Tender Value
₹44.5 L
EMD Value
₹89,100
Closing Date
17 Jun 2024, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
SPECIAL REPAIR OF EXISTING FIRE ALARM AND FIRE DETECTION SYSTEM OF A B AND C BLOCK OF DESIDOC AND PROVISION OF WATER COOLERS WITH SUITABLE STABILIZER AT JCB LAB UNDER GE I RnD DELHI
2024_MES_654608_1
GE/RND-21/DLI/2024-25
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-c (vi)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
₹89,100
9 Sept 2024
17 May 2024
20 Jun 2024
17 May 2024
17 Jun 2024
3 Jun 2024
Amount
Two loop control panel having CPU with 640 character display including backlite LCD display qwerty programming and operating manuals supporting 1 to 10 signaling line circuits (upto 5 extendable card and supporting 103 network modes complete as required (2 Main panel)
320 Character LCD display repeater panel with touch LCD display
S&F Central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required complete all as specified and directed.
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS:11360 including taking down old unserviceable detector complete all as specified and directed.
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type heat detector with base with rate of rise cum fixed temperature as per IS: 2175 including taking down old unserviceable detector complete all as specified and directed.
Supply, laying of 2x1.5 Sqmm fire survival armoured cable with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable propylene Rubber (EPR) insulation and steel wire armouring multi stranded FRLSH cable ISI marked complete all as specified and directed.
Supply, laying in repair of multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 4 core 1.5 sqmm ISI marked complete all as specified and directed.
Supply and fix addressable manual call point break glass type with alarm LED complete all as specified and directed.
Supply and fix in replacement Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db Measured at 1.5 m with sound output variation of (±) 5 db 1000 mtr range complete all as specified and directed.
Supply, Installation,Testing and Commissioning in replacement of addressable control module required for various outputs to other systems like signal to switch off AHU, access control etc. complete all as specified and directed.The control module should be EN-54/LPCB/UL/VDS complete all as specified and directed.
Supply and fixing in replacement of Response Indicator on surface/recessed MS box having two LED, metalic cover complete all as specified and directed.
Supply and fixing in replacement Photoluminiscent Gas Release caution sign board complete with fixing arrangements, the sign board shall be square in shape with red background to indicate manual call device, fire extinguisher and the directional array for exit/stairs etc complete all as specified and directed.
Supply, Installation, Testing and commissioning in replacement of digital audio amplifier 75 watt 25V rms operating at 240 volts AC supply complete all as specified and directed.
supply, Installation, Testing and commissioning in replacement of 6 Watt ceiling/Wall mounted two way Speaker metal box as required with built in 100V/70V transformer complete all as specified and directed.
Supply, Installation, Testing and commissioning in replacement of fire fighter telephone handset/ Microphone for announcement with jack/RJ 11 Telephone socket complete all as specified and directed.
Supply and laying in replacement of public Address wire/speaker cable 2 core, 2 pair armoured speaker cable 1.5sqmm 2 core cable ATC copper conductor PVC insulated core twisted PVC inner seathed armoured outer jacket complete all as specified and directed.
Supply, Installation, Testing and commissioning in replacement of Single master and 8 way slave for talk back system as required complete all as specified and directed.
M&L in replacement for Steel conduit of size 20 mm on wall/ceiling with clamps, screw and all connected items complete all as specified and directed.
M&L in replacement for Steel conduit of size 25mm on wall/ ceiling with clamps screw and all connected items complete all as specified and directed.
Disconnection of existing NOVEC-1230 (ISO Name) gas cylinder transport upto the workshop to carried out Hydro test as per BS Norms after drain out of existing cylinder and refixing the same after Hydro test & refilling of gas on existing location as directed. NOTE- Contractor should produce the authentic test certificate as directed by Engr-incharge & gas should be mesured in separate item.
S&F in replacement of Hydro valve as per existing/ sample kept in office complete all as specified and directed.
Supply only of NOVEC 1230 Fluid.
S&F in repleacement NOVEC 1230 fluid flooding panel with auto & manual interchanin as per existing panel complete all as specified and directed.
Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage capacity 180 ltr and nominal cooling capacity 150 ltr as complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation 170V to 250V with accuracy of 2.5% and capacity of 2.0KVA as complete all as specified and directed.
M&L for wiring for circuit/submain wiring alongwith earth wire with the 2 runx 2.5 sqmm and one run of 2.5sqmm as earthing continuity FRLS PVC insulated copper conductor, single core cable in surface/recessed as complete all as specified and directed.
Supplying and fixing modular switch 15 Amps including modular plate and switch box and incl connection as complete all as specified and directed.
Supplying and fixing modular socket outlets 15 Amps including modular plate and switch box and incl as complete all as specified and directed.
Flint India
Continental Engineers and contractors
Malkit Singh and Bros
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .