Loading…
Loading…
| # | Company | Amount | Rank |
|---|---|---|---|
| 1 | L1₹1.2 Cr | ₹1.2 Cr | L1 |
| 2 | L2₹1.3 Cr+₹6.7 L (5.47%) | ₹1.3 Cr+₹6.7 L (5.47%) | L2 |
| 3 | L3₹1.3 Cr+₹7.4 L (6.08%) | ₹1.3 Cr+₹7.4 L (6.08%) | L3 |
| 4 | L4₹1.3 Cr+₹11.5 L (9.44%) | ₹1.3 Cr+₹11.5 L (9.44%) | L4 |
Tender Value
₹1.4 Cr
EMD Value
₹1.0 L
Closing Date
9 Jun 2026, 5:30 pmClosed
MR SE DURG 3 KUSUM DEWANGAN
CE,DURG
CONSTRUCTION OF PROPOSED REST HOUSE BUILDING INCLUDING ELECTRIFICATION WORK, AT PANDARIYA
191402
NIT NO. 67/Durg(Kawardha)/2026
RESTRICTED TENDER
WORKS
PERCENTAGE
CE
Required Past Technical Experience: As Per NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
5 documents required · 5 mandatory
Public Works Department (PWD)
WORKS
MR SE DURG 3 KUSUM DEWANGAN
RESTRICTED TENDER
PERCENTAGE
A B C
CE,DURG
DURG,CIRCLE
DIVISION KAWARDHA
120
No
1
7137000
12012023
191402
9 Jun, 2026 5:30:38 PM IST
12 Jun, 2026 11:30:14 AM IST
21 May, 2026 7:30:24 PM IST
15052026
NIT NO. 67/Durg(Kawardha)/2026
CONSTRUCTION OF PROPOSED REST HOUSE BUILDING INCLUDING ELECTRIFICATION WORK, AT PANDARIYA
103500.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
13754000.00
2
11 Jun, 2026 5:30:02 PM IST
13754000
AS PER NIT
AS PER NIT
As Per NIT
0.00 INR
09
18d 22h 12m
4910520230005 ,4910520230006 ,4910520230007
5 documents required · 5 mandatory
₹0
₹1.0 L
9 Jun 2026
21 May 2026
12 Jun 2026
21 May 2026
9 Jun 2026
21 May 2026
11 Jun 2026
NIT SCHEDULE FOR CONSTRUCTION OF PROPOSED REST HOUSE BUILDING INCLUDING ELECTRIFICATION WORK, AT PANDARIYA DISTRICT-KABIRDHAM
P.A.C. Rs. 137.54 Lacs
S. No. Chapter Item No. Sub Item No. Particulars Qty. Unit Rate Amount Amount in Words
1 1 1.1 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils. 907.57 cum 185.00 167900.45
2 1 1.6 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils 161.76 cum 26.50 4286.64
3 3 3.1 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 119.37 cum 2970.00 354528.9
4 3 3.2 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 391.25 cum 4163 1628752.935
5 3 3.4 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 218.56 cum 97.50 21309.1125
6 2 2.1 2.1.1 (A) Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 892.96 SQM 139.00 124121.44
7 2 2.1 2.1.5 (B) Columns, Pillars, Piers and likes- rectangular or square in shape 708.54 SQM 297.00 210436.38
8 2 2.1 2.1.8 (C) Beams, lintels, cantilevers & walls 323.70 SQM 202.00 65387.4
9 2 2.1 2.1.7 (D) Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) 923.54 SQM 235.00 217031.9
10 3 3.12 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415 35129.64 Kg 54.50 1914565.38
11 3.12.2 Thermo-Mechanically treated bars FE 500D 1938.00 kg 54.50 105621
12 1 1.18 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. 535.28 cum 371.00 198588.88
13 1 1.17 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. 711.88 cum 65.00 46272.2
14 3 3.13 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. 1.82 cum 4237.00 7711.34
15 3 3.15 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 36.56 Sqm 93.50 3418.36
16 7 7.5 7.5.4 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand) 354.36 cum 3263.00 1156276.68
17 7 7.6 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 326.62 cum 121.00 39521.02
18 8 8.1 8.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. Sal, bijasal, benteak, khair, haldu 1.03 cum 61051 62882.53
19 8 8.16 8.16.1 Providing and fixing PVC membrane foil coated (laminated) flush door shutters, made with core of block board with frame of first class hard wood, coated with 0.30mm membrane pasted with resin using vacuam treatment process complete all but excluding hinges. 35 mm thick (single leaf) 45.99 sqm 1982 91152.18
20 9 9.15 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. 612.00 kg 67.50 41310
21 9 9.47 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). 143.82 kg 338.00 48611.16
23 9 9.48 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. 287.64 kg 27.00 7766.28
24 9 9.5 9.50.1 Providing and fixing 12mm thick pre-laminated particle board flat pressed with decorative lamination and balancing lamination on specified sides exterior Grade – I MDF Board 12 mm thick confirming to IS:14587, including fixed in aluminium doors, windows shutters and partition frames with C.P. brass/ stainless steel screws etc. complete. With decorative lamination on one side and balancing lamination on other side. 38.16 sqm 845.00 32245.2
25 9 9.34 9.34 Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete. 17.67 sqm 791.00 13976.97
26 9 9.38 9.38 Providing and fixing broken glass 100 mm high in spacing not more than 40 mm both ways and laid in 50 mm thick (average) cement mortar 1:4 (1 cement : 4 coarse sand ) over compound walls, prapet walls and the like. 29.20 meter 268.00 7825.6
27 8 8.3 8.3 Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm. 138.00 each 72.50 10005
28 8 8.77 8.77.1 Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete: 125x85x5.50mm (Heavy Type) 84.00 each 256.00 21504
29 8 8.78 8.78.3 Providing and fixing antique/ SS finished brass parliamentary hinges with antique/ SS polished MS screw complete: 100x125x27x5 mm 42.00 each 300.00 12600
30 8 8.79 8.79.1 Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16mm 42.00 each 496.00 20832
32 8 8.81 8.81.1 Providing and fixing antique/ SS finished brass tower bolts (Barrel type) with antique/ SS polished MS screw complete: 250 x10 mm 42.00 each 297.00 12474
33 8 8.84 8.84.1 Providing and fixing antique/ SS finished brass handles with antique/ SS polished MS screw complete: 125 mm 50.00 each 58.50 2925
34 10 10.49 10.49 Providing and fixing ISI Marked designer tiles of approved design and size confirming to IS: 13801 over and including 20mm thick cement plaster 1:3 including floating coat of cement slurry on bed and filling joints with neat cement slurry mixed with pigment to match the shade of tiles complete. 65.60 sqm 1002 65731.2
35 10 10.69 ammendement Item 10.69 ammendement Item Providing and tiking false ceil'ng at all heights with 15 mm thick integral densified tegular e‹lged Iight weight calcium silicate false ceiling tile reinforced with fiber and natural filler false ceiling tiles of Size 595x595 MM of approved lcxture, design and patterns (such as cosmos, spinton,quatra.'foolb) having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:19B7, Light reflectance of 85% (minirrlum). Now combustible as per BS:476 (part- 4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.048 to 0.050 W/m0KC as per ASTM 518:1991, Weight 1 .900 Kg to 2.100 Kg per tile,15 MM Edge Density Having 450 Kg/cum & 10 MM Central portion of tile having 350 Kg/cum. in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized@ 120 grams per sqm including both sides) comprising of mainT runners of size 24x38 mm of length 3000 fnm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (ga Ivanizing @ 80 grams per sqm) i.e. 40 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length & L-shape level adjuster of size85w5x25winrn. Galvaniscd iron pcrimcr wall angle ol’ size24x24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.Sscrews.The work shall be carried out as per specifications, engineer in charge. ceiling height upto 3.50m from adjacent floor level extra height to e paid seperately) 288.68 sqm 1458.00 420895.44
36 12 12.7 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm 31.92 sqm 587.00 18737.04
38 12 12.9 12.9.1 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size above 300x300mm 4.80 sqm 692.00 3321.6
40 12 12.76 Ammt -No.04 Dt 4.05.18 12.76.3 Providing and laying vitrified floor tiles with digital print of random design with water absorption less than 0.05% and conforming to IS : 15622-2017 of 1st quality approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 1000x1000mm 368.79 sqm 1514.00 558348.06
41 12 12.45 12.45.3 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) Granite stone lakha red/ shahi red 94.35 sqm 4200.00 396270
42 12 12.46 12.46.1 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). Granite stone grey/pink 12.60 sqm 1869.00 23549.4
43 11 11.1 11.1.2 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand) 490.08 sqm 87.00 42636.96
44 11 11.2 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) 2230.09 sqm 91.50 204053.235
45 11 11.3 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) 2037.84 sqm 107.00 218048.88
46 14 14.56 14.56 Providing and applying 2mm thick white cement based polymeric Extcrior grade Putty with minimum 3 coats applied @4.5 kg/ 1 0Sqm as pcr relevant IS code 7545:2021 (Product such a.s Birl a wall care, Asian tarctor,,J K wall putty, Berger Bison wall putty) to make the Surface smooth and cvcn with a11 tool s tack lcs ariel 1abour etc. complete for the work. . 2219.79 sqm 86.00 190901.94
47 14 14.61 14.61 Providing and applying Synthatic oil bound washable Disterriper having VOC content less than 5Ogms/ lit. Maximum two coats up to final finish to give an even shade applied I .25 kg / 1 0Sqm as per relevant I S Code 428:2000 (product such as Asian Tractor synthatic distemper , Berger Bison Site , Dulux Magik , Birla Opus Style super smart) inclusive of providing abro tape on edges and article and cleaning Of door, windows, floor and surface as required with all tnols taekl es and labour etc. complete for the work. 283.40 sqm 57.00 16153.8
48 14 14.65 amm.08 5.5.25 14.65 amm.08 5.5.26 Providing & Applying Luxury Plastic emulsion pain with roller appliction minimum three coats applied @1.25 lit/10sqm upto final finish as per relevant Type 1 Class D,C,B & A (glossy/semiglossy and matt,Egg,Asian,Royal shyne,Dulux velvet Touc Berger silk Luxury Emulsion, Nippon imppression pearl,opus pure elegance) inlusive of providing abro tape on edge and article and cleaning of door,window,floor and surface as required with all tool tackles ad labour etc. complete for the work(with 4 years Waranty) 1385.39 sqm 107.00 148236.73
49 14 14.69 amm.08 5.5.25 14.69 amm.08 5.5.26 Providing & applying exterior surface with PREMIUM HEAVY DUTY Glossy or Matt Finish Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coat [email protected] li &/10sqm up to finila finish as per relevant IS Code 15489:2013 Type-2 Class D,C B & A(Glossy matt//Egg shell finish having high DFT and siliccon adisive for eastomaric property (product such as Asian ultima, Dulux, weathershield Maxx, Berger Weathercoat. All Guard, nerolac Excel Total, Nippon Durafresh Expert, Opus ru and cleaning of door, window , floor and surface as required with all tool tackles and labour etc. complete for the work (with 4 years waranty) qnty same as 15mm thick plaster 805.18 sqm 110.00 88569.8
50 9 9.57 9.57.1 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 204 106.80 kg 467.00 49875.6
51 14 14.72 14.72 Providing and applying glossy finish Enamel paint minimum 2 coats in nll surface applying 0.75 lit/ 10 Sqm up to required finish as per reinvent I.S. code *9S2‘ 2O 1 3 of (Product such as Asian Apcolite l*rcniium Enamel , Dulux Promise Premium Enamel . Neroloc Synthetic Enamel. Opus Prime enamel ) inclusive of providing nbro tape on edges and article and cleaning of door, windows, floor rind surface as required with all tools trickle end lnbour etc. complete ror the work. 148.10 sqm 120.00 17772
52 14 14.78 14.78 Providing and applying FRENCH SPIRIT POLISH on new wood work after preparing the surface by rubbing down sooth with sand papers. Covering the knots, if visible applyig a ccoat of wood filler, leaning the surface applying various (Minimum 4 coats) of french spirit polish @0.35Liter/sqm till the surface gives high goss. inclusive of providing abro tape on edges and artile and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work. 36.09 sqm 454.00 16384.86
53 SANITARY INSTALLATIONS
54 18 18.1 18.1.3 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Orissa pattern W.C. pan of size 580x440 mm 2.00 each 2899.00 5798
55 18 18.4 18.4.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : Coloured wall hung type 4.00 each 5967.00 23868
56 18 18.17 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm 6.00 each 1430.00 8580
57 18 18.21 18.21.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 1145x510 mm bowl size 560x410x241 mm 2.00 each 11767.00 23534
58 18 18.22 18.22.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 560x410 mm bowl depth 215 mm. 2.00 each 6210.00 12420
59 18 18.30 18.30.1 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 5mm thick mirror 4.32 sqm 2016.00 8709.12
60 18 18.31 18.31 Providing and fixing 600x120x5mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 4.00 each 272.00 1088
61 18 18.76 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe. 170.80 metre 182.00 31085.6
63 18 18.77 18.77.1 (18.77.1.1) Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm 50.00 each 113.00 5650
69 18 18.78 18.78.1 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm 48.00 each 57.00 2736
71 19 19.4 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 15 mm dia. nominal bore 36.00 metre 110.00 3960
72 19 19.4 19.4.2 20 mm dia. nominal bore 36.00 metre 151.00 5436
73 19 19.4 19.4.3 25 mm dia. nominal bore 114.00 metre 199.00 22686
74 19 19.4 19.4.4 32 mm dia. nominal bore 36.00 metre 271.00 9756
75 19 19.4 19.4.5 40 mm dia. nominal bore 24.00 metre 362.00 8688
76 19 19.5 19.5.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge CONCEALED WORK including cutting chases and making good the walls etc., 15 mm dia. nominal bore 32.00 metre 133.00 4256
77 19 19.5 19.5.2 20 mm dia. nominal bore 9.60 metre 167.00 1603.2
78 19 19.5 19.5.3 25 mm dia. nominal bore 9.60 metre 213.00 2044.8
79 19 19.7 19.7.1 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 15 mm dia. nominal bore 24.80 meter 149.00 3695.2
80 19 19.7 19.7.3 25 mm dia. nominal bore 50.00 meter 258.00 12900
81 19 19.8 19.8.1 Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete: 15 mm dia nominal bore 20.00 meter 188.00 3760
82 19 19.8 19.8.3 25 mm dia nominal bore 10.00 meter 297.00 2970
83 19 19.9 19.9.4 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete: 32 mm dia. nominal bore 180.00 meter 272.00 48960
84 19 19.10 19.10.1 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 25 mm dia. nominal bore 4.00 each 200.00 800
85 19 19.10 19.10.2 32 mm dia. nominal bore 14.00 each 224.00 3136
86 19 19.10 19.10.3 40 mm dia. nominal bore 2.00 each 278.00 556
87 19 19.11 19.11.1 Providing and fixing G.I. Union in G.I. pipe (New work) including cutting and threading the pipe and making long screws etc. complete: 15 mm nominal bore 2.00 meter 85.00 170
88 19 19.11 19.11.2 20 mm nominal bore 2.00 meter 98.00 196
89 19 19.11 19.11.3 25 mm nominal bore 8.00 meter 117.00 936
91 19 19.13 19.13.1 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (350 grams) 6.00 each 185 1110
93 19 19.14 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) 8.00 each 382.00 3056
94 19 19.14 19.14.2 Long nose bib cock (500 grams) 2.00 each 455.00 910
95 19 19.14 19.14.3 Long body bib cock (500 grams) 12.00 each 426.00 5112
96 19 19.14 19.14.6 Stop cock (concealed) (600 grams) 4.00 each 494.00 1976
97 19 19.14 19.14.7 Angle valve for basin mixer and geyser points (450 grams) 4.00 each 382.00 1528
99 19 19.14 19.14.15 Shower rose (revolving type) (150mm) 6.00 each 269.00 1614
100 19 19.14 19.14.16 Towel rail (600mm long x 20mm dia) 7.00 each 338.00 2366
101 19 19.15 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 8.00 each 51.00 408
102 19 19.16 19.16.1 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore 6.00 each 436.00 2616
105 19 19.17 19.17.1 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore 2.00 each 284.00 568
108 19 19.42 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 5000.00 litre 7.30 36500
109 19 19.43 19.43 Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same : 20.00 each 125.00 2500
110 19 19.44 19.44 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. 20.00 each 94.00 1880
111 19 19.47 19.47 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : 8.00 each 754.00 6032
112 20 20.6 20.6.1 Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN 6 for sewer application as per IS 14333-1996 (amended upto date) in trenches in complete including all material, labour, testing and commissioning as per direction of Engineer. 100 mm dia 84.00 metre 366.00 30744
114 20 20.1 20.1.1 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 100 mm diameter S.W. pipe 84.00 metre 162.00 13608
115 20 20.1 20.1.2 150 mm diameter S.W. pipe 110.00 metre 262.00 28820
116 20 20.2 20.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. pipe 50.00 each 436.00 21800
117 20 20.3 20.3.1 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type 14.00 each 1339 18746
118 20 20.7 20.7.1 Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 2.00 each 6703 13406
119 20 20.7 20.7.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 2.00 each 14448 28896
120 20 20.7 20.7.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 2.00 each 18977 37954
121 20 20.28 20.28.1 Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 4.00 each 3796.00 15184
122 20 20.30 20.30.1 Providing and constructing brick work for extra depth beyond 45 cm of brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) with inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls: For 455x610 mm size 1.20 each 2616 3139.2
125 20 20.31 20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. 2.00 each 1709.00 3418
126 20 20.51 20.51 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. 4.00 each 1709 6836
127 3 3.14 3.14 Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer. 67.23 kg 43.50 2924.505
128 1 1.2 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). 804.00 sqm 7.20 5788.8
129 7 7.11 7.11.2 Half brick thick honey comb brick work with modular well burnt clay bricks of crushing strength not less than 25 kg/sqcm and water absorption not more than 20% upto plinth level. Cement Mortar 1:4 (1 cement : 4 coarse sand) 52.94 sqm 382.00 20223.08
130 7 7.20 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. 52.94 sqm 62.50 3308.75
131 9 9.18 9.18.9 Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets conforming to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer. Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet. 115.40 meter 474.00 54699.6
132 8 8.14 8.14.3 Providing and fixing flush door shutters, core of block board construction with frame of first class hard wood and well matched first class Indian teak ply veneering on one face and commercial ply veneering on the other face of the shutter with vertical grains, cross bands and face veneering excluding hinges. 30 mm. thick (single leaf) 22.26 sqm 1514.00 33701.64
133 8 8.148 8.148.2 Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge Extruded section Profile size 42x50 mm. 20.00 meter 196.00 3920
134 8 8.150 8.150 Providing and fixing factory made 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25mm or less as per requirement with an average wall thickness of 1mm ± 0.3mm. PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. An M.S. tube having dimensions 19mm x 19mm is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufactures' specification. 6.72 meter 2583.00 17357.76
135 9 9.12 9.12 Providing and fixing sliding shutter with M.S. sheet 1mm thick, frame and diagonal braces of 40x40x6mm angle iron, 3.0 mm thick M.S. gusset plates at junctions and corners, 25mm dia pulley, 40x40x6mm angle and T-iron guide at top and bottom respectively including applying a priming coat of red oxide zinc chromate primer. 558.60 kg 71.50 39939.9
136 8 8.120 8.120.1 Providing and fixing aluminium sliding door bolts with 16mm rod, necessary nickel plated iron nuts bolts and screws etc complete. 300x16mm 16.00 each 169.00 2704
137 8 8.121 8.121.2 Providing and fixing aluminium door latch with 12mm rod, necessary nickel plated iron nuts bolts and screws etc complete. 250x12mm 8.00 each 169.00 1352
138 8 8.122 8.122.2 Providing and fixing aluminium tower bolts (Barrel type) with necessary nickel plated iron screws etc complete. 200 x10mm 8.00 each 57.50 460
140 8 8.123 8.123.2 Providing and fixing aluminium door handles 2.5mm thick with necessary nickel plated iron screws etc complete. 125 mm 40.00 each 26.00 1040
141 8 8.124 8.124.2 Providing and fixing aluminium door mounted door stopper with necessary nickel plated iron screws etc complete. 75 mm long 12.00 each 37.00 444
142 12 12.3 12.3.2 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50 mm thick 129.04 sqm 254.00 32776.16
143 13 13.3 13.3.5 15 mm thick Marble work (machine cut, table rubbed & polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Udaipur green marble 3.46 sqm 1808.00 6255.68
144 21 21.17 21.17 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) 1.00 each 1502.00 1502
145 21 21.1 21.1.1.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. 150 mm dia. 20.00 meter 339.00 6780
147 21 21.2 21.2.2 21.2.2.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 150 mm dia. 40.00 meter 424.00 16960
148 21 21.3 21.3.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. 20.00 meter 540.00 10800
149 21 21.11 21.11.3 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia 1.00 each 217.00 217
150 21 21.12 21.12.3 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm dia 1.00 each 1055.00 1055
151 3 3.12 Road Sor 3.12 Road Sor Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/selected soil having C.B.R.>5 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) 191.25 cum 223.00 42648.75
152 4 4.1 4.1 A, B (i) Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) For Sub-base cum drainage layer or upper sub-base with Grading-V Material 108.00 cum 1372.00 148176
153 6 6.6 6.6 Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) P.C.C. M-10 cc road Base 46.80 cum 2789.00 130525.2
154 6 6.7 6.7 Providing and laying Un-reinforced Cement Cocrrte. Without. Dowel bars including formwork and expansion, contraction & longitudinal joints as per desing and as per IRC-62-2014, over a prepared base a per approved mix desing and finishing to jines and grade as per Drawing for Pavement thickness less than 200mm in Low Volume roads. PCC Grade M-30 with minimum cement content @ 375 kg/cum. 67.50 cum 4391.00 296392.5
155 4 4.15 4.15 A Providing & laying precast interlocking concrete blocks of minimum compressive strength of 300 kg/sq.cm and approved size , shape/ pattern over coarse sand bed of thickness upto 40 mm and joints thick filled with fine sand including leveling with surface vibrator, temping and sweeping etc. complete as per IRC-SP-63-2004. 60mm thick Plain precast interlock concrete block 270.00 sqm 497.00 134190
156 3 3.20 3.20 (ii) Construction of RCC open drain Construction of RCC open drain 0.60m x 0.60m insidedimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications. 140.00 meter 2592.00 362880
157 3 3.25 3.25 (ii) Construction of RCC Drain/Cover/Chamber Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20 10.08 cum 4146.00 41791.68
158 3 3.25 (iii) Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/ chamber complete as per Drawing and Technical Specifications. 0.40 Mtr 56301.00 22689.303
159 9 9.4 9.4 (A) Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets). 450 mm dia 10.00 meter 1893.00 18930
160 22 22.1 22.1 Trenching in ordinary soil upto a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 140.00 cum 115.00 16100
161 22 22.2 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). 84.00 cum 201.00 16884
162 22 22.4 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). 56.00 cum 236.00 13216
163 22 22.8 22.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). 210.00 cum 17.50 3675
164 22 22.9 22.9 Mixing earth and sludge or manure in proportion specified or directed. 210.00 cum 11.00 2310
165 22 22.25 22.25.2 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Furn like Arica, China etc (3 year old) 70.00 each 125.00 8750
166 22 22.25 22.25.3 Hibiscus (Flower)/ Rose 200.00 each 26.50 5300
167 22 22.25 22.25.4 Carpet grass (well developed) 300.00 each 263.00 78900
168 19 19.6 19.6.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge. 32 mm nominal outer dia pipes 110.00 meter 228.00 25080
169 9 9.14 9.14 Providing and fixing steel door made of angle iron of suitable sizes with M.S. grill of approved pattern made of M.S. flats or square or round bars coat of red oxide zinc chromate primer. 800.10 kg 79.50 63607.95
170 9 9.3 9.3.1 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-250 97.20 kg 88.50 8602.2
171 14 14.66 14.66 Providirlg and applying on exterior surrace with LITE ECONOMY Exterior Emulsion paint of required ShadCS tO give protective and water proof finiSir lTiinimum thrcc GOats applied 1.43 lit / 10Sqm up to final finish as per rclcvant I.S Code 15489-2013 Type -2 Class D , C ( Glossy /Semi Glossy finish ) (Product sucli as Asian ACE Spark ,Dulux Porriise exterior smart, Nerolac Littil Master, Berser Bison Lite, Nippon Superio etc) incIusivc of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the woric (With 2 Year Warranty.) 1786.44 sqm 55.00 98254.2 11754285.00
172 1 1.7 1.7.1 Wiring for light/ fan/exhaust fan /call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point 25 Point 266.00 6650.00 Electrical Items Start
173 1 1.7 1.7.2 Medium Point 30 Point 424.00 12720.00
175 1 1.9 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 66 Point 216.00 14256.00
176 1 1.11 1.11.2 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point 2 Point 942.00 1884.00
178 1 1.11 1.11.4 Extra Long Point I 4 Point 1807.00 7228.00
179 1 1.11 1.11.5 Extra Long Point II 4 Point 2315.00 9260.00
180 1 1.11 1.11.6 Extra Long Point III 2 Point 2825.00 5650.00
181 1 1.12 1.12.3 Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point 4 Point 1705.00 6820.00
182 1 1.12 1.12.4 Extra Long Point I 6 Point 2326.00 13956.00
183 1 1.12 1.12.5 Extra Long Point II 4 Point 3016.00 12064.00
184 1 1.12 1.12.6 Extra Long Point III 2 Point 3708.00 7416.00
185 1 1.13 1.13.1 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit 180 Metre 92.00 16560.00
190 1 1.13 1.13.6 3 X 4 sq. mm in 25mm conduit 15 Metre 145.00 2175.00
191 1 1.13 1.13.7 3 X 6 sq. mm in 25mm conduit 15 Metre 182.00 2730.00
192 1 1.15 1.15.1 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 20 mm 95 Metre 42.00 3990.00
193 3 3.11 3.11.1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 1 x 1.5 sq. mm 255 Metre 15.00 3825.00
194 5 5.4 5.4.9 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (two module size) electronic stepped type moving all rounds 27 Each 223.00 6021.00
195 5 5.4 5.4.20 Ceiling rose 3 pin 5 amp 96 Each 40.00 3840.00
196 5 5.4 5.4.22 Batten/angle holder 23 Each 41.00 943.00
197 5 5.4 5.4.23 Blanking plate 50 Each 28.00 1400.00
198 5 5.10 5.10 Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification. 27 Each 109.00 2943.00
199 6 6.1 6.1.3 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 1200 mm sweep 4 Each 1697.00 6788.00
200 6 6.2 6.2.2 Supplying, installation, testing and commissioning of premium quality Decorative ceiling fan having modern designer blades, good airthrow and with atleast two colour rendering effect along with unique smooth flowing canopies and down rod sleeve covering, wider blades at tips giving conical air throw including remote control for following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire, earthing etc. complete as per specification. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments 1200 mm sweep 23 Each 2092.00 48116.00
201 6 6.3 6.3.1 Supplying, installation, testing and commissioning of following sizes Pedestal fan with telescopic arrangement for height adjustment and standard wiring/connection etc complete as per specification. P.F. should be greater than 0.9 400 mm sweep 2 Each 2391.00 4782.00
202 6 6.6 6.6.1 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 300 mm sweep 3 Each 2446.00 7338.00
203 6 6.8 6.8.2 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 300 mm sweep 6 Each 1270.00 7620.00
204 6 6.11 6.11.3 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 90 cm long 27 Each 58.00 1566.00
205 6 6.16 6.16.1 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 24 watt, size 300 x 300mm 52 Each 1775.00 92300.00
206 6 6.19 6.19.3 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet} 22 Each 443.00 9746.00
207 6 6.20 6.20.2 Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 12 Watt 20 Each 546.00 10920.00
208 6 6.21 6.21.1 Supplying, installation, testing and commissioning of following LED tube light fitting {Inverter Type: with builtin battery backup} including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification. IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 20 watt 20 Each 997.00 19940.00
209 6 6.28 6.28.6 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 45 watt 2 Each 2729.00 5458.00
212 6 6.58 6.58 Supplying, installation, testing and commissioning of Acrylic LED light (a) Specification of Acrylic 3 mm thick x 3 " width x 4 " depth *(imbose) (b) Specification of LED modules :- Each Moduel should have 6 Nos LED of 1 watt 25 SQFT 2312.00 57800.00
213 6 6.59 6.59 Supply and installation of timer including relay and contactor set complete as required. 1 Each 3929.00 3929.00
214 6 6.60 6.60 Supplying and installation of SMPS (water proof) for power supply AC input 110/220 V 50/60HZ DC output 12V 30A 1 Each 5229.00 5229.00
215 6 6.61 6.61 Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification 80 KG 66.00 5280.00
216 7 7.11 7.11.5 Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 200 amps 3 Each 544.00 1632.00
217 7 7.18 7.18.3 Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 40x5mm (300 amps) 5 Each 465.00 2325.00
218 7 7.19 7.19.1 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Upto 300 mm deep 1.3 sqm 6818.00 8863.40
219 7 7.20 7.20.3 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 300 amp (50x5mm) 4 Metre 1336.00 5344.00
220 9 9.1 9.1.24 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA 6 Each 6378.00 38268.00
221 9 9.1 9.1.34 4 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 50KA 1 Each 16978.00 16978.00
222 9 9.7 9.7.2 Supplying and fixing on surface/ recess prewired following way, 240 volts SP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 2 + 8 way, Single door 2 Each 1928.00 3856.00
223 9 9.8 9.8.5 Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 4 way (4 + 12), Double door 5 Each 5904.00 29520.00
224 9 9.11 9.11.2 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps 80 Each 148.00 11840.00
225 9 9.19 9.19.2 Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps 2 Each 264.00 528.00
226 9 9.20 9.20.2 Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps 5 Each 621.00 3105.00
227 10 10.7 10.7.3 Providing and fixing metal clad, 4 pole, on load change over switch unit (with sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately) 200 amps 1 Each 11772.00 11772.00
228 10 10.13 10.13.5 Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 200 amps 3 Each 10884.00 32652.00
229 10 10.17 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. 6 Each 94.00 564.00
230 10 10.21 10.21.1 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification. For voltmeter 1 Each 189.00 189.00
232 10 10.23 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. 1 Each 1201.00 1201.00
233 11 11.3 11.3.3 Supplying, installation, testing and commissioning following rating single phase 230 volts sine wave inverter (without battery) including connection as per specification. 1.50 KVA 1 Each 5504.00 5504.00
234 11 11.4 11.4.5 Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 150 AH 4 Each 14252.00 57008.00
235 12 12.3 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) 5 Set 6209.00 31045.00
236 12 12.10 12.10 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification. 20 Metre 53.00 1060.00
237 12 12.20 12.20 Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres 10 Cum 168.00 1680.00
238 13 13.1 13.1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate having 4 nos holes for fixing etc. complete as per specification. 1 Each 767.00 767.00
239 13 13.6 13.6 Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as per specification. 25 Metre 654.00 16350.00
240 14 14.2 14.2.1 Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia 105 Metre 124.00 13020.00
241 14 14.3 14.3.1 Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 50 mm internal dia 15 Metre 333.00 4995.00
242 14 14.3 14.3.2 80 mm internal dia 5 Metre 527.00 2635.00
243 15 15.3 15.3.11 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 25 sq. mm. 290 Metre 117.00 33930.00
244 15 15.5 15.5.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 2 x 10 sq. mm 95 Metre 106.00 10070.00
245 15 15.6 15.6.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 25x3 mm M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification , IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 95 sq. mm. 50 Metre 384.00 19200.00
246 23 23.3 23.3.4 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3.0 HP, three phase 1 Each 22714.00 22714.00
247 23 23.5 23.5.1 Supplying and fixing of following sizes 'B' class G I pipe with all necessary Tee's, bends, sockets in the suction/ delivery line including cutting and threading etc. as per specification. 100 mm dia. 20 Metre 1064.00 21280.00
248 23 23.6 23.6.2 Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 50 mm outer dia 100 Metre 118.00 11800.00
249 23 23.7 23.7.1 Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 100 mm dia. 2 Each 5358.00 10716.00
250 23 23.11 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set 1 Each 4030.00 4030.00
251 23 23.14 23.14.3 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3x4.0 sqmm 120 Metre 90.00 10800.00
252 24 24.3 24.3.3 Supplying of approved make split type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 3 metre of copper piping with insulation, etc complete as per specification: 2.0 ton split type capacity 6000 kcal / hr (3 star). 8 Each 48012.00 384096.00
253 24 24.4 24.4 Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis) 8 Each 2110.00 16880.00
254 24 24.7 24.7.2 Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification. 5 KVA 8 Each 4367.00 34936.00
255 24 24.11 24.11 Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification 8 Set 435.00 3480.00
256 24 24.21 24.21.1 Supplying, installation, testing and commissiong of following size {storage volume } domestic refrigarator with BEE star rating,copper coil and eco friendly refrigerant, suitable puff insulation, built in voltage stabilizer and power saver compressor, conformity to IS: 1476, including all accessories connection etc complete as per specification. 190 ltr. 2 Each 14517.00 29034.00
257 24 24.23 24.23.3 Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 150/150 Ltrs/hr 1 Each 47568 47568.00
258 24 24.24 24.24.1 Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification. 25 Ltrs/hr output capacity 1 Each 23508.00 23508.00
259 24 24.26 24.26.8 Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 15 Ltr. Capacity storage type geyser 5 star 4 Each 6648.00 26592.00
260 24 24.27 24.27 Installation, testing and commissioning of wall mounted storage type electric geyser including inlet / outlet water pipe connection, electric connection etc. as per specification. 4 Each 190.00 760.00
261 24 24.33 24.33 Supply, Installation , testing and commisioning of 5000 Cubic meter per hour Jumbo Plastic Body Cooler Including Floor Standing caster wheels ,Synthetic Honeycomb pads , Sump Tank Capacity (minimum) 100 Litres , minimum Thickness of Body of the Plastic Cooler should be 2 millimeter, Drain Plug material Plastic / Rubber,Fan Size 450 mm ,Blade Material High Impact Plastic , Minimum number of steps for fan speed control should be 3 , Power Factor 0.9 or Better,Thickness of Synthetic Honeycomb pads Filter should be 15 mm or above, Location of the Water Collecting Chamber At the Bottom , ,Minimum length of connecting cable with 3-pin moulded Plug Top 5/6 Amps rating should be 2.5 meter etc complete with all fitting accessorries and supports as required. 2 Each 14911.00 29822.00
262 24 24.35 24.35 Supply , Installation , testing and commissioning of 1800 Cubic meter per hour Nominal Air Delivery Window Air Cooler without caster wheels incuding Wood wool pads , Sump Tank Capacity (minimum) 36 Liters , Material of Filter panel, Grill,Top of cooler body, cabinet, sump tank should be of Galvanized steel sheet (ISI marked to IS 277 latest) with zinc coating not less than 100 gms/sq.meter ,Sheet Thickness (nominal) for Filter panel, Grill, Top of cooler body, cabinet - 0.8 mm , Sump Tank Sheet Thickness (nominal) 1.0 mm , All internal surfaces of Steel Body Cooler Painted with Water Resistant paint ,Drain Plug material Brass / SS Fan Size 380 mm , Minimum number of steps for fan speed control should be 3 , Power Factor 0.9 OR BETTER,Thickness of Filter Pad 15 mm or above Non-corrosive Wire Guard for Filter Pads,Location of the Water Collecting Chamber At the Bottom , Minimum length of connecting cable with 3-pin moulded Plug Top 5/6 Amps rating should be 2.5 meter etc complete with all fitting accessorries and supports as required. 1 Each 8618.00 8618.00
263 26 26.17 26.17.2 Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC Fire Extinguisher 6KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 4A, 144B. With all accessories. 2 Each 4550.00 9100.00
264 26 26.17 26.17.5 CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve 2 Each 8222.00 16444.00
265 27 27.49 27.49.2 Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 43 inch 2 Each 43178.00 86356.00
boq_comp_chart.xls
BOQ Comparative Chart • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.15 MB
8268409505478007114_191402_Affidavit.docx
NIT • 0.01 MB
1264083134299146774_191402_BID-CAPACITY-2.docx
NIT • 0.03 MB
2781029542975995601_191402_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7334175896905456603_191402_Latest A_ 2.doc
NIT • 0.16 MB
6726047163352879239_191402_Latest NIT APPENDIX 2.doc
NIT • 0.32 MB
7247465732570570996_191402_English Notice more than 1 Crore.docx
NIT • 0.03 MB
4849538725753854102_191402_NIT.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .