Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
18 Sept 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHIKHA SINGH
NR-1, POWERGRID CORPORATION OF INDIA LIMITED, RHQ FARIDABAD, HARYANA
Construction of Recreation centre at Bhinmal Sub-station
5002001845/OTHERS/DOM/I00 - NR1 RHQ -1
Open
Civil Works - Buildings
Fixed-rate
400/220 KV Substation, Bhinaml, (Dist.- Jalore) Rajasthan.
₹5,000
18 Aug 2021
18 Aug 2021
20 Sept 2021
18 Aug 2021
18 Sept 2021
18 Aug 2021
7 Sept 2021
Name of Package : Construction of Recreation Centre at Bhinmal Sub-station
Specification No. : N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021
Completion Period 12 Months
: Attachments : General guidelines for filling up the Attachments Construction of Residential Complex: - :
Construction of Recreation Centre at Bhinmal Sub-station
Specification No.: N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(r) and as per remarks in the Attach 18.
8 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder
9 Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
10 Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
11 Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of Recreation Centre at Bhinmal Sub-station
N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Sole Bidder 1
Yes JV (Joint Venture) 2 or More
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 2 0
Address of Bidder
Whether the bidder is an MSE (Micro & Small Enterprise) Yes Yes 2 2 0
Enter the Name of Registration Authority
Whether the bidder meets Minimum Local Content in line with PPP-MII order, 2017 0 2 2 0
e-mail ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory MSE Yes
Name of other Partner Ram Lal
Address of other Partner G5
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-3(JV) Sole Bidder
Construction of Recreation Centre at Bhinmal Sub-station
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address To:
Contract & Materials & Ram Lal
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith Sole Bidder
Date : -- Printed Name : 0
Place : Designation : 12
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-3(QR)
Construction of Recreation Centre at Bhinmal Sub-station
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract & Materials
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 Northern Region –I, Regional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Faridabad-121002
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) #REF! 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm 0
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Date of Commercial production
9 Nationality of
10 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
11 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
1.1 1.0 Technical Experience: The Bidder shall have successfully executed similar works (i.e. building works in RCC framed structure including services) for Govt. or Semi Govt. or reputed private sector Organization within the last seven years from the originally scheduled date of bid opening, as per following: One single work/project of a value of not less than INR 141.41 Lakhs including GST OR Two works/projects, each of a value of not less than INR 88.38 Lakhs/- including GST OR Three works/projects, each of a value of not less than INR 70.71 Lakhs including GST
1.2 Route-2: The bidder(s) who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the Collaborator(s) for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Collaborator(s) provided that:- (a) Collaborator(s) meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Collaborator(s) (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
1.3 Route-3: In case, the bidder is an Indian Entity established as Subsidiary/JVC/Group company by its parent/principal, who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the parent/principal for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Parent/ Principal company provided that:- (a) Parent/ Principal company meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Parent/ Principal company (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Parent/ Principal company along with the bid stating that Parent/ Principal company shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
In case bidder is a holding company, the technical experience referred to in para 1.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in para 1.1 above shall be of that subsidiary company only (i.e. excluding its holding company).
Using the following formats, each Bidder is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format-A: (ROUTE-1)
Format for the Bidder/ Collaborator/ Parent/Principal Company of the bidder who must have designed, manufactured, tested & supplied 715kV or Higher Voltage class Reactor in support of meeting the Technical experience requirement of 1.1 of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
Single Firm : 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of Reactors supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 110 MVAR OR no. of Reactors in Banks of 3 single phase units of at least 36.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
(a)(ii) No. of years, the above Reactor(s) are in operation as on the date of bid opening.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(i) Voltage Level of Transformers supplied under the Contract (Indicate 715kV or above class only)
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 500 MVA OR no. of Transformer in Banks of 3 single phase units of at least 166 MVA each)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Transformer
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Transformers of Transformers
of Transformers of Transformers
Details of documents uploaded in support of the above stated experience
4(b)(ii) Voltage Level of Reactors supplied under the Contract (Indicate 345kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 3 phase Reactors with rating not less than 50 MVAR OR no. of Reactor(s) in Banks of 3 single phase units of at least 16.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(iii) No. of years, the above transformer(s) and reactor(s) indicated at 4(b)(i) & 4(b)(ii) respctively, are in operation as on the date of bid opening.
Details of documents uploaded in support of the above stated experience
Format-B: (ROUTE-2)
Format for Bidder(s) [who have established production line and testing facilities in India for 715kV or above class Reactor based on Technology Support of Collaborator(s)], in support of meeting the requirement of 1.2 (Route-2), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents
Name of the Reactor Manufacturer 0 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Reactors manufactured under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
whether the above Reactors are in operation as on the date of bid opening.(Yes/No)
No. of years, the above Reactors are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-C: (ROUTE-3)
Format for Bidder (Indian entity) established as Subsidiary/ JVC/ Group Company by its Parent/ Principal, who have established production line and testing facilities in India for 715kV or above class Reactor, in support of meeting the requirement of 1.3 (Route-3), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Bidder 0
Name of the Parent Company/Collaborator/Subsidiary for the 765kV Reactor {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above) 0
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Voltage Level of Reactor supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactor with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Date as on which the above mentioned Reactors are supplied based on technological support of parent company / collaborator(s) / subsidiary.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by bidder
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
Name of the substation or switchyard
(b)(ii) Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
5 Whether Parent/Principal company(s) meets the technical experience criteria stipulated at 2.1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
6 Whether legally enforceable undertaking jointly by Bidder and the Parent/Pricipal company(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
7 Confirmation letter from the Parent/Principal Company along with the bid stating that Parent/Principal Company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder wish/proposes to qualify through Route-3 of Annexure-A(BDS))
8 Details of documents uploaded in support of the above stated experience Annex-XXX Annex-YYY Annex-ZZZ
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
Minimum Average Annual Turnover @ (MAAT) for best 3 financial years out of last 5 financial years of the bidder shall not be less than INR 265.14 Lakhs . Note: For MSME registered firm, relaxation of 20% on financial aspects i.e MAAT requirement will be considered
b Minimum Average Annual Turnover^ (MAAT) for best three (3) years i.e. 36 months out of last five (5) financial years of the bidder should be Rs. 1233.18 million or equivalent for Reactor Package RT-08 ^ Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income.
c Bidder shall have liquid assets (L.A.) or/and evidence of access to or availability of credit facilities of not less than Rs. 205.53 million or equivalent for Reactor Package RT-08
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) but no later than seven (7) years from the date of incorporation of the said company as on the originally scheduled date of bid opening as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he meets the turnover requirement on their own or completes five (5) years from the date of commercial production of such equipment(s) in India but no later than seven (7) years from the date of incorporation as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered.
(iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 2 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2 (b) & 2 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
Note: For MSME registered firm, relaxation of 20% on financial aspects i.e MAAT requirement will be considered
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data for Bidder: 2 or more
Name of the Bidder
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
A Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
5.0 Financial Qualification Data for Parent/Principal Company/Collabrator (If Applicable): 0
Name of Parent/Principal Company/Collabrator
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
B Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
6 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
6.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
6.2 Technical Credentials: List of work regarding past experience indicating the execution of similar work successfully, schedule time of completion and actual time of completion, the present status of projects in hand along with presently envisaged completion dates, qualification and experience of key personnel proposed for carrying out the subject work. List of available T & P and Manpower available with the bidder is also to be enclosed. Litigation History: The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder may result in rejection of Bid.
6.3 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-3(QR)
Construction of Recreation Centre at Bhinmal Sub-station
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract Services
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) 0 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
9 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
10 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1.1 The bidder must have designed, manufactured, tested, supplied, installed and commissioned 345kV or above class 3-phase transformers of at least 200 MVA or at least three (3) nos. 1-phase Transformers each having capacity of at least 66.7 MVA and the same Transformer(s) must have been in satisfactory operation* for atleast two (2) years on the originally scheduled date of bid opening i.e. 19.02.2019.
*Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
2.1.2 The 345 kV or above class transformer manufacturer(s) who have established production line in India for these equipment(s) based on technological support of a parent company or collaborator for the respective equipment(s) can also be considered provided i) such manufacturer has designed, manufactured, tested, supplied, installed and commissioned 220KV or above class transformers. ii) the parent company (Principals) or collaborator meets qualifying requirements stipulated at para 2.1.1 above; and iii) The 345 kV or above class transformer manufacturer(s) furnishes a) a legally enforceable undertaking (jointly with the parent company or collaborator) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); and b) a confirmation letter from the parent company or collaborator alongwith the bid stating that parent company or collaborator shall furnish performance guarantee for an amount of 10 % of the cost of such equipment (s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the Bidder. Note-1: In case bidder is a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company).
2.1.3 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder OR Parent Company / Collaborator(s)/ Subsidiary (meeting para 1.1.1, Annexure-A to BDS) in support of meeting the requirement of para 1.1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
1 Name of Contract Undertaken (for 345kV or above class Transformers) 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Transformer erected under the Contract (Indicate 345kV or above class only)
5 No. of Transformer (s) under the contract (Indicate nos. of 345kV or above voltage class Transformer not less than 200MVA or equivalent capacity in banks of 3 single phase units each having capacity of at least 66.7 MVA, during the last Two (2) years)
6 MVA capacity of above mentioned 3-phase/1-phase units
7 Name of the substation or switchyard
8 No. of years, the above Transformer are in operation as on the date of bid opening. (Originally Scheduled)
9 Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
10 Details of documents uploaded in support of the above stated experience
Format for the Bidder in support of meeting the requirement of para 1.1.2, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
a Name of the Bidder
b Whether Bidder/Manufaturer established production line in India for 345kV or above class transformer
c Name of the Parent Company/Collaborator for the 345kV Transformer {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above)
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Indicate details below in case Contract executed for Transformer
(i) Voltage Level of Transformer erected under the Contract (Indicate 220kV or above class only)
(ii) No. of Transformer (s) under the contract (Indicate nos. of 220kV or above voltage class Transformer only)
(iii) Name of the substation or switchyard
(iv) No. of years, the above Transformer are in operation as on the date of bid opening.
(v) Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
5 Whether parent company / collaborator(s) meets the technical experience criteria stipulated at 2.1.1 , and the details of which is mentioned at Format-A above. (Choose whichever is applicable from the drop down menu) Yes
6 Whether legally enforceable undertaking jointly by Bidder and the parent company / collaborator(s) (as per enclosed format in Section-VI: Sample forms and Procedures of the bidding documents) is furnished along with the bid. (Choose whichever is applicable from the drop down menu)
7 Confirmation letter from the Parent Company / Collaborator along with the bid stating that Parent Company / Collaborator shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s). (Choose whichever is applicable from the drop down menu)
8 Details of documents uploaded in support of the above stated experience
3.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive b) Minimum Average Annual Turnover* (MAAT) for best three years i.e. 36 months out of last five financial years of the bidder should be INR 1075.90 million. * Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income”. c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than INR 179.32 million. Note 1:- In case bidder is a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of subsidiary company only (i.e. excluding its holding company).
Note 2:- Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 3.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 3.0 (b) & 3.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data: 2 or more
Name of the Bidder 0
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Average Annual Turnover for best Three Years is
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively requirements stipulated at clauses 3.0 (b) & 3.0 (c) above. The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 3.0 (b) & (c) above.
However, for a JV to be qualified, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 3.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum criteria given at clause 3.0 (b) & (c) and 100 % of the criteria given above at clause 2.1 iii. The other partner(s) shall meet not less than 25% of the criteria given at clause 3.0 (b) & (c) above and 100 % of the criteria given above at clause 2.1 or 2.2 Failure to comply with this requirement will result in rejection of the joint venture’s bid.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-3(QR)
Construction of Recreation Centre at Bhinmal Sub-station
(Qualifying Requirement Data)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-4
Construction of Recreation Centre at Bhinmal Sub-station
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-4(A)
Construction of Recreation Centre at Bhinmal Sub-station
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-4(B)
Construction of Recreation Centre at Bhinmal Sub-station
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-5
Construction of Recreation Centre at Bhinmal Sub-station
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-5A
Construction of Recreation Centre at Bhinmal Sub-station
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-6
Construction of Recreation Centre at Bhinmal Sub-station
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-7
Construction of Recreation Centre at Bhinmal Sub-station
(Details of Alternative Bid)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-9
Construction of Recreation Centre at Bhinmal Sub-station
(Work Completion Schedule)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and completion of works i.e., Construction of Recreation Centre at Bhinmal Sub-station for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work- Activity Construction of Recreation centre at Binmal Sub-station
Breakup of Completion Schedule in Months (Bidder must fill break-up Schedule)
1 Handing over of site to agency/ Mobilization at site
a Establishment of site office
b Kick off meeting
2 Completing statuory requirement of contract such as labour license, Insurance policies- Workmen Compensation Insurance Policy, Contractor All Risk Insurance Policy, etc
3 Sampling and source approval of construction materials including design mix for RCC concrete or as per BPS
4 Excavation of basement
5 RCC structure work below Plinth level
6 RCC structure work above Plinth level
7 All ancillary Civil works including Brick Work, Plaster, Painting, Doors, Windows, Flooring, Water Proofing, Building. Septic tank/ Soak pit, etc
8 Internal & External electrification
10 Fire Fighting work
11 Plumbing & Sewerage work
12 Road, drain, water harvesting, swimming pool work, etc
13 Development of Horticulture work
14 Balance- Internal, external finishing as per requirement of site
15 Handing/ taking over of facilities including submission of "As BUILT DRAWING" and relevant NOCs (if required)
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-10
Construction of Recreation Centre at Bhinmal Sub-station
(Guarantee Declaration)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Dear Sir, We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. We further declare that in the event of any deficiencies in meeting the guarantees in respect of the characteristics mentioned below as established after conducting the factory test, you may at your discretion, reject or accept the equipment after assessing the liquidated damages as specified in the relevant clauses of Bid document. We note that in case we take any deviation regarding the maximum losses, as mentioned above, anywhere in the bid including Attachment-6 (Alternative, Deviations and Exceptions to Provisions), our bid shall be considered non –responsive in line with ITB clause 24.1(b) as modified in Section BDS.
Date -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-11
Construction of Recreation Centre at Bhinmal Sub-station
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-11
Construction of Recreation Centre at Bhinmal Sub-station
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Ram Lal Power Grid Corporation of India Ltd.,
Address : G5 Northern Region-I, Reagional Headquarter
Gurgaon SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-11
Construction of Recreation Centre at Bhinmal Sub-station
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region-I, Reagional Headquarter
SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 ATTACHMENT-12
Construction of Recreation Centre at Bhinmal Sub-station
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We hereby furnish the relevant details pertaining to the price adjustment provisions for your specifications and documents . The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
PV Price Component
I. Supply and Placement of Reinforcement Steel:
i) A- WPI-HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Baic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) A- WPI-HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Cement,Lime and Plaster 0.3 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in
C-WPI-Cutting ,Shaping and finishing Stone 0.2 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.1 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Prices are firm & Fixed
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-13
Construction of Recreation Centre at Bhinmal Sub-station
(Declaration regarding Social Accountability)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-14
Construction of Recreation Centre at Bhinmal Sub-station
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai,New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of Recreation Centre at Bhinmal Sub-station
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Construction of Recreation Centre at Bhinmal Sub-station Package and Specification Number N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-15
Construction of Recreation Centre at Bhinmal Sub-station
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. Yes
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-16
Construction of Recreation Centre at Bhinmal Sub-station
(Additional Information)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder) 0
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
5.0 Details of Provident Fund Code Number of the Bidder [ref. ITB9.3(q)]
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-17
Construction of Recreation Centre at Bhinmal Sub-station
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-17
Construction of Recreation Centre at Bhinmal Sub-station
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. B9, Qutab Institutional Area, Katwaria Sarai
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-17
Construction of Recreation Centre at Bhinmal Sub-station
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : B9, Qutab Institutional Area, Katwaria Sarai
New Delhi-110016
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-18
Construction of Recreation Centre at Bhinmal Sub-station
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Safety Pact is attached herewith this Volume
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Between #REF! #REF!
Power Grid Corporation of India Limited #REF! #REF!
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as #REF! #REF!
"POWERGRID", #REF! #REF!
0 1 having its Registered Office at ,
having its Registered Office at ,, 1 AND
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of Recreation Centre at Bhinmal Sub-station Specification Number:N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 1 of 6
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
1. POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2. POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3. POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4. POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
5. POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6. POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7. POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8. POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9. POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 2 of 6
10. POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1. The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by thembyproviding safe methods of work, working conditions and Tools & Plants for human safety.
2. The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3. The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4. The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5. The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of theirSub-contractors for safety awareness during construction works being executed by them.
6. The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7. The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8. The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 3 of 6
9. The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10. The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at heightand also medically fitfor work at height are deployed for work at height in the Projects executed by them.
11. The Bidder / Contractor shall ensure daily before starting the work thattheir site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12. The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13. The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14. The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / supportshall be provided to the victims / injured till they are completely fit to return to work.
15. The Bidder / Contractorshall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16. The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17. The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 4 of 6
18. The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19. The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20. The Bidder / Contractor accepts the provisions regarding safety, including payment of compensation to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1. POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2. POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1. This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2. Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
3. If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4. Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5. Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 5 of 6
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Safety Pact Page 6 of 6
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Attachment-19
Construction of Recreation Centre at Bhinmal Sub-station
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :N1/C&M/21-22/OTHERS/OT/100 dtd. 18.08.2021 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract & Materials 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Northern Region-I, Reagional Headquarter 11 eleven 11 th 11 November
SCO Bay No. 5 to 10, Sector- 16 A 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of Recreation Centre at Bhinmal Sub-station 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 21 of ITB, Section-II." Please note that if bid validity is less than 06 (six) months, your bid may be rejected
(b) Attachment 2() : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
*Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format.
* Delete if not applicable
(c) Attachment 3() : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4() : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5() : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A() : Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises. 26 th
(g) Attachment 6() : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7() : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8() : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9() : Work Completion Schedule. 30 th
(k) Attachment 10() : Guarantee Declaration. 31 st
(l) Attachment 11() : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12() : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13() : Declaration regarding Social Accountability.
(o) Attachment 14() : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15() : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16() : Additional Information.
(r) Attachment 17() : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18() : Safety Pact
(t) Attachment 19() : Declaration.
(u) Attachment 20() : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21() : Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order December 2018, if applicable
(w) Attachment 22() : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, and MoP Order December 2018, if applicable
(x) Attachment 23() : Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(d) GCC 55 Terms of Payment
(e) GCC 8.3 Performance Security
(f) GCC 6 Taxes and Duties
(g) GCC 38 Liquidated Damages for Delay by Contractor
(h) GCC 40 Defect Liability
(i) GCC 39 Guarantee
(j) GCC 20.5 Patent & Royalties
(k) GCC 61 Limitation of Liability
(l) GCC 57 Settlement of Disputes
(m) GCC 59 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of 0
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
DETAILED CIVIL PORTION ESTIMATE OF RECREATION CENTER AND OPEN GYM AT BHINMAL SUB-STATION
(SCHEDULE OF RATES AND PRICES)- Civil & Other Works
S. No. DSR 2019 Item ref. Description Unit Total Qty.
1 1.1.1 Carriage of materials by mechanical transport including loading, unloading and stacking Up to 1 Km: Lime, moorum, building rubbish Cum 25
2 1.1.2 Carriage of materials by mechanical transport including loading, unloading and stacking Up to 1 Km: Earth Cum 100
3 1.1.4 Carriage of materials by mechanical transport including loading, unloading and stacking Up to 1 Km.: Excavated rock Cum 100
4 2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil Sqm 400
5 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed: All kinds of soil cum 1400
6 2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil: Ordinary Rock cum 100
7 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. cum 100
8 2.9.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: Ordinary rock Cum 10
9 2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil: Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia metre 65
10 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Cum 100
11 2.26.1 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.: All kinds of soil Cum 350
12 2.26.2 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.:Ordinary or hard rock Cum 5
13 2.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. Cum 10
14 2.31 Clearing jungle including uprooting of rank vegetation, grass, brushwood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared sqm. 100
15 2.32 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots stacking of serviceable material and disposal of unserviceable material. sqm. 175
16 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. lit. 35
17 2.35.2.1 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linearmetre including drilling and plugging holes etc: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration metre 70
18 2.35.3.1 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart including drilling 12mm diameter holes and plugging with cement mortar 1: 2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration sqm. 400
19 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum 200
20 4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns Cum 28
21 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) sqm 65
22 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). sqm 28
23 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification per 50Kg Cement 20
24 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil Sqm 28
25 4.17 Making plinth protection 50 mm thick of 1:3:6 cement concrete over 75mm thick dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand,including necessary excavation levelling & dressing & finishing the top smooth. sqm. 20
26 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Cum 150
27 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum 25
28 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Cum 30
29 5.9.1 Centering & shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases of columns etc. for mass concrete. Sqm 150
30 5.9.3 Centering & shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. Sqm 300
31 5.9.5 Centering & shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 200
32 5.9.6 Centering & shuttering including strutting, propping etc. and removal of form work for:Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 400 20000
33 5.9.16.1 Centering & shuttering including strutting, propping etc. and removal of form work for:Edges of slabs and breaks in floors and walls: Under 20 cm wide metre 60
34 5.9.19 Centering and shuttering including strutting, propping etc and removal of form for: Weather shade, Chajjas, corbels etc, including edges sqm 25
35 5.11.1 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) sqm 50
36 5.18.2 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.: 40 mm thick sqm 100
37 5.22.6/ 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for all levels: Thermo-Mechanically Treated bars of grade Fe-500D or more Kilogram 40000
38 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections metre 700
39 6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) cum 25
40 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 coarse sand) cum 200
41 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure plinth to floor V level: cement mortar 1:4 (1 cement : 4 coarse sand) Sqm 300
42 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. sqm 70
43 6.44 Brick edging 7cm wide 11.4cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1: 4 (1 cement: 4 fine sand). metre 60
44 8.2.2.2 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone of any colour and shade : Area of slab over 0.50 sqm. Sqm 150
45 8.3.2 Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge: Granite work. Metre 20
46 8.4 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. Metre 20
47 8.5 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. Each 10
48 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Sqm 85
49 9.4.3.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 3
50 9.9.1.2 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws: Second class teak wood: 30 mm thick Sqm 25
51 9.21.2 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 17
52 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 9.20 and 9.21. Sqm. 17
53 9.27.2.1.1 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 30 mm thick shutters: with ISI marked M.S. pressed butt hinges bright finished of required size: Second class teak wood Sqm 25
54 9.47.1 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type) metre 20
55 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete : Fixed to openings /wooden frames with rawl plugs screws etc. kg 300
56 9.96.2 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm each 9
57 9.97.3 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10mm Each 8
58 9.97.4 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10mm Each 36
59 9.97.5 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100x10 mm Each 90
60 9.100.1 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :125mm Each 16
61 9.100.2 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :100mm Each 45
62 9.101.2 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper Each 8
63 9.102 Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc complete. Each 20
64 9.103 Providing and fixing bright finished brass 100mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc complete. Each 3
65 9.114.2 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc complete: Double strip (horizontal type) Each 8
66 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. kg 8000
67 10.14.1.1 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb metre 58
68 10.14.3.1 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb metre 95
69 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. Each 20
70 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 675
71 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) Kg 300
72 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. Sqm 7
73 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Sqm 1.5
74 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. Metre 14
75 11.32 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre Sqm 7.5
76 11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. Sqm 25
77 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete: Size of Tile 600x600 mm Sqm 450
78 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete: Size of Tile 600x600 mm Sqm 100
79 11.16.2 Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Medium shade pigment using 50% white cement and 50% ordinary cement Sqm 48
80 11.13.1 Providing and fixing glass strips in joints of terrazo/ cement concrete floors: 40 mm wide and 4 mm thick Metre 85
81 11.18.2 Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :Medium shade pigment using 50% white cement and 50% ordinary cement Sqm 13
82 11.20.2 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand): Medium shade pigment using 50% white cement 50% Grey cement Sqm 11
83 12.21.1 Providing gola 75x75mm in cement concrete 1: 2: 4 (1 cement: 2 coarse sand: 4 stone aggregate 10mm and down gauge), including finishing with cement mortar 1: 3 (1 cement: 3 fine sand) as per standard design: In 75x75mm deep chase metre 300
84 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Each 15
85 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes: 110mm diameter metre 100
86 12.42.2.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion: Single pushfit Coupler: 110mm each 6
87 12.42.3.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion: Single tee with door: 110x110x110mm each 4
88 12.42.4.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion: Single tee without door: 110x110x110mm each 2
89 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion: Bend 87.5°: 110mm bend each 40
90 12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion: Shoe (Plain): 110mm Shoe each 20
91 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1: 4 (1 cement: 4 coarse sand) and making good the wall etc complete: 110mm each 18
92 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams. each 4
93 12.47.1 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.: 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified sqm 350
94 13.1.2 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) Sqm 1000
95 13.2.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) Sqm 900
96 13.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) Sqm 500
97 13.9.1 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement: 12 mm cement plaster sqm 65
98 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). sqm 500
99 13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. Sqm 120
100 13.16.1 6 mm cement plaster of mix: 1:3 (1 cement : 3 fine sand) Sqm 140
101 13.26 Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. sqm 1000
102 13.41.1 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer sqm 250
103 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) sqm 250
104 13.50.1 Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) sqm 73
105 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work sqm 100
106 16.91.1 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge: 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. Sqm 20
107 17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually control device ( handle lever), confirming to IS:7231, with all fittings and fixtures complete,including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid. Nos 2
108 17.4.2 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern Nos 1
109 17.7.3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550x400 mm with a single 15 mm C.P. brass pillar tap. Nos 5
110 17.10.1.2 Providing and fixing stainless steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls: Kitchen sink with drain board: 510 x 1040mm bowl depth 225 mm Nos 1
111 17.22A Providing and fixing CP brass 32mm size bottle trap of approved quality & make and as per the direction of Engineer-in-charge. Nos 6
112 17.28.1.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete: Semi rigid pipe : 32 mm dia each 5
113 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 5
114 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc.,Complete. Each 5
115 17.34.1 Providing and fixing toilet paper holder : C.P. brass Nos 2
116 17.35.1.1 Providing and fixing soil, waste and vent pipes : 100 mm dia: Sand cast iron S&S pipe as per IS: 1729. metre 32
117 17.35.1.2 Providing and fixing soil, waste and vent pipes : 100 mm dia : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 metre 15
118 17.35.2.2 Providing and fixing soil, waste and vent pipes : 75 mm diameter :Centrifugally cast (spun) iron socketed pipe as per IS: 3989 metre 25
119 17.37.1 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. :For 100 mm dia. Pipe Nos 40
120 17.39.1.1 Providing and fixing plain bend of required degree.100 mm dia: Sand cast iron S&S as per IS - 1729 Nos 4
121 17.39.1.2 Providing and fixing plain bend of required degree.: 100 mm dia : Sand cast iron S&S as per IS : 3989 each 3
122 17.39.2.2 Providing and fixing plain bend of required degree. : 75 mm dia : Sand cast iron S&S as per IS - 3989 each 5
123 17.40.1.1 Providing and fixing heel rest sanitary bend: 100 mm dia: Sand cast iron S&S as per IS - 1729 Nos 4
124 17.40.1.2 Providing and fixing heel rest sanitary bend: 100 mm dia : Sand cast iron S&S as per IS - 3989 each 3
125 17.43.2.2 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.: 75x75x75 mm : Sand cast iron S&S as per IS - 3989 each 4
126 17.56.1.1 Providing and fixing terminal guard: 100 mm: Sand cast iron S&S as per IS - 1729 Nos 4
127 17.58.1 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm Nos 5
128 17.58.2 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 75 mm each 45
129 17.59.1 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter :100 mm Nos 4
130 17.59.2 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter :75 mm Nos 4
131 17.60.1.2 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet: Sand Cast iron S & S as per IS: 1729 each 7
132 17.73.1 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88mm, weighting not less than 170 mgs Nos 3
133 18.10.3 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore metre 25
134 18.10.4 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : 32 mm dia nominal bore metre 100
135 18.11.1 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore metre 70
136 18.12.3 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore metre 65
137 18.12.6 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore metre 45
138 18.13.2 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore each 1
139 18.16.1 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore each 1
140 18.16.2 Providing and fixing brass stop cock of approved quality :20 mm nominal bore Nos 2
141 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore each 5
142 18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. Nos 2
143 18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore Nos 1
144 18.29 Supplying pig lead at site of work. quintal 1
145 18.32.1 Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks Nos 10
146 18.33.1 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 each 6
147 18.38.3 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 25 mm diameter pipe metre 92
148 18.40.6 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 50 mm diameter pipe metre 45
149 18.48A/B Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: Circular tank/ Rectangular tank Litre 1000
150 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS Standards and weighing not less thn 690gms: 15 mm nominal bore Nos 1
151 18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15 mm nominal bore Nos 3
152 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore: 15mm nominal bore Nos 18
153 18.65 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height 75 mm with concealed fitting arrangements,weighting not less than 106 gms Nos 3
154 18.11.1 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :15 mm dia nominal bore metre 40
155 18.11.2 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :20 mm dia nominal bore metre 50
156 19.1.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter metre 85
157 19.1.2 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter metre 25
158 19.2.1 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm diameter S.W. pipe metre 80
159 19.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe metre 85
160 19.4.3.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 4
161 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 7
162 19.7.2.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 1
163 19.8.1.1 Extra for depth for manholes : Size 90x80 cm: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 metre 2
164 19.8.2.1 Extra for depth for manholes : Size 120x90 cm : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 metre 0.5
165 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. each 22
166 19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 1
167 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 250
168 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 120
169 21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) sqm 19
170 21.4.1 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With stainless steel cover plate minimum 1.25 mm thickness each 6
171 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete : Upto 5mm depth and 5 mm width RM 25
172 21.11.3 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.: 355 X 19 mm each 1700
173 21.13 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. each 22
174 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1: 3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. sqm 11
175 22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm. Sqm 140
176 NSI Providing and fixing CP Health faucet Prayag Cast Brass LCB 2 or eqivalent(make to be approved) with flexible pipe and wall hook with european Water Closet, complete in all respect. Each 4
TOTAL AMOUNT [Including GST]
(SCHEDULE OF RATES AND PRICES)- Electrical & other works
Item No. Item Ref. DSR'18 (Electrical) Description Unit Quantity
1 1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B Point 108.000
2 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Mtr. 250.000
3 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtr. 1150.000
4 1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Mtr. 950.000
5 1.14.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required: 2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire Mtr. 120.000
6 1.14.11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required: 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Mtr. 20.000
7 1.21.2 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: 25mm Mtr. 700.000 S
8 1.21.3 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: 32mm Mtr. 30.000
9 1.22.16 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required: 250 mm X 300 mm X 100 mm deep(Junction Box) EA 2.000
10 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. ( for Light plug point) EA 12.000
11 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(Powergrid plug point ) EA 6.000
12 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required : Single pole EA 25.000
13 2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63A EA 1.000
14 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. ( for AC ) EA 2.000
15 2.4.3 MCB DISTRIBUTION BOARD: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 8 way (4 + 24), Double door EA 2.000
16 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. EA 86.000
17 1.45 Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. EA 4.000
18 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. EA 4.000
19 1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. EA 108.000
20 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required : Upto 450 mm sweep EA 4.000
21 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. EA 3.000
22 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. EA 1.000
23 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. EACH 1.000
24 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Mtr. 10.000
25 5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required Mtr. 40.000
26 9.1.23 Supplying and making INDOOR end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : ( 3.5 C X 70 sq.mm AL (PVC) EA 4.000
27 9.2.20 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : (3.5 C X 70 sq.mm AL (PVC) EA 4.000
28 NSI-1 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED1: Recessed Mounting type LED Fitting (OCTANE SQUARE LED PANEL 24 W 6500 K) for PORCH LIGHTs (24 W - Make: LHEBHEP7IZ1W024 HAVELLS OR Equivalent) EA 8.000
29 NSI-2 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED2: Ceiling Mounting Mirror Optic LED Light Fitting for Toilets (1 X 10W - Make:J002, Jupiter] EA 2.000
30 NSI-3 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED3: Wall Mounting LED Tubelight Fitting for MULTIPURPOSE HALL (1 X 36W - Make: LHEXACP7IN1W036 , Havells or its equivalent ] EA 27.000
31 NSI-4 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED4: Wall Mounting LED Tubelight (LED L.FIXT ELITE PRIDE PLUS 18 W 6500 K) for INDOOR GAMES and LADIES ROOM [1 X 18W - Make: LHEXACP7INW020, Havells or its equivalent EA 10.000
32 NSI-5 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED5: Wall Mounting LED FLOOD LIGHTs ( JETA QUANTO PLUS) for Multipurpose Hall [60W - Make : JETAQUANTOPLUSFLP60WLED757SYMLENS Havells or its equivalent EA 18.000
33 NSI-6 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED-6:Wall Mounting Bulkhead LED lights for Outdoor lighting [ 15 W - Make: J253, Jupiter or its equivalent ] EA 17.000
34 NSI-7 Supplying of prewired LED Light Fixtures along with all accessories complete as required ( Details as per Technical Specification ) LED-7:Wall Mounting Bracket LED lights for Toilets [10 W - Make: J090 , Jupiter or its equivalent] EA 4.000
35 NSI-8 Supplying of 1200mm Sweep Ceiling Fan and its all accessories suitable for operation on '230V single phase, 50 Hz' AC supply complete as required, with Regulator [Make: FHCSSSTWHT48, SS 390 , 1200 mm sweep White, Havells or its Equivalent] EA 4.000
36 NSI-9 Supplying of 230V Exhaust fan of 150mm sweep complete with louver/shutter and it’s all accessories complete as required [Make: VENTO JET 15 AUTO 150 mm Sweep FHVVJAUOWH06, Havells or its equivalent] EA 4.000
37 NSI-10 Supplying , installation, testing and commissioning of Wall bracket fan of 400mm sweep with fan motor, blades etc. with its all accessories cas required [Make: PLATINA HS 400 mm sweep White FHWSWPHWHT16 Havells or its equivalent) EA 14.000
Total Amount Item No.1 to 37 ( Including GST)
38 NSI-11 Metering Panel: Supply and installation , testing and commissioning of the Metering Panel .The Panel shall be made out minimum 2.0 mm thick CRCA sheet steel. The internal frame shall be made of structural steel angles / channels. The panel shall be dust and vermin proof dully painted rvith approved colour of shade. The degree of protection shall not less than IP-52 as per relevant IS code. The sheet steel shroud and partitions shall be of min. 1.6 mm thickness. All sheet steel work forming the exterior of the panel shall be smoothly finished , leveled, having rounded corners and free from any flaws. Shop drg. Of panel should be approved before fabrications. METER PANEL Incomer : 100A TPN MCCB, 20KA RYB Phase Indicator with selector switch Ammeter, Voltmeter with suitable range and arrangement 3 Phase, 1 no. 10-30/40A energy meter Outgoing : 3 Nos. 63A TPN MCCB EA 1.000
39 NSI-12 Supply of aluminium conductor, armoured, PVC insulated PVC sheathed, 1.1 KV grade cable conforming to IS:1554 Part-I of the following sizes ( Data sheet to be got approved ).(Make of cable shall be POWERGRID approved vendor list as availble in the website of POWERGRID) : 3.5 C X 70 sq.mm AL (PVC) Mtr. 600.000
GST @ 18%(Item No. from 38 to 39 )
40 NSI-13 Supply, installation,testing and commissioning of 2 T AC- minimum 3 star rating of reputed make (Voltas/Samsung/Godrej/LG) with all connections, complete piping, drain pipe, stablizer, stand and necessary wiring etc complete in all respect. (except industrial socket) EA 2.000
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01_1st Envelope-attachment.xlsx
xlsx • 1.44 MB
02-Attachment-14-IP.doc
doc • 0.07 MB
03-Attachment-18-SAFETY PACT.docx
docx • 0.03 MB
04_Attachment-20_KMP Declaration.doc
doc • 0.04 MB
05-Attachment-21- Affidavit for Self Certifictaion.docx
docx • 0.02 MB
06-Attachment-22- Certificate by Auditor.docx
docx • 0.02 MB
07-Attachment -23_Declaration regarding events encountered.docx
docx • 0.03 MB
08-Legends.pdf
pdf • 0.03 MB
09_ Bid Securing Declaration Format.docx
docx • 0.02 MB
Thumbs.db
db • 0.02 MB
Drawing.pdf
pdf • 3.54 MB
List of Indicative makes.pdf
pdf • 0.35 MB
TS.pdf
pdf • 0.49 MB
Control Cable (Rev-06).pdf
pdf • 0.18 MB
Lighting System Rev-07.pdf
pdf • 4.29 MB
LT switchgear (Rev -05).pdf
pdf • 0.16 MB
TS ELECTRICAL.pdf
pdf • 0.22 MB
BOQ CIVIL.xlsx
xlsx • 0.03 MB
BOQ ELECTRICAL.xlsx
xlsx • 0.02 MB
Standard Field Quality Plan Civil Works for Site Packages Revision 04.pdf
pdf • 2.22 MB
01-Section - I IFB SSTE Vol-I.docx
docx • 0.04 MB
02 Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.11 MB
03-Section - III_BDS.docx
docx • 0.05 MB
04-Annexure-A (BDS)-QR.doc
doc • 0.05 MB
05-GCC-civil works(Feb 2019).doc
doc • 0.37 MB
06-Section - V_SCC.doc
doc • 0.09 MB
07-Appendix -I to SCC.doc
doc • 0.17 MB
08-Annexure-I to Section-V (SCC).docx
docx • 0.07 MB
09-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.35 MB
4-Annexure-B to BDS.docx
docx • 0.02 MB
Thumbs_1.db
db • 0.02 MB
~$ Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.00 MB
~$-GCC-civil works(Feb 2019).doc
doc • 0.00 MB
~$-Section - I IFB SSTE Vol-I.docx
docx • 0.00 MB
~$-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .