Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.7 L+₹4.0 L (13.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹35.8 L+₹6.0 L (20.3%)Rejected-AOC 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-AOC L3 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
Kanjoli line Bharatpur
Provn of certain sanction work Part-II at RMS Dholpur under GE Bharatpur
2022_MES_545587_1
8189/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹66,000
Yes
24 Sept 2022
16 Aug 2022
20 Sept 2022
16 Aug 2022
13 Sept 2022
30 Aug 2022
17 Aug 2022 - 25 Aug 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc.
Dismantlingof old U/S rusted main switch/DB of any size capacity and make.
Dismantling of old U/S sub main wiring and service wire of any size & make.
M&L PVC conduit point wiring for classroom and adm offices with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipes with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed inside the wall/ceiling by means of PVC conduit pipes and making good of distrub surface cement mortar /cemant based putti including making same colour as existing and suitable accessories including suitable size of PVC boards/existing sunken box with Hylem board for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete.the size of conduit pipe for wiring will be as per direction givin by engineer-in -charge and all as specified and directed for the following :- One light point controlled by one way switch.
One ceiling fan/exhaust fan point controlled by one way switch.
One 3 pin or 5 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin or 5 pin 6 Amp socket point outlet on the independent board
All as per item No 4 above but with multi stranded copper conductor cable 4 Sqmm size for 3/5 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade Make : Anchor Penta or equivalent in Legrand
S&F switch piano flush button single pole one way 15 Amps 230 volt grade Make : Anchor Penta or equivalent in Legrand
S&F socket outlet 2 in 1, 5 pin, 5 Amp flush type multi purpose, complete all as per specified and directed.
S&F socket outlet 2 in 1, 6 pin, 15 Amp flush type multi purpose, complete all as per specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board make : Anchor penta or equivelent in Legrand.
S&F step type electronic fan regulator EME type 450 watt make : Anchor code No 50440 penta or equivelent in Legrand.
M&L submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4.0 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc.
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 2.5 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc.
M&L submain wiring complete with 10 Sqmm 2 core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc.
M&L for cutting wall and flushing in TPN DB 4 way factory made and OK tested made of sheet metal enclosure powder coated suitable for mounting MCB TPN 4way, 415V, with 200Amps rateded bus bar, double door type, including making good the wall as per existing position after ceneting/plastering/applying putty and distembering etc all as specified and as directed by Engineer-in-Charge. Make L&T/Legrand
M&L for cutting wall and flushing in Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of 12 way SPN with200 Amp rated busbar 240 volts (double door type) Make -L & T / Legrand.
M&L for cutting wall and flushing in Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of 8 way SPN with200 Amp rated busbar 240 volts (double door type) Make -L & T / Legrand.
18 S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. Make : L&T/ Legrand. MCB SP 240 volts 10-32 Amps , 10KA
MCB SPN 240 volts, 40 Amps, 10KA
MCB TPN 415V, 63Amps, 10KA
Taking down and refixing LED lights 20 watt all as specified and directed by engineer-in-charge
Supply and fixing in replacement of 20 watt LED tubelight fitting retro fit type 4 feet long with and including replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed. make: Cromption or equivelent in Phillips/Surya/Helonix/Havells
M&L batten/angle holder insulated with back plate including suitable size of PVC round block make Anchor code No 51205 complete all as specified and directed by Engineer-in-Charge.
S&F LED bulb 14W cool day light , in-built voltage surge protection > 3.5kV, single ph, 230V, luminous efficacy 100Lm/Watt, base B22, min 3 star rated all as specified and as directed by Engineer-in-Charge. Make - CG or equivalent in Phillips/Havells.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised GI strip of size 25 x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
S&L pipe galvanised medium grade complete including fittings sizes of 40mm dia all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid inside the existing pipes or fixed on pole/wall with GI clamps and clips of the following sizes:- 10 Sqmm 2 core
35 Sqmm 3 1/2 core
S&F exhaust fan 300mm sweep dia, turbo force SP, 1400 RPM, single phase, 230V with complete accessories including cutting/pinning/demolition of any type of wall upto the required size of exhaust fan, make good the wall after fixing the exhaust fan as per existing position including plastering, applying putty and wall painting/distembering etc and making provision of wire mesh for the protection of interior area from insects/monkeys or any ruptiles including taking down of old exhaust fan etc. all as specified and as directed by Engineer-in-Charge. make -Havells
S&F recess mount light fittings of SMD LED high bright lights of size 595mm x 595mm x 70mm (2ft x 2ft) square fixure with opel diffuser, slim, compact, aluminium die cast material with LED driver with complete acceesories suitable to fit in false ceiling board accurateley all as specified ans as directed by Engineer-in-Charge. make: Havells, cat Part No PLUTONEO2x2PLR28WLED840S or equivalent in CG/Bajaj/Phillips.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying HT/LT UG cable, Fibre Optic Cable etc and getting out in soft disintegrated rock complete all specified/directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply & laying unburnt locally available bricks class B for Cable protection suitable for LT UG cable of standard size all as specified and directed by Engr-in-Charge
M &L local river sand for bedding ang sand cushioning of all LT UG cable all as specified and directed by Engr-in-Charge
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having diffirent busbar chamber for both outgoing MCCB with insulated AL bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings :- Incoming (a) MCCB 4 pole- 160 Amps 25 ka with adjustiable type - 01 Nos. (b) Bus bar Al TPN 300 Amps - 01set. Outgoing (a) MCCB TPN- 63 AMP 25KA with adjustiable type -02 no (b) MCCB TPN- 100 AMP 25KA with adjustiable type -02 nos
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers including all as specified and directed by engineer-in-charge
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC),condensor and including wireless remote & connection wire all as specified and directed by engineer-in-charge
M&L for cutting hole in stone wall as per the size of exhaust fan of size 300/450 mm dia and making good with plaster 1:3 and ditumbering/paint all as specified and directed
Surjit and Sons
Allied Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .