Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC SOUTH DESHBANDHUPARA BB GHOSH SARANI NEAR DESHBANDHU VIDYAPITH SCHOOL PO SILIGURI TOWN 734004 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.1 L+₹50,416.50 (1.11%)Rejected-Finance VIVEKANANDA PALLY PO BAGDOGRA DIST DARJEELING PIN 734014 WB | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹46.5 L+₹93,049.50 (2.04%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹46.9 L+₹1.3 L (2.89%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹47.0 L+₹1.5 L (3.23%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹43.9 L
EMD Value
₹87,800
Closing Date
21 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bengdubi
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/45 OF 2021-22 PROVN OF OPEN SHED AND MINOR WORKS AT CERTAIN UNITS UNDER AGE B/R II OF GE BENGDUBI MIL STN
2021_MES_479109_1
GE/BENG/45 OF 2021-22
Open Tender
Civil Works
Item Rate
240 days
Bengdubi
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i)
8 documents required · 8 mandatory
₹500
Yes
GE Bengdubi
₹87,800
Yes
28 Oct 2021
1 Oct 2021
23 Oct 2021
1 Oct 2021
21 Oct 2021
16 Oct 2021
4 Oct 2021 - 9 Oct 2021
60 days
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Surface dressing n. exc. 15 cm deep in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.5 mtr deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc and getting out in soft/loose soil complete all as specified.
Excavation over area not exceeding 1.50 mtr deep and getting out in soft/loose soil complete all as specified.
Ditto all as per Item no 3.00 here-in-before but exceeding 1.5mtr not exceeding 3.0mtr deep complete all as specified.
Removing excavated material (soil) to a distance exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
M&L for approved earth (as approved by GE) from source outside MoD land including all roalty if any transporation taxes etc, for filling in floors including raising of original level upto height from OGL in layes n. exc 30 cm thick including watering, consolidation and finished to required size and shape all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L precast PCC 1:2:4 type B1 using 20mm graded aggregates for precast cement conc slabs as in manhole covers set in cement mortar 1:4 including formwork if required complete all as specified and directed. (Note : Precast man hole covers shall be casted on platform as approved by GE, and curing shall be carried out in water tank continously for 14 days, the cost of temp tank and plat form is deemed to be included in this item )
M&L hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
M&L for Fly ash brick work with old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with fly ash brick, straight or curved built in CM 1:4 as in half brick thick walls complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in lintel upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, fixing of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required complete all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete etc all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate for Columns, pillars, piers, posts etc all as specified and directed.
M&L for R.C.C M-25 (Design Mix) using 12.5 mm graded crushed stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span etc all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 10 mm dia & over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No. 21.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
M&L 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in flooring, finshed even and smooth without using extra cement complete all as specified and directed.
M&L 50mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in flooring, finshed even and smooth without using extra cement complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in subbase, path, steps etc.finshed even and smooth without using extra cement complete all as specified and directed.
M&L 100mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in subbase of hardstanding and ramp complete all as specified and directed.
M&L 75mm thick PCC 1:5:10 type E-2 using 40mm graded crushed stone aggregate as in subbase of floor complete all as specified and directed.
Supply only aluminium dividing strips 1.5mm thick and 28mm wide complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protections, finished even and smooth w/o using extra cement with joints 10 mm wide and in full depth at corners and @ 3.0 m c/c filled with mastic mortar complete all as specified and directed.
S&F roof trusses (farmed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing MS tubes medium grade as in truss, purlin, rafters, post etc fixed with and including angle cleat , MS plate etc including necessary welding, fittings etc Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins, Gusset plate and base plates, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe-410-Wgde -E-250) quality 'B' includng welding or riveting etc complete all as specified and as directed
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 60cm long and dia of neck from 20 mm to 25 mm complete all as specified and directed.
M&L Mild steel bolts n. exc. 12mm dia, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and directed.
M&L Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.for post (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming Fe-410W(GdeE-250) quality B complete all as specified and directed.
M&L for rolled mild steel works in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes including screw bolt with hexagonal at one end and screwed with washer and nut fitted Fe-410W(GdeE-250) quality B complete all as specified and directed.
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 etc complete all as specified and as directed
M&L Steel work in Square hollow section as in post/column including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed
S&F Pre-painted coloured trapezoidal profiled Galvalume / Zincalume sheet with min thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws complete as specified etc complete all as specified and directed.
S&F Pre-painted coloured plain Galvalume / Zincalume sheet with min thickness of 0.60 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof ridge colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer with Galvanised self drilling self tapping fastener (12-14 x 55 with EPDM seals) complete as specified etc complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specifie complete all as specified and directed.
S&F standard powder coated aluminium section and shall be approved by Garrison Engineer as in frame for door with cadmium plated steel screws, including rubber beading or gaskets for fixing glass and stainless steel wirecloth and particle board, etc complete all as specified and directed. Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment. (ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and particle board shall be measured and paid separately under respective items. (iii) The accessories required to be provided for partition as per directions of Engineer-in-chargeshall be provided but weight for the same shall not be considered and no extra cost will be paid.
S&F Prelaminated particle board 9mm thick, interior grade, prelaminated both sides with decorative choice laminations , fixed with screws or joining cleats to aluminium frame work complete all as specified and directed.
S&F 5.50mm thick sheet glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed.
S&F Floor door stopper 140mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F Mortice lock, Brass vertical type, size 75 mm complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors set and jointed with grey cement slurry and pointed with pigment to match the shade complete all as specified and directed
Taking down cement plaster any description on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 20 mm thick in CM (1:6) screed bed or bedding layer for laying floor finished complete all as specified and as directed
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 50mm thickness, M-35 Grade with gray cement and pigment complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed (Notes : WPC shall be measured and paid seperately)
Supply only water proofing compound (Liquid) complete all as specified and as directed.
M&L for preparing new plastered on wall and applying two coats of white wash over one coat of alkali resistant priming paint etc over a coat of wall care putty complete all as specified and directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as in walls etc. complete all as specified and directed.
M&L for rendering 20 (12+8)mm thick in two layers CM (1:4) on xternal surfaces of wall and top layer mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed (Notes : WPC shall be measured and paid seperately)
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described for two coat of Synthtic Enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for Loose filling with brocken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed.
Taking down chowkats or frames exc 1.5 and n exc 4.0 Sqm each (with out taking off shutter from the frame) and removing material from the site of work complete all as directed
M&L for PCC 1:3:6 type C2 as in bed to drain pipe including packing under haunching against sides of pipe after laying in trenches for 150 mm dia bore drain pipe including testing complete all as specified and directed.
S&F 150 mm dia SGSW pipe grade 'A' laid in trenches including jointing with cement mortar 1:1 complete all as specified and directed.
S&F 100 mm dia cast iron (sand cast) soil waste and vent pipes in any length fixed with cement joints fixed to wall complete all as specified and directed.
S&F 100 mm dia cast iron (sand cast) soil waste cowl complete all as specified and directed.
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F Salt-glazed stoneware gully traps, square or round mouthed of size 150x150mm, (type 'P' or 'S') setting and jointing to drains with cement mortar 1:1 complete all as specified and directed.
M&L for Cutting salt-glazed stoneware drain pipe in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar(1:1) 150mm internal dia of pipe complete all as specified and directed.
T K GANGULY
GOUTAM KUMAR GHOSH
M/S SANKAR BHATTACHARYA
PRADIP KUMAR BOSE
NAYAK BROTHERS
MUKHERJEE ENTERPRISE
Prahalad Rai
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .