AE_KCESD_II
OFFICE OF THE ASSISTANT ENGINEER Kolkata Central Electrical Sub-Division II P.W.Dte
Procurement and Installation of 03 Three2 TR Split Type air condition machines for server room 400 sq Ft of W.B G press Alipore unit at Kadapara
2026_WBPWD_5016455_1
WBPWD/AE/14/Q/KCESD/II of 2026-27(2nd call)
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Kadapara
Procurement and Installation of 03 Three2 TR Split Type air condition machines for server room 400 sq Ft of W.B G press Alipore unit at Kadapara
4 documents required · 4 mandatory
₹4,417
19 Aug 2026
7 Jul 2026
20 Aug 2026
7 Jul 2026
18 Aug 2026
13 Jul 2026
13 Jul 2026 - 20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete
in all respect as per the direction of EIC.(Make-O-General/Mitsubishi(Heavy Duty)/Daikin)
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum)
Minimum ISEER - 5.0, BEE level - 4-Star(min) | 3 | nos. | - | - |
| 2 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell
elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation.[ Make Aroflex / Acoflex] as given below for Suction and Liquid lines, all accessories as per specifications etc.as required :
a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm.[ Make Royku / Totaline/ Mandeep] | 12 | mtr | - | - |
| 3 | b) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm.[ Make Aroflex / Acoflex] | 12 | mtr | - | - |
| 4 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of above AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) ( MK. KEI /Havell's / Polycab / Finolex). | 17 | Rmt. | - | - |
| 5 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports &brackets as per direction EIC. Oriplast / Supreme)
(a) 25mm dia | 22 | mtr | - | - |
| 6 | Charges for lifting of ODUs, IDUs and others necessary items at an height of 2nd floor for installation of Air conditioning system at the server room of W.B.G press | 3 | item | - | - |
| 7 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage for AC machines installation, per storey of building per vertical run. | 6 | storey/ vertical run | - | - |
| 8 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
(a)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (Supply of indoor unit for A.C machine ) | 40 | mtr | - | - |
| - | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5 sqmm | 4 | Each | - | - |
| - | b) 4 sqmm | 8 | Each | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.66 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
BOQ_5085955.xls
BOQ • 0.29 MB
2911.pdf
Tender Documents • 0.51 MB
DC3.pdf
PDF • 0.66 MB
DC2.pdf
PDF • 0.66 MB
DC.pdf
PDF • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .