mm size, medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of UL listed Hooter with ‘90 DB frequency, 520 Hz square-wave tones Provides six (6) field-configurable audible-tone complete at site as per Direction of Engineer In charge. (M.S. Body)
Supplying and laying for fire alarm system with the following sizes of FRLS insulated copper conductor single core cables in existing surface/recessed M.S. conduit etc. as complete as required.
2 x 1.5 Sq. mm.
2 x 2.5 Sq. mm
Providing and fixing of DLP System for server room consists of 1 Kg FM‐200 fluid ‐HFC‐227ea, DLP Assembly with automatic valve, push in connector for tube, mounting bracket, End of Line adaptor. Linear pneumatic heat Detection Tube with all necessary fittings & supports. A/V Alarm & Low pressure switch for monitoring system activation, complete at site as per Direction of Engineer In charge.
Endeavour Power Services (BID ID -861266)
Soham Sparkle and Silhouette Service (BID ID -860989)
USOP Securiti Technologies Private Limited (BID ID -860808)
DIGITEK FIRE SAFETY PVT LTD (BID ID -861239)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .