Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 CrAccepted-AOC | ₹17.8 Cr Quoted ₹18.0 Cr | L1 | Accepted-AOC Being L1 and reasonable. |
| 2 | L2₹19.6 CrRejected-Finance | ₹19.6 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹24.5 CrRejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹24.5 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹24.8 CrRejected-Finance | ₹24.8 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹27.7 CrRejected-Finance | ₹27.7 Cr | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹13.3 Cr
EMD Value
₹9.9 L
Closing Date
4 Nov 2021, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243 001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF KLP ACCN FOR FD HOSPITAL EX 9 INF DIV AT MEERUT
2021_MES_476568_1
CEBZ/MRT/T-17 OF 2021-22
Open Tender
Civil Works
365 days
MEERUT
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (S) MEERUT
₹9.9 L
Yes
26 Nov 2021
20 Sept 2021
8 Nov 2021
20 Sept 2021
4 Nov 2021
19 Oct 2021
21 Sept 2021 - 16 Oct 2021
Amount
Sch 'A' PART-I (Building Work) Completion of Incomplete work for Construction of block of single living Accn of officers (1 Maj +3 Capt) including Garrage (3 Cars) complete all as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Servant Qtr (9 +3) (single storey) complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Officer Mess 16 Officers complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of open Garrage with Apron for Offr's Mess (Car 4 Nos) complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of JCO Mess for 16 JCO's (D/S + single living Accn for JCO's scooter shed complete all as specified as shown on drawings and as specified (Group II).
Completion of Incomplete work for Construction of block of Single living Accn for 37 HAV & 107 ORs Dining hall ,kitchen & Cook House storage Accn ration Accn Ration Store drying & ironing shed tradesman shop (Triple Storey) complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of ORs institute + Education building complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Adm & Working Accn (Double Storey) complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Parking space for Adm (4 nos. Car /Scooter & Cycle) complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Guard house and ancillaries (100-350) etc complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Covered Accn for MT Veh : block 1 with apron complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Covered Accn for MT Veh : block 2 with apron complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Covered Accn for MT Veh : block 3 with apron complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Repair bays & inspection pit (one bay with inspection pit) complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of MT storage,& Bty charging shops complete all as specified as shown on drawings (Group II)
Completion of Incomplete work for Construction of block of MI Room X-Ray & pathology FD Hospital complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Parking space (for MI room & field Hospital) 1 truck, 4 Nos Car , 1 Ambulance, 30 Scooter & 20 cycles with apron complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Religious institute Hall (Single storey) complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Parking Shed (for OR's) 50 scooter & 50 cycle with apron complete all as specified as shown on drawings and as specified. (Group II)
Completion of Incomplete work for Construction of block of Fuel Store complete all as specified as shown on drawings and as specified. (Group II)
Construction of Dhobi ghat -3 stone complete all as specified as shown on drawings and as specified.
Construction of Flag Mast complete all as specified as shown on drawings and as specified.
Construction of Washing plate form (3650 x 9820 mm) including ramp complete all as specified as shown on drawings and as specified.
Construction of Double Ramp complete all as specified as shown on drawings and as specified.
Construction of Basket ball court complete all as specified as shown on drawings and as specified.
Construction of Volley ball court complete all as specified as shown on drawings and as specified.
Construction of Badmintan court complete all as specified as shown on drawings and as specified.
Construction of Alarm Post complete all as specified as shown on drawings and as specified.
Construction of Parade Ground complete all as specified as shown on drawings and as specified.
Construction of Foot ball & Hockey ground complete all as specified as shown on drawings and as specified.
Construction of Garbage Bin (Large) complete all as specified as shown on drawings and as specified.
Construction of Coal and coke yard complete all as specified as shown on drawings and as specified.
Completion of Incomplete work for Construction of block of Guard Room etc complete all as specified as shown on drawings and as specified. (Group II)
Construction of Static Water Tank 15 KL Capacity complete all as specified as shown on drawings and as specified.
Construction of Static Water Tank 20 KL Capacity complete all as specified as shown on drawings and as specified.
Construction of Incinerator complete all as specified as shown on drawings and as specified.
Construction of Sentry box ( 1250 x 1250 mm) complete all as specified as shown on drawings and as specified.
Construction of Hard Standing 70 Sqm (40+30) complete all as specified as shown on drawings and as specified.
Note 1 : (Srl No.1 to 38): Above schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only .
Total amount of Sch 'A' Part IIA (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
SCHEDULE 'A' PART-II B (INTER WATER SUPPLY)
S & F Health faucet with 1mm tube and wall stand and including Fixing brackets. etc complete all as specified and directed. Make Hindware F-160059 or equivalent make as specified
S & F, Elbow operated chromium plated fancy Bib tap cast copper alloy with crutch or butter fly handle, screwed down, for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S & F brass CP central hole wash hand basin mixer w/o PUW with 450 mm SS flexible hose sreewed down high pressure screwed for iron pipe etc complete all as specified and directed.
S & F 15 mm dia brass CP sink mixer with swivel spout wall mounted for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed.
S & F15 mm dia brass CP WALL mixer for over head shower with 115 mm long bend pipe & wall flange for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. Make Hindware cat no F-200020/Jaquar cat no CON 273UPR or equivalent make as specified
S & F,brass CP Pillar tap Fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make Hindware cat no F-200001/Jaquar cat no CON 021or equivalent make as specified
S & F brass ,CP Bib tap long body Fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with wall flange complete all as specified and directed. Make Hindware cat no F-200001/Jaquar cat no CON 107 or euivlent make as specified
S & F fancy type brass angle cock Chromium plated , screwed both ends suitable for 15mm bore GI pipe complete all as specified and directed, Make Hindware cat no F-200005/Jaquar cat no CON 053or euivlent make as specified
S & F fancy type brass stop valve Chromium plated , long shunk concealled type with wheel head, screwed both ends suitable for 15mm bore GI pipe complete all as specified and directed,
S & F brass chromium plated shower rose Fancy type , 125mm dia with or without swivel joints, incl shower arm fixing to 15 mm bore pipe or union complete all as specified..
Total amount of Sch 'A' Part III -A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
M & L for Point wiring with 1.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :-
One light point controlled by one way switch 5/6 Amps
One fan point controlled by one way switch 5/6 Amps
One Exhaust Fan point controlled by one way switch 5/6 Amps
One Bell point controlled by one way switch 5/6 Amps
6 Amps 5 Pin Socket on same board controlled by one switch
6 Amps 5 Pin Socket on independent board controlled by one switch
One light point controlled by 2 way switch 5/6 Amps. Note (Srl No 55 to 61):- Switch, Socket out let etc will be paid and measured separately.
M & L for Point wiring with 2.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers and all accessories for one three pin 15/16 Amp socket outlet point on independent board complete all as specified and directed. Note.- Switch & Socket Shall be measured and paid Separately.
S & F batton holder with PVC insulated body angular / straight fixed on plastic laminated sheet cover round shape 3mm thick including 1 No CFL 18 watt 230 volt AC integrated circuit retrofit type suitable for 230 volt AC complete all as specified and directed.
S & F florescent Tubelight 1 x 36 Watt fitting box type complete with all accessories such as electronic choke condenser and florescent Tube rod 36 watt 230 volt fixed on wall / ceiling connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
S & F florescent Tubelight 2 x 36 Watt fitting box type complete with all accessories such as electronic choke condenser and florescent Tube rod 36 watt 230 volt fixed on wall/ceiling connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
S & F Fluorescent TubeLight fitting decorative box with aluminum reflector complete with electronic choke 1 x 36 W HPF and connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector fixed with conduit bell mouth coupler, two Nos down conduits of suitable length and size complete with check nuts and round blocks suitable for 2 x 36 W Tube Light fitting complete with all accessories incl florescent Tube rod complete all as specified and directed.
S & F Ceiling fitting complete with all accessories such as electronic choke and CFL 3 x 36 W , 230V fixed with on ceiling / roof connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified CAT Part No LHCL 01336425
S & F Ceiling fitting 1 x 20 W complete with all accessories such as electronic choke, and CFL of 20W 230V fixed on ceiling connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply & fixing security light fitting suitable for 2 x 11 watt CFL and including 2 Nos CFL lamp of 11 watt complete with M & L GI pipe mounting bracket of size 25 / 32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
S & F mirror light fitting 2 x 18 W complete with all accessories such as electronic choke, and CFL 2 Nos of 18W 230 V fixed on wall connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
M & L for Sub main wiring with four single core, 16 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
M & L for Sub main wiring with four single core, 10 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed / surface conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
M & L for Sub main wiring with two single core, 10 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
M & L for Sub main wiring with two single core, 6 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 2.5 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
M & L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 2.5 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
M & L for Tripple pole and neutral DB’s, 8 way suitable for mounting MCBs/ Isolators as outgoing and incoming MCCB 125 Amp TP complete vertical load line type including all fixing materials / accessories for double door DB, all as specified and directed. Note : Incoming MCCB and outgoing MCB SP/TP will be measured and paid seperately.
M & L for Distribution board single pole and neutral 12 way, 240 volts, double door type suitable for mounting incoming and outgoing MCB’s double pole/single pole, 4/8 Nos respectively out going MCB’s. all as specified and directed Note : Incoming and outgoing MCB SP/TP will be measured and paid seperataely.
All as per Item No 77 but 8 way
All as per Item No 77 but 6 way
All as per Item No 77 but 4 way
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps (for geyser) complete all as specified and directed.
M & L for Miniature circuit breaker single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to 32 Amps current rating ‘D’ series, 10 KA complete all as specified and directed.
S & F,Miniature circuit breaker triple pole and neutral with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for three phase circuit of 415Volts and 63 Amps , 10 KA complete all as specified and directed.
S & F,Miniature circuit breaker single pole and neutral (SPN)with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to32 Amps series, 10 KA complete all as specified.
All as per Item No 84 above but 63 Amps complete all as specified and directed.
S & F MCCB TP 415 Volts 100 Amps Cap, 25 KA fixed on load line vertical DB TPN complete all as specified and directed.
Supply & Fixing , Ceiling fan 1200mm sweep complete with capacitor canopy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified and directed.
S & F, Ceiling fan 1400mm sweep with regulater capacitor canopy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified and directed.
S & F propeller type AC ventilating fans 300 mm sweep (Exhaust fan) with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. Make- Usha/Havells.
All as per item No. 89 above but 450 mm sweeps complete all as specified and directed.
M & L for Numbering of all fans / light fitting / geysers / exhaust fans with enamel paint (as per sample) complete all as specified and directed..
S & F Blanking plate complete all as specified and directed.
S & F, call bell AC 240 V single phase ding dong complete all as specified and directed.
M & L for Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI ‘light grade’ pipe from upper end of earth plate uopto main switch/control of the building including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation, earth work including laying the GI pipe concealed in floor /wall all as described in electrical plate No 3 of SSR Part I.
S & F earth continity conductor or main earthing lead fixed on wall recasse or chases of buried in ground or drawn in conduite/pipe or fixed to pole or any other indicated situation for loop earthing etc. as buried 4mm dia galvanised iron or steel wire complete al;l as specified and directed.
S & F Geysers single phase 230 Volts storage type vertical shape 25 Litrs capacity including necessaryv fittings / fixture complete all as specified and directed.
S & F electric control panel vertical, three phases distribution board with provision for 4 pole MCCB (T-max / T1 type) upto 200 Amps as in comer & 3 phase and single phase (TP/SP) as out going, with insulated bus bar arrangement for 4 way complete all as directed. (MCCB shall be measured and paid separately)
M & L of 25 mm dia rigid PVC conduit including sunk boxes (junction/terminal), all tees, bends,elbow,reducer, bell mouth tube ends and all fixing accessories such as coupler, lock nuts sadles, pipe hook complete all as specified and directed.
M & L for Point wiring, flame proof with 1.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including stove enamelled steel concealed conduit 20 mm dia or higher ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :- One light point controlled by one way switch 16 Amps
Total amount of Sch 'A' Part IV (Earth work and site clearance) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART V BLANK
Total amount of Sch 'A' Part VI 'A' (Road, Path & Culvert) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VI-B (Road, Path & Culvert)
M & L Applying thermoplastic reflective paint as in road marking of minium 2.50 mm thick single coat of 100 / 150 mm wide using HOT MARK thermo plastic paint (hot application) white golden yellow by indigenous modern property road marking machine as directed
Supply and fixing of 3 MUSA brand markers (cat eyes) made of non breakable polycarbonate with electronically welded primatic Retro reflecive in wet and dry condition with dust proof body complete all as specified and directed.
Construction of RCC hume pipe culvert class NP-2 300mm ,internal dia 6.00 m long (in between parapet ) complete all as specified and shown on drgs.
Construction of RCC hume pipe culvert class NP-2 , 450 mm ,internal dia 6.00 m long (in between parapet ) complete all as specified and shown on drgs.
Construction of RCC slab culvert in RCC M-25 design mix concrete, 610mm clear span, 7.50 M long complete all as specified and and shown on drgs.
Construction of RCC slab culvert in RCC M-25 design mix concrete, 910mm clear span, 7.50M long complete all as specified and shown on drgs.
M & L for 60 mm thick Rubber moulded interlocking tiles laid dry over sand cushioning complete all as specified and directed
Supply and install box type glow sign board of size 1.2m x1.5m, made out of angle iron framed and fixed of white colour acrulic cover both side (front and rear) complete oponable including two number FTL fitting 2 x 40 watt fixed inside board and connected with 3 core cable 4 sqmm from nearest electric point to the board and controlled by one MCB SPN 10 Amp complete including writing work all as specified and directed
S & F Delinators post of 60 cm height from ground level, black or red colour made of 16 guage 48 mm dia MS round pipe heavy duty incl two coats of powder coated black colour paint over one coat of primer with three reflective device all as per MOST & IRC specification and as directed.
Total amount of Sch 'A' Part VII 'A' (Sewage Disposal) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VII-B (Sewage Disposal)
Construction of Septic tank 50 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
Construction of Septic tank 100 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
Construction of Septic tank 200 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
Construction of brick masonry soak well of 1.80 mtr dia & 6 mtr effective depth complete all as specified and directed and shown on drawing
Construction of brick masonry soak well of 2.40 mtr dia & 6.0 mtr effective depth complete all as specified and directed and shown on drawing
Construction of brick masonry soak well of 1.80 mtr dia & 4.50 mtr effective depth complete all as specified and directed and shown on drawing
Total amount of Sch 'A' Part VIII (Area Drainage) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part IX 'A' (Fencing, Compound Wall & Gate) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART IX-B (Fencing, Compound Wall & Gate)
Construction of Steel gate 6.00 mtr wide (clear distance between RCC pillar to RCC pillar) 2.45 mtr high complete all as specified and directed and shown on drawing.
Total amount of Sch 'A' Part X 'A' (External Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART X-B (External Water Supply)
M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 80mm dia complete all as specified and directed.
M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 100mm dia complete all as specified and directed.
M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 150mm dia complete all as specified and directed.
Supply,laying in trenches and testing MS heavy duty ERW Steel pipe 5.40mm thick welded in any shape, and making bends etc including flange 10 mm thick both end including two coat of rubber black paint in outer all complete with fittings etc for following sizes complete all as specified and directed.
150 mm dia
200 mm dia
Supply,laying and testing of cast iron sluice valves of class PN1.6, conforming to relevent IS 14846 including , flanged ends, drilled having stainless steel spindle(ISI Marked) with cast iron wheel at top complete with nut bolts, washer and rubber gasket complete all as specified for following:-
150mm dia
100mm dia
80mm dia
S & F for DI special bends (any radius and angle), tapers any type,(straight, bend, increasing decreasing of double socket etc.) Tee pieces, single branch Y junction, double branch cross /all sockets or socket and spigot, collars caps and plugs etc suitable upto 150 mm dia bore pipe complete all as specified and directed.
M&L for construction of brick masonery valve pit of size 800 x 800 x 800 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and complete all as specified and directed.
M&L for construction of brick masonery valve pit of size 950 x 950 x 950 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing complete all as specified and directed.
Total amount of Sch 'A' Part XI 'A' (External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XI-B (External Electric Supply)
Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- ( MFP )
(i) Incoming ACB 630 Amps 4 Pole 415 volt with thermal release, -1 No
(ii) Outgoing MCCB 200 Amps TP 415 volt 36 KA - 2 Nos
(ii) Outgoing MCCB 100 Amps TP 415 volt 16 KA - 1 Nos
(iii) Outgoing MCCB 63 Amps TP 415 volt 16 KA - 1 Nos
(iv) Outgoing MCCB 40 Amps TP 415 volt 16 KA - 2 Nos (Incl one spare)
(v) Outgoing MCB SPN 40 Amps 230 volt 10 KA - 2 Nos
(vi) Busbar aluminium 1000 Amps with pvc sheeth insulated for TPN - One set.
(vii) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
(viii) Indicator lamp neon type - 3 Nos
(ix) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
(x) PCC plate form with foundation 1 : 2 : 4 = 1 Job
(xi) Multifunctional Degital timer switch Astrorex D 22
(xii) Power contactor of size 40 Amps three pole
Supply and fix APFC panel , out door type mounted on PCC base with 3 x 50 KVAR power factor correction capacitors and to accommodate and include the following fitments complete:
(a) MCCB 500 Amps for incoming -01 No
(b) MCCB 200 Amps for control of 2 x 50 KVAR-02 No
(c) MCCB 100 Amps for control of 1 x 50 KVAR-01 No
(d) Phase indicator lamps LED type-01 set of three
Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-1 )
(i) Incoming MCCB 200 Amps 4 Pole 415 volt 36 KA-1 No
(ii) Outgoing MCCB 63 Amps TP 415 volt 16 KA - 1 Nos
(iii) Outgoing MCCB 40 Amps TP 415 volt 16 KA - 5 Nos
(iv) Outgoing MCB 32 Amps SPN 230 volt 10KA - 5 Nos
(v) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
(vii) Indicator lamp neon type - 3 Nos
(viii) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
(ix) PCC plate form with foundation 1 : 2 : 4 = 1 Job
Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-2 )
(i) Incoming MCCB 200 Amps 4 Pole 415 volt 36 KA-1 No
(ii) Outgoing MCCB 160 Amps TP 415 volt 36 KA - 1 Nos
(iii) Outgoing MCCB 32 Amps TP 415 volt 16 KA - 2 Nos
(iv) Outgoing MCB 40 Amps SPN 415 volt 16 KA - 4 Nos
(v) Multifunctional Degital timer switch Astrorex D 22
(vi) Power contactor of size 40 Amps three pole
(vii) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
(viii) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
(ix) Indicator lamp neon type - 3 Nos
(x) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
(xi) PCC plate form with foundation 1 : 2 : 4 = 1 Job
Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-3 )
(i) Incoming MCCB 100 Amps 4 Pole 415 volt 26 KA-1 No
(ii) Outgoing MCCB 32 Amps TP 415 volt 16 KA - 3 Nos
(iii) Outgoing MCB/Isolator 40 Amps SPN 415 volt 16 KA - 5 Nos
(iv) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
(v) Indicator lamp neon type - 3 Nos
(vi) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
(vii) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
(viii) PCC plate form with foundation 1 : 2 : 4 = 1 Job
M & L for Earthing complete with GI earth plates electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32x6mm connected to earth plate by means of nut ,bolts and washers as directed GI pipe light grade 50mm bore on water pipe from earth chamber to top most edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @150 cc both ways with 10mm dia MS bar in lifting handle excavation earth work including laying of GI pipe in walls etcall as directed in electrical plate No 3 of SSR pt I complete all as specified and directed.
S&F street light fittings HPSV 150 Watts, single piece di cost almn housing and cover vith innovative bright anodised Almn stair case optic lamp compartment, has toughened flat glass cover, IP-66 complete with HPSV Lamp, ballast, Ignitor and other accessories complete all as specified and directed.
M &L for pole box fabricateed out of 1.8mm thick MS sheet having 3 nos busbar 50Amp copper conductor mounted on insulators one no 20x3mm copper bus bar with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc size of box not less then 100x200x80mm front openable hinged cover suitable for mounting on steel using M/S clamps with nut & bolts etc PVC adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
S & F Post Top lantern with conical cover including GI pipe of suitable size upto 2.5 Mtr length including 1 x 70W MH DE (Housing Cat No. LHLM13170D99G and Ballast Cat No. LHBW07170036) lamp connecting with twin core cable 2.5 sqmm upto post box complete all as specified and directed
Supply, fixing, connection and testing of integral flood light luminaries type suitable for 2x400 Watts MH lamp fittings with 40 Watts MH lamp and control gear boxes, suitable size of wiring of luminaries and fixture of high mast light complete all as specified and directed.
Supply and installed MCCB FP 415 volts AC 3 phase 50 HZ 100 Amps capacity 36 KA with sheet metal enclosures on wall /pole -01No complete with locking arrangement complete all as specified and directed.
Supply & fixing of Cable route markers made of galvanized iron with supporting GI angle of size 40 X 40 X 6 mm for stand and plate size 150X150X5mm thick and primering, painting, writing of HT/LT cable route mark for suitable size letters including M/L PCC 1:3:6 type C2 using 40mm graded aggregades in mass concrete or plinth block complete all as specified and directed.
Providing platform for transformer of size 3.0 x 3.0 x 1.0 m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, chain link fencing 1.8m high made out of 4mm dia GI wire 150x100mm mesh MS work angle iron 50x50x6mm as fencing post in embeded in brick /PCC work at 2mtr interval each side as approved 1 No steel gate (3.5m clear) span as shown in drawing with locking arrangement made out of 15mm dia ms rod &50x50x6mm angle iron frame . painting with 2 coat alu paint over a coat of red oxide primer and 3 coats of white washing on cement work including 2 Nos ISMB 100mm chanel for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and directed.
Total amount of Sch 'A' Part XII 'A' (Cable Networking) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XII-B (Cable Networking)
M & L for MAKING OF POINT for Telephone with and including telephone socket RJ-11with metal flush box sand cover plate complete all as specified and directed.
Total amount of Sch 'A' Part XIII 'A' (Lightening Protection) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XIII-B (Lightening Protection)
M & L for Earthing complete with GI earth plates electrode 600 x 600 x 6 mm thick burried directly in ground earth pit not less than 4.50 mtr deep below ground level with top edge of earth plate not less than 1.5m below GL the plate surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32 x 6 mm connected to earth plate by means of nut ,bolts and washers GI pipe light grade 50 mm bore for protection of strips from edge of earth plate to test point including water pipe of size light grade 50 mm from earth chamber to edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50 mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @ 150 C/C both ways with 10 mm dia MS bar in lifting handle including excavation earth work etc all as directed in electrical plate No 3 of SSR pt I complete all as specified and directed.
SCHEDULE 'A' PART XIV (DG Set)
Supply, Errection, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 20.0 KW (25KVA), Air cooled, 415 Volts(AC hree phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Meerut (Capacity of Engine, alternators shall be worked out taking all derating factors into consideratuion) including PCC foundation ( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), antivibration pads,including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged,capabe of giving adequate BHP to drive Alternator capable of delivering 25 KVA(20 KW) at outdoor atmospheric conditions at Meerut (Taking all derating factor into consideration),12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure,overspeed etc) fuel tank and first fill of lub oil and other consumables etc .
(ii)AlLTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 25 KVA/ 20 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
(iiI) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
(iv)AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type , protection class IP-54, duly powder coated after seven tank process,with electrolytic grade copper bus bar of 1000 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
(a) MCCB 415 Volts, 63Amp, rating 4 Pole 25 KA rupturing capacity, Microprocessor based release ,draw out type, specially fixed for incoming supply with overload,short circuit and earth fault protection -2 No with suitable rating HRC back up fuses
(d) Phase indicating lamps(R-Y-B) -1 set
(e) Frequency meter digital type 45 to 55 HZ-1 No
(f) All standard relays , circuits and protection required for automatic operation of Gen set
(V) ACOUSTIC ENCLOSURE:Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set wheh DG set is working at full load alongwith testing confirmance, labelling certification etc as laid down in GSR No 371(E) dt 17 May 2002.
(VI) Foundation/Plinth/Base:Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M
(VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set.
(VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, gurantee card etc shall be provided as per manufacturer standard practices.
Supply, Errection, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 256.0 KW (320 KVA), Water cooled, 415 Volts(AC hree phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mountd on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Meerut (Capacity of Engine, alternators shall be worked out taking all derating factors into consideratuion) including PCC foundation ( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), antivibration pads,including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged,capabe of giving adequate BHP to drive Alternator capable of delivering 320 KVA(256 KW) at outdoor atmospheric conditions at Meerut (Taking all de-rating factor into consideration),12/24 Volts(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure,overspeed etc) fuel tank and first fill of lub oil and other consumables etc .
(ii)AlLTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 320 KVA/ 256 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
(iiI) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
(iv)AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type , protection class IP-54, duly powder coated after seven tank process,with electrolytic grade copper bus bar of 1000 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
(a) MCCB 415 Volts, 630Amp, rating 4 Pole 70 KA rupturing capacity, Microprocessor based release ,draw out type, specially fixed for incoming supply with overload,short circuit and earth fault protection -2 No with suitable rating HRC back up fuses
(d) Phase indicating lamps(R-Y-B) -1 set
(e) Frequency meter digital type 45 to 55 HZ-1 No
(f) All standard relays , circuits and protection required for automatic operation of Gen set
(V) ACOUSTIC ENCLOSURE:Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set wheh DG set is working at full load alongwith testing confirmance, labelling certification etc as laid down in GSR No 371(E) dt 17 May 2002.
(VI) Foundation/Plinth/Base:Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M
(VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set.
(VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, gurantee card etc shall be provided as per manufacturer standard practices.
SCHEDULE 'A' PART XV (Water Cooler, Referigerator, Desert Cooler and Geyser)
Supply and Installation ,Comisioning and Testing of Refrigerator with non CFC refrigrent type electric driven single phase of capacity 310 / 325 Ltrs ,frost free,double door air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
Supply and Installation ,Comisioning andTesting of,Refrigerator with non CFC refrigrent type frost free double door electric driven single phase of capacity 265 Ltrs, air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
Supply and Installation ,Comisioning andTesting of,Refrigerator with non CFC refrigrent type frost free double door electric driven single phase of capacity 205 Ltrs, air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
Supply and Installation Deep freezer with metal top,non CFC refrigerant type, electric driven (single phase) of capacity 300 / 320 Ltrs, frost free complete all as directed.
Supply and Installation ,Comisioning and testing of water cooler non CFC refrigerant type electric driven (single phase ) having storage capacity of 80 Ltrs & nominal cooling capacity 40 Ltrs/hr complete including connecting cord,PVC Connection & plug top handling, connecting up with 20mm GI pipe medium grade complete all as specified & directed.
Supply and Installation ,Comisioning and testing water cooler non CFC refrigerant typeelectric driven (single phase ) having storage capacity of 150 Ltrs & nominal cooling capacity 60 Ltrs/hr complete including connecting cord,PVC Connection & plug top handling, connecting up with 20mm GI pipe medium grade complete all as specified & directed.
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 0.50 KVA complete all as specified & directed.
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 1 KVA complete all as specified & directed.
S&F automatic operation single phase stablizer,naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 2 KVA complete all as specified & directed.
Supplying & Installation commissioning and testing, Desert cooler made out of 1mm thick MS sheet ,electric driven(S.P),230 volts,AC,air flow capacity 4000Cum/Hr,blade size 406/16 mm ,PVC body,3 speed,1400 RPM,160 watt,45 ltrs water tank cap,motorisedloures movement,top water inlet complete with pump & motorcomplete all as specified & directed.
Total amount of Sch 'A' Part XVI 'A' (Solar Water Heater) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XVI-B (Solar Water Heater)
Supply, installation, commissioning of solar water heating (Flate plate collector) system with heat exchanger suitable for cold resion of capacity 200 ltr complete with solar panels with copper tubes alongwith insulated hot water storage tank double body, system shall be electrical heating back up of 3 KW with necessary safety control ,thermostates ,hot water temp gauge etc complete in all respect including hot water pipes shall be insulated with best quality of insulating material / glass wool duly binded with chicken wire mesh and covered with aluminium sheet duly clamped complete all as specified and directed.
Supply, installation, commissioning of solar water heating (Flate plate collector) system with heat exchanger suitable for cold resion of capacity 100 ltr complete with solar panels with copper tubes alongwith insulated hot water storage tank double body, system shall be electrical heating back up of 2 KW with necessary safety control ,thermostates ,hot water temp gauge etc complete in all respect including hot water pipes shall be insulated with best quality of insulating material / glass wool duly binded with chicken wire mesh and covered with aluminium sheet duly clamped complete all as specified and directed.
S & F water storage type electric geyser supplied and installed 25 ltrs capacity complete all as specified and directed.
Supplying and fixing ball valve high pressure PTMT with epoxy coated alluminium rod etc complete all as specified and directed of following size :-
SCHEDULE 'A' PART XVII (Split Airconditioner)
Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 2TR minimum 3 star rating and EER3.2 complete all as directed.
Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 1.5 TR minimum 3 star rating and EER3.2 complete all as directed.
Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 1 TR minimum 3 star rating and EER3.2 etc complete all as directed.
S & F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 4KVA complete all as directed.
S & F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 5KVA complete all as directed.
SCHEDULE 'A' PART XVIII (Solar Street Light)
Supply and fixing Solar energy operated street light 14 watts LED including fitting suitable size of cable with accessories ,pole , battery 12V 100 AH, battery box with locking arrangement , solar panel of suitable capacity complete including PCC foundation for pole using PCC 1:3:6 type C-1 using 20 mm stone aggregate complete all as specified and directed
SCHEDULE 'A' PART XIX (Fire Fighting)
Supply & Installation of portable fire extinguishers ABC Powder type 5 Kg capacity,as per IS-2171/13849,14609, wall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed.
Supply and fixing fire beaters with 20 feet long handle with red enamel paint and written "Fire" on bucket complete all as specified and directed.
Supply and fixing sheet metal fire Buckets duly painted with red enamel paint and written "Fire" on bucket complete all as specified and directed.
Supply and fixing fire Axe with suitable handle duly paintd with red enamel paint all as specified and directed complete all as specified and directed.
Supply and fixing fire hooks with 20 feet long handle duly paintd with red enamel paint all as specified and directed complete all as specified and directed.
SCHEDULE 'A' PART XX (Walk in Cold Room)
Supply, installation, testing and commissioning of Walk - in cold room of two chambers, Freezer Room of size 8' x 8' x 8' consisting of wall and ceiling panel made out of PGI sheet filled with 120 mm PUF insulation, and Ante Room of size 5' x 5' x 8' consisting of wall and ceiling panel made out of PGI sheet filled with 60 mm PUF insulation, for Blood Bank and other low temperature application , anti skid GI flooring on 60 mm PUF, door of suitable dimension, hydraulic door closer, digital temperature indicator, Air cooled low temperature split unit of 2 HP rating with Reciprocating / Scroll Compressors working on R - 22 / R - 410 a refrigerants to maintain temperature of 4+ / - 2 degree Centigrade at an ambient temperature of 30 degree centigrade.etc complete all as specified and directed.
Supply & fix automatic boost / buck transformer for low and high voltage correction, input voltage 160 to 280 Volts and output Voltage 230 equipped with electronic transistorized relay suitable for correction and cut out 280 Volts on single phase, 50 cycle of 140 Volts to 290 Volts and output voltage stabilized between 215 Volts to 240 Volts capacity 5 KVA and time delay rely 3 minutes complete all as specified and directed.
Total amount of Sch 'A' Part XXI (Paved Area for Patient vehicle Parking) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XXII (Strengthening Measures)
Excavation upto the foundation of column approx @ 2..5 m depth and 2.5 m wide, 2.5 m length below the ground level complete all as specified and directed.
Providing & fixing of extra L-type (column) shear rebar connector 10mm with Hilti / Fischer / Sika Anchor fix or its equivalent chemical including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with epoxy to ensure the bond and straightening, cutting, bending, placing in position binding with GI wire of 18 gauge complete all as specified and directed.
Providing & fixing of extra rebar 12mm dia * 120mm depth vertically, providing extra rebar with hilti / fischer / sika Anchor fix or its equivalent chemical including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with epoxy to ensure the bond and straightening, cutting,bending, placing in position, binding with GI wire of 18 gauge complete all as specified and directed.
Providing extra reinforcement with TMT bars as per site design requirement including straightening, cutting, bending, placing in position, binding with GI wire of 18 gauge etc complete in all respects. Additional reinforcement with adequate lap length & rings at required spacing shall be tied with existing reinforcement using binding wire or welded complete all as specified and directed.
Providing, mixing, and applying two component epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacture specification including preparation of surface by chipping and thoroughly cleaning of surface complete all as specified and directed. Product Sikadur 32 LP, Consumption @ 04 kg / sqm, Product requirements complies with ASTM C 881 Type II including carriage of materials with in all lead and lifts.
Providing and fixing water tight centring and shuttering including carriage of materials with in all leads and lifts complete all as specified and directed.
Supply and apply a ready to use non shrink, cementitious free flow micro concrete with addition 6mm down aggregate complete all as specified and directed. Product- SiakRep Microcrete-4 / equivalent, Yield: Approx 17 litre per bag (30Kg), Product requirements Compressive strength > 60 N / Sqmm (28 days) according to ASTM C 1107-99, including carriage of materials with in all leads and lifts.
Drlling and fixing injection packers in RC members including and complete all as specified and directed. Drilling Holes:- Drilling holes in structural members at the intervals as per recommendation of Engineer-in-charge. Cleaning of holes:- Clean the holes by air blower prior to fixing nozzles. Fixing of packers:- Insert 12mm dia, 50-75 mm long injection packers in cleaned holes with moisture insensitive epoxy resin based putty or equivalent. Cutting of packers:- Cut the packers by cut of wheel after completion of grouting without damaging structural elements.
Supply a epoxy resin based injection grout complete all as specified and directed. Product ID Sikadur® -52 or its equivalent, viscosity 350 Cps at 25 degree celcius, Mixed Density - 1.15 Kg / litre at 25 degree celcius Product requirements : bond strength > 10 N / Sqmm or concrete failure according to ASTM C 882 at 30 degree celcius, compressive strength > 90 N / Sqmm (25 degree celcius) according to ASTM D 695 including carriage of materials with in all leads and lifts.
Note : Tenderers may note that amount of credit Rs 10,62,868.43 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Mahalaxmi Construction
Shree Construction Co.
VEE SONS BUILDERS PVT LTD
M/s Chitter Mal & Co.
SOOD ASSOCIATES PVT LTD
PK Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid