Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹52.3 L+₹2.4 L (4.86%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹52.9 L+₹3.1 L (6.14%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹53.7 L+₹3.8 L (7.60%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹55.2 L+₹5.3 L (10.7%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER M
GARRISON ENGINEER M NAVAL AIR STATION ARAKKONAM - 631006
PROVN OF ENGINE BAY AND ENVIRONMENTAL CONTROL SYSTEM OF SQAC AND CAMCO AT AED AND PROVN OF EXTERNAL LIGHTING AT MI ROOM AND PROVN OF GATES FOR GLCB AT OPS AREA AND ADDN AND ALTN TO STATIC TANK AT WIRELESS TRANSMITTING STATION AT ARAKKONAM
2020_MES_378931_1
8935 OF 2020-2021
Open Tender
Civil Works
Item Rate
120 days
GE M NAS ARAKKONAM
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE M NAS ARAKKONAM
₹99,800
Yes
16 Oct 2020
19 Sept 2020
12 Oct 2020
19 Sept 2020
10 Oct 2020
3 Oct 2020
60 days
Amount
Excavating in post holes (or similar holes) each not exc 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50m and making good surface in hard /dense soil complete all as specified and as directed by Engr-in-charge.
Material and labour for cement concrete 1:2:4 type B-2 (Using 20mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed by Engr-in-charge.
Material and labour for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing newly plasterd surface of wall applying two coats of oil emulsion distemper on primed surface over 2 to 3mm thick wall care putty on wall complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation newly plastered surfaces of walls of any description by applying two coats of cement base paint primed /chalk whitening complete all as specified and as directed by Engr-in-charge.
Material and labour for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to TMT bars complete all as specified and as directed by Engr-in-charge.
All as per item No.08 here-in-before but 6 to 8mm dia.
All as per item No.08 here-in-before but 5mm dia and over upto including 10mm dia in stirrups, spaces and binders.
Formwork to fair finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc., also splays between floors and beams, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for reinforced cement concrete (nominal mix)1:2:4 type B-1 (Using 20mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar items etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified and as directed by Engr-in-charge.
Supply and fix anodised aluminium size of 605x605mm snap grid frame work for false ceiling including hangers 6mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed by Engr-in-charge.
Supply and fix for gypsum board 12mm thick in ceiling fixed with independently complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing new false ceiling surfaces and applying two coats of plastic emulsion paint over one coat of pimer complete all as specified and as directed by Engr-in-charge.
Supply and fix for powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (mimimum thickness of powder coating 50 microns) including joining cleats for fixing etc., complete all as specified and as directed by Engr-in-charge. Notes: (i) All the aluminium sections provided under this item shall be measured and converted into weight for payment with the designated unit weight mentioned in the manufacturers catalogue for the corresponding aluminium sections /fittings. (ii) The rate quoted deemed to include necessary grouting/ embedding of the aluminium frames/ supports into floors /walls and making good the disturbed surfaces to match with the existing surfaces and provision of necessary rubber gaskets.
Supply and fix for powder coated anodised sliding or side hung type aluminium door, window and ventilator shutters (minimum thickness of powder coating 50 microns), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as all locking arrangements peg stays 150mm long (1 No), but hinges type B-21, 100mm long (2 Nos) suitable handle (1 No) etc., complete all as specified and as directed by Engr-in-charge. Note: Glass and other materials will be paid and measured separately.
Material and labour for 12mm thick prelaminated particle board interiorr grade, one side with decorative choice and other side balancing (both side white laminated) complete all as specified and as directed by Engr-in-charge.
Supply and fix for 4mm thick sheet glass, ordinary quality on one side fixed in doors /windows, not exc 0.5 sqm in each pane fixed with stainless steel screws, beads /glazing with oil putty etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for 5.5mm thick sheet glass, ordinary quality on one side fixed in doors /windows, exc 0.5 sqm in each pane fixed with stainless steel screws, beads /glazing with oil putty etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for solar control film 25 microns reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed by Engr-in-charge.
Supply and fix for door closer hydraulically regulated, aluminium (extruded section) body, designation No.2, universal type, suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 kg etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for 100mm size mortice lock with two lever (vertical type) brass body and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fix for joist channel, angle, or tee sections fixed indipendently, without connecting plates, etc., cut ordinary length i.e., within 20mm of length indicated conforming to Fe-410-W (Gde-E-250) Quality A complete all as specified and as directed by Engr-in-charge.
Supply and fix for steel work in tubular (square /rectangular) trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade St-240 (medium grade) complete all as specified and as directed by Engr-in-charge.
Material and labour for two coats of synthetic enamel paint on steel and iron surface over 10cm width or girth including preparation of new surface over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply and fix for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in framed roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-charge. Note: Colour will be approved by GE.
Supply and fix for second class hard wood plain fillets, square, rectangular or triangular in section, sectional area exc 13 sqcm and not exc 25 sqcm complete all as specified and as directed by Engr-in-charge.
Material and labour for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, over 10cm width or girth including preparation of new wooden surfaces complete all as specified and as directed by Engr-in-charge.
Material and labour for 18 /19mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, 6mm thick teak wood lipping including polish fixed with screws /nails to timber frame work complete all as specified and as directed by Engr-in-charge.
Supply and fix for continuous piano hinges of brass, bright finish of electro galvanised width of flaps when open in 40mm complete all as specified and as directed by Engr-in-charge.
Supply and fix for extruded brass handles, fabricated type, polished bright size of handle 100mm complete all as specified and as directed by Engr-in-charge.
Material and labour for 20mm thick granite (of any type) tiles machine cut in skirting /dado etc., laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and grinding, polishing, including 1:4 of cement mortar 15mm thick screed bedding complete all as specified and as directed by Engr-in-charge. Make: Tamilnadu Granite/ Telengana/ Johnson/ Somani/ Kajaria/ Spartek/ Orient/ Cera
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engr-in-charge.
Material and labour for PVC tiles /sheets the thickness is 2mm homogeneous laminated plain coloured, marbled mosaic or mottled finish laid with approved rubber based adhesively as per manufacturing instruction in the existing floor surfacecomplete all as specified and as directed by Engr-in-charge. Note: Rates quoted deemed to included for cutting and waste and work in all positions as well as narrow widths.
Material and labour for reinforced cement concrete (design mix) in cement concrete M-30 (Using 20mm gradded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engr-in-charge.
Material and labour for reinforced cement concrete (design mix) in cement concrete M-30 (Using 20mm gradded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and as directed by Engr-in-charge.
Formwork fair finished flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engr-in-charge.
Formwork to side of pillars, posts, struts, piers, columns and stanchions fair finished surfaces of concrete square, rectangular or polygonal complete all as specified and as directed by Engr-in-charge.
Material and labour for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to TMT bars complete all as specified and as directed by Engr-in-charge.
Supply and fix for framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work the rates including for reveting and /or welding and embaded in concrete portion conforming to Fe-290 (Gde-E-165) complete all as specified and as directed by Engr-in-charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, cable laying, etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exc 10sqm on plan and not exc 1.5m in depth and getting soft/ loose soil complete all as specified and as directed by Engr-in-charge.
Returning filling in soft /loose soil, including spreading, leveling, watering and well ramming in layers not exc 25 cms complete all as specified and as directed by Engr-in-charge.
Removing excavated material/ soil exc 250m but not exc 500m and depositing where directed complete all as specified and as directed by Engr-in-charge.
Supply and lay standard size well burnt bricks, sub class 'B', laid in flat, dry in trenches for cable protection complete all as specified and as directed by Engr-in-charge.
Spreading riddled earth as obtained from item No.43 here-in-before for UG cable cushioning complete all as specified and as directed by Engr-in-charge. Note: if the required quantity of riddled earth not obtained from above item the contractor should bring the same from other location shown (not beyond 50m) including necessary earthwork as directed for borrow pit /trench to obtain the required quantity without any additional cost and the cost deemed to be included in the rate quoted by the contractor.
Demolition of unreinforced cement concrete is ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
Material and labour for cement concrete type D-2 1:4:8 (Using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed by Engr-in-charge.
Demolition of reinforced cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick or stone walls etc., including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for reinforced cement concrete (design mix) in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses with M-30 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for reinforced cement concrete (Design mix) in beams, cantilevers, bressummers, lintels over 1.5m span with M-30 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Formwork to faces of curved walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc., vertical or to batter complete all as specified and as directed by Engr-in-charge.
Formwork to sides and soffits of floor or roof curved beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc., also splays between floors and beams, etc., complete all as specified and as directed by Engr-in-charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick fair finished surfaces complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with FOSROC conplast WL water proofing compound at 200ml per 50 kgs of cement complete all as specified and as directed by Engr-in-charge. Note: Fosroc chemical will be measured and paid separately.
Supply only fosroc conplast WL water proofing compound.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for rolled mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc., of grade Fe-410-W (Gde-E-250) quality-A complete all as specified and as directed by Engr-in-charge.
Supply and fix for expanded metal of not exc 4 kg /sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed to wood or steel members complete all as specified and as directed by Engr-in-charge.
Supply and fix for polyetyhlene nylon coloured anti-fly netting with suitable tieing arrangements with metal cover over the tank at the interval of 2.50m in repairscomplete all as specified and as directed by Engr-in-charge. Note: Type and model of anti-fly netting shall be approved by Engineer-in-charge.
Material and labour for 50mm cement concrete type C-1, 1:3:6 (Using 20mm graded stone aggregate) as in plinth protection finishing surface even and fair without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed by Engr-in-charge.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed multi stranded copper conductor drawn into including PVC conduit of size not less than 20mm dia and provision of 1.5 sqmm single core PVC insulated unsheathed multi stranded copper conductor as earth wire and cast iron/ pressed steel terminal boxes for mounting switches, sockets, fan regulator, etc., with 3mm thick plastic laminated sheet cover for the following complete all as specified and as directed by Engr-in-charge. Make for PVC conduit: SUDHAKAR/ AVON PLAST/FINOLEX Make for Copper cable: Finolex /Polycab/ Plaza
One light point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board with other switches, with cables 1.5 sqmm size.
One 3 pin socket outlet 5 Amps, independent board with cables 1.5 sqmm size.
All as per item No.65 here-in-before but one 3 pin socket outlet 5/ 15 Amps, independent board with cables 4 sqmm size. Make for copper cable: Polycab/ Finolex /Plaza
Supply and fix for switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed by Engr-in-charge. Make: Anchor /Cona /Leader
Supply and fix for socket outlet 2 in 1, 3 pin, 5 Amps flush type complete all as specified and as directed by Engr-in-charge. Make: Anchor /Cona /Leader
Supply and fix for switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and as directed by Engr-in-charge. Make: Anchor /Cona /Leader
Supply and fix for ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed by Engr-in-charge. Make: Anchor /Cona /Leader
Supply and fix wall mounting fan heavy duty 450mm sweep AC single phase 230/ 240V with inbuilt regulator and oscillation facility including cutting and neccesery arrangements etc., complete all as specified and as directed by Engr-in-charge. Make: Usha/ Orient/ Crompton/ Almonard
Supply and fix for high efficiency modern 2x2 sqft flat panel 36 watts LED light with panel for recesssed dust free installation with high brightness LEDs for glare free homogenous illumination and suitable for ceilling cut out 600x600mm complete all as specified and as directed by Engr-in-charge. Make: Crompton Cat Part No. LCTLRNE-36-FO-CDL /Philips /Wipro /Surya Roshini Ltd/ Luker Technologies Pvt Ltd
Material and labour for sub main wiring for 2x6 sqmm and 1x6 sqmm along with earth wire with the FRLS PVC insulated copper conductor, single core cable including suitable size of PVC conduit as per site requirement complete all as specified and as directed by Engr-in-charge. Make for Copper cable: Finolex/ Polycab/ Plaza
Supply and fix for sheet metal enclosure vertical DBs 4 way double door including MCCB 63A 4 pole 415V 16 KA adjustable type with spreader terminals, insulating phase barrier and hardware complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/Schneider/ ABB
Supply and fix for MCB TP 40 Amps 'C' curve series complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens /Schneider /ABB
Supply and fix for MCB SP 6 to 32 Amps 'C' curve 240 volts complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/Schneider /ABB
Supply, laying and testing cable XLPE insulated, armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 2 core with necessary connecting arrangements complete all as specified and as directed by Engr-in-charge. Make: Finolex/ Plaza /Polycab
Material and labour for tubes light grade galvanised iron pipes of 40mm sizes with all fittings and fixed to wall/ pole/ under road/ culverts/ drain or laid in floors complete all as specified and as directed by Engr-in-charge. Make: Prakash /Jindal /Tata /Zenith
Material and labour for earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground level connected with and including GI earth wire 4mm dia including alternate 5 layers of charcoal, salt crystal and including 15mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work upto 7.5m and connecting to test point, LT switchgear etc., as per site requirement including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10cm c/c on both ways as reinforcement all as shown in elecrical plate No.3 of SSR Part- I including testing on completion complete all as specified and as directed by Engr-in-charge. Note: Quoted rate deemed to include necessary earth work PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc.,
Material and labour for earth wire of 4mm dia galvanised iron or steel wire fixed to all on battern or receses or chases or burried in ground or drawn in pipe or any other indicated situation for loop earthing etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for GI pipe 15mm light grade galvanised, with all fitting laid in trenches complete all as specified and as directed by Engr-in-charge. Make: Prakash/ Jindal /Tata/ Zenith
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size complete all as specified and as directed by Engr-in-charge. Make: POLYCAB/ PLAZA/ INCAB/ KEI/ UNIVERSAL
50 sqmm 3.5 core
16 sqmm 4 core
Supply, fixing and testing LED post top 40 watt high output with single piece construction comprises of die cast housing and clear acrylic and spun aluminium reflector, IP65 protection lighting luminaire complete all as specified and as directed by Engr-in-charge. Make: Crompton Cat Part No. LPTO-40-CDL-M/ Surya Roshini Ltd Cat Part No. SLE PT 40W ETPP/ Philips/ Wipro /Luker Technologies Pvt Ltd
Supply, fixing and testing of LED bollard not less than 10 watt with robust design and efficient light distribution type, IP 65 protection lighting luminaire etc., complete all as specified and as directed by Engr-in-charge. Make: Crompton Cat Part No. LBLTW-10-WW /Surya Roshini Ltd/ Philips/ Wipro/ Luker Technologies Pvt Ltd
Supply, draw and connect, testing weather proof PVC insulated multi stranded copper conductor 1.5 sqmm round /flat, three core 1100 volt grade complete all as specified and as directed by Engr-in-charge. Make: Finolex/ Plaza/ Polycab
Supply, fixing and testing powder coated outdoor street light control box of size not less than 200x150x80mm CRCA 3mm thick IP65 fabricated by CPRI certified panel manufacturer's and including suitable terminal TPN 10 KA SMC connector, MCB 6A, SP 'C' curve - 01 No, hinged door with two hinges, and locking system - 02 Nos (top and bottom), for fixing as per site and including necessary MS clamps including painting, nuts, bolts and washers as per site requirement complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens /Schneider /ABB
Supply, errect and lay pipe galvanised iron tubing medium grade of 50mm dia on PCC/ on wall etc., for fixing of light fitting complete all as specified and as directed by Engr-in-charge. Make: Prakash/ Jindal /Tata/ Zenith
Material and labour for tubes light grade galvanised iron pipes of 80mm sizes with all fittings and fixed under road/ culvert complete all as specified and as directed by Engr-in-charge. Make: Prakash/ Jindal /Tata/ Zenith
Material and labour for cutting of bituminous roads/ floor for laying of pipe/ cables not exc 1.5m wide and not exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:3:6 type B-1 not less than 100mm thick complete all as specified and as directed by Engr-in-charge. Note: PCC shall measured and paid separately under relevant item of schedule.
Material and labour for PCC for coping of light pole, road cutting etc., whereever necessary 1:3:6 type C-1 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level and complete earth plate connected to GI wire 4mm by brazing /nuts, bolts and earth conductor protected with light grade GI pipe 15mm dia bore from earth plate electrode and upto in and including the earth test point including 20mm bore water pipe medium grade GI tubing including GI funnel, wire mesh alternate layers of charcoal, salt crystal including earth work in any strata, refiling with black cotton soil above the back filling items and removal of the excavated surplus soil and depositing at the place where directed, PCC pit in PCC (1:3:6) type C-1 (Using 20mm graded stone aggregate) RCC pit cover 40mm thick in RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) reinforced with 8mm dia TMT bars @ 7.5mm c/c both ways etc., watering the earth pit to acheive earth resistance below 02 Ohm including testing complete all as specified and as directed by Engr-in-charge. Note: GI wire 4mm, GI tubing 15mm light grade upto 7.5m deemed to be included in the rate quoted by the contractor.
Supply, install, testing and commissioning of outdoor type panel board self supporting totally enclosed CPRI certified factory fabricated LT panel box, made out of 3mm thick CRCA sheet steel powder coated with projected slope roof for rain water protection, dust and vermin proof, hinged front opening double door shutters with neoprene rubber gasket, powder coated including danger plate, provn of connection of GI earth wire 4mm dia - 02 Nos, ventilation louvers, bottom detatchable gland plate complete cubicle panel board suitable for 3 phase 4 wire, 415 volts 50 Hz on 50x50x6mm angle iron base frame with leg, with locking arrangement including necessary foundation, cable gland, necessary earth work and the following switch gear and necessary internal wiring and connections from bus bar to switch gear with appropriate size copper conductor wire including neccessary arrangements complete all as specified and as directed by Engr-in-charge. (i) MCCB 100 Amps adjustable type 4 pole, 16KA - 01 No (In Coming) (ii) MCB 40 Amps 3 pole, 10KA - 05 Nos (04 Out Coming + 01 No spare) (iii) Bus bar aluminium 200 Amps - 01 set (iv) Indication lamp (RYB) -01 set (v) Digital timer with programmable time switch with controller and by pass switch - 01 No (vi) TP Power contactor of suitable capacity - 01 No Make: L&T/ Milestone/ Advance/ Unilec/ C&S Electric Ltd/ Schneider
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and including PVC conduit medium grade of suitable dia complete with fittings and fixings accessories complete all as specified and as directed by Engr-in-charge. Make: Finolex/ Polycab/ National Cables/ Plaza/ Gloster/ ICL/ Nicco
All as per item No.93 here-in-before but sub main wiring with 2x4 sqmm FRLS PVC insulated, copper conductor and 1x4 sqmm FRLS PVC insulated, copper conductor as earth wire. Make: Finolex/ Polycab/ National Cables/ Plaza/ Gloster/ ICL/ Nicco
Supply and fix energy saving LED light fitting not less than 25 watts, IP66 powder coated pressure die cast aluminium high power street light with heat resistant toughened glass with lens including bracket of GI pipe medium grade 25mm dia 1.5m in length and bend to shape with suitable size MS work including two coats of synthetic enamel paint over a coat of red oxide primer nuts, bolts and including connecting up with 3 core flexible copper conductor cable of 1.5 sqmm complete all as specified and as directed by Engr-in-charge. Make: Crompton Cat Part No. LSTS-25-CDL-M/ Surya Roshini Ltd Cat Part No. SLE UL 25W IP66 (LXN)/ Philips/ Wipro/ Luker Technologies Pvt Ltd
Supply and fix MCB, DB SPN 08 way double door DB with 200 Amps rated copper bus bar in SS enclosure double door type complete all as specified and as directed by Engr-in-charge. Note: MCB SPN /SP shall be measured and paid under the respective item of the schedule. Make: Legrand/ Siemens /Schneider /ABB
Supply and fix for MCB SPN 230 V, 40 to 63 Amps with breaking capacity 10 KA 'C' curve complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens /Schneider /ABB
Supply and fix for MCB SP 230 V, 6 to 32 Amps with breaking capacity 10 KA 'C' curve complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens /Schneider /ABB
Supply and fix air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR with copper condenser coil, green gas, mounting stand with all accessories 5 star rated inverter AC complete all as specified and as directed by Engr-in-charge. Note: Extra length of copper wire and tubing as per site requirement is deemed to be included in the rate quoted. Make: Voltas /Carrier/ Blue star
Supply and install voltage stabilizer for automatic operation single phase nautral air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilised at 230 V with accuracy +/- 2.5% and capacity 5 KVA complete all as specified and as directed by Engr-in-charge. Make: V-Guard /Syscom /Volina /Saint Pandit /Zenith
Supply and fix for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one SP MCB 20A 'C' curve complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/ Schneider /ABB
N SRINIVASAN
m/s SRI VALLI ENTERPRISES
SUSII CONSTRUCTIONS
VKR ENTERPRISES
diesel power services (a.p)
SREE BALAJI ENTERPRISES
RD ENTERPRISES
SRI VIGNESH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .