AE_KCESD_II
OFFICE OF THE ASSISTANT ENGINEER Kolkata Central Electrical Sub-Division II P.W.Dte
Procurement and Installation of 03 Three2 TR Split Type air condition machines for server room 400 sq Ft of W.B G press Alipore unit at Kadapara
2026_WBPWD_5016455_1
WBPWD/AE/14/Q/KCESD/II of 2026-27(2nd call)
Open Tender
ELECTRICAL WORKS M/R
7 days
Kadapara
Procurement and Installation of 03 Three2 TR Split Type air condition machines for server room 400 sq Ft of W.B G press Alipore unit at Kadapara
4 documents required · 4 mandatory
₹4,417
7 Jul 2026
7 Jul 2026
22 Jul 2026
7 Jul 2026
20 Jul 2026
13 Jul 2026
13 Jul 2026 - 20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete
in all respect as per the direction of EIC.(Make-O-General/Mitsubishi(Heavy Duty)/Daikin)
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum)
Minimum ISEER - 5.0, BEE level - 4-Star(min) | 3 | nos. | - | - |
| 2 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell
elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation.[ Make Aroflex / Acoflex] as given below for Suction and Liquid lines, all accessories as per specifications etc.as required :
a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm.[ Make Royku / Totaline/ Mandeep] | 12 | mtr | - | - |
| 3 | b) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm.[ Make Aroflex / Acoflex] | 12 | mtr | - | - |
| 4 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of above AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) ( MK. KEI /Havell's / Polycab / Finolex). | 17 | Rmt. | - | - |
| 5 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports &brackets as per direction EIC. Oriplast / Supreme)
(a) 25mm dia | 22 | mtr | - | - |
| 6 | Charges for lifting of ODUs, IDUs and others necessary items at an height of 2nd floor for installation of Air conditioning system at the server room of W.B.G press | 3 | item | - | - |
| 7 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage for AC machines installation, per storey of building per vertical run. | 6 | storey/ vertical run | - | - |
| 8 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
(a)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (Supply of indoor unit for A.C machine ) | 40 | mtr | - | - |
| - | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5 sqmm | 4 | Each | - | - |
| - | b) 4 sqmm | 8 | Each | - | - |