Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.4 L+₹4.2 L (13.0%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L2 | Rejected-Finance L2 | |
| 3 | L3₹37.8 L+₹5.6 L (17.3%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹38.4 L+₹6.1 L (19.0%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L4 | Rejected-Finance L4 |
Tender Value
₹43.3 L
EMD Value
₹86,607
Closing Date
17 Aug 2022, 6:00 pmClosed
AGM EE
AGM EE,VSS Airport,Jharsuguda
Expansion of Apron for 4 Nos. of AB320 Type of Aircraft with new Link Taxiway and allied works at VSS Airport, Jharsuguda. SH Electrical Work GLF works
2022_AAI_123628_1
AAI/JSG/AGM(EE)/eNIT-4/2022
Open Tender
Electrical Works
Sale
180 days
VSS Airport Jharsuguda
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
₹86,607
28 Sept 2022
27 Jul 2022
19 Aug 2022
28 Jul 2022
17 Aug 2022
28 Jul 2022
28 Jul 2022 - 1 Aug 2022
Amount
Supply of 5 KV grade, multi stranded tinned copper conductor, XLPE insulated,Polyethylene sheathed, single core and with inner and outer semi conductor, underground cable or airfield lighting generally as specified in tender specification of the ollowing sizes as required. a) 6 sq mm
Supply of elevated type LED Taxiway Edge light fitting (MIRL fitting) for use as Taxiway / Apron Edge /Turning Pad lights suitable for operation at 2.8 Amps to 6.6 Amps series circuit supply current complete with suitable LEDs, omni-directional lens, lens clamping mechanism, breakable coupling, rings /gaskets, base plate with 06 nos. M-10 stainless steel bolts and including an integrated encapsulated suitable electronic converter with standard secondary lead etc. complete fitting confirming to latest ICAO standards / requirement complete as required & direction of Engineering In-Charge..
Supply of 15 Watt 6.6 Amps /6.6 Amps, 5 KV grade 50 Hz Isolating transformer series type encapsulated in neoprene type rubber with primary and secondary two pin leads as specified in technical specification as per site condition & direction of Engineering In-Charge.
Supply of following size copper conductor two pin secondary leads with one side male connector and other side female connector suitable for airfield lighting system and conforming to particular technical specifications etc. complete as required, as per site condition & direction of Engineering In-Charge. Size : - 2 X 2.5 Sq. MM & minimum 0.3 meter long .
Supplying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS with upto date amendments ,complete as per site condition & direction of Engineering In-Charge. A) 63 mm dia (OD),PN-8,PE-100.
Laying of following size HDPE pipe at a depth of 0.8Mtr along with all accessories like socket, bend, couplers etc. Complete with fitting and cutting, jointing etc. direct in ground including excavation and making good surface as per site condition & direction of Engineering In-Charge. Size 63 mm dia (OD),PN-8,PE-100.
Supply and drawing of following Size of FRLS PVC insulated multistand Copper Conductor cable in the existing Steel/PVC Conduits/HDPE Pipe for secondary supply of GLF fitting from isolating transformer and making jointing with both end two pin secondary leads as per tender specification, site condition & direction of Engineering In-Charge. (a) Size: 3 x 2.5 sq mm copper conductor cable (3 runs of 2.5 sqmm)
Installation, Testing, and Commissioning of elevated type high intensity runway edge /approach light/Taxi light fitting all other accessories complete as required as per site condition & direction of Engineering In-Charge.
Supply of C.I isolating transformer housing box, water tight round type, metal container of outside size 330 mm height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at three side surface centre 75 mm above bottom surface suitable to receive of 63 mm dia (outer dia) HDPE/G. I. pipe and including check nuts as required and another hole at 175 mm from the bottom of the CI box to receive one no. 15 mm dia, "B" class, GI pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, "B" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts as required as per the drawings.(triple Hole type).
supply of CI collars of 50 mm height ,330mm dia,10mm thick CI moulding all around except top surface which is 15mm thick with 220mm opening on top & bottom, with 6nos. m-10 tapped hole on top and 6nos. through holes at bottom to pass m-10 bolts with three holes suitable to receive 50 mm dia (outer dia) HDPE/G. I. pipe
Installation of transformer housing box / collar as per site with a 100mm thick base concrete of 1:3:6 & all round concrete of 1:2:4 of 150mm thick along with top sloped as specified i/c providing & fixing 250 mm long 15mm dia "B" class G.l Pipe with check nuts at the bottom surface for drainage of water i/c excavation, alignment & refilling as reqd & as per drawing and specifications, as per site condition as per direction of Engineering In-Charge.
Installation of transformer housing box collar as per site with a 100mm thick base concrete of 1:3:6 & all round concrete of 1:2:4 of 150mm thick along with top sloped as specified i/c excavation, alignment & refilling as reqd & as per drawing and specifications, as per site condition as per direction of Engineering In-Charge.
Making field connections by crimping 6/16 sq. mm plug and receptacle with existing 6/16 sq. mm single core PVC copper conductor cable including filling the gap with water sealant material and applying PVC insulated tape etc. complete as required, as per site condition & direction of Engineering In-Charge.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 5 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required, as per site condition & direction of Engineering In-Charge. A) up to 25 Sq mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 5 KV grade of following size on wall surface / trench as required, as per site condition & direction of Engineering In-Charge. A) up to 25 Sq mm.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required, as per site condition & direction of Engineering In-Charge.
Supply and laying of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required, as per site condition & direction of Engineering In-Charge.
Design Supply, Installation, Testing and commissioning of indoor type Microprocessor based Constant Current Regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50hz., AC supply, Control voltage: 48VDC ,provision for control supply with switchgears, CCR protections, connection/ inter-connection etc. Complete as required as per tender specification & direction of Engineering In-Charge. 20 KW, 6.6A output current.
Design Supply, Installation, Testing and commissioning of indoor type Microprocessor based Constant Current Regulator (CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50hz., AC supply, Control voltage: 48VDC ,provision for control supply with switchgears, CCR protections, connection/ inter-connection etc. Complete as required as per tender specification & direction of Engineering In-Charge. 7.5 KW, 6.6A output current.
Constructing brick masonry chamber of size 1200x1200x1200mm of size in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 15 mm thick with cement mortar 1:3 (1 cement: 3 Coarse sand) finished with floating coat of neat cement foundation concrete 1:3:6(1 cement: 3 coarse sand:6 graded stone aggregate 40 mm nominal size) all complete as per standard design with cover of 75 mm thick ness made by RCC in cement mortar 1:2:4(1 cement: 2 coarse sand:4 graded stone aggregate 40 mm nominal size) in two piece with 12 mm rod handle in order to easy handling and as per Tender specifications and as per directions of Engineer-In-charge.
SITC of internally illuminated LED based Mandatory / Information /Location/VOR check point Runway / Taxiway guidance age of various sizes made out of 4mm thick glare free poly carbonate sheet at front and body made out of 2.0mm thick powder coated aluminum profile having minimum width of 150mm and supported at back by 50mm dia, 3mm thickness, die cast aluminum pipe at a separation as required, and frangible coupling as required. Light source shall be high luminous, long life typical 50,000 Hrs. type, 0.5 Watts LED's assembled on aluminum PCB. The thickness of the aluminium PCB should be 2mm in order to ensure proper heat dissipation. These aluminium PCB’s should be placed not more than 160mm apart across the length of the board in order to ensure uniform distribution of light across the board. Each board having length from 800mm up to 3000mm should be illuminated by a single converter & by using single isolating transformer of suitable wattage in order to save the capital cost of multiple isolating transformers. Signage shall be suitable for operation on series circuit at variable current from 2.8Amp - 6.6Amp and will give constant brightness for all current variation. All the signage shall have letters and symbols made by computerized cutting of vinyl and pasting on the polycarbonate sheet from inside/outside of the sign face of required color as per ICAO.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed by EIC as per site condition.
Vardhman Airport Solutions Pvt Ltd
Manish Electricals
Techno Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .