Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC PANDANESWAR BARDHAMAN BARDHAMAN 713346 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713346 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.2 L+₹37,782.23 (2.01%)Rejected-Finance KHOITADIH PROJECT BILPAHARI BARDHAMAN BARDHAMAN 713378 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713378 | L2 | Rejected-Finance L2 | |
| 3 | L3₹19.6 L+₹75,877.86 (4.03%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹18.8 L
EMD Value
₹23,600
Closing Date
25 Jul 2023, 11:00 amClosed
GENERAL MANAGER, JHANJRA AREA
OFFICE OF THE GENERAL MANAGER, JHANJRA AREA, PO-LAUDOHA, BO, DIST. - PASCHIM BARDHAMAN, PIN-713385
Transportation, installation, fabrication, commissioning and trial run including extension of one no. 1000mm width, 1x90kW, 550 V Single drive belt conveyor along 80L from -11D to 0D for development of panel 9 in R-VIIA seam at 3n4 incline, jpc
2023_ECL_283649_1
ECL/GM/JNR/EnM/e-TenderCell/ 23-24/018
Open Tender
Miscellaneous Works
Item Rate
90 days
JHANJRA UNDERGROUND
Please refer Tender documents.
4 documents required · 4 mandatory
₹23,600
22 Sept 2023
14 Jul 2023
26 Jul 2023
14 Jul 2023
25 Jul 2023
15 Jul 2023
14 Jul 2023 - 21 Jul 2023
Amount
Transportation, installation of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor for length of 103.5 mtr from 80L/ -11D to 80L/-8D in RVIIA seam at 3&4 incline, J.P. Colliery.
Transportation of the 1000mm width, 1x90kW, 550V Drive Head complete including gear box, motor(90kW/550V), couplings, bearing blocks, fencing etc from surface and installation at 80L/-10D (R-VIIA) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plates, scrappers etc from surface and installation at 80L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Loop Take Up Unit complete with motorized winch from surface and installation at 80L/[(-10D)-(-9D)] (R-VIIA) with necessary fabrication job.
Transportation of Tail End Unit complete with fencing from surface and installation at 80L/-8D (R-VIIA) with necessary fabrication job.
Transportation of 103.5mtr. 1000mm belt conveyor structure complete with stringer, foot stool, top bracket, top & bottom roller etc. from surface to 80L belt installation site and installation from 80L/-11D to 80L/-8D in R-VIIA seam.
Loading, transportation and unloading of one breaker(550V/200A), starter(550V/90kW), LS unit from surface to 80L/-10D(R-VIIA) with help of haulages & 60 mtr manually. (Distance- approx. 2600mtr.)
Transportation of 100mtr 3.3kV grade 70 sq.mm. PVCDWA cable from surface to 78L/-10D(R- VIIA) with help of haulages and Laying-hanging this cable from 78L/-10D ACB to 80L/-10D ACB manually. (Distance-approx. 2600mtr.)
Making of drive head base frame & tail end frame at site with ISMB-250.
Transportation of 230mtr. 1000mm width PVC belting from surface to 80L belt installation site with help of haulages & 60mtr manually. (Distance- approx. 2600mtr.)
Laying, lapping, jointing & tensioning of this 230mtr. 1000mm width PVC belting in proposed 80L belt.
Transportation of 250mtr belt sequence cable from surafce to 76L/-10D(R-VIIA); then laying- placing them from 76L/-11D starter to 80L/-10D starter in R-VIIA seam.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) from suarfce to 80L belt installation site with help of haulages for 103.5mtr. belt and laying-placing them from 80L/- 11D to 80L/-8D in R-VIIA seam.
Testing, trial run, alignment & commissioning of this belt conveyor from 80L/-11D to 80L/-8D in R-VIIA seam.
Eight times extension of the proposed 80l belt conveyor from 80L/-8D to 80L/0D for a length of 276 mtr. in R- VIIA seam of 3&4 Incline Unit, JPC.
Eight times dismantling of tail end unit complete for eight times belt extension of proposed 80L belt.
Eight times transportation and installation of tail end unit complete for eight times belt extension of proposed 80L belt from 80L/-8D (R-VIIA ) to 80L/0D (R-VIIA).
Transportation of 1000mm belt structures (i.e. foot stools, channels, brackets, top and bottom rollers etc.) for a length of 276mtr. from surface to belt extension site by haulages and installation them from 80L/-8D to 80L/OD in R-VIIA seam during eight times belt extension.*Each time belt extension will be for a length of 34.5 mtr.
Transportation of 552mtr. 1000mm PVC belting from surface through haulages & 60mtr. manually to 80L(R-VII) belt extension site.
Laying, Lapping, Jointing & Tensioning of this 552mtr. 1000mm belting from 80L-8D to 80L/OD in R-VIIA seam during eight times belt extension and trial run.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) for 276 mtr. belt from surface to 80L belt extension site and laying & fitting them during eight times belt extension.
Civil foundation works for installation of 1X90kW, 550V, 1000mm wide belt conveyer drive head, discharge unit, loop take-up unit and platform for ACB, Starter for 80L belt conveyor of 3&4 incline, JPC.
Recess cutting in stone
Cleaning of debris/Muck
Sand filling
Brickwork with flyash bricks in foundation & plinth in cement mortar 1:6
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
12 mm cement plaster of mix 1:6
Loading material into tub and loading at site
Roof heightening by drilling blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for installation of proposed 82L belt conveyor in R-VII seam of 3&4 incline under JPC.
Roof heightening by drilling blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for installation of proposed 82L belt conveyor in R-VII seam of 3&4 incline under JPC.
Roof bolting including carrying of materials from surface to UG side, drilling, grouting & cost of drill rod and drill bit
Supply of materials
Supply of DA Cylinder
Supply of Oxygen Cylinder
Supply of MS Nut+Bolt of 5/8" X 2" (6 Nos per KG)
Supply of HT NuttBolt of M20 X 75mm
Supply of HT Nutt+Bolt of M20 X 65mm
Supply of HT Nutt+Bolt of M20 X 140mm
Supply of HT Nutt+Bolt of M20 X 120mm
Supply of 5 ton trun buckle
Total impact of GST for the purpose of CTC
BABLU SINHA
K R ENTERPRISE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .