Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.3 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹21.1 L+₹2.9 L (15.6%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹22.9 L+₹4.6 L (25.1%)Rejected-Finance 422 MAIN BRANCH MASTER TARA SINGH NAGAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹25.0 L+₹6.7 L (36.7%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹25.5 L+₹7.2 L (39.6%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR AND MAINT OF SERVO VOLTAGE STABLIZERS, ACBs AND CONNECTED ITEMS UNDER GE(AF) (TA) AGRA
2021_MES_418310_1
8200-1291/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹50,000
Yes
27 Mar 2021
3 Feb 2021
25 Feb 2021
3 Feb 2021
23 Feb 2021
11 Feb 2021
3 Feb 2021 - 6 Feb 2021
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m in depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed
Returning & filling including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified and directed.
Supply & laying of best quality of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat in trenches over the cable prependicular to the axis of cable complete all as specified and directed.
M&L for sand coushioning with local , dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as specified directed. Note :- Depth of sand shall be measured and paid after punning .
Taking out old serviceable/unserviceable LT UG cables of size 95 to 240 Sqmm 3.5 Core from trenches, poles/walls and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and directed
Supply and Laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and directed :-
(a) 95 Sq mm 3.5 core
(b) 120 Sq mm 3.5 core
(c) 240 Sq mm 3.5 core
Supply and fixing in replacement of MS Chequered plate of 5 mm thick or over in thickness , of Fe - 290 Gde E165 and fixed in substation building including making provision for lifting the plate from duct complete all as specified and directed.
M&L for disconnecting incoming and all outgoing electric connection of servo voltage stabilizer of any capicity,opening from top and taking out U/S parts and taking out transformer oil and repouring after repair of stabilizer Note :- (i) Spare parts required for replacement shall be measured and paid saperately under respective item of BOQ as supply only. (ii) No extra payment given in this account if other item required for serviceability of stabilizer. (iii) Testing, commissioning of stabilizer included in rate quoted by contractor.
(a) Supply only push button switch
(b) Supply only auto manual switch
(c) Supply only DPDT switch
(d) Supply only micro switch
(e) Supply only set of panel lamp
(f) Supply only potentiometer
(g) Supply only voltmeter (Digital/Analog)
(h) Supply only amp meter with C.T. (Digital/Analog)
(i) Supply only electronic circuit card (P.C.B)
(j) Supply only micro processor based control card for each phase
(k) Supply only P.C.B. holder
(l) Supply only trigger Transformer
(m) Supply only rotary Switch 5 Amp for RYB Phases
(n) Supply only servo motor 3 K.G torque
(o) Supply only servo motor 10 K.G torque
(p) Supply only R.C. network for 3KG motor
(q) Supply only R.C. network for 10KG motor
(r) Supply only carbon Brush
(s) Supply only service charges upto 150 KVA per unit
Supply, Installation and commissioning in replacement of control unit with air circuit breaker ACB, 415 Volts, 50 Hz, 4 pole, 1250 Amps current carrying capacity micro processor and comprising the following:- (i) Withdraw able version ACB 415 Volts, 4 pole, 1250 Amps, 50kA breaking capacity. Make: C&S Model No WX12N4P*A (S) or equivalent in specified makes. (ii) Indipendent manual spring closing mechanism - 01. (iii) Shunt opening closing release-01. (iv) Kiosk box / enclosure shall deemed to be included unit rate. (v) Racking in and out handle. (vi) CT 600/5 one set. (vii) Safety shutter.
Supply, Installation and commissioning in replacement of control unit with air circuit breaker ACB, 415 Volts, 50 Hz, 4 pole, 1000 Amps current carrying capacity micro processor and comprising the following:- (i) Withdraw able version ACB 415 Volts, 4 pole, 1000 Amps, 50kA breaking capacity Make: C&S Model No WX10N4P*A (S) or equivalent in specified makes. (ii) Indipendent manual spring closing mechanism - 01. (iii) Shunt opening closing release-01. (iv) Kiosk box / enclosure shall deemed to be included unit rate. (v) Racking in and out handle. (vi) CT 600/5 one set. (vii) Safety shutter.
Supply, Installation and commissioning in replacement of control unit with air circuit breaker ACB, 415 Volts, 50 Hz, 4 pole, 800 Amps current carrying capacity micro processor and comprising the following :- (i) Withdraw able version ACB 415 Volts, 4 pole, 800 Amps, 50kA breaking capacity Make: C&S Model No WX08N4P*A (S) or equivalent in specified makes. (ii) Indipendent manual spring closing mechanism - 01. (iii) Shunt opening closing release-01. (iv) Kiosk box / enclosure shall deemed to be included unit rate (v) Racking in and out handle (vi) CT 600/5 one set (vii) Safety shutter.
Supply, Installation and commissioning in replacement of control unit with air circuit breaker ACB, 415 Volts, 50 Hz, 4 pole, 630 Amps current carrying capacity micro processor and comprising the following :- (i) Withdraw able version ACB 415 Volts, 4 pole, 630 Amps, 50kA breaking capacity Make: C&S Model No WX06N4P*A (S) or equivalent in specified makes. (ii) Indipendent manual spring closing mechanism - 01. (iii) Shunt opening closing release-01. (iv) Kiosk box / enclosure shall deemed to be included unit rate (v) Racking in and out handle (vi) CT 600/5 one set (vii) Safety shutter.
M&L for dismantling the cable connection of four pole ACB of capacity upto 1250 Amp, 415V 50Hz of as per existing make, strip opening the ACB, inspecting the parts for serviceability/ overhauling complete and carrying out the following repairs/ maintenance:- (a) Cleaning the insulation parts including bushing with CTC solution. (b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer’s instructional manual. (c) check the bolts, nuts washer, cotter pins and all terminal connections are in place and tightening and replacement of the worn out parts. (d) check arc chutes for damage. (e) Clean and lubricate the operating mechanism with non-hardening grease for the wearing surface, Adjust breaker operating mechanism all as per manufacturer’s instructional manual. (f) Checking/ inspecting shunt trip coil for serviceability and replacing the same if required. (g) checking control device free for operation. (h) check after servicing the circuit breaker to verify the contacts move to fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/ bolts/ washers/ pins etc. Major spares like shunt release and trip coil etc will be measured & paid separately under relevant schedule items.
Supply only auxiliary contact block suitable for ACB of 630 A to 1250 Amps as all per existing make
Supply only arcing contact (fixed/moving) suitable for ACB of 630 A to 1250 Amps as all per existing make
Supply only arc chutes (for 415 V) suitable for ACB of 630 A to 1250 Amps as all per existing make
Supply only shunt release (241/415V AC) or suitable for ACB of 630 A to 1250 Amps as all per existing make
Supply only cluster contact suitable for ACB of 630 A to 1250 Amps as all per existing make
Supply only trip coil or suitable for ACB of 630 A to 1250 Amps as all per existing make
Servicing of LT indoor cubical panel, to check the main incoming LT, MCCB , and replace the unserviceable parts and ensure the performance of panel, check the incoming and outgoing MCCBs terminals and replace burnt thimples with new, ensure that there is no loose connection in panel, including taking out cable from tenches/loop and reconnect as existing and marking locations of out going feeder complete all as specified and as directed.
Servicing of feeder pillar box any type including MCCBs, busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter and fixing proper hanging front and rear openings, replace burnt thimbles with new all as existing size, providing cable glands including taking out cable and reconnect as existing and marking locations of out going feeder complete all as specified and directed.
S&F in repair MCCBs of capacity 250 Amps, 25 KA, 4 pole, 415 volts thermal magnetic release complete all as specified and directed.
S&F in repair MCCBs of capacity 160 Amps, 16 KA, 4 pole, 415 volts thermal magnetic release complete all as specified and directed.
Supply and Fixing in replacement of RYB indicator lamp LED type (set of three lamp) for incoming and outgoing supply as per existing size complete all as specified and directed.
M&L two coats of synthetic enemal paint on feeder pillar LT cable panel box including prepration of old existing steel surface of complete outside and inside with complete all as specified and directed.
AUTOMATION AND SWITCHGEAR PANELS
HARI CONSTRUCTION CO.
GUPTA ENGINEERING WORKS
Balaji Associate
garg construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .