Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC | ₹4.6 Cr Quoted ₹4.7 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹4.9 Cr+₹25.6 L (5.47%)Rejected-AOC D NO 39 9 99 56 FLAT NO 501 SRI SAMPATH RESIDENCY MURALINAGAR VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹4.9 Cr+₹25.6 L (5.47%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹5.0 Cr+₹34.5 L (7.38%)Rejected-AOC FLAT NO 5 10 3 73 6 AMAR APARTMENTS TEACHERS COLONY EAST MARREDPALLY SECUNDERABAD 500026 | SECUNDERABAD | HYDERABAD | TELANGANA | 500026 | ₹5.0 Cr+₹34.5 L (7.38%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹5.0 Cr+₹35.9 L (7.67%)Rejected-AOC | ₹5.0 Cr+₹35.9 L (7.67%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹5.3 Cr+₹60.4 L (12.9%)Rejected-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARA HILLS HYDERABAD 500 034 | HYDERABAD | TELANGANA | 500034 | ₹5.3 Cr+₹60.4 L (12.9%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹5.4 Cr
EMD Value
₹6.0 L
Closing Date
5 Nov 2022, 6:00 pmClosed
Chief Engineer Chennai Zone
Chief Engineer Chennai Zone, Island Grounds, Chennai 600009
ADDN/ALTN TO MD ACCN AT ARTY CENTRE GOLCONDA HYDERABAD
2022_MES_556789_1
89066/E8
Open Tender
Civil Works
Item Rate
456 days
SECUNDERABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Garrison Engineer Golconda
₹6.0 L
Yes
6 Dec 2022
10 Oct 2022
7 Nov 2022
10 Oct 2022
5 Nov 2022
31 Oct 2022
11 Oct 2022 - 21 Oct 2022
Amount
B/R ITEMS
Dismantling of Asbestos cement (corrugated, semicorrugated etc.) sheets in roof coverings complete all as specified and as directed.
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed.
Dismantling of battens for tiles, shingles etc. of any size including tilting fillets, spaced exceeding 15cm complete all as specified and as directed.
Dismantling unframed work of timber scantling of cross sectional area 40 sq.cm and over in section, in any position complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Demolition of brick work or precast cement concrete block walling or stone masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facing etc., complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid and pointed in any mortar including removal of debris to outside MD land etc., complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description of any position not otherwise specfically provided for as in sunken floors & floor etc including removal of debris to outside MD land.etc., complete all as specified and as directed.
Dismantling of floor hearth or wall tiling or terrazzo flooring including cement mortar bedding (but not backing) and removing rubbish off the premises to outside MD land etc., complete all as specified and as directed.
Demolition of Reinforced cement concrete of any description such as Roofs, floors beams, staircases, landing, chajjas etc., and similar suspended work in any position including reinforcement cut as required to facilitate demolition, breaking up concrete, seperating reinforcement steel bars (scrap), removing to store for taking credit and removal of debris outside the MoD land complete all as specified and as directed
Dismantling timber scantlings in fillets, rails, post, rafter, purlin etc under 40 Sqcm in section in any position unframed work complete all as specified and as directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm for embedding fencing post and removing surplus soil to a distance not exc. 50m and making good surface all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation or for shafts, wells, cesspit, manholes, sewage lines, laying of pipes/pipe lines etc., n.exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.50 Metre above the starting point complete all as specified and as directed.
Material and labour for Hardcore of gauge not exc. 63mm using Broken stone or boulders, deposited spread and levelled in layers not exceeding 15cm thick, watered and well rammed to a true surface complete all as specified and as directed.
Material and labour for PCC 1:4:8, type D2 using 40mm graded aggregate as in foundation and mass concrete complete all as specified and as directed.
M & L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded complete all as specified and as directed.
M&L for reinforced Cement Concrete (Design mix) Grade M25 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and as directed.
M&L for reinforced Cement Concrete (Design mix) Grade M25 (using 20 mm graded stone aggregate) as in lintel bands, floor/roof beams and cantilevers etc. and the like complete all as specified and as directed.
Supply only Integral Water Proofing Compound conforming to IS:2645-2003 complete all as specified and as directed.
Material and labour for providing precast cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate and set in CM 1:6 as in cooking platform, landings, manhole cover slabs, chullah hoods, Chajjas, water troughs, shelves, and similar articles with plain faces complete all as specified and as directed. Note: Reinforcement bars shall be measured and paid separately.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and as directed.
M&L for Random rubble masonry built in cement Mortar 1:6 uncoursed, well bonded, bedded and solidly hearted complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like 15mm thick including bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Drilling round holes, drill or cut in second class hardwood diameter not exc 15 mm dia and complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves including supports etc for rough finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), etc for rough finished surfaces of flat concrete complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete etc complete all as specified and as directed.
M&L for 2nd Class hardwood plain fillets, square or triangular in section, clean swan, secured with nails or brads, cross sectional area exc 13 Sqcm but not exc 25 Sqcm complete all as specified and as directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) complete all as specified and as directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) and as removing complete all as specified and as directed.
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Supply and fix 2nd class Hard wood factory made plain framed, 35mm thick panelled shutters (two panel) with lock rail and panel of 9mm ply BWP commercial type or 12mm thick veneered particle board with commercial veneering on both faces, the size of rail and stile are as per IS 1003 (part I) kiln seasoned and chemically pressure treated and fitted to chowkats complete all as specified and as directed.
Supply and Fix 2nd class hardwood factory made 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc, size of members as specified in SSR Part 1 section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc., complete all as specified and as directed.
S & F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick(stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification& drawing .
Supply and Fix Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples to frames etc., complete all as specified and as directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F for Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 300 mm complete all as specified and as directed.
S&F 170mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S & F 125 mm long floor door stopper of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 and fixed to PVC Doors complete all as specified and as directed.
S&F 125 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F 125 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S & F brass chromium plated tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges of brass chromium plated complete all as specified and as directed.
S & F Continuous (piano) hinges,mild steel, bright finish or electro galvanised, Width of flaps (when open) in 30 mm etc complete all as specified and as directed.
S & F for Extruded aluminium alloy handles, fabricated type,anodised, Size of handle in 75 mm,etc complete all as specified and as directed.
S & F brass 2-levers locks for cupboard, grade I of size 50mm complete all as specified and as directed.
S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished and brass polished complete all as specified and as directed.
S&F curtain rod 25mm dia MS decorative type powder coated complete all as specified and as directed.
S&F 25 mm dia MS brackets to curtain pipe, decorative type powder coated complete all as specified and as directed.
M&L for MS framed structure roof trusses (framed), trussed, purlins, crane gantries and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and as directed.
M&L for Steel work in tubular trusses & vertical post and facia/drop including special shaped washer etc using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and as directed.
S & F MS screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm. but not exc 15cm complete all as specified and as directed.
Material and labour for Mild steel TMT bars of quality conforming to Fe-500D in reinforcement, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for Mild steel TMT bars of quality conforming to Fe-500D, 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed.
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-250) quality-A, etc complete all as specified and as directed.
S & F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet 1.60 mm, etc complete all as specified and as directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 410-O 0r Fe 310-O complete all as specified and as directed.
M & L for double shutter box type steel window with side hung shutters (Glazed and gauzed) including guardbars, projecting type hinges with steel handle and peg stay complete with or with out glazing bars dovtailed or welded complete all as specified and as directed.(Note Glazed and gauged shutter including guard bars will be measured as one unit. glass pane and wire mesh will be measured and paid separately)
S&F of steel ventilators box type with top hung shutters (glazed and gauzed) including guardbars at top hung area and bottom half fixed type including hinges, steel peg stay complete all as specified and as directed.
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed surface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 24x24mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 2mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 8mm to 9mm thick gypsum board of size 600mm X 600mm with rear side aluminium foil and front side PVC lamination, complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement fixed with self drilling/self tapping screw with EPDM seal etc., complete all as specified and as directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws with EPDM seal etc complete all as specified and as directed.
S&F 12mm veneered decorative plywood grade I (with BWR resin) with decorative face veneers on both faces, fixed with screw to timber frame work as in repairs complete all as specified and as directed.
S&F of 18/19mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with nails to timber frame work as in repairs complete all as specified and as directed.
M&L 75mm thick PCC 1 : 3 :6 Type C2 (using 40mm graded stone aggregate) as in sub base of floors laid in alternative bays including necessary form work complete all as specified and as directed.
M&L for 25mm thick cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in sub-base and finished surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc., laid over and including 15mm thick cement screed bed or bedding layer in CM (1:6), tiles jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, compelte all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc., laid over and including 15mm thick cement screed bed or bedding layer in CM (1:6), tiles jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, compelte all as specified and as directed.
M & L for glazed ceramic tiles in vetical surfaces, size of tile 300mmx200mmx7mm thick laid over 10mm thick back coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, complete all as specified and as directed.
M&L for Vitrified Ceramic tiles, light shade, 10mm thick (Square or rectangular) polished, area of each tile not exc 0.36 Sqm as in floors etc., and laid over and including cement screed bed or bedding layer in CM (1:6), 15mm thick and jointed in neat cement slurry and pointed in white or coloured cement to match using light shade coloured tiles complete, all as specified and as directed.
M&L for Vitrified Ceramic tiles 10mm thick (Square or rectangular) polished, area of each tile not exc 0.36 Sqm as in skirting / dados etc laid over and including 10mm thick back coat in CM(1:4) and jointed in neat slurry and pointed in white or coloured cement to match using light shade coloured tiles complete, all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6 type C2 (Using 40 mm graded granite stone aggregate) as in plinth protection finishd even and smooth with out using extra cement complete all as specified and as directed.
M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors including 15 mm thick screed bedding layer in CM 1:6 complete all as specified and as directed.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) surface finished even and smooth without using extra cement as in flooring complete all as specified and as directed.
Taking down cement plaster on wall of any description incl racking out joints for key, scrubbing with water etc. complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortor 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 3% by weight of cement (IWPC measured and paid separately) complete all as specified and as directed.
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 5mm thick in CM (1:3) as in ceilings, concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete and all as specified and as directed.
M&L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of walls including 3mm thick wall care putty on wall and preperation of surface complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls and applying Two coats of cement based paint complete all as specified and as directed.
M&L for preparation of new ceiling surfaces and applying three coat of white wash, complete all as specified and as directed.
M&L for complete removal of existing treatment and applying two coats oil bound distemper over a coat of alkali resistant primer on old surface of walls including 3mm thick wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint on walls surfaces complete all as specified and as directed.
S & F 4 mm thick Sheet glass, ordinary quality, glazing with oil putty or wooden beading in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 4mm thick figured glass, pin head type, glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Taking down 15mm bore steel tubing and connections in any position, Complete all as specified and as directed.
Taking down 20mm bore steel tubing and connections in any position, Complete all as specified and as directed.
Supply & fix 15 mm bore galvanized steel water tubing medium grade complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc complete all as specified and as directed.
Supply & fix 20 mm bore galvanized steel water tubing medium grade complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc complete all as specified and as directed. Note for item 100&101: Cutting chases and making good shall be measured and paid under relevant item.
S&F rotational moulded polyethylene water storage tanks triple layered (one piece moulded cylindrical vertical with closed top) of 500 ltrs capacity hoisted and fixed in position all as specified including dismantling old tank complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks triple layered (one piece moulded cylindrical vertical with closed top) of 1000 ltrs capacity hoisted and fixed in position all as specified including dismantling old tank complete all as specified and as directed.
S&F 20 mm dia brass ball valve, high pressure with polythene float and fly-nut complete, screwed for iron pipe or brass ferrule fixed in repair complete all as specified and as directed.
S&F in repair 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F in repair 15mm bore Bib taps, chromium plated cast copper alloy but fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs 15 mm dia fancy type stop valves/ angle cock chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F in repair 125mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union fixed complete all as specified and as directed.
S&F stainless steel Kitchen sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including necessary PVC outlet pipe and coupling complete all as specified and as directed.
S & F in repair stainless steel plate rack 31" X 36" X 10" made up of 1mm thick sheet (Non magnetic) complete all as specified and as directed.
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) with 110mm dia PVC SWR 'P' or 'S' trap, fixing of cistern, complete including provision of cement concrete all as specified and as directed by Engr-in-Charge.
S&F for wash down water closet (pedestal pattern) complete white with plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern incl pedestal pan and trap, and connection to drain (or outgoing pipe) complete all as specified and as directed.
S&F for vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP fancy type pillar tap, 01 Nos 32mm waste coupling , one pair of MS bracket, cutting for and pinning in ends of brackets complete all as specified and as directed.
Supply and fix PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and as directed.
S&F in repairs PVC connection 15mm dia, 45 Cms long with brass ferrules on both ends fixed complete all as specified and as directed.
Supply and Fix PTMT Shelf of weight not less than 300 gms with soap dish (tray) fixed with and including Chromium plated brass screws and wooden / plastic cleats etc., complete all as specified and as directed.
S & F UPVC( SWR ) pipes 110mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down existing pipe complete all as specified and as directed.
S & F UPVC( SWR ) pipes 75mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed.
S&F in repair UPVC (SWR) bends any radius 110mm bore complete all specified and as directed.
S&F in repair UPVC (SWR) bends with access door any radius 110mm bore complete all specified and as directed.
S&F UPVC (SWR) junction single (single T) equal or unequal with access door of bore 110mm complete all specified and as directed.
S&F UPVC(SWR) vent cowl 110mm bore complete all specified and as directed.
S&F UPVC (SWR) bends any radious 75 mm dia complete all specified and as directed.
S&F UPVC (SWR) bends with access door any radious 75 mm dia complete all specified and as directed.
S&F UPVC (SWR) junction single (single T) equal or unequal of bore 75mm complete all specified and as directed.
S&F UPVC (SWR) junction single (single T) equal or unequal with access door of bore 75mm complete all specified and as directed.
S&F in repair UPVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F for PVC waste pipe for urinal/WHB with fitting etc 38 mm dia. 60Cm long complete all as specified and as directed.
M&L for forming 12 mm thick expansion joints for 40 mm concrete slab thickness filled with preformed bituminous filler and top 30 mm primed and sealed with sealing compound grade A complete all as specified and as directed.
S&F in repair health faucet with spray jet (hand shower) chromium plated with 1.0metre long easy flex tube 8mm dia with wall hook as per Cat No.ALD-CHR- 583 of Jaquar or T9940A1 of Parryware or F-8030105-AB of CERA or equivalent of other specified makes, screwed for 15mm stop cock etc., complete all as specified and as directed.
S&F in repair brass CP mixer 15mm dia for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S&F in repair two way bib tap / cock 15mm bore, Brass, chromium plated, fancy type screwed down for iron pipe and fixed complete all as specified and as directed.
E/M ITEMS (INT ELECTRIFICATION)
Taking down carefully existing Unserviceable copper/aluminium point wiring of any description/ type/ size of (light/fan/socket/call bell/two way/ Power point) on TW batten/conduit complete including fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells and removing the materials to store for keeping in safe custody for reuse at site or for taking credit including making good the disturbed surfaces of walls/floors/ceilings etc. complete all as specified and as directed.
Material and labour for point wiring complete with two runs of 1.5 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, copper conductor FRLSH cable of 1100V grade conforming to IS - 694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked of suitable dia (not less than 20mm dia) with conduit accessories suitable for concealed wiring on stone / brick masonry wall, roof etc, including provision of fabricated branded pressed steel terminal box of suitable sizes made out of sheet of 1.6mm thickness duly painted inner and outer side by anti-corrosive paint for housing the switches, sockets, fan regulator etc and covered with 3 mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc., complete concealed in walls and provision of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and as directed for One light / fan point controlled by one one way switch.
All as per item No. 137 above but One 3 pin 6 Amps switch socket outlet controlled by one switch on independent board
All as per item No. 137 above but One 3 pin 6 Amps switch socket outlet controlled by one switch on the same board
All as per item No. 137 above but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 sqmm complete all as specified and as directed.
All as per item No. 137 above but for one light point controlled by two, two way switches complete all as specified and as directed.
Material and labour for point wiring complete with two runs of 1.5 Sqmm (for Phase and Neutral) PVC insulated unsheathed multistranded, copper conductor FRLSH cable of 1100V grade conforming to IS - 694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked of suitable dia (not less than 20mm dia) with conduit accessories suitable for concealed wiring on stone / brick masonry wall, roof etc, including provision of fabricated branded modular pressed steel terminal box of suitable sizes made out of sheet of 1.6mm thickness duly painted inner and outer side by anti-corrosive paint for housing the modular switches, sockets, fan regulator etc and covered with 3 mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc., complete concealed in walls and provision of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and as directed for One light / fan point controlled by one one way switch.
All as per item No. 142 above but for one 3 pin socket outlet 5 Amp independent complete all as specified and as directed.
All as per item No. 142 above but for one 3 pin socket outlet 5 Amp on same board complete all as specified and as directed.
All as per item No. 142 above but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 sqmm complete all as specified and as directed.
All as per item No. 142 above but for one light point controlled by two, two way switches. Note for item 137 to 146: Cutting chases and making good shall be measured and paid separetely under relevant item.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and as directed at site.
Supply and fix Switch piano flush type single pole, two way 5 Amp complete all as specified .
Supply and fix Switch socket outlet combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed at site.
Supply and fix Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed at site .
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, isolated body with face bakelite 65 x 50mm, 3 terminals complete all as specified and as directed.
Supply and fix lamp holder insulated body with back plate suitable for battern fittings complete all as specified and as directed.
Supply and fix Electronic fan regulator stepped type with five step 240 volts suitable for 1200/1400 mm sweep AC ceiling fan complete all as specified and as directed.
Supply and fix Bell push flush type piano 5 Amp complete all as specified and as directed.
Supply and fix Bell electronic 230 volt ,AC single pole complete all as specified and as directed.
S&F Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed.
S&F Modular switch, single pole, two way, 6 Amps one module complete all as specified and as directed.
S&F Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed.
S&F Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.
S&F Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed.
S&F Modular bell push with indicator 5 Amps one module complete all as specified and as directed.
S&F Modular stepped type electronic fan regulator 220 volts, 120Watt complete all as specified and as directed.
Supply and fix 10 watt LED Bulb complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Fixing only LED lights fittings of any type and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Note:Serviceable tube lights obtained from item No.136 herein before shall be utilized.
S & F LED light fittings, 1x10 watts bulk head luminaires etc complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose all as specified
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20A complete all as specified and as directed.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 8way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW08 of Havells or 811808 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 12way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW12 of Havells or 811812 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) TPN, 4 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDNTHCDPW04 of Havells or 5076 70 of Legrand or 811840 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB TPN as incomer and 4P MCBs as outgoing and total number of modules equal to 4 + 12, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply and fixing 415V, 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP with 40 to 100 amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and current carrying capacity 5-32A in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and nuetral and current carrying capacity 32A in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Taking down existing sub main wiring of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc., complete all as specified and as directed.
M&L for sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 4.0 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings for concealed conduit complete. Note : (i) Two single core cable and one run of earth copper cable and including PVC conduct will be measured and paid as one unit length
M & L for making / drilling hole to RR masonry/brick wall of any thickness for fixing exhaust fan of 300mm dia and fixing 2 Nos of precast RCC circular frame and filled gap with PCC (1:2:4) incl plastering, white washing etc for making good and match to existing wall surface complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
S&F 25mm dia Rigid non-metallicPVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for carrying Telephone wire/Data cable etc., complete all as specified and as directed.
Disconnecting and taking down the existing unserviceable earthing and Material and labour and Earthing complete with 6.0mm galvanized steel earth plate electrode of size 600mmx600mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less 1.5mtr below normal ground level surrounded from all sides by 15cm thicked packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 as MES Schedule (Part I) (2009) connected to Earth test point/ main switch/ DB all as specified including 15mm bore medium grade GI protection pipe upto 7.5 metre long for GI earth wire including PCC (1:3:6) type C1 pit with 40mm thick precast RCC (1:2:4), type B1 cover reiforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as speciofied and as directed.
E/M ITEMS (EXT ELECTRIFICATION)
Taking down existing service wire of any description and size including earth wire, House service bracket and making good the disturbed surfaces of walls, floors etc.
Taking down existing UG cable of any description and size and making good the disturbed surfaces of walls, floors etc.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed. Note for item 189 to 191: Excavation & earth work shall be measured and paid under relevant items.of this sch.
Supply and spread approved dry river sand for cable cushioning including watering and consolidation, laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose
Supply and lay burnt Bricks, old size, sub class "B" of size 230 x 115 x 75mm, laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable etc., complete all as specified and as directed.
Supply and lay GI tubing 40mm bore , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
Supply and lay GI tubing 50mm bore , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply, installation, test and commissioning of Loop in and loop out Distibution panel outdoor type consisitng of three phase busbar of capacity 100A for phase and neutral and provn for incomming MCCB- 1 No and outgoing MCBs - 11 Nos, including undrilled gland plate for termination of cables, indication lamps, base frame made out of angle iron 50x50x6mm and necessary foundation with PCC 1:3:6 type C2 complete all as specified and directed.
Supply, installation, test and commissioning of Loop in and loop out Distibution panel outdoor type consisitng of three phase busbar of capacity 100A for phase and neutral and provn for incomming MCCB- 1 No and outgoing MCCBs - 3 Nos, including undrilled gland plate for termination of cables, indication lamps, base frame made out of angle iron 50x50x6mm and necessary foundation with PCC 1:3:6 type C2 complete all as specified and directed. Note: MCCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCCB, 3 Pole, 25 to 100 Amps, 415Volts with breaking capacity 16kA, (lcs=50%lcu) with Fixed Thermal setting, conforms to IEC 60947 - II, suitable for isolation, fixed short circuit setting, fixed overload setting all as per Cat 830002 - 830008 of INDOASIAN or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and nuetral and current carrying capacity 6-32A complete with connection testing and commissioning.
Material and labour for Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm, 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth lead strip of size 32 x 6mm as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB all as including (1:2:4), type B -1 cover reinforced testing on completion with and including 40mm bore medium grade GI protection pipe upto 7.5 meter long for GI earth strip including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC with 12mm dia MS bars @ 150 mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
HOT WATER SUPPLY
Supply installing and testing vertical type storage electric water heater (Geyser) of 25 ltrs capacity, Tank made of ultra thick super cold rolled steel plates with high density PUF insulation, 2 KW, 230 V, single Phase, 50 Hz, AC, BEE 5 star rated including multifunction safety valve, Rated Pressure ≥ 0.8 Mpa and incl integrated shock safe plug & 2 Nos anchor fasteners of size as per manufacturer instructions grouting and fixing and making good the distributed surface complete electrical and water supply connection using steel braided hose for inlet and outlet connections complete all as specified and as directed by the Engr-in-Charge.
Supply and Fix Bib taps, Brass, chromium plated, fancy type alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm Dia complete all as specified and as directed.
ARP ENTERPRISES
B.N.S Constructions
Sri Lakshmi Enterprises
SRICO PROJECTS PVT LTD
Dwarka Pershad Radhey Ramanlal
power links
Sai construction & services
Mavee Syndicate
R. Wadhumal and Sons
STANDARD AGENCIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .