| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹25.5 L+₹4.1 L (19.1%)Rejected-Finance 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹26.9 L+₹5.5 L (25.6%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹30.3 L+₹8.9 L (41.8%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹31.9 L+₹10.5 L (49.2%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
15 Jun 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_524560_1
8421/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (East) Jabalpur
D b(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹90,000
Yes
6 Jul 2022
18 May 2022
17 Jun 2022
18 May 2022
15 Jun 2022
2 Jun 2022
18 May 2022 - 24 May 2022
Amount
Taking down carefully copper/aluminium point wiring ( light,fan,power point or bell point etc) complete including fixture and fitting such as switches,ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M & L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit of white/ivory colour including all accessories after chasing in wall/ceilling etc, and for one light /fan point controlled by one switch including 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor and connecting to earth dolly & to be terminated in & inclusive of MS sunken box 1.2mm thick (flush metal box) for mounting of fittings like switch, socket , fan regulator etc complete with 3mm thick laminated switch board cover all as specified and as directed.
All as per item Srl No 3 above but for One bell point controlled by one bell push complete all as specified by the Engineer-in-Charge.
All as per item No 3 above but for One ceiling fan point controlled by one switch complete all as specified by the Engineer-in-Charge.
All as per item No 3 above but for One exhust fan point controlled by one switch complete all as specified by the Engineer-in-Charge.
All as per item No 3 above but for one light point controlled by two way switch complete all as specified by the Engineer-in-Charge.
All as per item No 3 above but for One 3 Pin, 5/6 amps socket outlet point ,on the same board with with 1.5 Sqmm cable size etc complete all as specified and as directed. .
All as per item No 3 above but for One 3 Pin, 5/6 amps socket outlet point , independent board with 1.5 Sqmm cable size etc complete all as specified and as directed. .
All as per item No 3 here in before but 2.5 Sqmm copper conductor for 5 Pin 15 Amp switch socket combintion on independent board and 2.5 Sqmm stranded copper conductor as an earth continuous wire complete all as specified and directed. Note :- Item Ser No 3.00 to 10.00 for Chasing in wall/ceiling is deemed included in unit rate quoted by the contractor.
Taking down old/unservicable switch any type and S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Taking down old/unservicable push bell & S&F bell push flush type 5 Amp complete all as specified and directed
Taking down old/unservicable switch any type and S&F switch piano flush type 15 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
Taking down old/unservicable switch any type and S &F 5 pin socket outlet, 5/6 Amps / 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed
Taking down old/unservicable switch Socket combination any type and S & F switch socket combination 2 in 1, 3 Pin, 5 A flush type , ISI marked, complete all as specified and directed
Taking down old/unservicable switch Socket combination any type and S & F switch socket combination 2 in 1, 3 Pin, 15 A flush type universal, ISI marked, complete all as specified and directed
Taking down old/unservicable ceiling rose any type and S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
Taking down old/unservicable fan regulator any type and S & F electronic dimmers, 450W, 250V flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed.
Taking down old/unservicable lamp holder any type and S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified & directed.
Taking down old/unservicable Bell any type and S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc, complete all as specified & directed.
M & L sub main wiring including with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2.50 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 2.50 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 2.50 Sqmm cable, one run ( with Green colour for Earth) of 2.50 Sqmm cable and one run of PVC conduit will be measured as one unit.
M & L sub main wiring including with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.00 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 4.00 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 4.00 Sqmm cable, one run ( with Green colour for Earth) of 4.00 Sqmm cable and one run of PVC conduit will be measured as one unit.
M & L sub main wiring including with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- (i) Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run ( with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit. (ii) Item Ser No 21.00, 22.00 & 23.00 for Chasing in wall/ceiling is deemed included in unit rate quoted by the contractor.
Taking down old/unservicable bulb any type and S & F for highly efficient LED bulbs, 10 watt used as a ready replacement for existing GL/CFL/direct fit lamp, in B-22 capacity complete all as specified and directed.
Taking down old/unservicable bulb any type and S & F for highly efficient LED bulbs, 15 watt used as a ready replacement for existing GL/CFL/direct fit lamp, in B-22 capacity complete all as specified and directed.
Taking down old/unservicable bulb any type and S & F for highly efficient LED bulbs, 20 watt used as a ready replacement for existing GL/CFL/direct fit lamp, in B-22 capacity complete all as specified and directed.
Taking down old/unservicable light fitting any type and S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED batten, including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make : Havells Cat Part No -LHEXACP7IN1W010 or equei to Bajaj/Philips /CG
Taking down old/unservicable light fitting any type and S & F 1 x 10W LED bulk head luminaries including LED light driver holder including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ compete all as specified and directed. Make : Havells Cat Part No -LHLDDCXCML8Q020 or equei to Bajaj/Philips /CG
Taking down old/unservicable light fitting any type and S & F LED light fitting 1 X 20/22W 220V, AC decorative box type with driver, holder including LED tube light connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make : Havells Cat Part No -LHEXBTP7IN1S022 or equei to Bajaj/Philips /CG
Taking down old/unservicable light fitting any type and S & F LED light fitting 1 X 30W 220V, AC decorative box type with driver, holder including LED tube light connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed. Make : Havells Cat Part No -LHEXACP7IN1W030 or equei to Bajaj/Philips /CG
S & F for LED luminaire 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed type with high efficieny PMMA diffuser soft glare free light complete with drovers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
Taking down old U/S batten any type/size and S & F MAXOLED batten suitable for tube 20 Watt with ultra bright, glass shell, glare free,wide angle, single side connection complete all as specefied and directed. Make : Havells Cat Part No -LHFXCENNTN1W020 or equei to Bajaj/Philips /CG
Taking down old U/S tube rod any type/size and S & F LED tube 20 Watt MAXOLED tube with single side connection complete all as specefied and directed. Make : Havells Cat Part No -LHLDDCXCML8Q020 or equei to Bajaj/Philips /CG
Supply & fix in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 35W led lamp fitting including lamp all as specified and directed. MAKE: HAVELLS/PHILIPS/CROMPTION/BAJAJ
Taking down old/unservicable MCB DB any type and S & F for sheet metal enclosure MCB DB TPN 4 Way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB DB any type and S & F for sheet metal enclosure MCB DB SPN 8 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down old/unservicable MCB AC Box any type and S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20A, 10 KA 240 volt complete all as specified and as directed.
Taking down old/unservicable MCB any type and S & F MCB triple Pole and neutral rated capacity 63 Amps, 415 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unservicable MCB any type and S & F MCB single Pole and neutral rated capacity 40 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Taking down old/unserviceable MCB any type and S & F MCB single Pole rated capacity 5 to 32 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
Labour only taking down & refixing the ceiling fan/exhaust fan with replacement of unsv 3 core PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc complete all as specified and directed.
Dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with greasing the same with approved grade of grease, making all electrical connection and fixing and connectiong on its existing position and testing on completion complete all as specified and directed.
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed. Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
Supply, fixing and connecting up flexible copper wire twin core of 23/.0078.
Supply only gun metal bush of any size (Make - MSP).
Supply only bearing for ceiling fan (Make - TATA/SKF No.6201/6202).
Supply only bearing for ceiling fan (Make - TATA/SKF No.6203/6204).
Supply only fan condensor 2.5 MFD (Make – USHA / UNIVERSAL).
Supply only fan condensor 4 MFD (Make – USHA / UNIVERSAL).
Supply only split pin.
S&F canopy of ceiling fan bottom and upper side of size 1200/1400/1500mm Make :- Usha / Orient / Bajaj/Havells
S&F heating element of 1500 watt triangular type for geyser complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F heating element of 1500 watt circular type for geyser complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F heating element of 2000 watt for geyser trangular type complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F heating element of 2000 watt for Solar System complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F thermostate for geyser complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F neon lamp yellow/red for geyser complete all as specified Make : BAJAJ/TOSHIBA/HAVELLS
S&F air release valve for geyser complete all as specified Make : Bajaj/ Toshiba/ Havells
Taking down old unserviceable MCCB & S & F of MCCB 63 Amps, 4 Pole, 415V, 16 KA complete all as specified and directed.
Taking down old unserviceable MCCB & S & F of MCCB 100 Amps, 4 Pole, 415V, 16 KA complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal. Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M & L for excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out in soft/loose soil complete all as specified ad dirtected.
M & L for excavation in trenches not exc. 1.5 mtr wide and exc. 1.5 mtr but not exceeding 3.00 mtr in depth, for foundation of poles/Stays etc and and getting out in any type of soil complete all as specified ad dirtected.
M & L for returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25 cm all as specified ad dirtected.
M & L for removing excavated materials not exc 50 mtr and depositing where complete all as specified ad dirtected.
M & L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : maesurement shall be done after puning down of sand.
M & L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
Laying only old bricks retrieved from trenches for cable protection laid flat complete all as directed.
M & L for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above grnd 7.5RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters as directed. Note : Size of lettering and colours of paints will be directed by Engr-in-charge.
Diasmantling of ACSR or AAC conductors of any size from LT poles or distrubution span of complete all as specified & directed.
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing, complete all as specified & directed.
M & L for binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of AACSR/AAC/LT over head conductors of any size with and including 14 SWG binding wire and testing, complete all as specified & directed.
Dismantling ACSR conductor & GI Wire of any size from LT poles or distrubution span & removal from site, complete all as specified and directed.
Fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of Galvanised steel wire 3.15 or 4 mm dia LT over head earth wire, complete all as specified & directed.
M&L for stetching and then stengthening of over head Galvanised steel wire 3.15 or 4mm dia on existing LT poles including binding & jointing the conductor and testing complete all as specified and directed.
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
Dismantling/taking out of defective broken unserviceable insulators of any type and including MS spindles GI washers, nuts etc and S&F insulators pin/shockle type porcelain viterous white, brown or green insulator including on galvanised mild steel spindle, two GI washers & one GI nut, 100 mm height and 65 mm dia suitable for working pressure 1100 volts grade, complete all as specified and directed.
S&F PVC Seperator 2 way for LT O/H electric line complete all as specified and directed.
S&F PVC Seperator 4 way for LT O/H electric line complete all as specified and directed.
Taking down old/unserviceable poles any type and supply , fixing and testing of Steel tubular sewaged pole complete with cast iron base plate, finial taper plug, bolts nuts & screws as specified type 410 SP-31 (09.00 mtr long pole) , etc including one coat primer & two coats of aluminium paint etc complete all as specified & directed.
Dismantling of LT Steel Tubular poles and setting aside for re-use within 50 metres complete all as specified and directed. Note : Excavation, RFR, Removal and PCC will be measured and paid separately.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc.15 cm thickness (below or above ground level) complete all as specified and directed.
M &L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.
M &L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
M &L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in filling in surface channels and drains etc complete all as specified and directed.
M & L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 50 mm dia with all fittings.
All as Per Item No 86 but here-in-before of size 80 mm dia complete all as directed.
All as Per Item No 86 but here-in-before of size 100 mm dia complete all as directed.
Taking down existing unserviceable LT UG/service cable of any description and size complete all as specified and as directred.
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size note- rate is inclusive of cable gland & cable lugs.
(a) 2 core x 10 sq mm
(b) 4 core x 10 sq mm
(c) 4 core x 16 sq mm
(d) 4 core x 25 sq mm
(e) 3.5 core x 50 sq mm
(f) 3.5 core x 70 sq mm
(g) 3.5 core x 95 sq mm
(h) 3.5 core x 120 sq mm
(j) 3.5 core x 150 sq mm
(k) 3.5 core x 240 sq mm
Rep/Maint of floor mounted outdoor cubical type LT Feeder Pillar Box of various sizes including disconnecting all in-coming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size incl. and segregating the serviceable and un-serviceable items with removing old burn out wiring and re-fixing the existing position replacement of un-serviceable parts including re-wiring and PCC works around the Feeder Pillar Box complete all as specified and directed.
Taking down old unserviceable MCCB & S & F of MCCB 160 Amps, 4 Pole, 415V, 36 KA complete all as specified and directed.
Taking down old unserviceable MCCB & S & F of MCCB 200 Amps, 4 Pole, 415V, 36 KA complete all as specified and directed.
Taking down old unserviceable MCCB & S & F of MCCB 250 Amps, 4 Pole, 415V, 36 KA complete all as specified and directed.
Taking down old unserviceable Timer any size & S&F in-replacement of Digital time switch including 3 phase power contactor 40 Amps complete all as specified and directed. Make : Legrand Cat No - 412641 & 3 phase contactor 40 A, Code No - 412549, Havells, L&T or eqv.
Dismantling and taking down street light fittings any size and re-fixing again after erecting of Lt pole etc complete all as specified and directed.
S & F junction box for street lights of size 155 x 210 x 92 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermen proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 65 protection single leaf shutter in front having proper locking arrangements and painted with powder coating paint and suitable size of "connectewell" stud terminal (provision for socket bolting) - 05 Nos suitable for 415 voldts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 6 Amps - 01 No, 4 way, clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc complete and mounted on security light pole complete all as specified and directed. Make ; Hensel cat Part No - DK 1616G with terminals
Taking down old UNSV street light fitting of any type & size and S & F for Smart Bright LED street light fitting of capacity 45 watts with IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fittingcomplete all as specified and directed by Engr-in-Charge. Make : Philips cat part No BRP 052 LED 45 CW SLMR FG S1 PSU GR or equeivalent to Havells/Bajaj
Taking down old UNSV flood light fitting of any type & size and S & F for Smart Bright essential flood LED light fitting of capacity 50 watts with IP 65/66 protection and pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fittingcomplete all as specified and directed by Engr-in-Charge. Make : Philips cat part No BVP140 P LED 50 CW WB S1 PSU 50W MG P4287 or equeivalent to Havells/Bajaj
Taking down partly unserviceable/unserviceable security/street/gate/flood light fittings from poles/towers/Perimeter Fencing of any type upto 9 m height by manual or mechanical means and for necessary repair and make srviceable as per complaint given by department (E/M service cell) through job card/complaint register on day to day basis all to the satisfaction of Engr in charge & complete all as specified and directed Note :- Ballast, Lamp holder, capacitor, ignitor, covers and lamps of required wattage/type shall be measured and paid separately.
S&F of Electronic driver suitable for LED fitting 25 watt Make : bajaj/Wipro/Havells/ Crompton
S&F of Electronic driver suitable for LED fitting 45 watt Make : bajaj/Wipro/Havells/ Crompton
S&F of Electronic driver suitable for LED fitting 60 watt Make :Bajaj/Havells/Philips/Crompton
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part- I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground and laid down through 20 mm PVC medium grade conduit complete with fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire etc completer all as specified and directed by Engr-in-Charge.
Schedule of credit amount of Rs. 1,08,988.00 to be deducted during AOC
S K TRADERS
ELCON
Goodluck Enterprises
Skyline Encon
RAVINDRA ELECTRICAL
M/S BHATIA CONSTRUCTIONS
SHIVALIK ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .