| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.6 L+₹2.3 L (8.26%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹31.8 L+₹3.6 L (12.7%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹32.0 L+₹3.7 L (13.2%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹32.5 L+₹4.3 L (15.2%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/ MAINT TO VARIOUS FANS, GEYSERS AND REWINDING INCLUDING INTERNAL WIRING AND ALLIED WORKS AT II LINE UNDER GE ALIPORE KOLKATA
2022_MES_572151_2
GE/ALP (8137B) OF KOLKATA 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and category b (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹60,000
Yes
24 Mar 2023
9 Feb 2023
24 Feb 2023
9 Feb 2023
23 Feb 2023
16 Feb 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed.
Material and labour in repair for point wiring for Modular fitting, for one light/fan/call bell point with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade, concealed type, controlled by one way switch including 1.5 sqmm PVC FRLSH insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through non metallic rigid PVC heavy duty concealed conduit of size 25mm dia with wall thickness not less than 1.6 mm including conduit accessories like bends, tees junction boxes, etc including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, complete after and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 2 here-in-before but for one light point controlled by two way switch complete as specified and directed.
All as per item No 2 here-in-before but for 3 pin 6 Amps socket outlet modular type on the same board with 1.5 sqmm cable complete as specified and directed.
All as per item No 2 here-in-before but for 3 pin 6 Amps socket modular type on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 2 here-in-before but for socket modular type 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 1.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
Supply & Fixing in repair modular switch single pole, one way, 6 Amp, 1 module, complete all as specified and directed.
Supply & Fixing in repair modular switch single pole, one way, 16 Amp, 1 module, complete all as specified and directed.
Supply & Fixing in repair modular Socket, 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply & Fixing in repair modular Socket, 6/16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply & Fixing in repair modular switch single pole, two way, 6 Amp, 1 module, complete all as specified and directed.
Supply & Fixing in repair modular Bell push 6 Amp, single pole, 1 module, complete all as specified and as directed.
Supply & Fixing in repair Bell multi music type, complete all as specified and as directed.
Supply & Fixing in repair Modular step type fan regulator, 120W, 2 module, complete all as specified.
Supply & Fixing in repair Modular White cover plate with frame, 2 module complete all as specified and as directed.
Supply & Fixing in repair Modular White cover plate with frame, 4 module complete all as specified and as directed.
Supply & Fixing in repair Modular White cover plate with frame, 6 module complete all as specified and as directed.
Supply & Fixing in repair Modular White cover plate with frame, 8 module complete all as specified and as directed.
Supply & Fixing in repair Modular White cover plate with frame, 12 module complete all as specified and as directed.
Supply & Fixing in repair Modular Metal flush box 2 module complete all as specified and as directed.
Supply & Fixing in repair Modular Metal flush box 4 module complete all as specified and as directed.
Supply & Fixing in repair Modular Metal flush box 6 module complete all as specified and as directed.
Supply & Fixing in repair Modular Metal flush box 8 module complete all as specified and as directed.
Supply & Fixing in repair Modular Metal flush box 12 module complete all as specified and as directed.
Material and labour in repair for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through suitable size of non metallic rigid PVC heavy duty of size 25 mm dia having wall thickness not less than 1.5mm with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover or for fixing of switch/sockets/regulators etc as per site requirement after and making good the distrubed surfaces as per the existing complete all as specified and as directed.
All as per item No 25 here-in-before but for one light point controlled by two way switch with 1.5 sqmm cable complete as specified and directed.
All as per item No 25 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm cable complete as specified and directed.
All as per item No 25 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 25 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
S & F in repair socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type.
M & L in repair for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, all as specified.
Supply and fix in repair switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed.
Supply and fixing repair switch piono, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed.
Supply and fixing repair switch piono, flush type 5 Amps 230 Volt single pole, two way complete all as specified and as directed.
Supply and fixing in repair ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed.
S&F in repair bell push, flush button single pole 6 amps 230 volts AC with polycarbonate body all as specified and directed.
S&F in repair bell electric heavy duty Ding Dong type 230 volts single pole all as specified and directed.
S&F in repair fan regulator electronic, flush type humming with (step type) polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed.
Supply and fixing in repair sub-main wiring concealed/surface type as directed from main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Conduit carefully and taking down old existing sub main wiring with accessories complete all as directed. Note : Two runs of 6 sqmm, one run of 6 sqmm cable and one run PVC conduit shall constitute one unit.
Supply and fixing in repair sub-main wiring conceaed surface type as directed from main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 4 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 4 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Conduit carefully and taking down old existing sub main wiring with accessories complete all as directed. Note : Two runs of 4 sqmm, one run of 4 sqmm cable and one run PVC Conduit shall constitute one unit.
Supply and fixing in repair sub-main wiring concealed/surface type as directed from main DB's to sub DB's with PVC (FRLS) insulated & unsheathed two runs of 2.5 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 2.5 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Conduit carefully and taking down old existing sub main wiring complete all as directed. Note : Two runs of 2.5 sqmm, one run of 2.5 sqmm cable and one run PVC conduit shall constitute one unit.
Taking down Carefully Submain wiring of size 2.5 Sqmm to 10 Sqmm including making good disturbed surface of wall/ ceiling etc complete all as specified and as directed
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLSH) 2.5 Sqmm 3 core , 1100 Volts grade conforming to IS 694.
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLSH) 0.75 Sqmm 2 core , 1100 Volts grade conforming to IS 694.
Supply and Fixing in replacement MCB, single pole, 240 Volts of capacity (6-32 Amps) 'C' series breaking capacity 10 KA.
Supply and fixing in repair MCB SPN, 16 to 32 Amps, 240 Volts, breaking capacity 10KA complete all as directed.
Supply and fixing in repair MCB TPN 63 Amps, 415 Volts, breaking capacity 10KA complete all as directed.
Supply and fixing in repair MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing in repair MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing in repair MCCB 4Pole 160Amps, 415 Volts ,Adjustable type breaking capacity 35KA including nut bolts lugs & cable of suitable size complete all as directed.
M&L for taking out unserviceable DBs of any type / capacity incl MCBs for fixing of new or old all as directed
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI wire of size 4.0 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm thickness all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32mm x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Dismantling and taking out old earth plate with connected material from site complete all as specified and directed.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mm x 4mm galvanised iron strip.and all as per directed.
Dismantling and taking down old earth continuity conductot from site complete all as specified and directed.
Supply & fixing in repair for Test point box of suitable size including terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connected with earthing strip including taking out old unsv and make good the disturbed surface complete all as per directed.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity. Note : New spare parts required for replacement shall be measured and paid seperately.
Supply only heating elements of 2 KW 230 V inbuilt with thermostat, indicator lamp ,apparatus plate other accessories suitable for existing water heater of any type including connection with suitable cable all as directed
Supply only heating elements of 1.5 KW 230 V inbuilt with thermostat, indicator lamp ,apparatus plate other accessories suitable for existing water heater of any type including connection with suitable cable all as directed
Supply only electronic digital type tempreture indicator as suitable for existing water heater all as specified and directed.
Supply only PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser.
Supply only 450mm long brass CP connection with 2 nuts without nipple suitable for geysers.
Material and labour preparation to old painted surface of storage water heater and painting of geyser 25 ltr capacity with two coats of synthetic enamel paint (white) by using spray gun all as directed.
Supply and fix as in repair for Split cover made out of 22 guage sheet duly painted with synthetic enamel paint suitable for water heater of 25 ltr capacity.
Supply and fixing as in replacement patented nano polymer coated steel inner tank of 25Ltr capacity geyser suitable for model of (Make: Cromption/Usha/Bajaj) complete all testing and make good in disturbed surface at existing location and all as specified and as directed)
Supply and fix as in repair for non return valve, 15mm bore, screwed down high pressure, cast copper alloy, chromium plated.
Supply and fix as in repair for pressure release valve 15mm bore 'T' type at inlet/ outlet or dead weight type heavy duty.
Supply and fix as in repair for glass wool , between the inner and outer vessel of water heater any type and capacity.
Supply and fix in repair 15 Amp plug top complete all as specified and directed.
Supply and fix in repair rubber gasket for appratus plate any type/capacity all as specified and directed.
Supply and fix in repairs Bib taps 15mm bore cast iron alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
Material and labour for power supply unit consisting of starter with 20 Amps over load protection, MCB-20 Amps, 2 Pin & Earth plug socket including MS/PVC box & top cover for AC. (Make : Legrand/Crabtree/Havells)
Taking down ceiling fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same as directed Note : Supply & fixing new spare parts required for replacement shall be measured and paid seperately
Rewinding of ceiling fan in repair, 1200mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotton binding, heat varnished and including flexbile cable for electric connection all as directed.
Supply & fixing in repair of ball bearing of size 6201/6202. (Make :- Tata/SKF)
Supply & fixing in repair of metal bush bearing suitble for ceiling fan 1200/1400 mm sweep of any type and size complete all as specefied and directed.
Supply and fixing in repair of ceiling fan shaft suitable for 1200/1400 mm sweep of any type and size complete all as specified and directed
S&F in repair capacitor for ceiling fan 2.5 MFD complete all as specified and directed.
Supply & fixing in repair fan blade (3 Nos blade is one set) 1200 mm sweep suitable for USHA/Havells/Bajaj or equivelent make fan and all as specified and directed. (Make :- Usha/Bajaj/Havells)
Supply and fix as in repair of MS clamps made out of 50mm x 6mm flat iron suitable for hanging of ceiling fan on pipe including necessary cutting, threading, drilling, fixing arrangement split pin, nuts, bolts washer etc as directed.
M&L in replacement of GI tubing 15mm bore 'light grade', galvanised, with all fitting; suitable for hanging of ceiling fan as required all as per directed.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.all as directed
Taking down exhaust fan/wall mounted of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position. Note : New spare parts required for replacement shall be measured and paid seperately.
Rewinding of exhaust fan (250/300/350/400)mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and all as directed.
Supply & fixing in repair Exhaust fan blade of capacity 200mm sweep suitable for Model no: USHA/Havels/Bajaj or equivelent make complete all as specified and directed.
Supply & fixing in repair Exhaust fan blade of capacity 300mm sweep suitable for Model no: USHA/Havels/Bajaj or equivelent make complete all as specified and directed.
Supply & fixing in repair Exhaust fan blade of capacity 350mm sweep suitable for Model no: USHA/HavelsBajaj or equivelent make complete all as specified and directed.
M&L for Painting of Exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, two coats after cleaning all dust etc.all as directed.
Supply and fixing AC single phase 10 to 60 Amp prepaid energy meter of LCD type display having credit status indication, calibration LED push button for scroll, numeric keypad for token entry, CIU (Customer Interface Unit) connector and STTD with RS 232 communication including taking down existing meter and depositing in MES Store yard. complete all as specified and as directed. (Make- L&T / AE/HPL/C&S)
Supply and fixing in repairs Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories including suitable dia GI pipe for fixing of light with all fixing arrangement including PCC, electrical connections complete all as specified and as directed. (Make : Bajaj Cat No 24973 BJAOL 2 BC or equivalent make of Havells/Crompton/ Magik)
Supply and fixing in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed. (Make :- Anchor/Philips/Legrand)
Supply and fixing in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. (Make :- Anchor/Philips/Legrand)
Supply and fixing in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed. (Make :- Anchor/Philips/Legrand)
Tirupati Buildcon Pvt. Ltd.
RADHA ENTERPRISE
M/S J S ENTERPRISES
ARATI TRADING CO
ROY CONSTRUCTION
SEN ELECTRIC WORKS
PUTUL CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .