| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82,620Accepted-Finance | ₹82,620 | L1 | Accepted-Finance Being L1 |
| 2 | L2₹1.1 L+₹22,430 (27.1%)Accepted-Finance | ₹1.1 L+₹22,430 (27.1%) | L2 | Accepted-Finance Being L2 |
| 3 | L3₹1.1 L+₹27,290 (33.0%)Accepted-Finance | ₹1.1 L+₹27,290 (33.0%) | L3 | Accepted-Finance Being L3 |
| 4 | L4₹1.1 L+₹31,220 (37.8%)Accepted-Finance | ₹1.1 L+₹31,220 (37.8%) | L4 | Accepted-Finance Being L4 |
Tender Value
₹1.1 L
EMD Value
₹2,246
Closing Date
28 Nov 2023, 3:00 pmClosed
Executive Engineer
CD APWD Kamorta
Providing solid waste management under Swatch Bharat Mission by construction of shed for soil waste management cluster for cleaning sweeping segregating of plastic glass organic matters etc at Kamorta Tribal Counsil SW Providing IEI
2023_APWD_12342_1
35/NIT/DB/CD/KMT/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Kamorta
Please refer tender document
5 documents required · 5 mandatory
₹0
₹2,246
28 Mar 2024
15 Nov 2023
28 Nov 2023
15 Nov 2023
28 Nov 2023
15 Nov 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group -C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit / Sub Main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required.
a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
c) 4 x 6.0 sq.mm + 2 x 6.0 sq.mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 amps ceiling rose on the existing junction box / wooden block including connection etc as required.
Installation, testing, commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring with the down rods of standard length (up to 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
a) Upto 450 mm sweep
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral sheet steel MCB distribution board 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240 /415 volts, 'C' curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole
b)Triple pole and neutral
Supplying and fixing following rating, four poles, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) 63 Amps
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 6.5 metre and upto 8.0 metre
Supplying of LED 20 Watts polycarbonate Batten/Tubelight 4-ft cool day light similar to Wipro Garnet with lamp 20 W LED 6500 K or its equivalent..
Supply of LED bulb of 9 Watts,white B22 Similar to Eveready cool day light or equivalent to ISI specification.
Supplying of Energy Saving A.C. Ceiling fan 1200 mm sweep, with all accessories .similar to Plycab Affeciente NeoEteri BLDC 5 star rated or equivalent
Providing and fixing waterproof cable looping out box made out of SMC and of size 450mm x 375 mm x 200 mm with hinged door and locking arrangement
Supplying installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with elelctrodite (Back fill compound ) as reqd for safe earth electrode and providing masonary enclusure with cover plate having locling arrangement etc as reqd.
Supply of metallic exhaust fan of size 230 mm similar to Anchor by Panasonic or its equivalent.
JAI ELECTRICALS
A Fakrudeen
Govinda Swamy Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .