Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹2.8 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹2.9 Cr+₹13.5 L (4.84%)Rejected-Finance | ₹2.9 Cr+₹13.5 L (4.84%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹3.0 Cr+₹21.1 L (7.60%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹3.0 Cr+₹21.1 L (7.60%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹3.7 Cr+₹92.0 L (33.1%)Rejected-Finance | ₹3.7 Cr+₹92.0 L (33.1%) | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | - | - | Rejected-Technical See evaluation report |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
2 Sept 2021, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
MODERNISATION OF INDUSTRIAL FACILITIES PHASE I AT AF STATION SULUR
2021_MES_459567_1
801513/E8
Open Tender
Civil Works
Item Rate
546 days
GE (AF) Sulur
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Sulur
₹3.8 L
Yes
5 Nov 2021
14 Jul 2021
3 Sept 2021
14 Jul 2021
2 Sept 2021
26 Aug 2021
14 Jul 2021 - 28 Jul 2021
Amount
SCHEDULE "A" PART-I (B/R WORKS) Dismantling plain or corrugated steel sheeting any gauge including Nainital or similar pattern in roof covering, wall cladding and similar works all as specified and as directed.
M&L Applying one coat of aluminium paint on old steel surfaces over 10 cm girth including necessary preparation of old surfaces all specified and as directed.
M & L Welding in repairs, exceeding 2.5 cm but not exceeding 5 cm in length with thickness of metal to be welded not exceeding 6 mm complete all as specified and as directed.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550Mpa as in roof covering, wall cladding, doors and similar surfaces fixed with galvanised self tapping screws, all as specified and directed'
S&F Pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of approved colour having tensile strength of 550Mpa as in ridges, hip & valley gutter and similar surfaces fixed with self tapping screws/J’ hooks all as specified and directed
M&L Mild steel flat iron wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 including applying two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and as directed.
Dismantling mild steel structural work of any description and in any position including doors, gates, etc all as specified and as directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position all as specified and directed.
All as per item No 8 but in fillets, rails, posts, rafters, purlins, etc under 40 sqcm in section
M&L Mild steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; and similar items fixed with angle cleats or other connecting plates conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L Applying two coats of aluminium paint over a coat of zinc chrome primer on new steel surfaces over 10 cm girth including necessary preparation of surfaces all specified and as directed.
M&L Applying two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer on new steel surfaces of any description over 10 cm width or girth including necessary preparation of surfaces all as specified and as directed.
Repair to existing hangar door shutter of leaf of size 6.00 M(clear width), 8.00 M (clear height) of each without taking down, straightening of worn-out top & bottom rails, replace unserviceable existing rollers, tightening/replacing the loose nut and bolts, necessary/required welding of rails with hangar structure, replacement of broken locking arrangement etc, oiling, greasing and one coat of aluminium paint to complete door structure etc for smooth functioning of hangar door shutters all as directed by Engineer in charge. Note:- Replacement of CI/MS wheelers where required will be measured and paid separately as supply only. However the unit rate quoted is deemed to inclusive of cost labour to replace the wheels.
Supply only cast iron hangar wheels 230 mm dia and 25 to 40 mm thick, weight between 18 to 25 Kg including 25 mm dia x 100 mm gun metal bushes shaft and other fixing materials for bottom rails complete for smooth functioning of hangar door shutter all as specified and as directed by Engineer in charge.
Supply only Mild steel hangar wheels 230 mm dia and 25 to 40 mm thick, weight between 10 to 22 Kg including 25 mm dia gun metal bushes, shaft and other fixing materials for top rails complete for smooth functioning of hangar door shutter all as directed by Engineer in charge.
Cleaning/greasing/oiling of hangar wheel track at top of any description, welding of members if required, tightening of screws/nuts, bolts of door and wheels etc including rectifying the alignment of top guide channel/rail/angle etc complete for smooth functioning of hangar doors complete all as specified and as directed.
Cleaning/greasing/oiling of hangar wheel track at bottom of any description, welding of members if required, tightening of screws/nuts, bolts of door and wheels etc including rectifying the alignment of bottom guide channel/rail/angle etc complete for smooth functioning of hangar doors complete all as specified and as directed.
Demolition(unreinforced) concrete of any description and in any position not otherwise specifically provided for all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth getting out in hard/dense soil complete all as specified and as directed.
M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M&L PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts drain walls and similar works complete all as specified and as directed.
M&L Pre cast cement concrete type B-1, 1:2:4 set in cement mortar 1:6 as in landings, cover slab(for manholes etc), chulla hood, chajjas, water troughs, mangers, shelves and similar articles including necessary form work complete all as specified and as directed.
S&F TMT bars 10 mm dia and over, cut to length, bent to shape, required including cranking, bending spirally for hooping end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Construction of Soakage well 1.20 mtr dia 3 mtr depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed. Note:- Refer Drawing No.AFB/TD/125, Sheet 1/2 & 2/2 given list of drawing on serial page No.196(R) of tender documents
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and as directed.
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses,etc.; vertical or to batter fair finished surfaces complete all as specified and as directed.
S&F Mild steel Plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) of Fe 410-W(Gde-E 250) complete all as specified and as directed.
S&F Mild steel Joist, channel, angle or tee sections, fixed independently without connecting plates etc of Fe 410-W(Gde-E 250) complete all as specified and as directed.
Returning filling in, including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
S&F Wind operated Turbo Ventilators of size 24 inches dia of High grade Industrial Aluminium of thickness not less then 0.5mm, Hardware of stainless steel -304. Bearing shall be of steel in completely enclosed and dustproof integrated housing and aligned with each other, and shall have capability to rotate at nearly zero wind speed. Turbo ventilator shall have UV stabilized powder coated and capable of static balancing with high exhaust capacity and there shall not be any exhaust problem due to air back draft. Fixing arrangement shall have high quality rubberized hardware to prevent rain Ingress All Turbo Ventilators shall be installed by Manufacturer’s Authorised Representative only. Contractor shall give no leakage guaranty for period of three years from the date of installation of Turbo Ventilator all as specified and directed. Make : M/S Turbo Ventilators/ M/S SVS Wind Driven Turbo Ventilators/ M/s Arven Turbo Ventilators
Supply and fix Anti Bird Net UV black in colour fixed in Entrance door pulley based side openable made of material Polyolefin all weather proof co-polymer of machine knotting using CNC machines with DSLS technology for anti slip knotting, heat setting should be steam set for greater dimensional stability and knot firmness and diameter of the twine 1mm and the size of mesh 25x25mm(+/-2mm) of square mesh and should achieve twine breaking strength of 16 kgf min, MBS (Mesh breaking strength) 12 Kgf and KBS (Knot Breaking strength) 22 Kgf min fixed complete all as manufacturer's instructions complete all as specified and as directed. Make:M/s Leo Techonova India/M/S Srijan Pvt Ltd).
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Supply and fix Anodised aluminium snap grid of size 605x605mm frame work for false ceiling complete all as specified and as directed.
Material and labour for Providing and fixing Gypsum Board 12mm thick in false ceiling fixed with screw as per manufacturers instructions
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises (out of MD land) complete all as specified and as directed.
M&L Non - skid coloured Ceramic tiles joint free 7 to 8 mm thick (square/ rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finish, over 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as levelling course all as specified and as directed. Note: The unit rate quoted against the item is deemed to include for provn 15mm thick screed bed and 25mm thick PCC as specified .
M&L Glazed ceramic tiles, coloured, of size 450 x 300mm, 7mm thick, as in dado/ skirting/ risers of steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in cement mortar 1:4, all as specified and as directed.
M&L Vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6, all as specified and as directed.
M&L Vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in skirting, dodo etc and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in cement mortar 1:4, all as specified and as directed.
Taking down chowkats or frames of area not exceeding 1.5sqm each with shutters (without taking off shutters from the frames) all as specified and as directed.
Taking down old Chowkhats or frames area exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down old Chowkhats or frames area exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frames) and refixing in same in opening all as directed.
Supply and fix Aluminium door FRAME of size (section No.20047) 63.5X38.1X1.53mm weighing 0.942kg/m, SHUTTER frame vertical member (section No.19569) of size 47.62X44.45X2.02mm weighing 1.059kg/m, shutter top horizontal frame (section No.19528) of size 47.62X10.16X1.74mm weighing 0..881kg/m, shutter bottom horizontal frame (section No.19529) of size 47.62X95.25X1.70mm weighing 1.301kg/m, with powder coating of min thickness 50 micron, 5mm thick Colour tinted glass at top, 12mm thick pre-laminated particle board at bottom, including decorative aluminium handles, hinges, glazing clips, rubber neoprene packing, snap beading screws, Mortice lock, hydraulic door closer, door stopper etc complete all as specified and as directed.
S&F Aluminum two track sliding windows FRAME top & sides (section No.21138) of size 62X29.5X1.5mm weighing 0.807kg/m, frame bottom (section No.21139) of size 62X29.5X1.5mm weighing 0.902kg/m, SHUTTER plain vertical member (section No.21093) of size 39X20X2.0 weighing 0.634kg/m, shutter inter lock vertical frame (section No.21094) of size 39X20X2.0mm weighing 0.734kg/m, shutter bottom horizontal frame (section No.20551) of size 40X20X1.5mm weighing 0.484kg/m, with powder coating of min thickness 50 micron with one or more rebates, sliding type without sash bars including 5mm thick tinted glass with rubber neoprene packing, hinges, handles, snap beading screws etc complete all as specified and as directed.
S&F Aluminium louver frame (section No 20047) of size 63.50x38.10x1.53mm weighing 0.942 kg/m, 4 mm thick, pin headed glass, adjustable louvers with powder coating of min thickness 50 micron complete all as specified and as directed by Engineer. Note for serial Item No 44 ,45& 46:- The make of Aluminium shall be M/s Jindal or any other make specified in particular specification under Sl No.5 of list of manufacturer on serial page No.173 of Tender Documents
S&F Coloured venetian blinds imported quality to windows vertically hanging self designed with all fitting such as brackets, rollers, pulleys etc complete fixed in repairs all as specified and as directed.
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S Square tube supply and fix in opening complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style)consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supply and fix in the frame at site complete all as specified and as directed.
Supply and fix 4.00mm thick, sheet glass, ordinary quality, in squares exceeding 0.5 sqm each pane including hacking out old broken class of any description complete all as specified and as directed.
Supply and fix in repair Aluminium body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and as directed.
Supply and fix in repair Mortice lock, vertical type size 100mm brass 4 levers complete all as specified and as directed.
Supply and fix in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm overall length of cover plate complete all as specified and as directed.
Supply and fix in repair 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
Supply and fix in repair 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
Supply and fix in repair 100mm long butt hinges, medium weight, Stainless steel complete all as specified and as directed.
Supply and fix in repair 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:6 finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M&L Rendering 15mm thick in CM 1:4 on external plastered surfaces finished even and smooth without using extra cement, mixed with WPC as per manufactures complete all as specified and directed. (WPC shall be measured and paid separately)
M&L Preparation of new plastered surface and applying two coats of oil bound distemper over a coat of primer on walls including 3mm thick wall care putty complete all as specified and as directed.
M&L Preparation of new plastered surface and applying two coats of exterior emulsion over a coat of primer on walls complete all specified and as directed. Make:- Apex of Asian paints/Weather coat of Berger/Extra premium of Shalimar/Excel of Nerolac.
M&L Preparing old wall surfaces, plastered or unplastered including complete removal of existing treatment complete all as specified and as directed.
M&L Applying two coats of oil bound distemper over a coat of primer on walls including 3mm thick wall care putty complete all specified and as directed.
M&L Applying two coats of exterior emulsion over a coat of primer on existing walls surfaces complete all specified and as directed. Make:- Apex of Asian paints/Weather coat of Berger/Extra premium of Shalimar/Excel of Nerolac,
Supply only integral water proofing compound of approved Make.
Hacking out old broken glass(any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones including supply and fix sheet glass of 5.5 mm thick in square exceeding 0.5 sqm in each pane complete all as specified and as directed.
M&L Brick work with fly ash modular bricks in cement mortar, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed.
M&L Plain Cement Concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in kerbs, benching cills, steps, bands, copings, bed plates, etc rounded or chamfered on edge, including use of necessary form work all as specified and as directed.
Taking up or down steel tubing and connections 15mm bore, all as specified and as directed.
Taking up or down steel tubing and connections 20mm bore including fitting such as bib tap, stop cock etc complete all as specified and as directed.
Supply and fix 3 layer PP-R polypropylene random copolymer (concealed pipes 16 mm bore SDR 7.4 (PN-16)UV stabilized and antimicrobial welded having thermal stability for hot and cold water including all PP-R plain & brass threaded polypropylene random fittings fixed to walls, ceilings or in floors etc complete all as specified and as directed.
Supply and fix 3 layer PP-R polypropylene random copolymer (concealed pipes 20 mm bore SDR 7.4 (PN-16) UV stabilized and antimicrobial welded having thermal stability for hot and cold water including all PP-R plain & brass threaded polypropylene random fittings fixed to walls, ceilings or in floors etc complete all as specified and as directed.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed in 15 mm bore dia of pipe complete all as specified and as directed.
Supply & fix CP pillar cock, 15mm dia CP with capstan head screwed down high pressure screwed for iron pipe complete all as specified and as directed. Make : CAT Part . No-PRS-031 of Jaguar / CAT Part No G-2302A1 of Parryware / CAT Part No-CS201A of Cera.
S&F Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed in 15 mm bore dia of pipe complete all as specified and as directed.
Supply and fix in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, waste pipe etc (excluding flushing cistern and flush pipe) complete all as specified and as directed.
Supply and fix in repair Vitreous china urinal partition white of size 32.5 x 69 cm of Cat No 61001 of Hindware/Cat No 1810-UC of Jaguar or equivalent fixed about 40cm above floor line complete all as specified and as directed.
Supply and fix Chromium plated Urinal spreader for fixing with 15mm dia pipe complete all as specified and as directed.
Supply and fix in repairs Wash basins, Vitreous China (flat back or angle back type) size 550X400 mm including cutting for and pinning in ends of brackets all as specified.
Supply only 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed all as specified and as directed.
Supply and fix PVC connections 15mm size with PTMT nuts of length 450mm all as specified and as directed.
S&F Looking mirror 6mm thick frame less beveled edge mirror of size 600x450mm fixed with steel stud as per direction of Engineer in -charge
S&F PVC (SWR) floor trap, 75mm plain with grating including jointing with solvent cement all as specified and as directed.
S&F PVC (SWR) pipe, 75mm bore, single socketed, in any length, pressure capacity 6 Kgf/ Sqcm, with rubber ring joints, laid in trenches or in floors, all as specified and as directed.
S&F PVC (SWR) bend, 75 mm bore, any radius, all as specified and as directed.
S&F PVC (SWR) pipe, 110mm bore, single socketed, in any length, with rubber ring joints, laid in trenches or in floors, all as specified and as directed.
S&F PVC (SWR) pipe, 110mm bore, Vent cowl all as specified and as directed.
S&F Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore, all as specified and as directed
S&F Tubular towel rail 20 mm dia D type, 60 cm long, brass CP fixed in repairs complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
Supply and fix in repairs Vitreous China wash down water closet pan (pedestal Pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic WC seat cover, closed pattern with flat bottom complete all as specified and as directed.
Supply and fix in repair of vitreous China squatting pan, ‘Orissa 'pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including provision of lime concrete bedding. complete all as specified and as directed.
Supply and fix in repair PVC valveless syphonic action type 10 ltr capacity flushing cistern low level, white, with inlet ball valve, float and handle including brackets, flush pipe to pedestal pan, including all joints complete all as specified and as directed.
Supply and fix CP Hand shower (Health Faucet) with 1.00M Flexible Tube with 8mm dia wall Hook with N.R.V (Back Flow Preventer) fixed in repairs complete all as specified and as directed.
M&L Brick work with subclass fly ash modular bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:4 all as specified and directed.
M&L PCC 1:2:4 type B-1(using 20 mm graded aggregate) as in pillars, posts(including caps and bases) and similar items complete all as specified and as directed.
S&F Mild steel bolts, purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 30 cm long and dia of neck exceeding 12 and not exceeding 20 mm complete all as specified and as directed.
S&F Sink made of stainless steel 1 mm thick with washers, wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets an connecting union to pipe ,overall size 495mmx420 mm and bowl size 410 mm x 330 mm x160 mm complete all as specified and as directed.
S&F Anodised aluminium frame powder coated colour as approved by GE for doors, cubical/partitions including joining cleat for fixing, sliding mechanism etc complete all as specified and as directed.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame all as directed.
S&F 5.5mm thick colour tinted float glass and glazing with oil putty in square exceeding 0.5sqm in each pane all as directed.
SCHEDULE "A" PART-I (E/M WORKS). Taking down carefully copper/Alu point wiring (light, fan. socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting of any type , MCB's, DB's etc and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
M&L Point Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, FRLS cable and including PVC Casing Capping with accessories in wall/roof/ceiling etc including Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with white cover plate with frame etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified and as directed for the following items:- .
(a) One light point/fan/bell point controlled by one switch
(b) One 3 pin socket out 5 amp on the same board
(c) One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 105 above, but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and as directed.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, FRLS cable and including Stove enameled steel conduit with accessories in wall/roof/ceiling/hangar steel frames etc including Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with white cover plate with frame etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly complete all as specified and as directed.
(a) One light point/fan/bell point controlled by one switch
(b) One switch socket outlet 3 pin 5 Amps on independent board
S&F Modular switch 1 way 6 Amps, 1 module complete all as specified and as directed.
S&F Modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
S&F Modular switch socket outlet multipurpose 2/3 pin 6 amps, 2 module complete all as specified and as directed.
S&F Modular switch socket outlet multipurpose 2/3 pin 6/16 amps, 2 module complete all as specified and as directed.
S&F White cover plate with frame, 3 Module complete all as specified and as directed.
S&F White cover plate with frame, 6 Module complete all as specified and as directed.
S&F White cover plate with frame, 8 Module complete all as specified and as directed.
S&F Electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module complete all as specified and as directed.
S&F Ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
S&F LED midbay light beam angle 90 degree, 65 W. Make/Model : Cat No LH0985109050V6 of Wipro or equivalent make in Philips / Havells / Bajaj or as per Annexure.
S&F LED street light fitting 40 W IP 66 including GI tubing 40 mm dia light grade 1.5 mtr long bent to shape with clamps for fixing of street light. Make/Model : Cat No LR02451XXX57G1 of Wipro or equivalent in make Philips / Havells / Bajaj or as per Annexure.
S&F LED down light 30 W recess/surface mounting 2' x 2'. Make/Model : Cat No CRCO10R030HP57HE of Wipro or equivalent in make Philips / Havells / Bajaj or as per Annexure.
S&F LED tube light 4'"long 20W. Make/Model : Cat No LL20-221-xxx-AL1(Trim Neo) of Wipro or equivalent make in Philips / Havells / Bajaj or as per Annexure.
S&F Fan ceiling complete with and accessories 230 V,1200 mm sweep. BEE 5 star rated. Make/Model : Cat No ES NEO of Havells or equivalent in Philips / Havells / Bajaj or as per Annexure.
S&F Exhaust fan 250 mm sweep 230 volt square type with louvers of PVC body including necessary cutting, making holes on stone/brick walls, fixing arrangement with wooden frame of 20 mm thickness including necessary nut, bolts / screws all specified and directed. Make-Havells Cat No Ventil DX-White or equivalent in bajaj, Crompton or as per Annexure.
S&F Wall mounted fan complete with and accessories 230 V,400 mm sweep. BEE 5 star rated. Make/Model : Cat No Sameera wall Fan of Havells or equivalent in Crompton / Bajaj or as per Annexure.
Supply and fix industrial type heavy duty wall mounted fan 450 mm sweep single phase 230 volts including fixing arrangement on wall/angle all as directed by Engineer -In-Charge complete. Make/Model : Cat No Turbo Force of Havells or equivalent in Crompton / Bajaj or as per Annexure.
S&F Factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and directed
S&F Factory made powder coated distribution board SPN 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and directed
S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 AMP 415V 10KA 'C' curve complete all as specified and as directed.
S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 AMP 415V 10KA 'C' curve complete all as specified and as directed.
S&F Triple pole Neutral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified Make/Model : Legrand Cat Part No 408683 or equivalent of Schneider (Multi -9) Siemens/L&T (Hegar).
S&F MCB SPN 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified Make/Model : Legrand Cat Part No 408617 or equivalent of Schneider, Siemens/L&T.
Supply and fix single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified. Make/Model : Legrand Cat No : 408587 to 408595 or equivalent of Schneider, Siemens/L&T.
Sub main wiring in repairs for circuit complete with 4 X 10 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including 25 mm dia non metallic rigid PVC casing capping and casing accessories complete fixed surface to wall/roof/ceiling etc and including 2 X 10 sqmm single core PVC insulated, unsheathed FRLS 1100 Volts grade multi stranded copper conductor cable as earth continuity conductor and connected to common earth dolly etc and all as specified. Note: 4 runs of 10 sq mm cable along with two run of 10 sqmm cable for earth conductor and casing capping shall be measured as one length.
Sub main wiring in repairs for circuit complete with 4 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including 25 mm dia non metallic rigid PVC casing capping and casing accessories complete fixed surface to wall/roof/ceiling etc and including 2 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100 Volts grade multi stranded copper conductor cable as earth continuity conductor and connected to common earth dolly etc and all as specified. Note: 4 runs of 6 sq mm cable along with two run of 6 sqmm cable for earth conductor and casing capping shall be measured as one length.
Sub main wiring in repairs for circuit complete with 2 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable PVC Casing Capping and accessories complete fixed surface to wall/roof/ceiling etc and including 1 X 6 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc and all as specified and as directed. Note: 2 runs of 6 sq mm cable along with one run of 6 sqmm cable for earth conductor and casing capping shall be measured as one length.
Sub main wiring in repairs for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multi stranded copper conductor cable drawn through and including suitable PVC Casing Capping and accessories complete fixed surface to wall/roof/ceiling etc and including 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc and all as specified and as directed. Note: 2 runs of 4 sq mm cable along with one run of 4 sqmm cable for earth conductor and casing capping shall be measured as one length.
Supply, install, testing and commissioning of advanced day lighting system of 750 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 1.8 Mtrs Length. (a) Sunlight capture system-Sunlight collection cover - Sun light collector dome shall be transparent clear dome allows light to be collected across the sky from all direction shape shall be moulded in single piece, dome shaped, clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet UV coating thickness for raw material ,sheet shall 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256). flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45° - 150° Celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be U.ZI/m'ctUHM Site'll). (b) Light Management system light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, parties fastening mechanical polymer push buttons system. (c) Light transfer system-Extension pipes:- diameter 750 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-08%, material thickness not less than 0.4mm. protection film PE foil not UV resistant
BOQ ITEM No.136 (Contd..) (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (Ci) cladding enclosing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumferentially to slip one into another and along the vertical length for overlap jointing of not less than 25mm Pipes to be joined with aluminum reviliny and closed with aluminium tape of 50mm width and 5 microns thickness (e) Light diffuser.- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffu3er ring injection moulded ADS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal. (f) Roof Kerb - Factory made of two piece metal roof kerh entire roof kerh made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet It holds the light pipe and light collector, bottom kerb also galvalum sheet fits on to roof with complete water proof arrangement colour coated surface finished kerb lop side pointed arrow design with breaker arrangement and water proofing method Is to seal system, primary seal, by rubber sealant and secondary seal-down coming 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen, light outputs test to be done with 1 0m x1 0m x1.0m light box as per standard test procedure in lab. Make:- Sky shade Cat Part No.. SKYLP750R18 or equivalent as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage
Supply and fix 800A Sandwich type Silver Flashed, Bimetal Copper Contact, Aluminum bus way (3L+N+PE), with Original Mylar insulation from DuPont, 100% N, 40kA for 1 sec, 50% Integral Earth, Dual Housing (1.6mm thick Aluminum + 1.6mm thick Electro-galvanized steel), Paint: Epoxy electrostatic powder finish Color: ANSI 49 gray, Temp rise: 55 deg. over ambient of 40 deg Rated insulation & operating voltage 1000V Straight Length complete all as specified and as directed.
S&F Elbow suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F Flange End suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F End Feed Unit suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 630A 4P MCCB Incomer suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 400A 4P MCCB Incomer suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F End Cover suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 100 A Tap Off Box suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 100 A 4P MCCB 16KA suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 63 A Tap Off Box suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 63 A 4P MCCB,16 KA suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 32 A Tap Off Box suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F 40 A 4P, 16 KA MCCB suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F Brackets suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F Clamp Support suitable for 800A Sandwich bus bar complete all as specified and as directed.
S&F Spring Hangers suitable for 800A Sandwich bus bar complete all as specified and as directed.
Supply and lay XLPE Insulated,PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS 7098/1985 ISI marked with necessary termination lugs, glands etc all as specified and as directed for 400 sq mm 3.5 core complete all as specified and as directed.
All as per Item No.153 above, but of size 300 sq mm 3.5 core complete all as specified and as directed.
All as per Item No.153 above, but of 35 sq mm 3.5 core complete all as specified and as directed.
All as per Item No.153 above, but of size 16 sq mm 4 core complete all as specified and as directed.
All as per Item No.153 above, but of size 10 sq mm 4 core complete all as specified and as directed. Note for item No.153 to 157. (i) Excavation for laying cable, RFR and removal of soil shall be measured and paid under respective items of BOQ.
Supply and fix copper strip 20 x 3.15mm thick with saddles and fixing screws etc for roof conductors above ground all as directed.
Supply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed.
Material and labour for earthing complete with Copper earth plate electrode 600mmx600mmx3.15 mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with Copper earth strip 20mmx3mm thick and Copper bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I including necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, and provn of test point complete. NOTE :- Copper Strip 20mmx3mm upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately.
Material and labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth strip 32mmx6mm thick and GI bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I including necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, and provn of test point complete. NOTE :- GI strip 32x6mm upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately.
Supply, Install, testing, and commissioning of 11KV Extensible Load Break Switch. Outdoor type with IP-54 Fabrication (ensuring outdoor protection to complete Load Break Switch, including cable-boxes), SF6 gas insulated compact switchgear, comprising of arrangement Load Break Switch 630Amp, cable termination from front/rear side, having short-circuit withstand capacity of 20KA/3sec. permanently enclosed in a tank accommodating upto 01 -modules in single tank made by robotically sealing non-magnetic / non-ferritic SS 304 grade stainless steel sheets, to provide IP-67 Degree of Protection to live parts and Internal Arc protection (IAC 20kA/l-sec). duly filled with SF6 gas with leakage rate less than 0.1% and partial discharge tested as per IEC 62271- 200. complete with all accessories as described below and coupling busbars with existing infrastructure where necessary, to meet the desired configuration. The earthing busbar should be of Copper and provided in each cable box & through the length of switchgear. (Make: SCHNEIDER / ABB / SIEMENS) The unit shall comprising of following. a) Load Break Switch module shall comprise of:- (i) Manual operated. 11 KV three position load break switch with snap-action knife blade mechanism, suitable to break upto 630amp of rated current, along with associated earthing switch of making capacity.
BOQ ITEM NO 162 (Contd..) (ii) True position semaphore indication of switch position 'ON'. 'OFF' and 'EARTH' on the front facia of the panel. (iii) "Live Cable "Indicating LEDs energized thru Capacitive Voltage Dividers shall be permanently available on the front facia without requiring any external instrumentation. Cable bushings shall be enclosed inside hinged door cable-box interlocked with respective Earthing switches. (iv) Right Angle terminal protectors boots for covering the cable termination
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed.
M&L returning and filling of trenches in two parts:- (i) using riddled soil obtained from excavated soil up to depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and as directed. Note: Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS-1255-1983 and refilling in trenches as in cable cushioning
Supply, install, testing and commissioning of out door type 11 KV/433Volts 500 KVA compact/package sub station with facility for internal lighting, earthing , padlocks etc including making necessary cable termination box for more than one of Incoming / Out going LT UG cables as per site requirement and directed by Engineer in Charge, comprising the following equipments .- Make :- ABB/ Schneider or equivalent in Siemens
BOQ ITEM NO 165 (Contd..) (A) HT Switchgear (B) Transformer (C) LT Panel (D) Enclosure of CSS (E) Inter Connection and Earthing (F) Civil Works (G) Marking, Testing and commissioning. (A) HT Switchgear 11 KV 630 Amps 21KA for 3 sec SF6 insulated Non extendable switch gear type CCV or equivalent consisting of Two Nos Fixed manual load break switch and one no I-fixed motarised vacuum circuit breaker in SF6 insulated and copper busbar Stainless steel enclosure with series trip self powered microprocessor based numerical over current and earth fault (IDMT + Inst) relay protection 1 No
BOQ ITEM NO 165 (Contd..) (a) Relay with communication 1 No (b) Protection CT's 40/1A 2 5 VA 10p10 1 set (c) Manometer 1 No (d) Voltage presence indicator 3 No (e) Fault passage indicator for incoming C module 1 No. (f) 24V DC battery and charger 12 Ah capacity. 1 set (g) Space Heater with Thermostat 1 No (h) Operating handle 1 No (j) Each LBS (Load Break Switch) and earthing switch with marking capacity and have the following:- (i) Mechanical ON/OFF/Earth indication (ii) Live cable “indicating LEDs" energized three capacitive voltage dividers (iii) Interlock arrangement b/w cable cover and isolator (iv) Cable box suitable for cable termination of 1No upto 3core 185 sqmm XLPE cable aluminum conductor (v) Flexible boots (vi) FPI for only one number LBS function shall be inbuilt O/C & E/F indication (vii) VCB function type 3 position disconnected and earthing switch equipped with separate drive unit. The VCB equipped with over current time release to transformer protection and SCADA Port facilities (viii) Aux contacts for VCB (2 No + 2 NC) (viiii) Capacitive voltage indication. (ix) Cable cover standard
BOQ ITEM NO 165 (Contd..) (B) TRANSFORMER (Typo : Cast Resin Dry Type) (i) Ratio - 11KV/ 433V (ii) Capacity - 500 KVA (iii) Vector group - Dyn 11 (iv) HV side OFF load tapping and steps as pei IS (v) Insulation class (HV/LV) - H (vi) Temperature rise 115 degree C in the winding over ambient temperature of 50 degree C (vii) No load losses - As per the IS standard (viii) Full load losses - As per the IS standard (ix) Total losses -- As per the IS standard (x) % Impedance, Reactance. Resistance - As per the IS standard (xi) Efficiency - As per the IS standard (xii) Regulation - As per the IS standard (xiii) Conforming to 11171/2026 & IEC-60076-II (xiv) Winding temperature indicator with alarm and trip contact (xv) Surge arrestor (xvi) Fittings / accessories Rating and diagram plate, base channel, earthing terminals, lifting, lugs. Bidirectional roller and WTI scanner with 3 PT - 100 sensors
BOQ ITEM NO 165 (Contd..) (C) LT PANEL LT panel shall be for suitable to use inside CSS for operation of 415 volts, 50 Hz, 3 phase. 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, busbar, inter connections earth terminals, labeling, cable alley suitable for termination of cable including supply and fixing of following switchgear and accessories in the panel with 2mm thick CRCA sheet complete as required size conforming to relevant IS specification The ACBs shall have the valid test certificate and all the LT side components shall be placed inside the CSS enclosures Test certificate for ingress protection tor enclosure needs to be provided. LT BUSBAR. (i) 800 Amps copper busbar (100% for phase and 50% for neutral.) (ii) Voltage rating - 433V, 50 Hz, AC. INCOMER (i) ACB 800A 50 KA 4P with Fixed Manual (FM) Adjustable type with microprocessor based release for over load, short circuit and earth fault protection-01 Set (ii) Set of indicating lamp (R Y.B) ON-OFF-TRIP indication with MOB protection - 01 Set (iii) Digital type multifunction meter of class 1.0 Accuracy to show Amp, Volts, KW. KWH, KVA, PF, Hz - 01 Set (iv) Suitable CTs of 800/5A. 5VA. OUTGOING ' (i) 400 Amps, 415V, 36 KA, MCCB TPN -02 Nos (ii) 260 Amps 415V, 36 KA MCCB TPN- 01 No. (iii) 250 Amps 415V, 36 KA MCCB TPN - 01 No
BOQ ITEM NO 165 (Contd..) (D) ENCLOSURE OF CSS (ONE SET) Outdoor type enclosure having construction of galvanized sheet steel of thickness 2mm for load bearing member and 1.5mm for non load bearing member with 4mm base frame The enclosures shall have IP 54 degree of protection for HT & LT switchgear compartment and IP 23 degree of protection for transformer compartment. Each compartment will be provided with the door and pad locking arrangement. The compartment Illumination lamp with door operated switch shall be provided for MV & LV compartment. Separate switch operated bulket lamp+ hooter in transformer compartment Transformer compartment door interlocked with breaker module. (E) INTERCONNECTION AND EARTHING(ONE SET) Interconnection between HT switchgear and transformer using minimum size of 1CX3X95 sqmm XLPE aluminum single core cable Inter connection between transformer and LT switchgear using copper busbars Internal earthing connections by using 50x6mm Gl strips including transformer neutral Note : (i) HT and LT compartments shall have degree of ingress protection IP 54 and that of transformer compartment shall be IP 23 (ii) The enclosure alongwith ail inside compartment shall be painted with poiyurelhane painting of suitable thickness not less 150 micron for costal condition. '(iii) Aluminium short pieces tor 3 phases and neutral of 800 Amps with nuts bolts and washers (set of two) shall be provided for by pass the ACBs when ACBs shall be out of order/under repair Size shape and holes of short pipes shall match the system and ready to fix for operation.
BOQ ITEM NO 165 (Contd..) (F) Civil works (i) All civil works including PCC platform for Compact sub station size, and related to foundations, cable trench, including of panel and equipments including making good and existing structure of disturbed during installation and commissioning The depth of the foundation and PCC as recommended by the manufacturer The rate deemed to be included in quoted rate. (ii)Make for all the equipments / materials incorporated in the work shall be as per the recommendation of the OEM. (iii) AII items of accessories,fittings,sundries.apparatus or labour whether specified in detail or not but which is necessary for successful commissioning of the compact sub station shall form part of installation cost (G) Marking,Testing and commissioning (i) Letter painting shall be carried out at the front and rear side of the panels transformer. VCBs including numbering of earthing etc specifying the full details and size of cables, feeder name in appropriate size as directed by Engineer-in- charge (ii) energising of Compact sub station is after pre-commissioning of appropriate authority of MES channel as specified and directed by Engineer-in- charge.
Supply, lay and testing of 185 sqmm 3 core cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 185 sqmm XLPE armoured aluminium conductor cable complete all as specified and as directed.
Supply and fix HT Route indicator including excavation and PCC foundation complete all as specified and as directed.
Supply,install,testing and commissioning of out door LT Automatic Power factor correction(APFC) panel for 3 Phase, 415V & 50Hz system of capacity 100KVAR with incoming MCCBs, CPRI approved weather / vermin proof made out of 3mm thick CRCA sheet factory assembled modular and non compartmentalized construction out door type with front side hinged double door with locking arrangement , floor mounted free standing type duly powder coated with Aluminium bus bar and multistrand copper cable of appropriate size for each feeder of with 10 step APFC Relay comprising of following all as directed. (i) MCCB 250Amps, 3 Pole , 25KA breaking capacity. (ii)MD-XL Capacitor 440v of following rating with heavy duty capacitor switching contactor.
BOQ ITEM NO 169 (Contd..) (a) 2 KVAR with 10KA MCB & Capacitor & contactor- 1 No (b) 3 KVAR with 10KA MCB & Capacitor & contactor - 1 No. (c) 5 KVAR with 10KA MCB & Capacitor & contactor - 3 Nos. (d)10 kVAR with 10KA MCB & Capacitor & contactor- 3 No. (e) 25 kVAR with 10kA MCB & Capacitor & contactor- 2 Nos (f) Microprocessor based intelligent power factor 10-Step relay with RS 485 Port type RVT of ABB Make or equivalent in Siemens/ Schneider (g) CONTROL COMPONENTS (i) CTR- 200/5A CL: 1. 5VA -3Nos. (ii) Digital Multi meter to measure Volt, amps and PF - 1NO. (iii) Indication Lamps for RYB (LED Type) - 3Nos. (iv) Out going Indication Lamps (LED Type) - ON/OFF - 10 Nos
Supply and install Inverter split type AC indoor and outdoor unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and of capacity 2.0 TR. Make/Model No : Copper, 2019 Model - KS-Q24ENXA of LG or equivalent in Bluestar / Hitachi.
Supply and install Inverter split type AC indoor and outdoor unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and of capacity 1.5 TR. Make/Model No : Copper RSOG518HDEA of Hitachi or equivalent in LG / Bluestar
Supply installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 complete all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make/Model No : V-Guard/VND 500 or equivalent approved make.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. Make/Model No : V-Guard/VND 400 or equivalent approved make.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V - 280V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 2 KVA. Make/Model No : V-Guard/VG 150 or equivalent approved make.
Supply and fix metal clad socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as directed.
Supply and fix air termination single pointed aluminium rod of 12mm dia and 300mm length fixed to aluminium strip 25x3.15 mm including nuts, bolts and washers complete all as specified and directed the Engineer in charge.
Supply and fix aluminium strip 25 x 3.15mm thick with saddles and fixing screws etc. For roof conductors above ground all as directed.
Supply and fix Galvanised iron strip 32 x 6mm thick as earthing lead fixed to roofs/buried in ground etc all as directed.
Supply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed.
Material and labour for earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw all as specified and directed.
M/S J J ENTERPRISES
Phoenix Infra
SREEKRISHNACONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .