Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹6.6 LAccepted-AOC | 1st | Accepted-AOC Lowest Rates |
Tender Value
₹6.3 L
EMD Value
₹12,674
Closing Date
12 Dec 2019, 5:00 pmClosed
Executive Engineer
Executive Engineer, Water Supply and Sanitation Division No.2, Mansa Near Bachat Bhawan, Mansa
Providing and fixing of floating arm Repair of Clear Water Tank
2019_WB_41310_1
MANSA-DIV-2/2019-20/003
Open Tender
Civil Works
Item Rate
90 days
Mansa
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
TIA
₹12,674
26 Jan 2020
2 Dec 2019
13 Dec 2019
2 Dec 2019
12 Dec 2019
2 Dec 2019
Item Wise Description :
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish Carriage of material excluding initial lead of 5 Km (a) Jalalabad Sand (Av. Lead 167 Km) Up to 40 km (C.S.R. Item No. 5.2 (i))
41 km to 60 km
61 km to 150 km
150 km to 167 km
(b) Gagger Sand (Av Lead 320 Km.) from Pathankot Up to 40 km
41 km to 60 km
61 km to 150 km
150 km to 320 km
(d) Bajri (Av Lead 320 Km.) Up to 40 km
41 km to 60 km
61 km to 150 km
150 km to 320 km
Carriage of sand for earth filling a lead of 5 km (C.S.R. Item No. 5.2)
Earth work in excavation in foundations, trenches etc.in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation (C.S.R. Item No. 6.6)
Earth filling :- Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres (C.S.R. Item No. 6.8 (a) (i))
Cement concrete 1:8:16 with Stone ballast 40mm gauge using concrere mixer volumatric type (C.S.R. Item No. 10.6 (b) ii
Cement Concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type. (C.S.R. Item No. 10.12 (ii)
Reinforced cement concrete M-15 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure. (C.S.R. Item No. 10.20)
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth (C.S.R. Item No. 11.5)
115 mm thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth. (C.S.R. Item No. 11.35)
12.5 mm thick cement plaster 1:4 walls outside (GL and Top) (C.S.R. Item No. 15.9)
White washing (Three coat) (C.S.R. Item No. 16.3)
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two coats to give an even shade. (C.S.R. Item No. 16.14)
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. (C.S.R. Item No. 16.17)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surfaceto give an even shade. (C.S.R. Item No. 16.18)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. (C.S.R. Item No.16.21 b)
Painting two coats including priming coat with ready mixed paint for metallic surface in all shades on new steel or iron work. (C.S.R. Item No. 16.22 b)
Hollock wood, doors, shutter, windows, shutter including hinges, screws, chocks, cheats, stops, cords etc. complete fixed in position. (ii) 35 mm thick (C.S.R. Item No. 17.10 iii)
Steel work fixed independently without connecting plates including hoisting & fixing in position oa angle & channel. (C.S.R. Item No. 18.1)
Providing, Laying, fixing & jointing of P.V.C Pipes as per ISI-4985 (ISI Marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradlents, cutting, jointing and testing complete as per specifications .Including specials and excavation minimum cover 1 mtr (6kg/cm2 pressure) (xvii) 63 mm o/d (C.S.R. Item No.28.13 b)+ 28.18 + 28.2
(xviii) 90 mm o/d
(xx) 160 mm o/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410 ) and Bronze ( gunmeted) working parts Sluice Valves ISI marked 14846-2000, including, jointing, testing & cost of Nut, Bolt & insertion sheet all carriage complete ( with the approval of Engineer-in-Charge). a) 80mm i/d Sluice Valves (C.S.R. Item No. 28.27 A)
(b) 100mm i/d Sluice Valves
(c) 150mm i/d Sluice Valves
Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method . Including excavation, stringing and jointing of pipe upto 160mm complete. (C.S.R. Item No. 28.71)
Supplying, fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSRs complete in all respects. (C.S.R. Item No. 28.90)
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box and Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:- (i) b) Wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size) (C.S.R. Item No. 33.03)
(ii) Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
(iv) Wiring 3 pin 6 Amp. wall socket point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade complete with bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade.
(vi) Wiring 3 pin 16/20 amp. power plug control and switch.
Non Schedule Items Providing & Fixing Orient Electric Apex-FX 1200mm Ceiling Fan (White) & Regulator etc. complete. (N.S. Rates)
Providing & Fixing Crompton Slim Ray 18-Watt LED Tube Light (Cool Day Light) complete. (N.S. Rates)
Providing & Fixing Syska SSK-SRL 15W B22 LED Bulb (Cool Day Light) complete. (N.S. Rates)
Supplying and fixing 150 mm i/d Galvanized iron sheet floating arm 5.20 mtr long and guides complete in all respects as per Public Health standard including sluice valve, survivel bend, floating drum, extended rod with hand wheel brackets. (N.S. Rates)
Repair and leakage of pipe line (water works to village). (N.S. Rates)
Labour for making 3 No. holes & 1 No. cut in case of angle iron pickets. (N.S. Rates)
Providing & fixing barbed wire fencing 3 ply rating with angle iron pickets with M.S. clips including labour for stretching of barbed wire & cost of clips. (N.S. Rates)
Dismantling brick of flanged stone flooring without concrete base and recondition (N.S. Rates)
Providing, installing, testing & Commissioning one no. Electronically acturated, Diaphragm operated, Metering system, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6.0 Litres of Bleaching powder solution/ Sodium Hypo Solution per Hour under maximum delivery pressure up to 7 kg./ sqcm and suction lift not less than 1.5m as per DWSS standard specifications. (N.S. Rates)
Providing house hold connection including laying, jointing, fixing testing below ground level MDPE pipe and above of ground level GI pipes (as approved by Engineer-In-Charge), including cost of excavation, Refilling, CI bib cock as per IS:210 with stainless steel spindle, 15mm i/d GI pipe 2.50 Mtr. & 15mm i/d MDPE pipe 2.00 Mtr. (length on average basis) 3" uPVC clamp, ISI marked G.M. Ferrule as per IS:2692 connection of 15mm i/d ferrule midium, specials such as tees, bends, sockets, elbow, nipples (100 mm & 150mm) Union Copplings, GI hooks etc., cutting, threading, making hole in wall and testing in treanches in the ground all material should be of approved make (to the approval of Engineer-in-charge) complete in all respect including cost of carriage. (Ref. CSR item Nos. 28.1, 28.36, 28.34 B, 30.65 b. Water Connection on Old pipe line (N.S. Rates)
Water Connection on New pipe line (N.S. Rates)
Painting of Sign Board. (N.S. Rates)
Credit of old material for floating arm. (N.S. Rates) (-)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .