| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC FIRST FLOOR CREATIVE TOWER EROOR POST VYTTILA ERNAKULAM PIN 682 306 | ERNAKULAM | ERNAKULAM | KERALA | 682306 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.8 L+₹1.0 L (6.52%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
4 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aditya Vanka
GE Navy Lakshadweep Coast Guard Road Kavaratti Island UT Of Lakshadweep 682 555
8295 REPAIRS AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SUCH AS HT 11 KV VCBs TRANSFORMERS XLPE UG CABLES ALONGWITH ALLIED EXTERNAL EM WORKS AT MINICOY ISLAND UNDER GE NAVY LAKSHADWEEP
2021_MES_474348_2
8295/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minicoy
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Navy Lakshadweep
₹41,000
Yes
9 Jun 2022
14 Oct 2021
6 Nov 2021
14 Oct 2021
4 Nov 2021
21 Oct 2021
60 days
Amount
Repairs and servicing of HT 11 KV VCB of current rating upto 630Amps capacity type by drawing out breaker assembly from panel and carrying out the following work :- (i) Cleaning/ decarburizing of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc... (ii) Adjust the trolley in and out mechanism , (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done (iv) Checking all end terminals, tighting the nuts, bolts and washers, replace the unserviceable nuts, bolts & washers, draw-in the breaker, put in position, engage the VCB with the supply system and test for smooth functioning complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of unserviceable spare parts such as Charging motor, EFR, Aux relays, Vertical connection adapter, Fixed/Moving contacts, Battery backup etc.. will be measured and paid under respective items (ii) Primary/Secondary injection Test Kit and Insulation testing equipment shall be arranged by the contractor and rate quoted is deemed to included for the same.
Supply and fix Earth relay suitable HT 11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fix Auxilary relays suitable for VCB of existing make at site including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of vacuum interrupters 11KV with all fittings suitable for existing makes including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of current transformer 5/5A and 15 VA burden suitable for existing makes including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Potential Transformer 11KV/110V and 50VA burden suitable for existing makes including testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix Charging motor operates on single Phase 230 V AC,50 Hz power supply for auto charging of HT breaker suitable for M/s Siemens India Ltd HT 11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Disconnection and Removing old unserviceable Power pack unit Providing, installation & commissioning of Power Pack Input 230 V AC, Output 12 V DC suitable for HT VCB Panel complete all as specified and directed by Engineer-in-Charge.
Supply and Replacement of unserviceable Battery 12 Volts 150 AH including taking down unservisable battery complete all as specified and directed by Engineer-in-Charge.
Topping up / complete renewal of Transformer oil having breakdown strength not less than 65 KV/Min for oil cooled Transformers complete all as specified and directed by Engineer-in-Charge.
Disconnection and removing unserviceable Transformer Tap changer and supply and fix new Transformer Tap changer made of Brass material for regulating LT volage suitable for existing Transformer of capacity 250 KVA complete all as specified and directed by Engineer-in-Charge.
Disconnection and taking down the Transformer 160 KVA capacity from the existing position and transporting to work shop and opening the outer cover,draining out the oil and lifting the core along with winding ,finding the faulty /burnout primary and secondary winding and rewinding with fine enameled insulated copper winding of same size/guage , turns keeping in hot air oven till the moisture evoporates ,reassembling the transformer parts such as core ,winding ,outer cover , refilling back the Transformer oil comlete and transporting back to its original position and reconnecting the LT/HT cable connections complete all as specified and directed by Engineer in charge.
Description all as per Sl item No. 12 above but of capacity 250 KVA all as specified and directed by Engineer-in-Charge.
Disconnection and taking down unserviceable power contactor and Supply and fix Power Contactor with coil voltage 240 V, current 160A, 440V, 3 Pole, AC 50 Hz and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB of capacity 63 A ,4 P 415 V , 50 Hz ,10KA Conforms to IS/IEC 60947-2 & IEC 60947-2 with ddjustable thermal setting: 0.8-1.0 x In, along with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 15 above but of capacity 100 A, 25KA, complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 15 above but of capacity 250 A, 36KA, complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 15 above but of capacity 400A, 50KA, complete all as specified and directed by Engineer-in-Charge.
Supply and fixin replacement of three phase power factor capacitor of capacity 25 KVAr , 440 V , 50 Hz and testing complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 19 but of capacity 15 KVAr all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 19 but of capacity 10 KVAr all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 19 but of capacity 5 KVAr all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Powerfactor controller control circuit Board (PCB) for auto switching (on/off) of power factor panel along with internal pre-wiring complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Digital type Voltmeter for measurement of three phase voltages having accuracy Class-1 with necessary PT connections in LT Panel board complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Digital type Ammeter for measurement of three phase currents with necessary CT connections in LT Panel board complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Digital type multi function meter for monitoring / recording Single/three phase voltages ,currents, power ,powerfactor,KWh and frequency with necessary CT/PT connections in LT Panel board complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of ON LOAD CHANGEOVER SWITCH three phase 440V ,4 P of current rating 160 A with breaking capacity 36KA along with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of ON LOAD CHANGEOVER SWITCH three phase 440V ,4 P of current rating 250 A with breaking capacity 36KA along with necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 kV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Aluminium conductor cable of size 16 to 50 sq mm incl taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 kV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Aluminium conductor cable of size 70 to 90 sq mm incl taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Indoor type jointing kit heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed by Engineer-in-Charge, of size 185 Sqmm
Material & Labour for Outdoor type Straight through jointing kit,heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor complete along with jointing material all as specified and as directed by Engineer-in-Charge, of of size 185 Sqmm
Material & Labour for replacement of XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 185 Sqmm Complete all as specified and directed by Engineer-in-Charge.
S&L in replacement strandard aluminium conductor with 1100 volts grade heavy duty UG cable XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed LT UG cable 16 sqmm 4.0 core Complete all as specified and directed by Engineer-in-Charge.
Description all as per Sl item No. 34 above but 25 sqmm 3.5 Core/4.0 Core all as specified and directed by Engineer-in-Charge
Description all as per Sl item No. 34 above but 50 sqmm 3.5 Core/4.0 Core all as specified and directed by Engineer-in-Charge
Description all as per Sl item No. 34 above but 70 Sqmm 3.5 Core/4.0 Core all as specified and directed by Engineer-in-Charge
Description all as per Sl item No. 34 above but 95 Sqmm 3.5 Core/4.0 Core all as specified and directed by Engineer-in-Charge
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and as directed by Engineer In Charge.
Supply and laying unreinforced pre-cast concrete cable cover, class HV, type 1, flat size 300 x 180 x 40 mm for cable protection complete all as specified and as directed by Engineer In Charge.
Material and labours for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying, gently punned and stretching the cable complete all as specified and directed by Engineer in Charge. Note: (i) Punned thickness shall only be measured and paid. (ii) In case of non-availability of river sand, Ridled earth (Confirming with IS-1255) shall be used for sand cushioning after obtaining written approval from GE
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil for removal of old pipes/ laying of new pipes/erection of poles complete all as specified & directed by Enginner In Charge.
Returning filling in, with excavated soils including spreading, levelling, watering and well ramming in layers not exc. 25 Cms complete all as specified and directed and upto the satisfaction of Engineer in charge.
Removing excavated material/ surplus soil exceeding 250 Mtr and n.exc. 500Mtr and depositing where directed at a level n.exc. 1.50 Mtr above the starting point,all as specified and directed and upto the satisfaction of Engineer in charge.
Cutting the existing PCC harstanding/WMB sub-base/road of width 0.25 Mtr x 0.25 Mtr depth for laying the cables through GI Pipes, including excavation in any type of soil, RFR , removal and filling with PCC (1:2:4), Type B-1 upto 20 cms on the top portion matching with the existing PCC road surfaces and remaining depth with the retrived earth for making the the road cut portion good, well compacted, complete all as specified and as directed by Engineer in Charge. Note: GI pipes shall be measured and paid seperately
Material and labour for providing PCC (1:3:6), type C2, using 40mm graded stone aggregate, as in foundation filling and mass concrete, including necessary use and waste of form work, complete all as specified and as directed by Engineer in Charge.
Supply and lay GI pipe, light grade of dia 80mm, for cable protection, complete including taking down old unserviceable pipe complete all as specified and as directed by Engineer in Charge.
Description all as per Sl item No. 47 above but of 50mm dia bore all as specified and as directed by Engineer in Charge. Notes for all Sl item Nos. 1 to 48 : (a) Daily Collection of complaints from the Department/ Engr-in-Charge is the responsiblity of Contractor. After collecting Complaints from Complaint Register/Site order Book or as per Insturction of JE/AGE by Phone/SMS, complaint should be completed within 48 Hours of receiving the complaint. Complaints with financial implication upto Rs.15,000.00 shall be completed with in 03 Days and those with more than Rs. 15,000.00 shall be completed with in 10 Days (Including Holidays). If complaint not attended in stipulated time period, double the recovery of the respective item will be recovered from the dues to the contractor. (b) Minimum 01 Technician with 01 Nos helper (with all tools, and testing materials, ladder as per the site requirement) shall be always employed (with police verification of both Technician and helper) and attendance Register will be maintained by contractor to complete the complaints. Recovery @ of Rs 500.00 per day for Technician and @ of Rs 350.00 per day for helper will be recovered, If Technician/helper are not employed in Minicoy Island. (c) These items will be operated only if found necessary at site during the maintenance period. The contractor has no claim over the operation of full items / spares under these items and payment will be made accordingly only for spares replaced at site and as per quoted rates.
BHATNAGAR ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .