Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 1 1 A VANSATTART ROW 3RD FLOOR ROOM NO 2A | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.8 L+₹488.64 (0.04%)Rejected-Finance 1 1A VANSITART ROW 2ND FLOOR ROOM NO 2 KOL 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹12.9 L+₹5,255.84 (0.41%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L3 | Rejected-Finance Higher than L1 |
| Sl No | Description | Qty | Unit | ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. L2 | JDJ ENTERPRISE. A UNIT OF JDJ TRADERS PRIVATE LIMITED L1 | ORIENTAL ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|
| 1.00Supply & delivery of the following materials at site: | ||||||
| 1.10UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure-5 Bar, Operating Tran membrane Pressure -2 psig, Maximum Backwash- 20 psig as per following specification:- a) Filtrate Flow- 12.1-29.5 gpm 2.7-6.7m³/hr) b) Filtrate Turbidity-≥00.7 NTU c)Virus removal-≥ 4 log d) Bacteria removal-≥ 4 log e) Configaration :- Capillary Ultrarafitration Module f) Membrane Polymar:- Hydrophilic Poly thersulfone g) Nominal Membrance Area :- 500 ft²(46m² ) or above h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) i) Pore size:- 0.02 micron or less j) Typical Filtrate Flux Range:- 35-85 gfd (59-145l/m²/h) k) Maximum Applied Feed Pressure. 73 psig (5bar) l) Maximum Transmenibrane Pressure - 20psig (1.4 bar) m) Maximum backwash transtnembrance Pressure :- 20 usig (1.4 bar) n) Instantaneous Chlorine Tolerance :- 100 ppm o) Instantaneous Hydrogen Peroxide Tolerance :- 200 ppm** p) maximum chlorine Expossure :-200.000ppm-hrs q) maximum instantaneous Feed Turbidity :- 100 NTU r) Maximum Operating Temperature:- 104° F s) pH operatin range:- 4.0-10.0 t) Clraning pH Range- 1.5-13.0 u) Operating Mode:- Inside to Outside Filtration Direct flow of Crossflow. | ||||||
| 1.20 | v) Backwash flux-100-150 gfd (170-255 l/m²/hr)
w) Backwash Duration -30-60 seconds.
x) Backwash Frequency-20-60 minutes.
y) Chemical Enhanced Backwash Frequrncy-0-4 ties per day
z) Chemical Enhanced Backwash Duration-1-30 minutes
z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or , NH₂CL
z2) Cleani9ng Chemicals -NaOH, HCL, H₂SO₄, or Citric Acid
(Make- Hydranautics /Dow/Toray/GE) | 2 | nos. | 5,38,000 ₹10,76,000 | 5,37,795 ₹10,75,590 Lowest | 5,40,000 ₹10,80,000 |
| 2.00 | Add: 18% GST | 1 | Item | 1,93,680 ₹1,93,680 | 1,93,606.2 ₹1,93,606.2 Lowest | 1,94,400 ₹1,94,400 |
| 3.00 | Add: 1% CESS | 1 | Item | 12,696.8 ₹12,696.8 | 12,691.96 ₹12,691.96 Lowest | 12,744 ₹12,744 |
Tender Value
Refer Docs
EMD Value
₹35,793
Closing Date
11 Apr 2025, 6:00 pmClosed
Executive Engineer Electrical Division PHED
P16 India Exchange Place CIT Annexe Bldg Extn 2nd floor Kol 73
E/M works
2025_PHED_830743_25
WBPHED / EE / ED / 19 / 2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
21 days
Office of the Executive Engineer ED PHED
Please refer Tender documents.
7 documents required · 7 mandatory
₹35,793
3 Jun 2026
25 Mar 2025
16 Apr 2025
25 Mar 2025
11 Apr 2025
25 Mar 2025
Amount
Supply & delivery of the following materials at site:
UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure-5 Bar, Operating Tran membrane Pressure -2 psig, Maximum Backwash- 20 psig as per following specification:- a) Filtrate Flow- 12.1-29.5 gpm 2.7-6.7m³/hr) b) Filtrate Turbidity-≥00.7 NTU c)Virus removal-≥ 4 log d) Bacteria removal-≥ 4 log e) Configaration :- Capillary Ultrarafitration Module f) Membrane Polymar:- Hydrophilic Poly thersulfone g) Nominal Membrance Area :- 500 ft²(46m² ) or above h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) i) Pore size:- 0.02 micron or less j) Typical Filtrate Flux Range:- 35-85 gfd (59-145l/m²/h) k) Maximum Applied Feed Pressure. 73 psig (5bar) l) Maximum Transmenibrane Pressure - 20psig (1.4 bar) m) Maximum backwash transtnembrance Pressure :- 20 usig (1.4 bar) n) Instantaneous Chlorine Tolerance :- 100 ppm o) Instantaneous Hydrogen Peroxide Tolerance :- 200 ppm** p) maximum chlorine Expossure :-200.000ppm-hrs q) maximum instantaneous Feed Turbidity :- 100 NTU r) Maximum Operating Temperature:- 104° F s) pH operatin range:- 4.0-10.0 t) Clraning pH Range- 1.5-13.0 u) Operating Mode:- Inside to Outside Filtration Direct flow of Crossflow.
v) Backwash flux-100-150 gfd (170-255 l/m²/hr) w) Backwash Duration -30-60 seconds. x) Backwash Frequency-20-60 minutes. y) Chemical Enhanced Backwash Frequrncy-0-4 ties per day z) Chemical Enhanced Backwash Duration-1-30 minutes z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or , NH₂CL z2) Cleani9ng Chemicals -NaOH, HCL, H₂SO₄, or Citric Acid (Make- Hydranautics /Dow/Toray/GE)
Add: 18% GST
Add: 1% CESS
ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. (BID ID -6276328)
ORIENTAL ENGINEERING CO. (BID ID -6283367)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .