| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.6 L+₹1.3 L (12.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.0 L+₹2.7 L (26.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹13.0 L+₹2.8 L (26.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹13.2 L+₹2.9 L (27.9%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | YOGINDER KUMAR GUPTA AND COMPANY L4 | AMBIKA ENTERPRISES L2 | shiv shanker enterprises L7 | NISHTHA BUILDERS L1 | M/S GOYAL CONSTRUCTIONS L3 | BHATIA ENTERPRISES L5 | M/S KAVYA ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. (except light fittings), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. | 860 | PER POINT | 2 ₹1,720 | 2 ₹1,720 | 5 ₹4,300 | 1 ₹860 Lowest | 1 ₹860 Lowest | 2 ₹1,720 | 1 ₹860 Lowest |
| 2.00 | Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and directed. | 1,240 | RM | 1 ₹1,240 Lowest | 2 ₹2,480 | 5 ₹6,200 | 1 ₹1,240 Lowest | 1 ₹1,240 Lowest | 2 ₹2,480 | 1 ₹1,240 Lowest |
| 3.00 | Taking down carefully by unscrewing from boards/outlet boxes, unserviceable fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, regulators, call bells, plug tops, etc. and removal from site complete all as specified and directed.
(NOTE: This item is to be measured only when only existing fitting/fixture is required to be replaced. Not to be combined with taking down of point wiring under Item No 01 here-in-before). | 900 | Each | 1 ₹900 Lowest | 2 ₹1,800 | 5 ₹4,500 | 1 ₹900 Lowest | 1 ₹900 Lowest | 2 ₹1,800 | 1 ₹900 Lowest |
| 4.00 | Taking down carefully by unscrewing from board / outlet boxes / walls, unserviceable internal light fittings & bulk head fittings, etc any type for reuse or removal from site complete all as specified and directed. | 1,237 | Each | 1 ₹1,237 Lowest | 2 ₹2,474 | 5 ₹6,185 | 1 ₹1,237 Lowest | 1 ₹1,237 Lowest | 3 ₹3,711 | 1 ₹1,237 Lowest |
| 5.00 | Taking down carefully unserviceable bldg security lights, gate lights, bollards & flood lights, of any type, after disconnecting electrical connectiosn and removal from site complete all as specified and directed. | 64 | Each | 1 ₹64 Lowest | 5 ₹320 | 10 ₹640 | 1 ₹64 Lowest | 1 ₹64 Lowest | 5 ₹320 | 1 ₹64 Lowest |
| 6.00 | Taking down of unserviceable Distrubution Boards, any type or size including MCCB/RCCB/MCBs and disconnecting the serviceable MCCBs/MCBs and keeping in safe custody for reuse or removal from site complete all as specified and directed.
(NOTE: Measurement shall be considered only for the DBs) | 71 | Each | 1 ₹71 Lowest | 5 ₹355 | 10 ₹710 | 1 ₹71 Lowest | 1 ₹71 Lowest | 5 ₹355 | 1 ₹71 Lowest |
| 7.00 | Taking down unsv MCBs, any type for reuse or removal from site complete all as specified & directed.
(NOTE: This item is to be measured only when only existing MCBs are required to be replaced. Not to be combined with taking down of DB under Item No 06 here-in-before). | 12 | Each | 1 ₹12 Lowest | 5 ₹60 | 10 ₹120 | 1 ₹12 Lowest | 1 ₹12 Lowest | 3 ₹36 | 1 ₹12 Lowest |
| 8.00 | Taking down unsv MCCBs, any type for reuse or removal from site complete all as specified & directed.
(NOTE: This item is to be measured only when only existing MCCBs are required to be replaced. Not to be combined with taking down of DB under Item No 06 here-in-before). | 7 | Each | 5 ₹35 | 5 ₹35 | 11 ₹77 | 1 ₹7 Lowest | 1 ₹7 Lowest | 3 ₹21 | 1 ₹7 Lowest |
| 9.00 | M&L for concealed type point wiring with FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.20 mm thick conforming to IS-5133 (Part-I) with 2.0 mm thick phenolic laminated sheet top cover (ISI Marked) for mounting switches / regulator / bell push / sockets, etc and including FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, complete all as specified and directed for the following :-
(NOTE: Wiring shall be done in existing PVC conduit. Quoted rate shall be excusive of the cost of pvc conduit) | - | - | - | - | - | - | - | - | - |
| 9.01 | for one light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral | 145 | Point | 195 ₹28,275 | 100 ₹14,500 Lowest | 205 ₹29,725 | 100 ₹14,500 Lowest | 200 ₹29,000 | 180 ₹26,100 | 195 ₹28,275 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
7 Aug 2025, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR/MAINT OF INTERNAL ELECTRIFICATION SYSTEM INCL REPLACEMENT OF UNSERVICEABLE LIGHT FITTINGS, DBs, EARTHING, ETC FOR OTM ACCN OF DOMESTIC AREA AND ZHOPRA COMPLEX AT AF STN SIRSA
2025_MES_720803_1
GE/SRA/T-38/2025-26
Open Tender
Miscellaneous Works
Item Rate
300 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹44,000
Yes
27 Aug 2025
16 Jul 2025
8 Aug 2025
16 Jul 2025
7 Aug 2025
26 Jul 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. (except light fittings), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and directed.
Taking down carefully by unscrewing from boards/outlet boxes, unserviceable fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, regulators, call bells, plug tops, etc. and removal from site complete all as specified and directed. (NOTE: This item is to be measured only when only existing fitting/fixture is required to be replaced. Not to be combined with taking down of point wiring under Item No 01 here-in-before).
Taking down carefully by unscrewing from board / outlet boxes / walls, unserviceable internal light fittings & bulk head fittings, etc any type for reuse or removal from site complete all as specified and directed.
Taking down carefully unserviceable bldg security lights, gate lights, bollards & flood lights, of any type, after disconnecting electrical connectiosn and removal from site complete all as specified and directed.
Taking down of unserviceable Distrubution Boards, any type or size including MCCB/RCCB/MCBs and disconnecting the serviceable MCCBs/MCBs and keeping in safe custody for reuse or removal from site complete all as specified and directed. (NOTE: Measurement shall be considered only for the DBs)
Taking down unsv MCBs, any type for reuse or removal from site complete all as specified & directed. (NOTE: This item is to be measured only when only existing MCBs are required to be replaced. Not to be combined with taking down of DB under Item No 06 here-in-before).
Taking down unsv MCCBs, any type for reuse or removal from site complete all as specified & directed. (NOTE: This item is to be measured only when only existing MCCBs are required to be replaced. Not to be combined with taking down of DB under Item No 06 here-in-before).
M&L for concealed type point wiring with FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.20 mm thick conforming to IS-5133 (Part-I) with 2.0 mm thick phenolic laminated sheet top cover (ISI Marked) for mounting switches / regulator / bell push / sockets, etc and including FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, complete all as specified and directed for the following :- (NOTE: Wiring shall be done in existing PVC conduit. Quoted rate shall be excusive of the cost of pvc conduit)
for one light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps socket outlet on independent board, with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps Pin Socket Outlet on the same board, with 1.50 Sq. mm wire for mains & neutral
for one 15-20 Amps socket outlet on independent board, with 2.50 Sq. mm wire for mains & neutral
for one 25-32 Amps AC or geyser outlet, on independent board, with 4.0 Sq. mm wire for mains & neutral
M&L for concealed type point wiring with FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.20 mm thick conforming to IS-5133 (Part-I) for mounting MODULAR TYPE SWITCHES / REGULATOR / BELL PUSH / SOCKETS, ETC and including FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, complete all as specified and directed for the following :- (NOTE: Wiring shall be done in existing PVC conduit. Quoted rate shall be excusive of the cost of pvc conduit. Modular cover plate & frame shall be measured and paid seperately)
for one light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps socket outlet on independent board, with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps Pin Socket Outlet on the same board, with 1.50 Sq. mm wire for mains & neutral
for one 15-20 Amps socket outlet on independent board, with 2.50 Sq. mm wire for mains & neutral
for one 25-32 Amps AC or geyser outlet, on independent board, with 4.0 Sq. mm wire for mains & neutral
M&L concealed Point Wiring with 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable for main & neutral and 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk GI Terminal Box (1.2mm thick) of suitable size( as required) duly painted with Red Oxide Metal Primer with 2.0mm thick Phenolic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, Sockets, etc with Earth Continuity Wire connected to Common Earth dolly complete all as specified and as directed for the folowing:- (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of terminal box & laminate cover. (iii) Cost of cutting chases for concealed wiring and making good surfaces with cement plaster and putty shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
for one light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps socket outlet on independent board, with 1.50 Sq. mm wire for mains & neutral
for one 5/6 Amps Pin Socket Outlet on the same board, with 1.50 Sq. mm wire for mains & neutral
for one 15-20 Amps socket outlet on independent board, with 2.50 Sq. mm wire for mains & neutral
for one 25-32 Amps AC or geyser outlet, on independent board, with 4.0 Sq. mm wire for mains & neutral
M&L concealed Point Wiring with 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable for main & neutral and 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk GI Terminal Box (1.2mm thick) of suitable size (as required) for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, Sockets, etc with Earth Continuity Wire connected to Common Earth dolly complete all as specified and as directed for the folowing:- (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of terminal box. Modular cover plate & frame shall be measured and paid seperately (iii) Cost of cutting chases for concealed wiring and making good surfaces with cement plaster and putty shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
for one MODULAR TYPE light / bell / ceiling fan / exhaust fan point controlled by one way switch with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 5/6 Amps socket outlet on independent board, with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 5/6 Amps Pin Socket Outlet on the same board, with 1.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 15-20 Amps socket outlet on independent board, with 2.50 Sq. mm wire for mains & neutral
for one MODULAR TYPE 25-32 Amps AC or geyser outlet, on independent board, with 4.0 Sq. mm wire for mains & neutral
S&F Sub-main Wiring with 2-Runs of 1.50 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.50 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire along with the Wiring drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
All as per item No 13 above, but sub main wiring with 2 runs of 2.50 sqmm wires for mains and one run of 2.50 sqmm wire for earth continuity drawn in PVC CONDUIT complete all as specified & as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
All as per item No 13 above, but sub main wiring with 2 runs of 4.0 sqmm wires for mains and one run of 4.0 sqmm wire for earth continuity drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
All as per item No 13 above, but sub main wiring with 2 runs of 6.0 sqmm wires for mains and one run of 6.0 sqmm wire for earth continuity drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
All as per item No 13 above, but sub main wiring with 2 runs of 10.0 sqmm wires for mains and one run of 10.0 sqmm wire for earth continuity drawn in PVC CONDUIT complete all as specified & as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
S&F in repairs PVC electrical conduit, 25 mm dia, MMS type, medium grade incl all fittings and accessories complete all as specified and directed.
S&F in repairs PVC Casing caping pipe, 25 mm size, MMS type, medium grade incl all fittings and accessories complete all as specified and directed.
S&F new Switch piano, flush type, 6 Amps, single pole, one way complete all as specified and directed.
S&F new Modular Switch 1 way 6 Amps, 1 module complete all as specified and directed.
S&F new Switch piano, flush type, 16 Amps, single pole, one way complete all as specified and directed.
S&F new Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S&F new socket outlet, flush type, 6 Amps, 2-in-1, multi-purpose 5 pin type complete all as specified and directed.
S&F new Modular Socket, 6 Amps, 3 pin type, 2 module complete all as specified and directed.
S&F new socket outlet, flush type, 16 Amps, 2-in-1, multi-purpose 5 pin type complete all as specified and directed.
S&F new Modular Socket, 6/16 Amps, 2 module, 2/3 pin combined type complete all as specified and directed.
S&F new switch socket combination outlet, flush type, 6 Amps, 2-in-1, 5 pin type complete all as specified and directed.
S&F new switch socket combination outlet, flush type, 6/16 Amps, 2-in-1, 5 pin type complete all as specified and directed.
S&F new Bell push, flush type, 6 Amps complete all as specified and directed.
S&F new Modular Bell push 6A, 2 module complete all as specified and directed.
S&F new Fan regulator, 5 step, 120 watt, 230 volts, single pole complete all as specified and directed.
S&F new Modular Fan regulator, 5 step, 120 watt, 2 module, 230 volts, single pole complete all as specified and directed.
S&F new Modular Fan regulator, 5 step, 120 watt, 1 module, 230 volts, single pole complete all as specified and directed.
S&F new Call bell, ding dong type, AC 230/240 volts, single pole complete all as specified and directed.
S&F new Ceiling rose, 3 terminals, 230 volts, surface type, bakelite/polycarbonate, isolated body complete all as specified and directed.
S&F new lamp holder with back plate suitable for batten fittings or to be mounted on walls complete all as specified and directed.
S&F in repair Phenolic laimated Sheet, 2mm thick for mounting switches, sockets, fan regulator etc of size 200 x 150 x 50 mm including cutting for mounting of switches, sockets, etc complete all as specified and as directed. (NOTE: This item shall not be measured for new point wiring)
All as per Item No 43 above, but with 2 mm thick Phenolic laminated sheet cover of size 250 x 200 x 50 mm complete. (NOTE: This item shall not be measured for new point wiring)
All as per item No 43 above, but with 2 mm thick Phenolic laminated sheet cover of size 350 x 300 x 50 mm complete. (NOTE: This item shall not be measured for new point wiring)
S&F new Modular type White cover plate with frame 1/2 module complete all as specified and directed.
-ditto- but for Modular type White cover plate with frame 3 module complete all as specified and directed.
-ditto- but for Modular type White cover plate with frame 4 module complete all as specified and directed.
-ditto- but for Modular type White cover plate with frame 6 module complete all as specified and directed.
-ditto- but for Modular type White cover plate with frame 8 module complete all as specified and directed.
S&F Modular LED Skirting Light, 230 V, 3 module with cover plate & frame along with GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box alongwith lamp. Concealed conduit wiring shall be measured seperately.
Supply, assembling & fixing in repairs Modular MCB protected Power Unit comprising of following accessories :- (i) Powder Coated Steel terminal box, 06 module - 01 No (ii) Modular Cover Plate with Frame, 06 Module - 01 No (iii) 16 Amps 3 Pin Modular Socket, 02 module - 01 No (iv) 16 Amps Plug Top - 01 No (v) 25 Amps Motor Starter, 02 Module - 01 No (vi) 25 Amps, Single pole Mini MCB, 10kA - 01 No
Supplying, assembling and fixing modular AC power unit comprising of 01 No 16 Amps socket and 01 No 32 Amps SP MCB, 3 modules along with GI metallic flush box, cover plate and frame duly concealed in wall incl dismantling of existing power unit complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. Concealed conduit wiring shall be measured seperately.
S&F in repairs 32 Amps modular motor starter with cover plate & frame, 2 modules along with GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box alongwith starter. Concealed conduit wiring shall be measured seperately.
Supply only LED Bulb, B-22 base, 09/10 watt complete all as specified and directed.
Re-fixing of serviceable light fitting, any type, after minor repairs or replacement of drivers including necessary electric connection & testing complete all as specified and directed.
S&F LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed.
S&F wall light/fixture light made up of high grade engineering plastic material suitable for & incl 9 W LED lamp B22 base with all accessories complte all as required and directed. (MAKE: HAVELLS (FLORET) Cat No : LHFHCHE1TL1W020 or similar model in other makes specified in tender)
S&F wall light/fixture, stainless Steel brushed nickle finish fixture with opal Glass diffuser suitable for & incl 9 watt LED lamp B22 Base with all accessories complte all as required and directed. (MAKE- HAVELLS (Florentine WL 1LS B22 SS) Cat Part No-LHFOAJE1TZ1I060 or similar model in other makes specified in tender)
S&F Decorative LED step light , recessed type, 03 Watt, Warm White, in powder coated aluminium die cast housing complete as specified and directed by Engr-in-Charge. (MAKE: HAVELLS , Cat No : LHEOAAP5I46H003 / HALONIX, Cat No: HLOSTL-27-03WW or similar model in other makes specified in tender)
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 100 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
-ditto- as per Item No. 56 but of 1 X 18/20 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
-ditto- as per Item No. 56 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
-ditto- as per Item No. 56 but of 1 X 05 Watt capacity in polycarbonate housing with lumen output not less than 100 lumen per watt
S&F recess mounted slim-fit downlighter, round or square, having glare free frosted diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 15 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
-ditto- as per Item No. 60 but recess mounted LED downlighter of capacity 12 Watt
-ditto- as per Item No. 60 but surface mounted LED downlighter of capacity 15 Watt
-ditto- as per Item No. 60 but surface mounted LED downlighter of capacity 12 Watt
Supply only LED Bulb, B-22 base, 09/10 watt complete all as specified and directed.
S&F recess mounted LED luminaire, of size 600 mm x 600 mm, 100 lumen/watt, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED (Cool Day Light) and incl all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
All as per Item No. 65 above, but 36 Watt recess mounted LED luminaire (Warm White) of size 600 mm x 600 mm complete
All as per Item No. 65 above, but 18 Watt recess mounted LED luminaire, of size 300 mm x 300 mm complete
S&F Surface mounted LED luminaire, of size 600 mm x 600 mm, 100 lumen/watt, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED (Cool Day Light) and incl all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed.
All as per Item No. 68 above, but 18 Watt surface mounted LED luminaire of size 300 mm x 300 mm complete
S&F Switch, Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt , complete all as specified and as directed.
S&F Flame Proof Weather Proof LED Tube Light Fitting 1x20 Watt (4 Feet) with product in Aluminium Die-cast Alloy LM6 complete with Construction of Gas Gr. IIA, IIB, Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Elecrically Connecting up including tube rod complete all as specified and as directed. NOTE: Cost of tube rod shall deemed to be included in the quoted rate
S&F LED post top luminiare, 25 watt, with die cast aluminium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver complete all as specified an directed. (Make : BAJAJ, Cat No: BGCTN 25W LED WW / HALONIX, Cat No: HLPT-04-25CW / HAVELLS, Model: RUBY / ORIENT, Cat No: OSL-MARFICPT025W or equivalent model in other makes specified in tender) ) NOTE: Wire for connection of luminaire, if replaced, shall be measured and paid seperately.
S&F LED Building Security Light fitting (Warm White), of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 100 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 3000 degree K (h) life not less than 50000 hours of operation (NOTES: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Wire for electric connection shall be measured and paid separately)
35/36 Watt Luminaire
45 Watt Luminaire
50 Watt Luminaire
70/72 Watt Luminaire
S&F LED pathway luminare, 9/10 watt, in powder coated ERW MS tubular/square sections, with cylindrical diffuser on top complete, IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC base (1:2:4 Type B1) complete all as specified and directed. NOTE: Wire for connection of luminaire shall be measured and paid seperately. Cost of PCC base is deemed to be included in the quoted rates.
S&F in repair Bracket/Arm suitable for street light fittings, made out of 25 mm bore (light grade) GI pipe length not exceeding 1.20 metre long, fixed with 02 sets of flat iron clamp of size 40mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium/synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core, 2.50 sqmm, 1100 Volt, conforming to IS 694 all as specified and directed
S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door, 415 volts with provision for MCCB as incomer and MCB as outgoing and connecting up complete all as specified and directed.
S&F SPN DB, IP 43 protection, double door, 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F SPN DB, IP 43 protection, double door, 240 volts, 8 way, with 100 Amps copper Bus Bar complete all as specified and directed.
S&F Sheet Metal Enclosure, Single Door, 2 way with provision to mount MCBs complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with provision to mount MCB, 32 Amps, 240 volts and connecting up complete all as specified and as directed.
NOTE FOR ITEM NO. 77 to 81 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately. (2) Quoted rate is deemed to be inclusive of blanking plate for blank slots after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCCB, 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S&F MCCB, 4 pole, 63 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S&F MCCB, 4 pole, 160 Amps, 25 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S&F MCCB, 4 pole, 200 Amps, 36 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed.
S&F MCB, 'B' Curve, TPN, 415 volts, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'B' Curve, SPN, 40-63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'B' Curve, single pole, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'B' Curve, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Re-fixing of serviceable MCCBs, any type or capacity and in any position complete all as specified and directed.
Re-fixing of serviceable MCBs, any type or capacity and in any position complete all as specified and directed.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and as directed. NOTE: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
GENERAL NOTES :- Light Fittings, Meter panel, DB, MCCB, MCB, Modular fittings shall be procured from authorised dealers. Purchase Vouchers, e-way bills and manufacturer's test certifiactes shall be submited by contractor before claiming payment for the items.
AMBIKA ENTERPRISES (BID ID -3374684)
M/S GOYAL CONSTRUCTIONS (BID ID -3378820)
YOGINDER KUMAR GUPTA AND COMPANY (BID ID -3373266)
BHATIA ENTERPRISES (BID ID -3378481)
M/S KAVYA ENTERPRISES (BID ID -3373111)
shiv shanker enterprises (BID ID -3378502)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .