Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹1,870Admitted-Finance KINFRA HITECH BIO TECHNOLOGY PARK PLOT NO 21 KALAMASSERY ERNAKULAM KERALA 683503 | ERNAKULAM | KERALA | 683503 | ₹1,870 | Admitted-Finance |
| 2 | ₹1,950Admitted-Finance | ₹1,950 | Admitted-Finance |
| 3 | ₹95,354Admitted-Finance | ₹95,354 | Admitted-Finance |
| 4 | ₹2.5 LAdmitted-Finance 3RD FLOOR BESTECH BUSINESS TOWER BESTECH TOWER SOHNA ROAD IIIRD FLOOR SECTOR 48 GURUGRAM CT00000131 GURGAON HARYANA 122018 | GURUGRAM | HARYANA | 122018 | ₹2.5 L | Admitted-Finance |
| 5 | ₹37.0 LAdmitted-Finance | ₹37.0 L | Admitted-Finance |
| Sl No | Description | Qty | Unit | BOSTON SCIENTIFIC INDIA PRIVATE LIMITED | Ace Cardiopathy Solutions Pvt Ltd S | K D MEDICARE | STRYKER INDIA PRIVATE LTD | Radhagovind Medical & Pro.Store | CD DISTRIBUTORS | CAREON HEALTHCARE SOLUTIONS PVT LTD | MOHAN EXPOT |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00RATE CONTRACT OF NEUROLOGY ITEMS :- | |||||||||||
| 1.01 | Super-selective High flow infusion catheters for Cerebral/Spinal AVMs (compatible with n-butyl cynoacrylates)- Flow guided | 1 | Nos | - | 21,000 ₹21,000 Lowest | 36,000 ₹36,000 | - | 54,000 ₹54,000 | - | - | - |
| 1.02 | Super-selective High flow infusion catheters for Cerebral/Spinal AVMs (compatible with n-butyl cynoacrylates)- Flow guided | 1 | Nos | - | - | 36,000 ₹36,000 Lowest | - | 42,000 ₹42,000 | - | - | - |
| 1.03 | Super-selective High flow infusion catheters for Cerebral/Spinal AVMs (compatible with n-butyl cynoacrylates)- Flow guided | 1 | Nos | - | - | 36,000 ₹36,000 Lowest | - | 42,000 ₹42,000 | - | - | - |
| 1.04 | One tip marker microcatheter, 167 cm | 1 | Nos | - | - | 36,000 ₹36,000 Lowest | - | - | - | - | - |
| 1.05 | Super-selective high flow infusion catheters for Cerebral/Spinal AVMs (compatible with DMSO) with detachable tips | 1 | Nos | - | - | 59,000 ₹59,000 Lowest | - | 84,500 ₹84,500 | - | - | - |
| 1.06 | Super-selective high flow infusion catheters for Cerebral/Spinal AVMs (compatible with DMSO) with detachable tips | 1 | Nos | - | - | 59,000 ₹59,000 Lowest | - | - | - | - | - |
| 1.07 | Super-selective high flow infusion catheters for Cerebral/Spinal AVMs (compatible with DMSO) with detachable tips | 1 | Nos | - | - | 59,000 ₹59,000 Lowest | - | - | - | - | - |
| 1.08 | Super-selective high flow infusion catheters for Cerebral/Spinal AVMs (compatible with DMSO) with detachable tips | 1 | Nos | - | - | 59,000 ₹59,000 Lowest | - | - | - | - | - |
| 1.09 | Super-selective high flow infusion catheters for Cerebral/Spinal AVMs (compatible with DMSO) without detachable tips | 1 | Nos | - | - | 36,000 ₹36,000 Lowest | - | - | - | - | - |
Tender Value
₹2.5 Cr
EMD Value
₹5 L
Closing Date
13 Jan 2025, 5:00 pmClosed
MEMBER SECRETARY
AS PER TENDER
RATE CONTRACT OF NEUROLOGY ITEMS
2024_RNTMC_439937_1
61/23-12-2024
Open Tender
Miscellaneous Goods
Item Wise
730 days
AS PER TENDER
Please refer Tender documents.
2 documents required · 2 mandatory
₹400
Yes
AS PER TENDER
₹5 L
Yes
AS PER TENDER
5 Jul 2025
24 Dec 2024
14 Jan 2025
24 Dec 2024
13 Jan 2025
6 Jan 2025
31 Dec 2024
RATE CONTRACT OF NEUROLOGY ITEMS :-
One tip marker microcatheter, 167 cm
Delivery Microcatheter
Two tipped micro-catheter Compatible with DMSO/Glue
Atraumatic Microguide wires with torque device for use with micro catheter: Sizes: 0.007”
Atraumatic Microguide wires with torque device for use with micro catheter: Sizes: 0.008”
Atraumatic Microguide wires (straight tip) with torque device for use with micro catheter: Sizes: 0.010”
Atraumatic Microguide wires (straight tip) with torque device for use with micro catheter: Sizes: 0.012”
Atraumatic Microguide wires with torque device for use with microcatheter: 0.014”
Atraumatic Microguide wires with torque device for use with microcatheter: 0.018”
Atraumatic Microguide wires with torque device for use with microcatheter: Extra support
SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS: EXCHANGE LENGTHS
SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS: EXCHANGE LENGTHS
SPECIAL ATRAUMATIC MICROGUIDE WIRES WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS: EXCHANGE LENGTHS
SPECIAL MICROGUIDE WIRE DOCKING DEVICE-0.010”/0.014”
Electrolytic Detachable coils for intracranial aneurysm treatment: latest generation Platinum coils (Regular sizes)
Electrolytic Detachable coils for intracranial aneurysm treatment: latest generation Platinum coils ( Nano sizes)
Electrolytic Detachable coils for intracranial aneurysm treatment: latest generation Platinum coils ( Large)
Instant Electrothermally detachable Coated/Bioactive platinum coils Complex Super Soft Coil Primary wind .012"-.014" )
Instant Electrothermally detachable Coated/Bioactive platinum coils (Complex Soft Coil Primary wind .014")
Instant Electrothermally detachable Coated/Bioactive platinum coils (Helical Super Soft Soft coil Primary wind .012"-.014")
Instant Mechanical detachable coils for intracranial aneurysm treatment (Coated platinum coils)
Instant Mechanical detachable coils for intracranial aneurysm treatment (Coated with bioactive material)
18 Instant Thermally Detachable coils with detachment system Shape: Complex / Helical 1000
Instant Thermally Detachable coils with detachment system
Instant Thermally Detachable coils with detachment system
FLOW COILS: The Free Spirales for injection with soft platinum structure with O.D. of 0.007
Push able coils to be used with coil pushers
Interlock detachable platinum fibered coil
INTERMEDIATE CATHETERS/Distal Access catheters for triaxial set-ups - Accessing distal vasculature/ For specific device delivery of flow diverter/ and long length stent retrievers Sizes (diameter) (00.038", 0.040", 0.044", 060”)
INTERMEDIATE CATHETERS/Distal Access catheters for triaxial set-ups - Accessing distal vasculature/ For specific device delivery of flow diverter/ and long length stent retrievers Sizes (diameter) (0.064”,0.066”, 0.068”)
INTERMEDIATE CATHETERS/Distal Access catheters for triaxial set-ups - Accessing distal vasculature/ For specific device delivery of flow diverter/ and long length stent retrievers Sizes (diameter) 0.070”, 0.071”
INTERMEDIATE CATHETERS/Distal Access catheters for triaxial set-ups - Accessing distal vasculature/ For specific device delivery of flow diverter/ and long length stent retrievers Sizes (diameter) 0.074
Guiding catheters: For Neurovascular procedures - 0.070”, 0.071”
Guiding catheters: For Neurovascular procedures - 0.074”
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Guiding catheters: For Neurovascular procedures - 0.088”
Long carotid sheath for Neurovascular procedures Diameter: 0.086, 0.100 (6F)
Long carotid sheath for Neurovascular procedures Diameter: 0.086, 0.100 (7F)
Long carotid sheath for Neurovascular procedures Diameter: 0.086, 0.100 (8F)
Accessories for detaching coils (Should be same make as of approved coils) Mechanical detachment system.
Electrolytic detachment systems.
Electrothermally detachable system
Thermally detachable system
35 Coil pushers
Poly vinyl alcohol (PVA) particles for pre-operative Tumor embolization and treatment of epistaxis
Detachable balloon microcatheters for detachable balloons
Detachable balloons
Electrolytically Detachable Intracranial Stents for stent assisted coiling of aneurysms - Open cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Detachable Intracranial Stents - for stent assisted coiling of aneurysms: At least partially retrievable - Closed cell design
Electrolytically Detachable Intracranial Stents for stent assisted coiling of aneurysms: Completely retrievable
Intracranial Stents for stent assisted coiling of aneurysms - Hybrid cell design
Braided Intracranial stent (Braided Intracranial stent: 16 DFT Wires closed cells)
Braided Intracranial stent (Braided Intracranial stent: 48 DFT Wires braided)
Endoluminal embolization device 64 wires
Endoluminal embolization device 48 wire Nitinol braided
Endoluminal embolization device 48 hybrid nitinol wires
Endoluminal embolization device 64 wires with cobalt chromium shell and platinum core
Endoluminal embolization device-Surface modification with poly phosphorylcholine: Diameter 3.5-6mm (Compatible with 0.027" micro catheters)
Endoluminal embolization device-Surface modification with poly phosphorylcholine: Diameter 3.5-6mm (Compatible with 0.021"microcatheters)
Endoluminal embolization device, Baby sizes
En Surface modification with poly phosphorylcholine doluminal embolization device: 2.5mm
Endoluminal embolization device Integrated double layered device
Intrasaccular Device For treatment of aneurysms
Intrasaccular device For treatment of aneurysms-Shape spherical to cubical
Intrasaccular device enabling Simultaneous coiling
Electro thermal detachment for Intrasaccular devices PIGTAILCATHETER – FDA/CE APPROVED
DIAGNOSTIC CEREBRAL ANGIOGRAPHY CATHETER- (Simple curve) FDA/CE APPROVED
DIAGNOSTIC CEREBRAL ANGIOGRAPHY CATHETER- (Complex curve FDA/CE APPROVED
DIAGNOSTICCATHETER FOR SPINALANGIOGRAPHY - FDA/CE APPROVED
Balloon guiding catheter 8F
Balloon guiding catheter 9F
Proximal Protection devices during Carotid angioplasty and stenting:
Distal Protection device for Carotid angioplasty and stenting:
PUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULTS
MICROPUNCTURE NEEDLE FOR VASCUALAR ACCESS IN CHILDREN
SHORT INTRODUCER SHEATH FOR ADULTS (Size 4Fr-10Fr.) (Standard Length)
SHORT INTRODUCER SHEATH FOR PAEDIATRIC
LONG INTRODUCER SHEATH (> 50 cm- <90CM) (Size 5Fr. - 7Fr.)
LONG INTRODUCER SHEATH; 80cm long Proximal to Distal 8fr OD
LONG INTRODUCER SHEATH; 90cm/91 cm long Proximal to Distal 8fr OD
LONG INTRODUCER SHEATH for Femoral & Radial ID of 0.088
Lumen Delivery Catheter; 105cm long, 8cm Distal Flexible zone
Lumen Delivery Catheter; 105/ 115 cm long, 12cm Distal Flexible zone
Delivery assist catheter
HYDROPHILIC DIAGNOSTIC GUIDE WIRE - (REGULAR LENGTH, REGULAR STIFFNESS)
HYDROPHILIC DIAGNOSTIC GUIDE WIRE – (EXCHANGE LENGTH, REGULAR STIFFNESS)
HYDROPHILIC DIAGNOSTIC GUIDE WIRE - (REGULAR LENGTH, EXTRASTIFF)
HYDROPHILIC DIAGNOSTIC GUIDE WIRE - (EXCHANGE LENGTH, EXTRASTIFF)
PTFE COATED DIAGNOSTIC GUIDE WIRE - (REGULAR LENGTH, EXTRASTIFF SHAFT STRENGTH) - AMPLATZ TYPE
ANGIOPLASTY INFLATION DEVICE- ANALOG DISPLAY
Extracranial Stents for use in carotid Self expandible, Open cell design
Extracranial Stents for use in carotid- Self expandible, Closed cell design
Extracranial Stents for use in carotid: Self expandible, Hybrid cell design
Extracranial Stents for use in carotid: Self expandible, Dual layered
Balloon mounted Extracranial bare metal Stents for use in carotid & vertebral arteries & osteal lesions: Rapid exchange (monorail)
Balloon mounted Extracranial bare metal Stents for use in carotid & vertebral arteries & osteal lesions Over-the-wire system
Intracranial Stents for treatment of Atherosclerotic stenotic lesions: Self expandible
Intracranial Stents for treatment of Atherosclerotic stenotic lesions of Intracranial vessels: Balloon premounted
Stent-graft (covered stent) for pseudoaneurysm or fistula treatment: Monorail system
Stent-graft (covered stent) for pseudoaneurysm or fistula treatment: Over-the-wire system
Balloon angioplasty catheters for intracranial use
Balloon angioplasty catheters for extracranial use
Double lumen balloon for angioplasty and stent delivery
Occlusion balloons for flow modification/assistance for treatmentof wide-neck intracranial aneurysm: Single lumen; Compatible with 0.010” micro guidewire
Occlusion balloons for flow modification/assistance for treatment of wide-neck intracranial aneurysm: Single lumen: Compatible with 0.014” micro guidewire
The single lumen remodeling balloon catheters
Double lumen SuperCompliant occlusion balloons for flow modification/assistance for treatment of wide-neck intracranial aneurysm: Compatible with DMSO Double lumen (for wire & balloon), Supercompliant, Radio-opaque markers at tips Variable sizes (3mm, 4mm, 5mm, 6mm) and lengths-7mm, 15mm, 20mm or more Central lumen compatible with intracranial stent/coil deployment, liquid embolic agent Good radio-opacity for visualization and accurate positioning
Balloon for venous remodeling technique 8X80
Balloon for venous remodeling technique 10X80
Accessories: Should contain the following items (Guide wire Torquer for 0.025”- 0.035”, 0.038” guidewires)
Accessories: Should contain the following items (One-way, three ways stop cock)
100-150 cm long extension tubing for measurement of pressures (pressure monitoring line)
Large bore contrast tubing (with flow regulating knob & high pressure resistant)
Disposable luer lock syringes; 10 - 12 ml
Luer lock disposable/glass syringes; 1cc/2cc
Luer lock three-piece disposable/glass syringes having markings up to 50ml for contrast injection
Lyophilized poppy seeds oil/Ethiodized oil
Infusion tubing sets for arterial pressure infusion
TUOHY BORST WITH SIDE ARM-HAEMOSTATIC Y CONNECTOR
TUOHY BORSTDOUBLE WITH SIDE ARM (HAEMOSTATIC DOUBLE Y CONNECTOR) FOR CO-AXIAL/TRIAXIAL SYSTEMS
ARTERIAL PUNCURE CLOSURE DEVICES
Large bore aspiration catheter for thrombectomy – 0.068" ID FDA/EU APPROVED
Large bore aspiration catheter for thrombectomy – 0.071 ID FDA/EU APPROVED
Large bore aspiration catheter for thrombectomy – 0.074 ID FDA/EU APPROVED
Reperfusion catheters –FDA/EU APPROVED
Connecting Tube Used with Thrombosuction
Collection Canister & Intermediate Tubing
Thrombosuction Pump (Suction machine)
Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke - Compatible with 0.021" micro catheters
Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke- Compatible with 0.017" microcatheters
Mechanical thrombectomy devices for Flow Restoration in Acute Ischemic Stroke Revascularization Device- Dual Layer
Stroke Kit Package
EVOH (ethylene vinyl alcohol)
n-butyl cyanoacrylate (NBCA)
N-Hexyl cyanoacrylate monomer glue
Tantalum micronized particles
Endo-vascular snares for retrieval of intravascular foreign objects
SAFE SET PPRESSURE FLUSH LINE
1LITER PLASTIC POUCH OF SALINE BEGS (NOT BOTTELS)
500ML PLASTIC POUCH OF SALINE BEGS
DISPOSABLE DRAPS FOR PATIENTS AND MACHINE
LEUR LOCK 1CC SYRING
LEUR LOCK 2CC SYRING
LEUR LOCK 10CC SYRING
LEUR LOCK 50CC SYRING
10CM EXTENSION FOR 3WAY LINE
MICRO BALLON CATHETER FOR EMBOLISATION BALLON LENGHT 9MM DIAMETER 2.2 DISTAL /PROXIMAL INNER DIAMETEWR 0.010in / 0.015in DISTAL/ PROXIMAL OUTER DIAMETER 1.6F/2.8F CATHETER LENGTH 165CM
Y - CONNECTOR ROTATORY HOMEOSTATIC VALAVE
Ace Cardiopathy Solutions Pvt Ltd S
CAREON HEALTHCARE SOLUTIONS PVT LTD
MOHAN EXPOT
K D MEDICARE
item8-A
item8-B
CD DISTRIBUTORS
STRYKER INDIA PRIVATE LTD
Radhagovind Medical & Pro.Store
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
TENDER-61-converted.pdf
Tender Documents • 2.90 MB
BOQ_790162.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .