| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC Accepted lowest bid quoted | |
| 2 | L2₹42.0 L+₹1.1 L (2.72%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹43.1 L+₹2.3 L (5.58%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Dec 2022, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIRS TO PLASTERING TILLING FLOORING JOINERY SANITARY FITTINGS PLUMBING AND MISC REPAIR WORKS TO BLDG IN SAFED SAGAR AREA AT AFSSR GURGAON AND REPAIR MAINTENANCE OF SUMMER APPLIANCES AC PLANTS AFSSR AC PLANTS NTS AND ALLIED WORKS AT AF STN GURGAON
2022_MES_560073_2
CA NO GE/GUR-/NIT-48/2022-23
Open Tender
Civil Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹80,000
28 Jan 2023
2 Dec 2022
26 Dec 2022
2 Dec 2022
23 Dec 2022
9 Dec 2022
Amount
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc. Complete all as specified & directed
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and smooth without using extra cement complete all as specified and directed. Note:- Area includes in this items upto 4 stories of building.
M&L for rendering 15 mm thick on brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces on ceiling/ struts 1n patches in CM 1:3. finishing even and smooth without using extra cement complete all as specified and directed.
M&L for Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the Ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed.
M&L for preparing newly Rough Cast Plastered Surfaces of Walls and applying Two Coats of Weather Coat Exterior Paint (in Camuflage/ Plain pattern as ordered) with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:3) on RCC Chajja / Facia / Roof projection over 20mm thick in CM 1:4 as doubing coat including cleaning of old wornout concrete,taking down plaster & applying a coat of RBR compund for proper bond of old and new concrete surface etc complete all as specified and as directed Notes : Area includes in this items up to 4 th stories building.
Demolition reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas, Shelves and similar suspended work (reinforcement cut as required to facilitate demolition)
M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roofs, chajjas,Shelves, beams complete all as specified and directed.
Use and waste of form work to Chullah hoods, chajjas, shelves, weather shades,suspended slabs, corbels, water troughs and similar items including edges rough finished surfaces of concrete complete all as specified and directed
S&F mild steel TMT bars 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified and directed
Hacking out old brocken glass ( any thickness , size , quality or description ) from wooden frames or stone, concrete or brick surrounds , glazed with putty or fixed with beads and removal for site complete all as specified and directed by Engineer-in-Charge
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty or fixing in NCL windows with rubber beading in square n exc 0.5 sq.m. in each pane complete all as specified and directed by Engineer-in-Charge
M&L for three coats of white wash on New plaster surface of ceiling including prepration of surface.
M&L for One coat of white wash on old plaster surface of ceiling including prepration of surface.
M&L for preparation of old plaster surface of walls and applying two coats of white wash over a coat of cement primer complete as specified and as directed.
M&L for preparing new plastered surface of walls and applying two coats of oil bond distemper white or any tint over a coat of primer etc complete as specified and directed
M&L for completely removal of the existing treatment by wire brushing or sand paper or other scraping material as required from wall including prepration of surfaces complete as specified and directed.
M&L for preparing Old plastered surface of walls and applying two coats of oil bound distemper white or any tint etc complete as specified and directed
M&L for preparing Old plastered surface of walls and applying one coat of oil bond distemper white or any tint etc complete as specified and directed
M&L for 2mm thick birla white putty and making the surface smooth etc complete as specified and directed
M&L for preparation of newely plastered surface of wall and applying two coats of cement base paint over a coat of primer etc complete all as specified and as directed. Notes : Area includes in this items up to 2nd storied building.
M&L for preparation of old plastered surface of wall and applying two coats of cement base paint over a coat of primer etc complete all as specified and as directed. Notes : Area includes in this items up to 2nd storied building.
M&L for completely removal of the existing treatment from wall,chajjas,facia and preparing plaster surface of wall and applying two coat of exterior weather proof paint overr a coat of primer etc complete all as specified and directed. Note : Area includes in this items upto 2nd storied building.
M&L for preparation of newly plastered surface of wall,chajjas,facia and applying two coat of exterior weather proof paint over a coat of primer etc complete all as specified and directed. Note : the area includes in this items upto 2nd storied building.
M&L for preparation of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L two coats of synthetic enamel painting on old steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of surfaces
M&L for preparation of new steel surface of any description, not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames from the opening of size exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed.
Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete all as specified and directed
Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete and refixing in the same opening after easing and adjustment all as specified and directed
S&F window/ventilator section of frame 72x55 mm fixed to wall or concrete surface with rawl plugs made, of galvanized steel powder coated and section of shutter 47x20 mm, mulion section 72x50 mm (Base steel as per IS 513 "D" quality galvanized as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6 mm including grills/guard bars made of square bars powder coated fixed to windows frame with screws at 150mm c/c both ways, 4 to 5 mm thick plain/figured sheet glass , 0.36mm stainless steel wire cloth with 1.40mm aperture necessory fittings and all builders hardware such as handles, tower bolts & stays etc. complete all as specified and as directed Make:- NCL type-4000 series.
S&F Aluminium anodized powder coated Window Double Shutters Glazed and Gauged of Stainless Steel Wire Cloth having nominal dia of Wire 0.36mm and average width of aperture 1.40mm along with Aluminium Section with 50 micron anodizing size of Frame 125x44.5mmx16 gauge having size of Shutter, Top/ Bottom/central Rail shall be 44.5x44.5mm x16 gauge Aluminium Section with 50 micron anodizing and 5.5mm thick Black/ Tinted Sheet Glass to be fixed on Glazed Portion including Aluminium Grill and Stainless Steel Hooks and Eye to be provided as stay of Shutters, etc. complete including necessary Jointing Cleats, Glazing Clips, Rubber Packing, Aluminium Snap Beading, Screws anodized Aluminium Fittings such as Peg Stay 150mm long (1 No. for each Leaf), Hinge Type B-21 of 100mm long (2 No. for each Leaf), suitable Handle (1 No. for each Leaf) and 100mm Aluminium Tower Bolts (2 No. in each Leaf), complete all as specified and as directed.NOTE : Cost of Black/Tinted Sheet Glass, Stainless Steel Wire Cloth, Jointing & Packing Materials, anodized Aluminium Fittings, etc. shall deem to be include in the Quoted Unit Rate.
S&F pressed steel frames 1.25mm thick for door size of frame 105 X 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and two coats of synthetic enamel paint to outer surface with red oxide primer after prepration of surfaces complete all as specified and directed.
S&F pressed steel frames 1.25mm thick for door size of frame125 X 60mm with double rebates including necessary fixing lugs, hinges, lock strike plate and filling of chowkats with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) and for filling of hold fast and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges and two coats of synthetic enamel paint to outer surface with red oxide primer after prepration of surfaces complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 95mm made out of 5 mm wood grain printed PVC sheet reinforced with MS Squre Tube in opening etc complete all as specified and as directed
S&F Factory made solid panel pvc door shutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side Prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement including rawl plugs etc in the frame at site as per specification & drawing etc complete all as specified as directed.
S&F IInd class hard wood 35mm thick Plain framed, factory made, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply on both faces. (The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated) complete all as specified and directed
S&F 35mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed.
S&F IInd class hard wood Glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
M&L for preparation of new wooden surface of any description, not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed
Supply and fix Godrej pattern mild steel cup board with shutter made out of 18 guage M.S. sheet 60cm depth sides incl with back & 3 shelves & vertical partition & mild steel door shutter two leaves with frame, incl necessary fittings with locking arrangement and handle etc all as per Godrej Pattern with duplicate keys including necessary fittings & two coats of spray painting over a coat of red oxide zinc chromate primer complete. The cupboard to be fixed to wall with 6 Nos of hold fasts of 25 x 3mm flat iron, 15cm long. The cost of hold fasts & grouting them in CM (1:3) is deemed to be included in unit rates (Only front face of cupboard to be measured) complete all as specified and as directed.
M&L for 18/19mm thick Block Boards, grade 1 quality , exterior grade, commercial type, fixed with screws to timber frame work.
S&F 100mm size, hasp and staple safety type, aluminium with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-charge.
S&F factory made PVC shutter/Shelves in required size at shape made out of 18mm thick PVC Celuka ply one side decorative lamination and other side plain/colour complete including required frame work with panels shall be fabricated using adhesive, screws and solvent cement etc where ever required all the edges shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent complete all as directed by Engr-in-Charge.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in complete all as specified and directed by Engineer-In- Charge.
S&F 30mm wide flaps continuous (Piano) hinges mild steel bright finish complete all as specified and directed by Engineer-In- Charge.
S&F 40 mm dia cup boards knobs fixed with nut , screw and washer of mild steel , bright finished Complete all as specified and directed.
S&F Mild steel sliding door bolts 300mm long with hasp, staple (bolt type) , stove enameled black with bolt not less than 12mm dia with and including a minimum of 6 bolt and nut complete
S&F Mild steel barrel tower bolts, 150mm size, stove enamelled black, with bolt complete all as specified and directed
S&F aluminium anodised barrel tower bolt of extruded section 200mm size, stove enamelled black, with bolt complete all as specified and directed
S&F 150mm long mild steel pressed handle, oval type, stove enamelled complete all as specified and directed
S&F Aluminium handles, 150mm size cast type anodised complete all as specified and directed
S&F Double legged Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm.
S&F stainless steel 75 mm long butt hinges for PVC door shutters and frames complete all as specified and directed by Engineer-in-Charge.
Supply only Butt Hinges, 100mm size, medium weight, cold rolled mild steel complete all as specified and directed
S&F 300mm long ordinary rat tail rod pattern spring, including roller and roller plate.
Demolition of Cement Concrete in sunken floors and pavings exc 15 cm thickness above ground level and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:3 with water proofing compound, finishing even and smooth without using extra cement complete all as specified and directed
Supply only integral water proofing compound.
M&L for applying evenly a coat of epoxy compound of Dr Fixit or equalvent as approved by Engrineer-In-Charge as in sunken portion of WC including cleaning surfaces complete all as specified and as directed
M&L for Cement concrete 1:7:12 type F-2 (using 40mm graded brick aggregates) as in foundations, filling and mass concrete complete all as specified and directed
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finishing even and smooth without using extra cement complete all as specified and directed
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed.
M&L for Non skid Double-charged, ceramic coloured tiles 9 to 10 mm thick area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jounted neat cement slurry and pointed in white or coloured cement to match the surface of tiles over and including 15 mm thick screed bedding layers in CM (1:4) complete all as specified and as directed.
M&L for non-skid tiles ceramic coloured tiles 7 to 8 mm thick of size 400mmx400 mm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles over and including 15 mm thick screed bedding layers in CM (1:4) complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete wall surface as backing coat of dado/skirting etc complete all as specified and as directed
M&L for Glazed ceramic tiles coloured 300mmx 450mm, 6 to 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match etc on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match etc complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions etc complete all as specified and as directed
M&L for granite (Black) stone slab 16-18 mm thick machine cut and machine polised, in skirting, Kitchen platform /dado etc laid over cement screed jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including pinning in brick/concrete wall to hold & support the vertical surfaces to granite work including drilling to wall & including screed bed 15 mm thick in cement mortar 1:4 complete all as specified and as directed by Engineer-In- Charge.
S&F in repair sink made od stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf walls , or including fixing cantilever brackets and connecting union to waste pipe overall size 495mmx 330mmx 160mm including waste coupling and waste pipe complete all as specified and as directed by Engr-in-charge.
S&F in repair vitreous China Squatting pan 'Orrisa' pattren size 580x440mm white with integral foot rest, 'P' or 'S" trap cement concrete bedding complete all as specified and directed.
Supply only 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve float, handle including bracket complete all as specified and directed with glaged finish.
Supply only Flush pipe of polythylene of low or high density or PVC,32mm dia for low level cistern.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm.
S&F in repair tubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed
S&F in repair chromium plated shower roses 125 mm with or without swivel joints,any size including fixing to steel pipe or union for 15mm bore of pipe complete all as specified and directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
Dismantling of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed
S&F rotational moulded polythene, triple layers, water storage tank 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position incl S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl Dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr.
Disconnecting existing tanks 500 ltr capacity, setting aside (or lowering of required) for repairs , cleaning, etc. and hoisting if required reconnecting and refixing in position incl Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipes, etc and write date of cleaning on tank complete all as directed by Engr-in-Charge.
S&F in repairs 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore complete all as specified and as directed
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 15 mm bore complete all as specified and as directed
S&F and testing galvanised steel tubing 15mm bore “medium grade” with all fittings complete fixed to wall surfaced/concelled incl Taking down or up steel tubing 15mm bore and connections and complete all as specified and directed
S&F and testing galvanised steel tubing 20mm bore “medium grade” with all fittings complete fixed to wall incl Taking down or up steel tubing 20mm bore and connections and complete all as specified and directed
S&F in repair stop valves/angle valves fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fixed for 15 mm dia bore dia pipe complete all as specified and as directed
S&F in repair Stop valves, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions, fancy type, chromium plated with long shank and cup ( concealed type) and fixed 15 mm dia bore dia pipe complete all as specified and as directed.
S&F in repair Bib taps, cast copper alloy chromium plated, fancy type with crutch or butterfly handle , screwed down , scrwed for iron pipe or for brass ferrule and fixed for 15 mm dia bore dia pipe complete all as specified and as directed.
S&F 15mm bore Pillar taps fancy type, cast copper alloy, with long swan neck, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed
S&F in repair vitreous China wash basin white, flat back size 550x400mm including S&F 32mm dia waste coupling, waste PVC pipe complete all as specified and as directed.
S&F in repair kitchen plate rack stainless steel 1 mm thick of size 90cmx75cmx30cm complete fixed to brick/concrete wall, with screw including rawl plug complete all as specified and as directed
Cutting holes in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting angle iron and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l required etc for exc half brick but n.exc one brick complete all as specified and as directed Note:- The work shall be carried out up to G+1 storey and the quoted rate shall be inclusive of all connected items like, scaffolding, etc nothing extra shall be admissible on this account.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening FE-410-W Gde (E-250 quality) and fixing complete all as specified and as directed
S&F in repairs stainless steel decorative curtain rod of 25 mm bore including stainless steel finale & bracket etc complete all as specified and as directed
Removing excavated / demolished materials exc 250 m but n-exc 500m and depositing complete all as specified & directed by Engr -in charge.
S&F in repair Locks for cup board, grade I, size 75 mm Brass 4 Levers, incl easing and repair to steel cupboard complete all as specified and directed by Engr-in-Charge.
M&L for Surface Preparation incl Surface to be free from APP Membrain , frost, surface laitance and contamination and free from loose aggregate, incl taking down cement plaster complete all as directed by Engr-in-Charge.
M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings, roof padding/staging of water tank etc including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L for 15 mm thick plaster in CM (1:4) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement on roof surfaces complete all as specified and directed by Engr-in-Charge. Notes : WPC shall be measured and paid seperately
M&L APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) with 15 cm longitudinal & horizontal over lapping and joints finally pasted with thermo- fused withblow lamp laid over a coat bitumen @ 1.20 Kg /Sqm over bituminous primer 0.30 ltr per sqm as per APP manufacturer instructions etc complete all as specified and as directed
M&L two coat of aluminium paint over top surface of water proofing membrane etc complete all as specified and as directed
S & F in repairs 6mm Non asbestos fibre cement building boards fixed to walls or laid/ inserted to timber/GI/Aluminium framework with screws
M&L for applying evenly 3 coats of elastomeric liquid applied membrane of Home Shield PU roofkoat of Berger or equalvent as approved by Engrineer-In-Charge as in Roof portion where leakage and seepage are noticed and as directed by approved applicater. Note :- Authorised applicater is approved by GE.
Material and labour for taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning/washing of cooling coil, air filters/plasma filters etc of Indoor unit & condenser, compressors, fan motor etc of Out door unit with vacuum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc and changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition complete all as specified and directed by Engineer-in-Charge. Note :- (i) Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of new spares shall deemed to be included in unit rate quoted. (ii) Penalty will be charged for not attending complaint from 6 hours to 12 hours Rs. 250/- and from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency at risk and cost of the contractor.
Supply only following spare parts of Split AC unit of Cap 1.5 Ton/ 2 Ton :-
Running capacitor 36 MFD Make : Bentex/Delcon
Running capacitor 45 MFD Make :- Bentex/Delcon
Starting capacitor 100-120 MFD Make:- Bentex/Delcon.
Starting capacitor 120-150 MFD Make :- Bentex/Delcon.
Starting Relay 1022/ 1622 Make :- Renutral/ Epcos/Asian
Starting Relay 2000 Make :- Renutral/Epcos/Asian
Overload Relay Make :- Renutral/Epcos/Asian
Thermostat switch 2059/2064/2054 Make :- Indfass/Danfoss
Condenser fan blade for spilt Type A.C Cap 2/1.5 Ton
Wiring kit for A.C split Type 1.5/2 TR
Remote control for split AC Cap 1.5/2 TR of make as per site requirement directed by Engr-in-Charge.
Supply & fixing in repairs main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2 TR as directed by Engr-in-Charge.
S & F in replacement suction and discharge valve set for Split AC 1.5/2 TR capacity of make as per exisiting at site as directed by Engr-in-Charge.
Replacement of un/sv PCBs from existing split type AC of 1.5/2TR capacity, and re-fixing with new proper functioning of the AC complete all as specified and directed.
M&L for disconnecting from mains and taking out existing unserviceable sealed compressor unit from the split type Air Conditioner of Cap 1.5 Ton, of any model/make/type from any location and Supply , Installing and testing (in repairs) existing company made new sealed compressors with one year warantee including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc including Charging of Gas R-22 and commisioning complete all as specified & directed by Engg-in-Charge Make :- Kirloskar/Voltas/Blue star
Description all as per item No. 03 above but spilt type Air Conditioner of Cap. 2 Ton. Make :- Kirloskar/Voltas/Blue star
Disconnecting from mains and Taking out unserviceable fan motor/blower motor of split type AC 1.5/2 ton capacity of any make and type from any location and supply, installing and testing new motor of 1/4 HP or 1/2HP, 920 RPM, 230 Volts or as per existing capacity and model complete all as specified & directed by Engr-in-Charge. Make : AUE/Crompton Greaves/Speed King/Cool Master Note :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted.
Material and labour for disconnecting from mains and taking out unserviceable condenser cooper coil of split Type AC of Cap. 1.5 Ton/2 Ton of any make and type from any location and supply, installing and testing in repairs new condneser coil as per existing capacity and make complete all as specified and directed by Engr-in-Charge. Make - Voltas/Carrier/LG.
S & F in repairs evaporator/cooling coil ofsplit type AC of capacity 1.5 TR /2 TR of existing make and size as specified and directed by Engr-in- Charge.
Material and labour for taking down unserviceable outdoor unit of split AC of any make type any capacity & supply & fixing new outdoor unit suitable for 1.5/2TR capacity complete all as directed by Engr-in-Charge. Make : LG/Voltas/Hitachi.
Taking down unserviceable indoor unit of split AC of any make type and capacity & supply & fixing new indoor unit suitable for 1.5/2TR capacity complete all as directed by Engr-in-Charge. Make LG//Voltas/Camipro/Godrej
Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipe refrigerant tubing 1/4" for suction /discharge including insulation tubing 1/4" complete including brazing, welding, with bolts and screws of reqd size complete all as directed by Engr-in-Charge
Taking down unserviceable copper pipe of size 1/2" and supply & fixing new copper pipe refrigerant tubing 1/2" for suction/discharge including insulation tubing 1/2"complete including brazing, welding, with bolts and screws of reqd size complete all as directed by Engr-in-Charge
Material and labour for taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC all as specified and directed by Engineer-in-charge.
Material & labour for detecting the leakages of gas of split type AC of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or charging of refrigerant gas R-22/R-134A in window type /Split Type AC unit of capacity 1.5/2TR including testing and commissioning complete in satisfactory working condition.by any other means and making it fully functional as specified and directed by Engr-in-Charge. Note: qty of refrigerant gas R-22/R-134A in window type /Split Type AC shall be measured separately.
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 2.0 TR all as specified as directed by Engineer in-charge.
Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20-32 Amps including taking down old/unsv Metal clad socket of approved make as directed by Engr-in-Charge.
Supply and fix MCB single pole, 240 volts, 5 to 40 Amps 10 KA complete including taking old unservicable MCBs of any type/capacity all as specified and as directed by Engr-in-Charge.
Supply & Fixing in replacement Metal clad Plug ISI Marked. Make :- C&S/Legrand/Havells.
Supply & Fixing in replacement Metal clad Socket ISI Marked. Make :- C&S/Legrand/Havells.
M&L for shifting of split AC 1.5/2.00 TR includng dismantiling all accessories, indoor outdoor unit and copper insulation, voltage stabiliser and rienstalling the all acessories at new location as directed the coat of new copper pipe suction and discharge including insulation and electric cable 3 core , 4 Sqmm as per site requirement in included in the quoted rate complete all as specified and as directed at site by Engineer in charge.
M&L for 3 core flexible PVC ensulated cord sheathed 4.00 Sqmm including connection all as directed
Material and labour for taking down for servicing unserviceable voltage stabilizer of capacity 4 to 5 KVA from the site and transporting to contractors workshop for locating the fault including checking the servicibility of electrical/electronic circuits relays and repalcement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to site complete all as specified and directed by Engr-in-charge Note :- 1. Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.
Supply only following defective spare parts of Voltage stabilizer of Cap 4 to 5 KVA :-
Voltmeter (Anlog) 0 to 300 volts any type shape single phase 50 Hz AC supply Make AE, MIECO, Rishabh
Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply Make AE, MIECO, Rishabh
Printer circuit control card suitable for 4 to 5 KVA
Input/output switch Make AE/Rishabh/Mico
Push on switch Make AE/Rishabh/Mico
Indicator complete with bulbs Make Renutrol/Technomac
Trigger Transformer for 4 to 5 KVA
Relay for4 to 5 KVA voltage stablizer Make Renutral /Technomac
Time delay and High/low voltage cut off circuit with relay suitable for 4 KVA to 5 KVA Make Renutorl/Technomac
Material and labour for taking out the burnt winding of transformer of voltage stablizer and prepairing core after cleaning by suitable cleaning agent and rewinding the transofrmer of voltage stablizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 4 KVA voltage stablizer, complete all as specifies & directed by Engr-in-Charge.
Desctription all as per item No 155 above but 5 KVA
Dismanling and removing defective compressor and replacing the same with new sealed compressor of approved make obtained from authorised dealers for 180 Ltrs capacity refrigerators all as specified and directed.
Dismanling and removing defective compressor and replacing the same with new sealed compressor of approved make obtained from authorised dealers for 300/310 Ltrs capacity refrigerators all as specified and directed.
Dismanling and removing defective compressor and replacing the same with new sealed compressor of approved make obtained from authorised dealers for water cooler of 40/80 Ltr capacity all as specified and directed.
Dismanling and removing defective compressor and replacing the same with new sealed compressor of approved make obtained from authorised dealers for water cooler of 60/120 Ltr capacity all as specified and directed.
Dismanling and removing defective compressor and replacing the same with new sealed compressor of approved make obtained from authorised dealers for water cooler of 150 Ltr capacity all as specified and directed.
Note :- FOR ITEM No. 157 to 161 here as above :-
(i) Warranty certificate from manufacturer/authorised dealers shall be submitted alongwith compressor unit.
(ii) Supply and charging of gas will be measured and paid separately under relevant item.
Supply and charging refrigerant gas non CFC based compatible to F-22/134 in refrigerators of capacity 180/300/310 Ltrs capacity including cutting and brazing of copper tubes complete all as specified and directed.
Supply and charging refrigerant gas non CFC based compatible to F-22/134 in water coolers of capacity 40/80 Ltrs capacity including cutting and brazing of copper tubes complete all as specified and directed.
Supply and charging refrigerant gas non CFC based compatible to F-22/134 in water coolers of capacity from 60/120 Ltrs to 150/150 Ltrs capacity including cutting and brazing of copper tubes complete all as specified and directed.
Note :- FOR ITEM No. 165 to 167 here as above
Supply and fix in replacement capillary tube of existing size including necessary brazing suitable for 180/315 Ltrs capacity refrigerator, including dismantling the old unserviceable one all as specified and directed.
Supply and fix in replacement over load protector relay suitable for 180/300/310 Ltrs capacity refrigerator all as directed.
Supply and fix in replacement thermostat suitable for 180/300/310 Ltrs capacity refrigerators all as directed.
Supply and fix inreplacement over load protector relay suitabble for 40/80 Ltrs capacity water cooler all as directed.
Supply and fix in replacement thermostat suitable for 40/80/120/150 Ltr capacity water coolers all as directed.
Supply and fix inreplacement condensor motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers all as directed.
Supply and fix in replacement new condensor motor 1/32 HP with fan blades complete suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and directed.
Supply and fix in replacement PVC drain pipe 25mm dia with suitable standard clip complete to fix with water cooler of any capacity including dismantling the old unserviceable one all as directed.
Supply and fix in replacement PVC connecting pipe 20mm dia and 1.5 Mtr length for inlet to water cooler with both side threaded socketed type complete all as specified and directed.
Supply and fix in replacement drain water tray complete suitable for 40/80/120/150 Ltr capacity water coolers all as directed.
Supply and fix in replacement chromium plated bib cock push type outer/inner threaded suitable for 40/80/120/150 Ltr capacity water coolers all as directed.
Supply and fix in repairs PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size all as directed.
Supply and fix in repairs freezer door with spring of refregierators of any capacity & make all as specified and directed.
Supply and fixing in replacement vegetable basket with glass suitable for 180/300/310 Ltrs capacity refrigerators.
Supply and fixing in replacement PVC defrost tray as per sample suitable of 180/300/310 Ltrs capacity refrigerators.
Supply and fixing in replacement door gasket for refrigerators of capacity upto 180 to 310 Ltrs complete all as specified and directed.
Dismantling of existing repairable deep freezers of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop fro carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note :- Parts renewed shall be measured and paid separately under appropriate items.
Supply only starting relay upto 300/320 Ltrs capacity deep freezer all as specified and directed.
Supply only over load protector suitable for upto 300 Ltrs capacity deep freezer all as specified and directed.
Supply only running capacitor for upto 300/320 Ltrs capacity deep freezer all as specified.
Supply only thermostat suitable for upto 300/320 Ltrs capacity deep freezer all as specified and directed.
Supply only starting capacitor for upto 300/320 Ltrs capacity deep freezer all as specified and directed.
Taking down defective compressor of capacity300/320 deep freezer of any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all as specified and directed by Engineer-in-Charge.
M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed. Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P. (ii) The items required to be replaced shall be measured and paid separately under relevant items.
Supply only wood wool pad of suitable size for 24” sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pad As per sample
All as per item No 57 above but 20” sweep approximate weight 700 -800 Gms. As per sample
supply only submersible pump (tullu pump) motor 230 Volts , single phase, AC. Make- Little/ Crompton/ Khaitan.
"S & F in replacement of New fan motor with cooper winding including suitable fan blade of existing capacity and size for desert coolers complete all as specified and as directed. Make : Crompton Greaves/Usha/Khaitan
supply only PVC front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicating lamp all as specified and directed (As per Sample).
Supply & fixing wire mesh for desert cooler pad (Set of Three).
Supply & fixing PVC pipe for connecting pump and water distributor of size 15 mm dia. As per sample
Supply & fixing PVC elbow for desert cooler. As per sample
Supply & fixing PVC 4 Way distribution cross for desert cooler. As per sample
M&L for flexible copper conductor cable PVC insulated & PVC sheathed of size 14/.0076 complete all as specified and directed. ( Make - Plaza/Kalinga)
S&F in replacement desert coolers fan blade of 18" (inch) sweep make out of Plastic/Aluminum complete all as specified.
S&F in replacement desert coolers fan blade of 20" (inch) sweep make out of Plastic/Aluminum complete all as specified.
Supply and fixing in repairs side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement switch piano flush type single pole one way 5Amp 230 V for desert cooler all as directed (Make-Anchor/Kingal/Havells)
S&F replacement 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells)
S&F in replacement desert cooler body of size 26 inch x 26 inch x 32 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch 5 Amp piano switch and depth of water tank not less than 7" (inch) complete all as per sample.
M&L for evacuation of Gas from the system feeding the dry nitrogen by separating the low and high side of the system and leak testing the same arresting the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves of compressors, gland packages of all angle valves flaring of all connections framing welding angle valves flaring of all connections framing welding etc complete including gas charging of Central Type AC plant of capacity 3X35 TR & 3X 7.5 TR pacakage AC unit complete all as specified and as directed.
Supply and charging refrigerant R-22 Gas of approved make in new sealed cylinder complete all as specified and as directed.
Supply and filling for top-up of compressor oil N-68 complete all as specified and as direcetd. Make: SERVO/Seetal
Repair/maintenance/servicing complete unit of AHU’s of AC plant 3*35TR Capacity system and cleaning of metallic filters and cooling coils, with cleaning agent followed with pressurized water jet at NTS central type plant including repair to nozzle and spraying pipe , clamps and tie rod replacement , cleaning at FRB shuts and fixing HW FRP cover to air motor complete all as specified and as direcetd.
All as per item No 212 above but for AC plant 2x7.5 TR +1x7.5 at EMI/EMC lab complete all as specified and as direcetd.
Dismantling the existing water cooled condenser of Cap 35 TR of shell and tube type from its pipe line and gas connection repairing the same by replacing the defective copper tubes by new one with existing size and dia, Cleaning the shell complete assembly the new and serviceable tubes charging testing for 350 PSI pressure all as specified by Engineer-in-Charge Note :- Rate mentioned included copper tubes.
S&F in replacement of thermostatic expansion valve of suitable for existing AC Plant 3&35 TR including cutting, welding, brazing, replacement nut bolt, washer of existing make etc all as specified & directed by Engineer-in-Charge, Note for Item :- Before disconnecting the existing expansion valve from the system the refrigerant has to be pump down or taken in empty cylinder by help of ICE etc.
S&F in replacement of temeperature gauges of the chiller and condenser lines operates by mercury liquid of range 0-50⁰C Make:Fiebig.
S&F in replacement of pressure gauges of the chiller and condenser lines of range 0 - 250 Psi. Make:Fiebig.
M&L for repalcement of worn bearing No. 6308 for compresser motor 40 HP including replacement of coupling plate, bush nuts bolts complete accessories for smooth functioning and testing complete all as specified and as direcetd.
M&L for repair to control panel of 3&35 TR AC Plant with replacement of contractor , relay timer switch starting switch complete wiring of panel and connection, Replacement of imported controls pressure, switches gauges, modulating valves, modulating motors, microprocessor and BMS components of compressor unit 1 to 3 at NTS complete all as specified and as direcetd.
M&L for repair to control panel of 3x 7.5 TR with replacement of contractor , relay timer switch starting switch complete wiring of panel and connection, Replacement of imported controls pressure, switches gauges, modulating valves, modulating motors, microprocessor and BMS components of compressor unit 1 to 3 at NTS complete all as specified and as direcetd.
Supply and fix in replacmenet butterfly valves suitable for GI pipe complete including dismantling the old and nuts , bolts and socket size 100 mm as per site replacmeent and all as directed of Engineer-in-Charge
M&L for rewinding of Induction Electric Motor upto 10 HP Capacity of any Make and size complete with super enameled copper wire of existing gauge including Varnishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
M&L for rewinding of Induction Electric Motor upto 15 HP Capacity of any Make and size complete with super enameled copper wire of existing gauge including Varnishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
&L for rewinding of compressor Electric Motor upto 50 HP Capacity of any Make and size complete with super enameled copper wire of existing gauge including Varnishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
M/L for repairing the cooling tower of AC Plant 3x35 TR Capacity istalled at NTS by Strip opening of the parts such as CT fan motor, fan, fan blades, PVC fins, sprinkler, tie rod ,eliminator, electric connection complete , and removing silt deposited inner part of the cooling tower by wire brush, PVC branch pipe and applying solvent as applicable and refixing the same after repairs/modification etc all as specified and as directed at site by Engineer in charge.
M/L for repairing the cooling tower of AC Plant 3x7.5 TR at EMI/EMC lab by Strip opening of the parts such as CT fan motor, fan, fan blades, PVC fins, sprinkler, tie rod ,eliminator, electric connection complete and removing silt deposited inner part of the cooling tower by wire brush, PVC branch pipe and applying solvent as applicable and refixing the same after repairs/modification etc all as specified and as directed at site by Engineer in charge.
Supply and fix in repalcement of old/damage casing with new casing of existing material and size suitable for compressor of central Ac pant Reciprocating Chiller with (WCUR035OS) open type compressor -05040 – Flange to Flange of capacity (3x 35 TR ) Make: VOLTAS installed at NTS applicable and refixing the same after replacement& testing complete with standard warranty etc all as specified and as directed at site by Engineer in charge.
J.P. Enterprises
M/s Birja Nand
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .