Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹36.7 LAccepted-AOC | L 1 | Accepted-AOC Being lowest bid and EAS accepted by TC | |
| 2 | L 2₹37.5 L+₹3,069 (0.08%)Rejected-Finance | L 2 | Rejected-Finance Other than lowest | |
| 3 | L 3₹41.3 L+₹3.8 L (10.2%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L 3 | Rejected-Finance Other than lowest | |
| 4 | L 4₹41.6 L+₹4.1 L (11.0%)Rejected-Finance | L 4 | Rejected-Finance Other than lowest | |
| 5 | L 5₹42.4 L+₹5.0 L (13.2%)Rejected-Finance 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L 5 | Rejected-Finance Other than lowest |
Tender Value
₹47.0 L
EMD Value
₹93,980
Closing Date
19 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
SPL REPAIR TO BLDG NO 148 OF AFMSD AND OTHER MINOR WORKS UNDER GE EAST LUCKNOW
2024_MES_666970_2
GE/E/LKO/T-44 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹93,980
Yes
24 Oct 2024
5 Sept 2024
26 Sept 2024
5 Sept 2024
19 Sept 2024
12 Sept 2024
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness below and above ground level, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position as in roofs, floors (other than ground floors) and similar works complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M & L for brick work using non modular fly ash brick, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed.
M & L for brick work with non modular fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with water proofing compound (ISI marked) @ 2% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treatment of surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/ tint, complete all as specified and directed.
M & L for applying two coats of wall care putty on walls overall thickness 3mm and finished surface even and smooth, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and directed.
Forming construction joints 30 mm deep x 10mm wide filled with sealing compound grade "A." complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each, complete, all as specified & directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete, all as specified & directed.
Cutting holes in brick work built in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3, depth of cutting exc half brick but n. exc one brick, complete all as specified and directed.
S&F mild steel holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc. and fixed in position complete all as specified and directed.
M&L plain cement concrete cast in situ 1:3:6 type C1 using 20 mm graded stone aggregate as in copings, hold fast, back filling of pressed steel frame and other similar work water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc including form work complete all as spcefied and directed
S&F pressed steel frame for door with one or more rebates size 125x60mm including necessary fixing lugs, lock striking plates, hinges, hold fast etc. complete all as spcefied and directed
S&F for 30mm thick factory made flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete all as spcefied and directed .
S & F for 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 (a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S&F 5.5mm thick sheet tinted glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples complete all as specified and directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified and direced.
S & F in repairs, PVC coated, MS curtain rods 22 - 25 mm dia with and including fixing of two Nos MS brackets and decorative type PVC knobs at both ends of curtain rod all as specified and directed.
Dismantling of Wall & ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M & L of anodized aluminium snap grid size 605x605mm of frame work for false ceiling complete all as specified and directed.
Providing and fixing of E-board 600 x 600 mm and 4 mm thick white prelaminated sett embosed reinforced designer as approved ceiling board/tiles at any height complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl. cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for vitrified ceramic tiles, light shade,10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in CM 1:4, complete all as specified and as directed.
M&L for vitrified ceramic tiles, light shade,10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dedo/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in CM 1:3, complete all as specified and as directed.
Striping out old roof treatment (tarfelt) from roof top and removing from site, complete all as specified and directed.
M&L for PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coving and roof padding over roof surfaces /sunken treatment etc rounded or chamfered on edges, complete all as specified and directed.
M&L for treatment of foyer roof with reinforced elastomeric liquid water proofing membrane of 400-micron thickness in four layer (100 micron each layer) having SRI of 1 30, tested as per ASTM E 1980 (with solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371 , respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat upto 120 00 as per IS: 101 (P-7/Sec-3) 1990 having VOC less than f g/tr as per ASTM D 3960 and should have excellent resistance to transmission of ponded water upto 2.5 bars of presure for 7 days. It should also be resistant to Ammonia Solution, Sodium Nitrate, Sodium Hydrooxide alongwith water and soap solution as per IS : 101 (P-7/Sec-2) 1990. The water proofing membarane will mbe laminated with 25-40- micron thick transparent Nano modified composite crosslinking polumeric coating with a minimum of 40% solid content as per IS : 101 (P-8/Sec-6) 1993 aln also should pass impact test as per IS : 101 (P-5/Sec-3) 1988 alongwith having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS : 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS : 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self-cleaning and easy -to-clean property with excellentw\ weather stability and DPR (Dirt Pick up ratio)). Surface preparation includes pressure wash cleaning to remove all dust, fungus, etc. The work will be done under the supervision of the Engineer-in-Charge by Graco airless will be done under the supervision of the Engineer-in-Charge by Graco airless machine. The coating thickness and the methodology of application shall strictly be carried out by the authorised/ vendor/ manufacturers with all specifications and as approved by the Engineer-in-Charge. The manufacturer shall give a gurantee for the performance and durability for 10 years.
M & L for 100mm size stainless steel fancy type handle, complete all as specified and directed.
S&F butt hinges of size 100 mm medium weight, stainless steel ISI marked complete all as specified and directed.
S&F aluminium handle, 150mm size, cast type, anodized (ISI marked) complete all as specified and directed..
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked)complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed.
Dismantling of steel windows/ventilators withot taking off shutters, complete all as specified and directed.
S&F for powder coated alumium glazed window shutter sliding type using 1.80 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rails 100x44mm. including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings complete and including glazing by using 5mm thick plain sheet glass and stainless steel wire mess of dia 0.36mm and aperture 1.4mm, complete all as specified and as directed. ((Note-glazed shutters glass thickness not less than 5.00 MM and wiremess shutter with SS wiremesh as approved by GE is also included. No extra payment will be made separately)
S & F for powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for powder coated aluminium grill (opening of gril not more than 100x100mm) fixed to windows or ventilators with anodised aluminium U channel 25x12mm size complete all as specified and directed.
S & F for powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S & F for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 No.) complete all as specified and directed.
S & F for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 No.) complete all as specified and directed.
S&F solid PVC wall lining consisting of 5 mm thick plain colour pvc sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and directed.
S&F 5 mm thick PVC sheet filet of width 35 mm for wall penelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, pipe / cable etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.complete all as specified and directed.
S&F for 150mm internal dia, Salt glazed & Stoneware drain pipe grade 'A' laid in trenches and jointed with cement joints complete all as specified and directed.
M&L for concrete bed to drain pipes of 150 mm dia incl packing under and haunching against the sides of pipes with concrete, after they are laid in cement concrete 1:3:6 type C2 and testing including necessary complete all as specified and directed.
M & L for returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M & L for removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
M&L brick work with sub class B old size bricks, straight or curved on plan exceeding 6 mtr mean radius , built in cement mortar 1:6 including dismantling
M & L for rendering 15mm thick on brick work in CM 1:4 finished even and smooth without using extra cement
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation of manholes all as specified and directed
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in Coping benching of manholes etc and including necessary formwork complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in precast manhole cover and cover slab for septic tanks and including necessary forms and moulds etc and set in cement mortar 1:6 and including demolation of old slab complete all as specified and directed.
M&L TMT 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips.complete all as specified and directed.
M&L for Septic tank including inlet and outlet chambers for 250 users, brick construction (with top of slab at ground level) including necessary excavtion and earth work in any type of soil and disposal of surplus soil to a ditance exc 250 mtr and not exc 500 mtr brick work in burnt brick in cement mortar 1:4 RCC 1:2:4 for roof slab including factory made RCC manhole covers CI 100mm dia vent pipe with cast iron cowl complete all as per TD-709 Sheet 1/1 & 2/2 of CELZ complete all as specified and directed.
M&L for Sokage well 3.0 Mtr dia and 4.00 mtr Deep blow inlet pipe level (depth from inlet pipe to ground level 45 Cms) including excavation and earh work in any type of soil PCC in foundation brick work in honey combed and solid brick work in cement mortar, RCC slab with RCC manhole cover factory made complete all as per TD- 576 Sheet No 1/1 & 2/2 of CELZ complete all as specified and directed.
M&L for 100mm thick PCC type D-2 1:4:8 (40mm graded stone aggregate) for sub base.complete all as specified and directed.
S&F Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S&F powder coated alumium glazed window shutter sliding type using 1.30 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rils 100x44mm Make jindal/Hindalco including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings complete and glazing shall be done by using 5mm thick plain sheet glass Make- Modi guard/saint gobin) and stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F Anodised aluminium Grill (anodised tranparent of dyed to required shade according to IS1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the exiting window frame with CP brass/ stainless steel screws @200 mm centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Enginer-in-charge.
S&F powder coated aluminium anodised frame/chowkat of Alu door fixed with rawal plug and screw or wire expansion hold fasteners complete all as specified and directed.
S&F Providing and fixing powder coatedaluminium partly glazesd and partly paneled door shutter side hung type using 1.50mm thick standered door section having size of styles, top rails 83x44mm where as bottom rails will be made up of 100x44mm Make: Jindal/Hindalico including necessary joining cleats glazing clips, rubber packing, anodized aluminium snap beading screws, anodized aluminium fittings such as 100mm long 3 No. aluminium hinges B-21 ,type 01 No. aluminium tower bolt 200mm long and one no mortise lock 100mm size 4 levers (vertical type) and 01 No 300mm size long aluminium sliding bolt and 02 No fancey type fiber glass 150mm dia circular handle shall be provided to each door and glazing of top panel shall be made of 5.50 thick sheet glass make - Modi/ Saint gobin and pannelling shall be provided with 12mm thick exterior grade pre laiminated partical board with both side choice laminations, all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 72 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per serial item No 72 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per Serial Item No 72 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
Supply and fix switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
Supply and fix electronic ceiling fan regulator with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
Supply only LED bulb 9/10 Watts suitable for B22 white in colour all as specified and directed.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply and fix in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
Supply and fix in replacement LED tube light fittings 1200 mm, 22 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix in replacement ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II for BER procedure complete all as specified & directed.
Supply and fixing ceiling fans complete with blades 1200 mm long GI pipe heavy duty down rods,and accessories,230 V,1200 mm sweep.Min air delivery 210 CFM with service value 6.00 BEE.Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge".
S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed.
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 8 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply & fix LED Ceiling /surface mounted down lighter, 2'X2' , 36W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified. complete all as specified and directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 63 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50sqmm 4.0 core including taking down complete all as specified and directed.
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement)
M & L for Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified
M/S RAJ INTERIORS (BID ID -3100122)
M/s Ramesh Chandra (BID ID -3100251)
QUALITY CONSTRUCTIONS CO (BID ID -3100443)
m/s raghubar dayal (BID ID -3100591)
M/S Reliance Construction (BID ID -3099768)
M/S S S A ASSOCIATES (BID ID -3094615)
Rakesh Traders (BID ID -3100045)
Bidder Name
M/S Vindhya Infraventures
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .