| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.8 L+₹3.3 L (21.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.7 L+₹4.2 L (26.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹19.8 L+₹4.3 L (27.9%)Rejected-Finance 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹19.9 L+₹4.4 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Jul 2022, 6:00 pmClosed
GE (AF) E/M Chakeri
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR/ MAINT OF AIR CONDITIONER OF TECH AREA AT AF STATION CHAKERI, KANPUR
2022_MES_530629_1
8577/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹50,000
Yes
1 Aug 2022
13 Jun 2022
14 Jul 2022
13 Jun 2022
12 Jul 2022
29 Jun 2022
Amount
M&L for servicing of window air conditioner 1 / 1.5 / 2 TR at various locations complete by cleaning/ filter/ condenser/ evaporator section with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functioning of spares of air conditioners and replacing the defective parts and supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all as specified and directed. Notes- (i) Spares shall be measured and paid saperately under relevent item of BOQ. (ii) As the nature of work is of daily maintanace of air conditioners, contractor should deploy adequate trained technicians with helpers as intimated by Engineer-in- charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 1500 per complaint per Day till the rectification shall be charged from the contractor. (iii) Contractor should make own arrangement for transportation of Air conditioners from site to workshop and workshop to site.
M&L for servicing of indoor and outdoor units of split type AC of capacity 1.5 / 2 TR at various locations by cleaning of filters, indoor cooling coil, condenser coil with sparying water and brushing, removing of dust, dirt from air condtioners all over check all electric connections, checking any leakage by applying soap solution on joints and liquid / vapour lines properly. Cheking of functioning of spares of air conditioners and replacing the defective parts and supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all as specified and directed.
All as per item No. 2.00 above but tower AC of capacity 3.5 TR.
Supply only Running capacitor 4 MFD complete all as specified and directed. Make: ASIAN/ELLYT/EPCOS.
Supply only Running capacitor 45 MFD complete all as specified and directed. Make: ASIAN/ELLYT/EPCOS.
Supply only Running capacitor 50 MFD complete all as specified and directed. Make: ASIAN/ELLYT/EPCOS.
S&F in replacement Running capacitor 2.5 MFD, 240 Volt complete all as specified and directed. Make: ASIAN/ELLYT/EPCOS.
Supply only starting relay 1.5/2.0 TR/3.5 TR complete all as specified and directed. Make: Asian/Epcos/Renutrol.
Supply only thermostate switch with knob suitable for window AC complete all as specified and directed.
Supply only contactor relay for tower AC of capacity 3.5 TR AC, 415V, 50Hz, 3 Phase complete all as specified and directed.
M&L for disconnecting of unserviceable PCB from the unit of split AC / window AC transporting to Market for repair / replacement of defective part required to make servicable & reinstalling with the unit and making connections complete all as specified and directed.
S&F in replacement of MCB SP, 240 Volt, 32 Amp 10 KA capacity complete all as specified and directed. Make: Legrand / Schneider / ABB
S&F in replacement metal clad socket industrial 2pin & earth plug of 20A, 230V suitable for AC Box complete all as specified and directed. Make: Legrand / Schneider / ABB
S&F in replacement metal plug top industrial 2pin & earth plug of 20A, 230V suitable for AC Box complete all as specified and directed. Make: Legrand / Schneider / ABB
Supply only (NRV) suitable for window/split AC of 1.5/2 TR complete all as specified and directed.
S&F in replacement Flare nut 5/8' complete all as specified and directed.
S&F in replacement Flare nut 3/8' complete all as specified and directed.
S&F in replacement Flare nut 1/2' complete all as specified and directed.
S&F in replacement Flare nut 1/4' complete all as specified and directed.
S&F in replacement Dead nut 5/8' complete all as specified and directed.
S&F in replacement Dead nut 3/8' complete all as specified and directed.
S&F in replacement Dead nut 1/2' complete all as specified and directed.
S&F in replacement Dead nut 1/4'. complete all as specified and directed.
Supply only OLP relay suitable for 1.5 TR/2.00 TR AC complete all as specified and directed. Make: ASIAN/EPCOS/RENUTROL.
Supply only copper liquid line filter 2/3/4 way suitable for copper pipe of 3/8" dia for window / split AC complete all as specified and directed.
S&F in replacement copper pipe 1/4" outer dia complete all as specified and directed.
S&F in replacement copper pipe 5/8" outer dia complete all as specified and directed.
S&F in replacement copper pipe 3/8" outer dia complete all as specified and directed.
S&F in replacement only copper pipe 1/2" outer dia complete all as specified and directed.
M&L for dismantaling, disconnecting unserviceable compressors from Split/window AC of capacity 1.5 TR and replacement with new HSCM compressor (rotary type) on mountings such as rubber pads, nut, bolt, wahers and breezing suction and discharge lines properly, making electrical connections, checking leakage at joints and vaccuming the system complete all as specified and directed.
All as per item no. 30 above but Reciprocating compressor for 1.5 TR AC 220 V.
All as per item no. 30 above but Reciprocative compressor for 2.0 TR AC 220 V.
All as per item no. 30 above but Rotary Compressor for 2.0 TR AC, 220V, Single Phase.
All as per item no. 30 above but Scroll compressor of capacity 3.5 TR AC, 415V, 50Hz , Three phase.
M&L transportaion of air conditioner from site to work shop for detecting leakage from the close circuit of window air conditioner 1 / 1.5 / 2.0 TR capacity, rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakage, charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site complete all as specified and directed. (Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates).
M&L for dismantling of indoor unit split Air conditioner of capacity 1.5 / 2 TR transporting from site to workshop for detecting leakage from the close circuit of split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakage, charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site complete all as specified and directed. (Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates).
M&L for dismantling of outdoor unit split Air conditioner of capacity 1.5 / 2.0 TR transporting from site to workshop for detecting leakage from the close circuit of Tower air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakage, charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site complete all as specified and directed.
M&L for detecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakage charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site complete all as specified and directed. Note for Sr Item No. 35 to 38: (Detecting leakage at one point shall be measured as one and vice versa)
M&L for charging of refrigerent R-22 in window / split AC of capacity 1 / 1.5 / 2.0 / 3.5 TR capacity after detection and rectification of leakage under relevant item No. 35,36, 37 & 38 of schedule and testing complete all as specified and directed.
All as per Item No. 39 above but charging of refrigerent R-410.
All as per Item No. 39 above but charging of refrigerent R-32.
Supply only refrigerent R-22 gas suitable for split/ window type air conditioner in empty cylinder at AGE E/M-III storeyard complete all as specified and directed. Note: (i) Empty cylinder will be provided by the department for filling up refrigerent. (ii) Refrigerent purchase voucher should be provided by the contractor. (iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed.
All as per Item No. 42 above but R-32.
All as per Item No. 42 above but R-410.
M&L for disconnecting and dismentaling of blower / condenser motor of window air conditioner of capacity 1.5 TR transporting for civil workshop and rewinding with super enamelled copper conducter wires of superior quality and assembling with the AC unit and testing and commisioning complete all as specitfied directed .
All as per Item No. 45.00 above but motor of out door unit of split type air conditioner of capacity 1.5/2.0 TR.
All as per Item No. 45 above but motor of Tower AC 3.5 TR capacity.
S&F in replacement of single phase electric motor AC/DC of indoor unit capacity 1.5 / 2.0 TR split AC as per existing make and sample as per site requirement complete all as specified and directed.
M&L for disconnecting leak almunium condenser coil from split air conditioner of capacity 1.5/2.0 TR and S&F copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed.
S&F in replacement sheet metal enclosure, 32 Amp single pole and nutral with a two pin and earth plug socket complete metal clad board (industrial type) with MCB 32 Amp fix properly complete all as specified and directed. Make: Legrand / Schneider / ABB
M&L for factory made MS angle iron stand of suitable size to mount outdoor unit of capacity 1.5 / 2.0 TR split AC complete all as specified and directed.
Supply only Copper rod for brezzing complete all as specified & directed.
S&F Nylon stranded PVC flexible pipe Drain pipe of size 15 mm as per sample complete all as specified & directed.
S&F in replacement PVC insulated & sheathed round multi stranded copper conductor 1.5 sq mm 3 core 1100 Volts graded complete all as specified & directed. Make: Plaza / Havells / Finolex
S&F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded complete all as specified and directed. Make: Plaza / Havells / Finolex.
S&F in replacement blower fan blade for window AC of 1.5 / 2.0 TR capacity as per existing make and sample complete all as specified & directed.
Supply only Butane gas cartridge container not less then 230 grms or standard available in market for complete all as specified and directed.
M&L shifting of split AC 1.5 TR / 2.0 TR 3.5 TR with indoor unit, outdoor Unit, stabilizer to a new possition as per requirement, re-fixing and testing up to the satisfaction of Engr-In-charge, mounting of split Air conditioner outdoor unit on wall mounting stand for suitable size of 1.5 / 2.0 TR split AC complete all as specified and directed. Note: Unit rate of this item included the cost of making necessary holes, drilling, screw etc and all electric and gas tube connection.
S&F in replacement fan blade of condenser of outdoor unit of split type air conditioner 1.5 / 2.0 TR capacity as per make & sample complete all as specified and directed.
M&L for disconnecting of burnt PCB from the unit and S&F new PCB of window AC of capacity of 1.5 / 2.0 TR of any make/model including testing and commissioning complete all as specified & directed.
All as per item no 60 above but PCB of split AC 1.5/2.0 TR capacity.
S&F in replacement of condenser fan motor including mounting base, rubber, clips, as per existing make and soft length in split type AC of 1.5 / 2.0 TR capacity complete all as specified and directed.
S&F in replacement of condensor fan motor including mounting base, rubber, clips, as per existing make and soft length in window type AC of 1.5 / 2.0 TR capacity complete all as specified and directed.
M&L for rewiding of burnt transformer of voltage stablizer of capacity 4 KVA with super enameled copper conducter winding wire and assembling with the stablizer complete all as specified and directed.
All as per item No 64.00 above but capacity 5 KVA.
S&F in replacement of relay 25/30 AMPS 24 volt make and capacity of 4 KVA voltage stabilizer complete all as specified & directed.
All as per item No 66.00 above but capacity 5 KVA.
S&F in replacement of main PCB with high and low voltage cut off PCB suitable for 4 KVA voltage stabilizer suitable making for existing complete all as specified & directed.
All as per item No 68.00 above but suitable for 5 KVA.
M&L for writing SM/MES No on window/ split/ Tower AC in block of sizes 6 sqmm X 10 sqmm complete in indoor/ outdoor unit of split AC by black enamel paint by brush through painter complete all as specified and directed.
kushwaha brothers
PAWAN COOL CORPORATION
Z N Enterprises
Ajanta Associates
Uma engineers
HVAC Engineering Co
m/s A.A brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .