Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.1 L+₹1.7 L (5.21%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹36.4 L+₹3.9 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹37.8 L+₹5.4 L (16.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹38.5 L+₹6.0 L (18.5%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
14 Apr 2020, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
OUTSOURCING OF SERVICES FOR HT E/M INSTALLATIONS AND REPAIRS MAINTENANCE OF HT/LT EXTERNAL ELECTRICAL EQUIPMENTS AND ALLIED WORKS AT ATC DEVATALAGUTTA KANCHANBAGH, HYDERABAD
2020_MES_333356_1
GE I KBAGH TOKEN 88 OF 2019 2020
Open Tender
Civil Works
Item Rate
330 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
14 May 2020
12 Mar 2020
17 Apr 2020
12 Mar 2020
14 Apr 2020
26 Mar 2020
12 Mar 2020 - 19 Mar 2020
Amount
Outsourcing of services for Operations for 11 KV /0.433 V at MRS at ATC DMRL having 4 Pole structure - 3 Nos, transformers - 6 Nos, 2 pole structures - 3 Nos, LT panel board - 8 Nos, HT panel - 02 Nos and connected HT/LT lines/ cables, takeover point of 11 KV OH line near Mallapur, HT 11 KV VCBs with connected two feeders of HT cables from RCI MRS to ATC Devatalagutta, patrolling the connected lines once in two days, attending & rectification of fuse/Jumper, repairs of calls of HT/LT for restoration of electric supply on top priority during breakdown in ATC complex including DSC Md Accn and connected feeder from RCI and Maintenance of HT/LT cables, control cables, LT panel boards for sub station lighting, earthing pits of all the equipments (including regular watering) & plants, carrying out regular testing of the equipments and maintaining each of the earth testing register/insulation testing register/Oil testing registers, log book with duty roster/ attendance register records of the electric supply with all parameters as described at the sub station and daily maintenance of the complete surrounding area of the Main Sub Station. As and when the supply fails/ restore from RCI or breakdown shall be informed to the Main Sub Station incharge within 05 Minutes of breakdown, complete all as directred. Note:- The job shall be maintained by employing one Semi-skilled (electrician) and one unskilled (helper) in each shift for 3 shifts on all days including Sundays and holidays as given below :(a) First shift 0600 hrs to 1400 hrs (b) Second shift 1400 hrs to 2200 hrs (c) Third shift 2200 hrs to 0600 hrs
Outsourcing of services for pump house, DG Set 125 KVA at Devatalagutta, pumping to bldg servicing tanks/over head tank, and operation of standby DG set for pump house, maintaining record of all installations, and running of 06 borewells and proper water supply distribution to all security post and underground sump in ATC area, Fire Fighting Installation, bore wells at DSC Md Accn including proper distribution of water supply to complete area including operation of valves, pumps & operating of Reverse Osmosis Plant system 200 LPH for drinking water including operation of valves etc complete by employing 01 PHO(Semi-skilled in each shift) (for three shifts) (1st shift 0600Hrs to 1400 Hrs, 2nd Shift 1400 Hrs to 2200 Hrs and 3rd shift 2200 to 0600) and one unskilled (helper) in general Shift (0900 Hrs 1700 Hrs) on all days including Sundays and holidays complete all as directed Note :- Carrying out regular checks and services to the plants/ equipments for upkeeping of pump house and ensure serviceability of all the equipments including undertaking routine checks like replacement of gland packing in all pumps valves, checking of electrcial control panel, repalcement of gland rope to pumps, gaskets, "O" rings, nuts, bolts and washers of any type and of any size including thorough cleaning of equipment/ machinery.
Note: (i) In case of requirement, tradesmen provided for one area may be utilized in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (ii) Rate quoted is deemed to be included for leave reserve/Off of the staff employed.(iii) The rate quoted shall be deemed to include the cost of uniform, Shoes, Helmet, Belt and insulation gloves for tradesmen employed. (iv) The necessary Tools & Plants shall be provided by the contractor. (v) Minimum wages to the employees to be paid for all working days of the month including reliver (wages as declared in BOQ Notes) (vi) Each employee should be facilitated with adhoc bonus privilage as applicable in accordance with Govt Of India and the same be deemed be incuded in the quoted rate. Documentry proof duly signed by contarctor/ contractor's representative and individual to be forwaded. (vii) Departmental equipments of each building /installations like transformers, HT/LT panel boards, RMU, 6/4/2/1-pole structures equipment, Electric panels and other misc E/M items and its accessories copper & brass materials etc., shall be under safe custody. In case of theft of any item, recovery shall be made from the contractor as per direction of Engr-in-Charge. (viii) In case of absence of operator double the rate quoted shall be recovered.
(ix) During operation of installations/equipments/tree trimming of respective electrical power lines/Electrical panels should be isolated properly. Necessary safety precautions / safety devices to be adopted and the quoted rate is deemed to be included for same & in case of any eventuality to tradesmen/Operators, the contractor is fully responsible for them. (x) The contractor will adhere to pay monthly payment cycle to the employees irrespective of RAR/Funds availability with department failing which will be laible to pay 5% penalty of monthly quoted rate as per CA in the next RAR.(xi) Temporary laying of LTUG cable of any size and any lenth for restoration of supply during break down / other requirement deemed to be included in the above quoted rate.(xii) Uniform,safety shoes shall be provided by the contractor. (xiii) Rate quoted shall be deemed to include for restoration of jumpers,HT fuses using existing resourses during short circuits due to wind/rain, to restore the supply for incoming and out going feeders.
Inspection of defective cable to locate the fault using cable fault Locator machine complete all as directed.
Servicing to existing 11000 Volts outdoor type GOD 200/400 amps duly applying petrolium jelly and oiling of parts after cleaning the contact off rust and carbon deposit including tightening of all the loose connections and making good for operation complete all as directed.
Opening the HT cable termination box at both side and after taking shutdown and disconnecting the HT cable connections from both ends of any size, Meggering of cable for establishing the fault, return back and testing commissioning including dressing the end termination with bolts/ washers and cleaning with CTC complete all as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick, using soil complete all as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed.
Supply and spreading of natural, clean, dry river sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as directed. Note:- Punned thickness only shall be measured for payment purpose.
M&L for laying common burnt old size sub class 'B' brick, of size 230 x 115 x 75 mm in trenches for cable protection complete all as directed.
Cutting the road to 60cm depth and 45cm wide for laying cable and making good the disturbed / excavated ground by filling the excavated material and top 300 mm by filling with PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) to match with level of road complete all as directed
Dismantling the defective jumper, supplying and connecting new jumper with ACSR conductor with proper binding to HT over head line conductor including binding wire, bolts, nuts, washers and suitable aluminium lugs for HT over head line, structures complete all as directed.
M&L for insulation of bus bar of HT 11 KV koisk feeders installed at different locations from ATC to RCI MRS including replacement of old busbar insulators with new insulators after carrying out necessary disconnection of existing cable connections and reconnecting after completion of insulation complete all as directed. Note:- Three sleeves of bus bar including insulator will be measured as one Job.
Cutting and trimming of tree branches of any girth and of any size, touching the overhead lines and clearing to a distance of 1.5 mtr length on both side of OH line with in a gap of span 30 mtrs each, disposing the same for clearing the site complete all as directed.
Restringing of LT over head ACSR conducotor from pin,disc,shackle insulators and binding the conductor to insulator with suitable binding wire complete all as directed.
Supply, stringing and fixing in position of high tension/ low tension overhead line on existing pole with continuous Aluminum Conductor Steel Reinforced (ACSR) of any size including taking down unserviceable ACSR conductor complete all as directed.
M&L for HT 11 KV, air break switch,gang operated,triple pole, mechanically operated, mounted on insulator and steel frame, with oprating mechanism worked from ground level suitable for 11KV supply and current rating upto 400Amps including taking down old unserviceable air break switch complete all as directed.
S&F 11 KV Grade, lightning arresters, expulsion type (set of three) with all fittings, transmission class, 11000Volts discharge capacity 65KA including taking down old unserviceable lightning arrester complete all as directed.
M&L for cable end jointing kit for 11000 Volts grade cable heat shinkable indoor type joint complete with jointing materials and accessories suitable for 3 core 120 sqmm to 185 sqmm including taking down unserviceable jointing kit complete all as directed.
All as per srl Item No.19 here-in-before but 3 core 240 sqmm complete all as directed.
All as per srl Item No.19 here-in-before but 3 core 95 sqmm complete all as directed.
M&L for cable end jointing kit for 11000 Volts grade cable heat shinkable outdoor type joint complete with jointing materials and accessories suitable for 3 core 120 sqmm to 185 sqmm including taking down unserviceable jointing kit complete all as directed.
All as per srl Item No.22 here-in-before but for 3 core 240 sqmm complete all as directed.
All as per srl Item No.22 here-in-before but for 3 core 95 sqmm complete all as directed.
M&L for Cable jointing kit for Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm including taking down unserviceable jointing kit complete all as directed.
All as per Item No.25 here-in-before but 3 core 120 to 185 Sqmm complete all as directed.
All as per Item No.25 here-in-before but 3 core 240 to 400 Sqmm complete all as directed. Make for item No. 19 to 27 : Denson/3M/Rhychem
Supply and laying, testing and commissioning of LTUG cable PVC insulated, screened PVC bedded, galvanisized steel strip wire armourd electric power cable 1100 volts grade with stranded aluminium conductor including taking down out unserviceable burnt out cable complete all as directed of the following sizes :-
4 core x 10 sqmm cable
4 core x 16 sqmm cable
3.5 core x 50 sqmm cable
Taking down high pressure SV/ MV/ MH lamp fitting of capacity 70/ 150/250W after dismantling from any height of pole/ walls/ any location and detecting the fault in the fitting by checking the accessories and wiring and rectifying the fault and refixing the same in its orginal position complete all as directed. Note:- (i) Items like ballast, Lamp, capacitor, ignitor & holder shall be measured separately under relevant items.
S&F in repairs ballast copper wounded type of capacity 70 W suitable for HPSV light fitting complete all as directed.
All as per srl item No.30 here-in-before but 150 Watts ballast complete all as directed.
All as per srl item No.30 here-in-before but 250 Watts ballast complete all as directed.
Supply and Fixing Ignitor of 70/150/250 of street light fitting including taking down old unserviceable ignitors complete all as directed
Supply and Fixing of capacitor suitable for 70/150/250 wattage and type of light fitting including taking down old unserviceable capacitors complete all as directed.
S&F in repairs metal halide lamp of 70Watt capacity complete all as directed.
S&F in repairs metal halide lamp of 150 Watt capacity complete all as directed.
S&F in repairs metal halide lamp of 250Watt capacity complete all as directed.
S&F weather proof cable 2.5 Sqmm aluminium conductor multistranded twin core including taking down old unserviceable cable complete all as directed. Make:- PLAZA/ PARAGON/FINOLEX
S&F Star/Delta starter suitable for upto 10 HP capacity submersible pumps including all internal connections with copper wire testing and commissioning including taking out the old unserviceable star/delta starter complete all as directed Make: L&T/CROMPTON GREAVES/COSMO
S&F DOL starter suitable for 5 to 7.5 HP capacity submersible pumps including all internal connections with copper wire testing and commissioning including takingout old unserviceable DOL Starter complete all as directed. Make: L&T/CROMPTON GREAVES/ COSMO
Taking out & lowering down the submersible pump set of any capacity/ HP/ stage/ make from any depth including disconnecting the water, power supply mains for examination/ repair and lowering down and connecting the same after repair complete all as directed. Note:- (i) Cost of equipment like tripod and chain pulling block/eqpt machine etc required for this job shall be deemed to be included in the quoted rate. (ii) Repairs shall be measured & paid separately under respective items.
Flushing out sand, mud from existing bore well of size 150mm dia upto any depth with air compressor complete all as directed. Note:- Taking down and lowering of submersible pump set shall be measured and paid under relevants items of schedule.
S&F in repairs to submersible pump set of 7.5 HP to 10 HP capacity by, renewing of impeller, bearing, repair to shaft complete all as directed.
Rewinding of motor of submersible pump set with PVC insulated copper wire of existing gauge and quantity for 7.5HP to 10 HP capacity, including re-assembling, testing and commissioning complete all as directed.
S & F in repairs PVC water proof cable of 2.5 Sqmm, 3 core copper conductor suitable for submersible pump set complete all as directed. Make :- FINOLEX/ PLAZA/ PAYAL
S&F in repairs switch piano one way 5 Amps 240 Volts complete all as directed.
S&F in repairs switch socket combination 3 pin 5 Amps complete all as directed.
S&F in repairs switch socket combination 5 pin 15 Amps multipurpose type complete all as directed. Make- ANCHOR/ MARU/ LEADER
S&F ceiling fan regulator electronic stepped type operating on 230V, AC supply including taking down old unserviceable regulators complete all as directed.
S&F electronic choke/ballast suitable for 36/40 watts CFL/ FTL fittings including taking down old unserviceable choke complete all as specified and as directed
S&F of MCB SP 5-32 Amps capacity including taking down unserviceable MCB complete all as directed.
S&F isolator 4 pole 100 Amps 415 Volts including taking down existing unserviceable Isolator complete all as directed.
Taking down unserviceable ceiling fans/Exhaust fans, dismantling, overhauling and replacing the unserviceble spares like Ball bearing/ bushes, capacitors, down rods including flexible copper conductor connections and reassembling/refixing back in the same location, after completion of repairs all as directed. Note : Spare parts shall be measured and paid separately as "supply only"
M&L for rewinding of fan motor of any make/sweep of ceiling fan, exhaust fan/ Pedestal fan of any dia, including removal of existing burnt winding carefully from slots,cleaning the slots with cleaning agents,and rewinding with super enameled copper wire of same guage/type, varnishing complete all as directed.
Supply only of capacitor of 2.5 mfd suitable for any type of fan/exhaust fan/ pedestal fan complete all as directed.
Supply only ball bearings suitable for any type of fan/exhaust fan/ pedestal fan complete all as directed. Make: NBF/NBC/TATA
S&F in repairs LED Street light fitting with IP66 type protection, 90W 50 Hz and housing epoxy powder coated die-casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as directed. Make:- ENDURACITYLINERNEOSL 90W LED 757SASYBOTG of Havells or Technocommercially equivalent in Phillips/CG
S&F in repairs LED flood light fitting with IP66 type protection, 72W, 50 Hz and housing epoxy powder coated die-casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as directed. Make:- JETAPROPLUSFL 120W LED 757LTG OR EQUIVALENT of Havells or Technocommercially equivalent in Phillips/CG
S&F MCCB 400 Amps, 36 KA, 4 Pole Adjustable type with sheet metal enclosure with cable end box for incoming & outgoing cable including taking down old unserviceable MCCB complete all as directed. Make :- STANDARD/ C&S/ INDOASIAN
S&F MCCB 250 Amps, 4 pole, 35 KA, 415 volts, 50 Hz with encloser including taking down old unserviceable MCCB complete all as directed. Make :- STANDARD/ C&S/ INDOASIAN
S&F MCCB 125 Amps, 4 pole, 16 KA, 415 volts, 50 Hz with encloser including taking down old unserviceable MCCB complete all as directed. Make :- STANDARD/ C&S/ INDOASIAN
S&F MCCB 63 Amps, 3 pole, 16 KA, 415 volts, 50 Hz with encloser including taking down old unserviceable MCCB complete all as directed. Make :- STANDARD/ C&S/ INDOASIAN
Supply and filling of transformer oil in transformer plinth/pole mounted including testing complete all as directed . Make:- SERVO / POWER OIL
Dehydration including filtration cleaning of transformer oil in transformer and OCBs indoor / outdoor type at different location of ATC Devatalagutta area by centrifusion machine having minimum capacity 100 to 1000 ltrs including testing oil before and after dehydration complete all as directed.
Servicing of existing 11 KV Breakers (SF6/ VCB type) by disconnection control wiring connection and Opening of all Mechanical & non mechanical parts including charging mechanism, cleaning and removing dust & old oil/grease and applying petrolium jelly & oil to all moving and non-moving parts and repairs of minor parts and check all parts are funtioning including draw out mechanisim, servicing and oiling including tightening of all the loose connections/ parts, replacement of broken side glass/fibre sheet & reconnecting the same and making good for operation complete all as directed.
Earthing with GI earth plate electrode 600x600x6 mm buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge not less than 1.5 mtrs below ground level connected to GI earth strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by40mm dia GI pipe light grade including necessary excavation and earthwork, PCC 1:3:6 type B1 (using 20mm graded stone aggregate) for earth pit and40 mm thick RCC covers 1:2:4 type B1 (using 20mm graded stone aggregate) with 8mm dia TMT bars @ 100mm C/C both way, 20mm dia GI watering pipe medium grade, funnel, mesh, salt, charcoal ,testing ,complete all as shown in electrical plate No. 3 of MES Standard schedule Part - I ,2009 complete all as directed. Note:- GI strip beyond 7.5M length shall be measuerd and paid separately.
Supply & LayGalvanized iron strip 25x4 mm buried in ground/fixed on wall including excavation and earth work & taking down old strip complete all as directed .
M&L for scrapping down and removing of old corroded paint, dirt/ dust/ rust from LT/HT poles of OH lines, four poles/two poles structure complete with cross arms, at any height and of any description, thoroughly with necessary cleaning agent and applying red oxide primer and black & yelow synthetic enamel paint strips of 30 cms each upto 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc. and colourwashing to coping of the pole complete all as directed.
Single HT Poles
Two poles with cross Arms
Four Poles with cross Arms
S&F PVC Junction box of size 250x200x100mm, light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX/HENSEN
Supply and fixing in repairs post top porcelain insulator vitreous brown with GI clamp, nuts, bolts etc suitable for 11000 Volts grade working pressure complete all as directed.
Renewal of insulation of Jumpers 11 KV of any size of required length and colour, lugs, nuts and bolts and connection complete all as directed.
S & F in repairs drop out fuse assembly 11KV (set of three) , 100A, complete all as directed
Repairs and servicing of existing solar system of capacity 500LPD by carrying out necessay descaling of copper tubing in collector panels, repair/ servicing of water circulating pump, repairs to insulation of storage tank including replacement of unserviceable heating elements, copper tubing and allied parts of the system complete all as directed.
S&F Submersible Pump Controller MUG-G15 Fully Automatic Star-Delta starter suitable for submersible pump of capacity 12.5 HP to 15 HP, in sheet Enclosure type MUG-G15 and replacement of existing old & rusted angle iron frame with new angle iron frame pedestal type made out of 2mm thick MS Sheet with 50 x 50 x 6mm thick angle - 02 nos Legs duly embedded in ground with PCC and other end welded to panel board including taking down the old unseviceable control panel board complete all as directed. Make:- L&T Model : SS95983 or equivalent in C&S
Supply and fix in repairs timer switch (tilelite) distribution board 40A, 3pole 230V, Analog type complete as directed Make : Cat Ref TL040DBQ of Indo Asian or equivalent inHavells/CG.
S&F Flurocent tube (T-8) 4 feet length,36/40w including taking down unserviceable tube complete all as directed. Make:CG/Wipro/Surya
Bailing out water and scraping cleaning, the inside surface of 40,00 gallons capacity under ground sump with bleaching powder and removing all type of impurities from water tank. After cleaning 01 coat of disinfectant shall be applied on inner surface of tank at any depth complete all as directed. Note :- (i) Disinfectant shall be approved by the Engr-in-Charge. (ii) Pump for Bailing out water with all provision shall be provided by the contractor at no extra cost.
Supply and Fix in repairs GI column pipe 50mm dia heavy grade of 3 mtr long both end long threaded complete all as directed.
Supply and Fix in repairs LED 20 W 4 feet long, complete all as directed Make: CG/Wipro/Surya
vvcenterprises
BHAGYARAM ENTERPRISES
SUN LIGHT HOUSE
Maruthi international
Indu Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .