Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical All Pre Qualifying conditions not Fulfilled |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
7 Feb 2024, 1:00 pmClosed
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room No. 61, LESA Bhawan, Near Residency Kaiserbagh, Lucknow
As per tender Specification
2024_MVVNL_887476_1
46/EUCC-V/LESA/2023-24
Open Tender
Electrical Works
30 days
33/11 KV Rajanikhand S/S o
AS per tender Specification
2 documents required · 2 mandatory
₹1,180
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹9,000
16 Apr 2024
30 Jan 2024
7 Feb 2024
30 Jan 2024
7 Feb 2024
30 Jan 2024
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV 3x300sqmm XLPE Cable
33 KV Jointing Kit 3x300 sq mm Cable Outdoor
33 KV Jointing Kit 3x300sq mm Straight Through
33 KV Control Pannel single Circuit feeder
33 KV Line Isolator
33 KV Bus Isolator 800 Amp
33 KV Lightening Arrester 400 Amp.
33 KV VCB 800 Amp, 750 MVA
33 KV Current Transformer 400/200/1A
ACSR Panther Conductor for Bus Bar
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
MS Angle 75x75x6 2.6M long 2 Nos. [email protected] Kg./M
Top channel/MS CHANNEL 100X50 MM 10 kg / mtr
MS angle 65x65x6MM 5.8 kg / mtr
STP 11 M long
33 KV pin insulator
33 KV pin with nut
M S Earthing Rod 20x2500 mm
LT XLPE Cable AL.1X400 Sq.mm.
Digging of pit in Kachcha/Pakka land in depth upto 1/6 length of pole, Dragging of STP from nearby place/dump, Erection of single pole along with stone pad in bottom with proper alignment on 11 mtr long ST pole and refilling with ramming of earth
Grouting of pole in depth of 01 mtr. Below ground level in ratio 1:4:8 in cement, sand and brick ballast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in ratio 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of new erected ST pole with two coat of Red oxide paint, PO red paint at top of pole 2 mtr and balance by two coats of best quality aluminium paint ISI mark as per norms.
Fabrication & erection of 33 KV Exposure type double pole with the provision of bus bar on 11 mtr. long ST-Pole with fixing of necessary clamps & other accesories like 02 No. Channel 100x50mm (1600 mm each) , 02 No. Bracing angle 65x65x6 mm (2800 mm each) for supporting the hoisting of cable on pole, 09 No. Pin insulator with pin, Danger board, number plates and Barbed wire etc. Its jumpering by single core PVC Al. Cable with proper size of lug (All required materials will be provided by contractor except ST- pole, steel parts, Pin insulator with pin and PVC Al. cable)
Laying of S/C 33 KV 3x300 Sqmm XLPE cable in normal soil by digging of trench 1050 mm deep & 500 mm wide its boxing with bricks, laying of cable, filling of sand upto top and covering with stone slab after laying of cable (All material will be provided by contractor except 33 KV cable)
Laying of 33 KV XLPE cable 3x300 sq mm S/C in MS/HDPE- Pipe 150 mm dia by digging of trench in Kachcha/Pakka of suitable size at road crossing (All material will be provided by contractor except 33 KV cable)
Laying of single 33 KV 3x300 Sqmm XLPE Cable by drill method
Cable Laying in already constructed trench/existing pipe S/C
Hoisting of 33 KV 3x300 Sqmm XLPE cable on D/P through GI- pipe of size 6" dia 3 mtr long including its jumpering complete with holding clamps, PG clamps, Nut & bolts (All material will be provided by contractor)
Making of Heat & shrinkables joints of following sizes and types in 33 KV XLPE cable(Jointing kit will be provided by deptt.)
Outdoor end termination kit for 33 KV 3x300 sqmm XLPE cable
Straight through jointing kit for 33 KV 3x300 sqmm
Digging of pit of size 3x2x1.2 mtr for making straight through joint of 33 KV cable size 3x300 Sqmm work included boxing of pit by sand, brick and stone slab filling of soil levelling and ramming of the same. (S/th provided by the deptt.)
Earthing of poles with MS- Earthing rod 20x2500 mm, earth wire with nut and bolts as per norms (All material will be provided by contractor except MS-Earthing rods).
High Pressure Testing of 33 KV cable. Testing equipment will be arranged by contractor.
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting of structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure/ PT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Painting of all structures (new and existing).
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4Nos foundation volts for erection of 33KV VCB.
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
2x2.5 sq mm
4x2.5 sq mm
6x2.5 sq mm
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Dragging of 33 KV Control pannel from unloading place upto control room and placement, erection, grouting commissioning & complete testing of the same as per RESPO Norms
Jumpering of complete line bay with ACSR panther Cond. with required clamp, nut & Bolts from Existing 33 KV bus bar & 33 KV cable complete work.(required PG clamps will be provided by contractor).
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing included in the job as per specification/norms for CT/LA and other.(All materials will be Provided by contractor)
Safe Dragging, loading, carriage and unloading of balanced materials with proper stacking from site to JE dump store/Lesa store after completion of work.
SINGH ENTERPRISES
S.M.ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid