| # | Company | Offered Item | Status |
|---|---|---|---|
| 1 | Qualified Make: AGFA
Model: DR 400i
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Make: AGFA
Model: DR 400i
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Qualified MII |
| 2 | Disqualified Make: ERAY
Model: ERAY RAD 500S
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY 154 1ST FLOOR SHAKTI VIHAR PITAMPURA NEW DELHI NEW DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: ERAY
Model: ERAY RAD 500S
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Disqualified MSE, MII, Category: General |
| 3 | Disqualified Make: PRORAD
Model: PRORAD 2FC
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Make: PRORAD
Model: PRORAD 2FC
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Disqualified MII |
| 4 | Disqualified Make: STAR NUKE--STAR NUKE CONSULTING ENGINEERING SERVICES PRIVATE LIMITED
Model: STARNUKE-HF300
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY PLOT NO 25 NAVKAR NAGAR VILLAGE KALYANPURA SANGANER ROAD POST SANGANER SANGANER JAIPUR RAJASTHAN 302020 | JAIPUR | RAJASTHAN | 302020 | Make: STAR NUKE--STAR NUKE CONSULTING ENGINEERING SERVICES PRIVATE LIMITED
Model: STARNUKE-HF300
Title: SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY | Disqualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 May 2026, 9:00 amClosed
SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY Floor Mounted Direct Radiography System with Dual Detector Floor Mounted Direct Radiography System with Dual Detector:- 1.Generator The Generator should be high frequency capacity of 30 KW or more. KV range should be 40 KV- 125 KV or more. The output at 80 KV should be 400 mA or more. Generator frequency should be 200khz or more 2. X-Ray Tube and Collimator The X-Ray Tube should be of rotating anode with dual focus having the following sizes: (i) Large focus: 1.5 mm or less. (ii) Small focus: 0.6 mm or less The unit should have Anode Heat Storage capacity of 100 KHU or more. Distance measuring scale should be provided. Should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. The light output should be minimum 160lux Tube rotation on vertical axis should be - 180 degree locked (Clockwise) & + 120 degree (anticlockwise) at least with end stopper. The tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. Touch screen display on Tube head to control Kvp & Mas as well as selection of body parts. 3. Vertical Detector Stand The unit should be provided with vertical stand. The unit should have provision to do all upright X-Rays. The vertical Detector should travel from at least 1.4 ft to 5.5 ft above floor level. It should be flat vertical motion can be locked in any position. 4. Table The table top should be floating with transverse and longitudinal movements 250 mm
300 mm respectively or better. The table should have a weight bearing capacity of minimum 200 kg or more. The table should have anti scatter grid Electromagnetic
9171576
GEM/2026/B/7398823
Two Packet Bid
SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY
Karnataka; Bengaluru Urban
Total value wise evaluation
PRODUCT_CUSTOM
2 documents required · 2 mandatory
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR UNDER BUY-BCAK POLICY Floor Mounted Direct Radiography System with Dual Detector Floor Mounted Direct Radiography System with Dual Detector:- 1.Generator The Generator should be high frequency capacity of 30 KW or more. KV range should be 40 KV- 125 KV or more. The output at 80 KV should be 400 mA or more. Generator frequency should be 200khz or more 2. X-Ray Tube and Collimator The X-Ray Tube should be of rotating anode with dual focus having the following sizes: (i) Large focus: 1.5 mm or less. (ii) Small focus: 0.6 mm or less The unit should have Anode Heat Storage capacity of 100 KHU or more. Distance measuring scale should be provided. Should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. The light output should be minimum 160lux Tube rotation on vertical axis should be - 180 degree locked (Clockwise) & + 120 degree (anticlockwise) at least with end stopper. The tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. Touch screen display on Tube head to control Kvp & Mas as well as selection of body parts. 3. Vertical Detector Stand The unit should be provided with vertical stand. The unit should have provision to do all upright X-Rays. The vertical Detector should travel from at least 1.4 ft to 5.5 ft above floor level. It should be flat vertical motion can be locked in any position. 4. Table The table top should be floating with transverse and longitudinal movements 250 mm | - | - | - |
| 300 mm respectively or better. The table should have a weight bearing capacity of minimum 200 kg or more. The table should have anti scatter grid Electromagnetic | - | - | - |
Exempted
Yes
27 Apr 2026
28 Mar 2026
15 May 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9171576.pdf
GEM_BID
scan2026-03-28_101710_2026-03-28-10-18-49_3b0bfa33fccbdb8f4dc0301dfab493a9.pdf
SPECIFICATION
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
scan2026-03-28_101710_2026-03-28-10-18-49_3b0bfa33fccbdb8f4dc0301dfab493a9.pdf
GEM_SPEC • 0.68 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .