Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹22.3 L+₹1.3 L (6.22%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹23.5 L+₹2.6 L (12.2%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹24.0 L+₹3.1 L (14.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
10 Feb 2021, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda
SPECIAL REPAIR TO AEC AND PEC BUILDING FOR HSSC,SPECIAL REPAIR TO CERTAIN BUILDING DAMAGED DUE TO RECENT STORM DAMAGES AND CERTAIN REVENUE WORK AT AFS KALAIKUNDA UNDER GE(AF) KALAIKUNDA.
2020_MES_408582_1
8632/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Kalaikunda
AS PER NIT
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Kalaikunda
₹5.3 L
Yes
23 Mar 2021
1 Jan 2021
12 Feb 2021
1 Jan 2021
10 Feb 2021
16 Jan 2021
Amount
Demolition of Reinforced cement concreteof any description and in any position not otherwise specifically provided for complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Dismantling plain or corrugated steel sheeting ,any gauge, thickness, including Nainital or Similar pattern roof coverings complete and keeping serviceable sheets in safe custody for reuse in the work as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as directed.
Dismantling of Asbestos cement (corrugated, semi corrugated etc) sheets in roof covering complete all as directed.
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) n. exc. 1.5 Sq. M each, complete all as directed.
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) exc. 1.5 Sq. M but not exc. 4.0 Sq M each, complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Taking up or down, steel tubing 15 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
M & L Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out soft loose soil complete all as specfied and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil ,complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified and directed.
Muroom/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering complete all as specified and directed.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
M&L providing and fixing of false ceiling with powder coated exposed GI grid suspension system (E-grid T-2420 or equivalent of Armstrong having load carrying capacity of 12.5 Kg/M3 with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200/600 mm long and Wall Angle. The wall angle shall be fixed on PVC dash fasteners on the perimeter of the wall with steel screws with distance 300 mm c/c. The main runners to be placed @ 1200 mm, the cross tee 1200 mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200x600mm. Additional cross tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm x 600 mm with and including 6 mm thick HSPC (High pressure steam cured) oceanic pre primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4 mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 kg/clip), hold down clips (wt-0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. Make Armstrong or equivalent make as mentioned in PS
Material and labour for (seamless) suspended ceiling which includes GI perimeter channels with zinc coating of grade 120 gram per sqm as per IS 277 of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and web of 27mm) along with perimeter of ceiling, fixed with screw to brick wall with half of nylon sleeves and screws at 610mm center to center. Then suspended GI intermediate channels of size 450mm (0.90mm thick with two flange of 15mm each) from soffit at 1220mm center to center with ceiling angle of width 25mm x 10mm x 0.55mm thick fixed to soffit, trusses rafters or pipe etc. with GI cleat and steel expansion fasteners Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to intermediate channel with the half of connection clip and in direction perpendicular to the intermediate channel at 457mm center to center with and including 12 mm thick gypsum Board ,(M/s Ramco Industries Limited or euivalent make ) is then screw fixed to ceiling section with 25mm drywall / countersunk ribbed head Self tapping screws at 200mm centers. Screw fixing is done mechanically either with screwdriver or drilling machine with suitable attachment and then finally the boards are to be jointed and finished so as to have flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint proper tape as per manufacturer instruction complete of all as specified and directed
Materials and Labour for Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed.
Materials and Labour for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, with built in cement mortar(1:6) complete all as specified and directed.
Materials and Labour for making good under cills or over arches, lintels and bressummers. including all pinning when necessary with cement mortar (1:4) complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) Type B-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Materials and Labour for reinforced cement concrete 1: 1½ :3, Type A1(using 20 mm graded aggregated) in beams, cantilever, bressumers, lintels over 1.5M Span,complete all as specified and directed.
Materials and Labour for reinforced cement concrete 1: 1½ :3, Type A1(using 20 mm graded aggregated) in chajjas,complete all as specified and directed.
Materials and Labour for reinforced cement concrete 1: 1½ :3, Type A1(using 20 mm graded aggregated) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like,,complete all as specified and directed.
M&L Precast cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate set in CM(1:4) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed.
Materials and Labour for 25 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate as floor/paving/hardstanding , complete all as specified and directed.
Materials and Labour for 25 mm thick plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate as in sub base floor/paving/hardstanding , complete all as specified and directed.
M&L concrete bed PCC (1:3:6) type C2 to drain pipes including packing under & haunching against sides of pipe after they are laid & tested for 110mm bore pipe complete all as specified and directed
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan half brick work built in cement mortar (1:4), complete all as specified and directed.
Use and waste of form work to chullah hoods, chajjas,troughs and similar items including edges for fair finished surfaces of concrete, flat, complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings , girders, bressummers, lintels, cantilevers, shelves including supports,overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, flat, complete all as specified and directed.
Supply and Fix, factory made rigid lam PVC door frame of size 100 mm x 50 mm, double rebated with wall thickness of extruded 5mm PVC sheet of density 600 kgs/cum , made by joining 3 Nos. heat bent PVC sheet sections. The inside section of size 90mm x 30 mm shall be made from colour PVC sheet of 5 mm thickness.The inside section shall be covered by sticking two sections of size 35mm and 6 x 45 mm made from 5mm thick plain sheet. The frame shall be mitred cut at two corners and jointed by inserting 4 Nos. 150 mm long brackets of 15mm x15 mm MS square tube. The two vertical members of door frame shall be reinforced with 40mm x 20 mm MS tubes of 19 SWG duly filled with 2nd class hardwood throughout the frame. The door frame shall be fixed to the wall using 100 mm long nikel coated dry wheet screws through the frame by using PVC fastener. Minimum 04 Nos. of screws shall be provided for each vertical member and minimum 02 Nos.for horizontal members etc. as per manufacturers specifications, fixed in opening, complete all as specified and directed.
Supply and Fix, factory Made Solid PVC Moulded Door designer Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2 mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and directed.
35 mm thick plain framed, factory made panelled shutter (second class hard wood rails & styles) (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and Fix,IS markedStainless steel butt hinges, medium weight, cold rolled 100 mm size complete all as specified and directed
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 200 mm long complete all as specified and directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long complete all as specified and directed.
Supply and Fix, extruded aluminium alloy handles, fabricated type, anodized, 150 mm size, complete all as specified and directed.
Supply and Fix,in repair Aluminium Alloy, anodised, sliding door bolt, length of bolt 300 mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Supply and Fix, Aluminium Alloy, anodised, sliding door bolt, length of bolt 300 mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.Make(Tata bluescope/Sexena Marine Tech /Jindal or equivalent make)
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.(Tata bluescope/Sexena Marine Tech/Jindal or equivalent make)
M&L 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs, walls, etc. Fixed with coach screws complete all as specified and directed
M&L Asbestos cement one piece plain angular ridge 6mm thick Fixed with coach screws complete all as specified and directed
S & F Anodised aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. Note : (i) Glass panes & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
S & F for Anodised aluminium door shutters with of any colour , aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S&F Anodised aluminium window & ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S & F double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S & F brass mortice lock for aluminium door , vertical type, 4 Levers and 100mm size complete all as specified and directed
S&F 150mm size floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
Glazing with sheet glass 5.5 mm thick superior quality in panels of aluminium windows, ventilator,door etc. fixed with glazing clips, rubber beading and EDPM gasket in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F for 4.8mm thick tinted glass of superior quality fixed to alluminium frame works with rubber beadings n.exc 0.5 sqm of each pane, complete all as specified and as directed.
S & F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n'exc 0.50 sqm in each pane complete as specified.
S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n'exc 0.50 sqm in each pane complete as specified.
S & F of figured glass, pin head type 4mm thick in squares n.exc 0.50 Sqm in each pane complete all as specified and as directed.
S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n'exc 0.50 sqm in each pane complete as specified.
S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane complete as specified.
S & F for door closer Aluminium die cast body Hydraulically regulated designation No.3 universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg complete all as specified and as dierected.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal/wooden frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and fix mild steel TMT bars 6 to 8 mm dia., cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and fix mild steel TMT bars 5 mm dia. and over up to and including 10 mm dia. in stirrups, spacers, binders etc. cut to length, bend to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
Supply and Fix, mild steel screw bolts (machine made), with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, diameter of shank 11 to 15 mm, length of bolt exc. 5cm long dia but n.exc 10cm, complete all as specified and directed.
Materials and Labour for rolled mild steel,Fe 410-W (Grade E-250) Quality-A in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary gusset plates, riveting etc as in Vertical post conforming to Fe-290, Gde-E-165 all complete all as specified and as direcetd.
S&F Rolled mild steel sections as in framing for cladding, glazing & for Vertical post for roof truss the like fixed with angle cleats & connecting plates, etc.GDE Fe410-0 or Fe 310-O complete all as specified and as direcetd
Supply and Fix, Rolled Mild Steel, Fe 410 W (Grade E- 250) Quality-B, in plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachments, complete all as specified and directed.
Rolled mild steel of grade Fe-410-W (Gde E-250) (quality A) in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.
S&F Mild steel, plain black sheet 0.63mm thick in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs & funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets,etc. as required complete all as specified and directed.
S&F Mild steel, plain black sheet 1.25mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lalmination fixed in aluminium frame work complete all as specified and as directed.
Materials and Labour for 100 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded aggregates as sub base floor including finishing surface even and rough complete all as specified and directed.
M & L 100 mm thick cement concrete 1:2:4 Type B1 ( using 20 mm graded stone aggregates) as in flooring laid in alternate panels including necessary formwork, finished even and smooth without using extra cement complete all as directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,conforming to IS 15622, ISO 13006, EN 14411 Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and MAKE:- (Johnson/Kajaria or equivalent make ) directed.
Materials and Labour for, digital ceramic coloured tiles, 450 X 300 X 7 mm thick, conforming to ISO 13006, EN 14411 , Group B III, on vertical surface of wall such as dados, skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match with over and including 10mm thick cement mortar (1:3) rendering complete all as specified and directed. MAKE:- Johnson/Regency/Kajaria)
Materials and Labour for, digital ceramic coloured tiles, 350 X 250 X 7 mm thick, conforming to ISO 13006, EN 14411 , Group B III, on vertical surface of wall such as dados, skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match with over and including 10mm thick cement mortar (1:3) rendering complete all as specified and directed. MAKE:- Johnson/Regency/Kajaria)
M & L for Digital Vitrified ceramic tiles Light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
M & L for Digital Vitrified ceramic tiles Light Shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm, as riser of steps, skirting, dado and pillar laid with and including 15 thick rendering Cement mortar (1:3) complete all as specified and directed
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on other than fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be deemed to included in quoated rates)
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered or un -plastered from walls, etc and applying two coats acrylic distemper on walls, over and including a coat of 1 mm thick white wall care putty complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
Material and Labour for applying two coats of acrylic distemper, white or tinted, to old un -decorated plastered surfaces on walls including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of acrylic distemper, white or tinted, to old un -decorated plastered surfaces on ceiling including preparation of surfaces complete all as specified and directed.
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to old plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.Note (Work shall be exectuted through authorised applicator and shall be got approved by GE before commencement of work)
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Material and Labour for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I complete, all as specified and directed.
Materials and Labour for, Ball valves high pressure of PTMT (Minimum weight 210 gms) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, 25 mm bore and fixed complete all as specified and directed.
Supply and Fix, bib tap, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
Supply and Fix, stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 15 mm bore, complete all as specified and directed.
Supply and Fix, pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, 15 mm bore, complete all as specified and directed.
Materials and Labour for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified and directed.
S&F vitreous chaina wash hand basin 550x400mm (flat back type) including cutting for and pinning in ends of brackets with and including half pedastal , waste fittings, CP pillar tap with capstan head, and waste water pipe complite all as specified and as directed.
S & F Vitreous China wash down water closet pan (Pedestal pattern), white (including fixing bolts, flushing cistern and flush pipe with and including PVC seat cover complete all as specified and as directed. (Make : Hindware of cat No 20012 or equivalent of Paryware/Cera)
Supply and Fix PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle, of capacity 10 Litres, including brackets, flush pipe, complete all as specified and directed.
Supply and Fix sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. Make Cat no. CAN-CHR-1171N of Jaquar or equivalent make of Kohler/Marc
Supply and Fix, soap dish, fixed in wall, complete all as specified and directed.Make Catpart no.AQN-7731 of Jaquar or equivalent make of Kohler/Marc
Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 mm,complete all as specified and directed.
M&L cast iron soil, waste and vent pipe any length with or without ears with cement joints laid in trenches or in floors 100mm dia ,complete all as specified and directed.
M&L cast iron soil, waste and vent pipe any length with or without ears with cement joints laid in trenches or in floors 75mm dia complete all as specified and directed.
S&F Cast iron 75mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
M&L Cast iron Nahani trap 100mm dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Supply and fix PVC waste pipe 32mm/40mm dia 800mm long with suitable socket for WHB/Sink ,complete all as specified and directed.
S&F Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F brass chromium plated hand shower (health faucet) complete all as specified and as directed. Make- Jaquar cat No-ALD-BLK-583 or Marc/Kohler)
Supply and Fix, 110 mm bore UPVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls or laid in trenches with including fittings, complete all as specified and directed.
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
Materials and Labour for, broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
Supply and Fix, sinks with drainage board made of stainless steel 1mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 950mm x 510mm bowl size 410mm x 410mm x 230mm, with and complete all as specified and directed.
Supply and Fix, PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement with dia. of out let 75 mm, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for, one light point or one fan point/Exhaust Fan controlled by one switch, complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule. . (i) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switch/socket outlet etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 pin socket outlet, 5 amps, independent,, complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule. (i) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switch/socket outlet etc and including 2.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 pin socket outlet, 5/15 amps, independent,, complete all as specified and directed.Note : Wiring to be done as per approved colour code in IE rule. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. (iii) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
Materials and Labour for point wiring with 4.00 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switch/socket outlet etc and including 4.00 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 pin socket outlet, 15 amps, independent,, complete all as specified and directed.Note : Wiring to be done as per approved colour code in IE rule. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring.
M & L for surface point wiring for one light/fan point with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19mm dia nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (ii)Wiring to be done as per approved colour code in IE rule. (iv) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring
Supply and Fix, switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and Fix, ceiling rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 6 pin 16A, 5 in 1 flush type, complete all as specified and directed.
S&F in repair DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door with 160 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 160 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neatly in wall and making disturbed surfaces as per existing specification complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507746 Model: (Ekinox-3) , MCCB 160 Amp Cat No. 420047, Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S&F in repair DB Box, in sheet metal enclosure VT DB TPN, MCB DB TPN 4 way, double door, with MCB as incomer, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, with provision for FP MCB as incomer and SP/TP MCB`s as out going, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507725 or equivalent in Seimens/ Schinder. Note : (i) MCB and DB box shall be of same make.
S & F in repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 12 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507612 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F in repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507611 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S & F MCB SP 6-32 Amp , AC , 220 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F MCB SPN 6-32 Amp , AC , 220 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F MCB TP 6-32 Amp , AC , 415 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F MCB, 4 Pole, 40-63 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S&F Signal Pole & Neutral enclouser with two pole and earth metel plug and socket for AC , with and including 20 Amp SP MCB, 220 Volt , 10 kA , C-curve complete all as specified and as directed by Engr-In- Charg.
S&F Tempra Plug socket DB, industrial type, Single Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with 32 Amp SPN MCB (2P+E -DP), 220 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 P-17, Cat Part No. 507863 or equivalent in Seimens/ Schinder. Note : Unit rate of item is including cost of SPN MCB 32 Amp, 10 KA, C Curve.
S&F Tempra Plug socket DB, industrial type, Three Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with 32 Amp FP MCB (3P+N+E - FP), 415 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 P-17, Cat Part No. 507862 or equivalent in Seimens/ Schinder.Note : Unit rate of item is including cost of Four pole MCB 32 Amp, 10 KA, C Curve.
S&F Tempra Plug socket DB, industrial type, Three Pole & Neutral enclouser, As per IEC 61439-3, IK 08, suitable for flush / surface mounting, with 63 Amp FP MCB (3P+N+E - FP), 415 V , 10 kA , C-curve, including socket and plug, making all electrical connections, including providing of suit size copper lugs etc complete all as specified and as directed by Engr-In- Charge.Make- Legrand, Model Ekinox 3 P17, Cat Part No. 507864 or equivalent in Seimens/ Schinder.Note : Unit rate of item is including cost of FP MCB 63 Amp, 10 KA, C Curve.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete.
M&L for Sub main wiring with three single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) .
S & F LED light fittings , recessed mounting , 600 mm x 600 mm, 36 watt, having efficient LED glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flate white high tramission acrylic cover including all hanging arrangement and fixing by providing hanging chain and providing electric connection from ceiling rose with PVC insulated, PVC sheathed, 1.0 Sqmm x 3 core copper conductor cable complete all as specified and as directed by Engr-in-Charge.(Make:- Bajaj Cat No:- BZRSQL 36W Gzi WHLED (LED) OR Century Cat No. PCA C 036C equivelant in / Crompton/Wipro
S&F LED 2 X 18 Watt tube light fitting (T8 type) , including LED retrofit tube 2 x 18 W , 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make Bajaj, Cat Part Batten : BLRB -DB218 Cat Part : LED refrofit tube :BLRB18W CW LED or equivalent Century/ Crompton. Note : Batten and tube shall be of same Make.
M&L for shifting of AC split type of 1.5/ 2.0 TR capacity by taking out both indoor and out door unit, copper piping, electrical connection cable, voltage stablizer, mounting stand etc from exiting location, transporting in safe way to new location and refixing complete assembly, mounting stand and voltage stablizer at new location, making all connection, connecting copper refrigent piping, providing thermal insulation cover on piping, making electrical connection, installation of voltage stablizer including all civil work like making opening in wall for passing of refrigent pipe and electrical wire from indoor to outdoor unit, closing the opening with cement morter at exiting location etc and making good disturbed surfaces as per existing specification complete all as specified by Eng in Charge.
Supply and fixing wall mounted fan 400 mm sweep, Air delivery 72 CMM, with high speed motor of min wattage 50-55 watt, 240 V, 50 Hz, 1350 RPM, No. of speed -03 Nos, with thermal overload protector, having oscillation, up and down tilting and remote operated feature, white colour complete all as specified and directed by Engineer in Charge. Make : Havells Model Platina, or equivalent in Bajaj/ Crompton/ Usha
S&F Sheet metal one way enclouser for MCCB , suitable for accomodating 4 Pole MCCB up to rating of 160 Amp, in CRCA sheet, as per IEC 61439-3 IK 08, suitable for flush / surface mounting, complete all as specified and as directed by Engr-In- Charge including taking down old u/s.Make- Legrand, Model Ekinox 3 , Cat Part No. 507861 (DPX 3 160 MCCB enclosure) or equivalent in Seimens/ Schinder.
S&F MCCB 160 Amp, 4 Pole , 16 kA, 415 V, AC, 50 Hz, Thermalmegnetic protection, with adjustable sensitivity and adjustable tripping , Ics = 100%Icu including making all electrical connection by providing copper lugs etc .Make- Legrand, Model : DPX 3 MCCB, Cat Part No. 420057 (DPX 3 160 type MCCB ) or equivalent in Seimens/ Schinder.
M&L for shifting and repairing of flame proof light tube light fitting from one location to other loaction in Bldg with repair/ replacement of light fitting with replacement of tube lamp, choke wire etc to make it functional, including fixing of light fitting by providing anchore fasterner, connecting light fitting to power supply point by providing PVC sheathed Copper conductor wire 1.5 Sqmm x 3 core complete all as specified and directed by Eng in Charge.
M&L in repair shifting of TPN DB from one location to other for making opening in for door in Room by taking out DB extending and shifting existing wiring to new location by providing extra wires jointing tapping , in casing capping including making all electrical connections complete all as directed by EIC.
M&L for taking down existing serviceable LED tube light fitting any type and any wattage from existing location and to fix in new location including connecting light fitting to power supply point by providing PVC sheathed Copper conductor wire 1.5 Sqmm x 3 core complete all as specified and directed by Eng in Charge.
Supply and Fixing Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed by EIC.
M&L for taking down existing serviceable LED light fitting of 600 mm x 600 mm recess mounting any type and any wattage from ( false ceiling) existing location and to fixing in existing or new location on new false ceiling including connecting light fitting to power supply point by providing PVC sheathed Copper conductor wire 1.5 Sqmm x 3 core complete all as specified and directed by Eng in Charge.
M&L for taking out old unserviceable LT cable of any size/ type from trenches/ wall/ roof etc. for necessary repair/ replacement/ re-laying works complete all as specified and directed by Engr-in-Charge.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded,armour galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends, saddling cable on wall by providing saddles or laying in trenches as required on site complete all as specified and directed by EIC.
Taking down old unserviceable GI/ chemical earthing from soft / hard soil as directed by EIC.
M&L for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns.Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 mtrs long zinc coated with with additional special alloy coating 300mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compact fill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pits of min size 1000 X 1000 X 3000 mm depth taking out excavated soil,lowering the pipe in pipe earth electrode,filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacity in 250 mm around the electrode min 4 bags of 25 KG per pit per unit. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colour.complete all as specified and directed. Make : ASHLOK ( Model ASEEL-39 AC 3 mtr length 76.3 mm dia Note :- (i) Design of earth electrode should be of pipein-pipe technology . (ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement. (iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iv) Contarctor has to fill pure back fill compound 250 mm all around the earth electrode up to full depth of pit. (v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item. (vi) Contarctor shall submit the test report of earthing after satisfactorily completion. (vii) Contractor shall bring agriculture soil from out side defence land and fill in earth pit . (viii) If hard rock strata found on site of earthing then earth electrode to placed by drilling a bore of 200 mm dia and 3.5 mtr depth and filling the conductolite back fill compound all around the electrode in bore without any extra cost. No extra cost for drilling bore will be paid by department. (ix) The cost of earthing includes supply and fixing earth strip of 20X3mm up to 7.5 RM from electrodes.
M & L for copper earth contInuity conductor of size 20 x 3 mm strip with insulator fixed to wall (porcelin insulater 10 BM heavy duty, ceramic bus bar support insulator off white colour of min size of 50 mm width x 70 mm length with 50 mm width bus bar mounting base) for fixing strip or drawn in conduit/pipe as required all as directed by Engineer In charge including taking down old GI rusted strip complete all as directed. Note: Insulator to be fixed on every 50cm distance and cost of insulator is deemed to be included in unit rate of item.
S&F for Test point junction box made of polycarbonate without terminal block 130x180x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation including taking down old u/s complete all as directed by EIC. Make : Hensel- Cat Part No. KF 01000 H
S & F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and as directed.
M&L taking down existing serviceable flame proof exhaust fan any type and wattage from existing location and fixing to new location including connecting fan to power supply point by providing PVC sheathed copper conductor wire 1.5 sqm X 3 core including cutting and openinig in wall of any type with and including making good of disturbed surfaces to match with as per existing specification complete all as directed
SUMAN CONSTRUCTION
NATIONAL CONSTRUCTION CO
M/s Antara
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .