Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | Admitted-Finance |
| 2 | Admitted-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI
REPAIR AND MAINTENANCE OF CENTRAL TYPE AC PLANTS IN TECHNICAL AREA AT CVRDE AVADI
2022_MES_549357_2
8508/E8
Open Tender
Civil Works
Item Rate
240 days
CVRDE AVADI
REPAIR AND MAINTENANCE OF CENTRAL TYPE AC PLANTS IN TECHNICAL AREA AT CVRDE AVADI
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
27 Oct 2022
4 Oct 2022
26 Oct 2022
4 Oct 2022
24 Oct 2022
10 Oct 2022
4 Oct 2022 - 10 Oct 2022
Amount
M&L for disconnecting electrical connections, removing the defective scroll compressor three phase 36TR capacity from the mounting bed of central type Air Conditioner plant , dismantle the unit by cutting and Rewinding the compressor coil with feron resistance Super enameled copper wire and replace bearing and worn out parts of compressor with lathe work for proper alignment with fill up of lubrication oil and assemble the unit , fixed in Central AC plant Testing and commission chiller package AC system complete. The job is inclusive of cutting, transporting brazing the suction and discharge lines by, reconnecting at site . Compressor. Make : M/s Blue Star Pvt. ltd. Note : Refrigerant charging will be measured and paid separately under relevant.
All as per item No 1 but capacity of compressor 48 TR.
M&L for charging R-407A / R-410A Refrigerant gas complete all as specified and directed.
M&L for charging R-22 / R-32 Refrigerant gas complete all as specified and directed.
Supply and fix in repair Dial type with adjustable stem thermometer range min 50 degree all as specified and directed.
Supply and fix in replacement of dial pressure gauge 0-150 PSI. Make : Fiebig/Guru/IMP
Supply and fix in replacement of pressure gauge cock brass of size 3/8" & 1/2" complete all as specified and as directed.
Supply and fix in repair Y strainer of size 80mm all as specified and directed
Supply and fix in repair water flow switch all as specified and directed.
M&L for Chiller unit Control panel suitable 72TR capacity compressor of Central AC plant (Brand:M/s Voltas) with inbuilt safety control, contactor, Timers control wiring micro controller unit including taking down unserviceable panel complete testing all as specified and as directed.
M&L for Chiller unit Control panel suitable 26TR capacity compressor of Central AC plant (Brand:M/s Voltas) with inbuilt safety control, contactor, Timers control wiring micro controller unit including taking down unserviceable panel complete testing all as specified and directed.
M&L for Disconnecting and removing the existing mono block pump set from the installed position by putting dummy plate to suction and delivery pipe line, transporting to workshop. Deassemble the motor removing the burnt out windings, cleaning slots with CTC, and rewinding the same with suitable super enameled copper conductor, insulating varnishing, removing, replacing the worn out bushes/ bearing and pump shaft repair by lathe work for proper alignment, replace gland rope, rubber coupling, washers, nuts and bolts for smooth function with one coat of primer and two coat of synthetic enamel paint after scraping the body surface of pump and motor with emery paper, writing letters, assemble the motor and pump set Transporting to site coupling, connecting electrical and pipe connections testing complete for following capacity at central AC Plant complete all as specified and directed. (a) 7.5HP Monoblock pump set.
All as per item No 10 above but 5HP complete all as specified.
M&L for carry out the leak test at central AC plant refrigeration system by charging the dry nitrogen gas & hold up to 24hrs and rectifying the leakage if any by bracing/ welding/ replacing the 'O' ring etc all as specified and directed.
M&L for replacement thermostatic expansion valve brass type temperature range -25 to +25 degree range with connection accessories at central Ac plant complete all as specified and directed.
M&L for preparation of surfaces of pipe line, pump set and foundation channel, LT Panel of AC plant and painting one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified Note:- (i) AC Plant at NC-I, NC-II, NC-III,(03 Jobs), P-11 (01 Job), EMI/EMC (03 Jobs) & Simulator AC Plant (03 Jobs)
Supply and fix in replacement of Pressure relief valve in AC Plant Condenser unit all as specified and directed.
Supply and fix in replacement of Dryer unit in AC Plant Condenser unit all as specified and directed.
Supply and fix in replacement of high Pressure switch in AC Plant Condenser unit all as specified and directed.
Supply and fix in replacement of low Pressure switch in AC Plant Condenser unit all as specified and directed.
Supply and fix in replacement of chiller water cut off switch in AC Plant unit all as specified and directed.
Supply and fix in replacement of chiller sensor in AC Plant unit all as specified and directed.
Supply and fix in replacement power contactor 3 pole AC 3 phase 40 Amps capacity. In AC plant compressor control panel board all as specified and directed.
Supply and fix in replacement power contactor 4 pole AC 3 phase 32 Amps capacity. In AC plant condenser, chiller motor control panel board all as specified and directed.
Supply and fix in replacement over load relay upto 32A capacity. In AC plant condenser, chiller motor control panel board all as specified and directed.
S&F in replacement MCB three Pole C-40A Amps 415Volt 3 phase all as directed
S&F in replacement Thermal oval load relay MK1 type range 11-18A range complete all as specified and directed
S&F in replacement of Direct-On-Line starter in sheet metal enclosure Type MK suitable for motor rating upto 7.5HP, 415V, 50Hz relay range 13-22A complete all as specified and directed.
S&F in replacement of fully automatic star delta starter in sheet metal enclosure Type MK 1F suitable for motor rating upto 15HP, 415V, 50Hz relay range 14-23A complete all as specified and directed
M & L for dismantling of Cooling Tower Capacity 45 TR at NC-I Central AC Plant installed in CVRDE Avadi without damaging any other equipments and shifting to roof of NC-I Central AC Plant competed with all accessories and including inlet. Outlet Heavy duty MS pipes, Valves, Electric cables complete after installation the Cooling Tower will be properly tested and commissioned complete. Note : (a) The required MS Heavy duty pipes of 100mm dia, 80 mm dia. 50mm dia, 40mm dia and Electric cables measured under respective items of this schedule. (b) The minor items required to connect the systems like gasket nuts, bolts, and washers are included the quoted rates.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 25mm dia bore all as specified and directed.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 40mm dia bore all as specified and directed.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 50mm dia bore all as specified and directed.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 80mm dia bore all as specified and directed.
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of size 100mm dia bore all as specified and directed.
Supply and fix Butterfly Valve 50mm dia bore including connecting flanges of size all as specified and directed.
Supply and fix Butterfly Valve 80mm dia bore including connecting flanges of size all as specified and directed.
Supply and fix Butterfly Valve 100mm dia bore including connecting flanges of size all as specified and directed.
Sub main wiring with 3 runs of single core 16 sqmm 1100 Volts grade, FRLS PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including ISI marked PVC conduit not less than 25mm dia with accessories in walls / roofs / floors etc., including provision of one run of FRLS PVC insulated 16 sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note: 3 runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
SAMYDOSS CONSTRUCTIONS
SRI VENKATESWARA ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .