Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.8 LAdmitted-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L1 |
|---|---|---|---|---|
| 1.00 | Material & labour for servicing/overhauling , Calibration and decarbonising of 11 KV PIX panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 800/630 Amps, indoor/out door type , taking shut down from 33 KV MRS and taking out breaker from VCB panel and checking of auxillary supply and control voltage, Physical checking of gears, checking of fixed and moving contacts, checking of close and trip coil, cleaning the gear thoroughly, lubricating the gear if necessary, applying grease on required parts, painting by insulation paint if required, checking of spring charging motor/mechanism, checking of manual spring charging, physical check of wear and tear if any and rectification of the same, physical checking of epoxy housing, checking of control circuit and tighten the cinnections if any. Special attention is to be given for adjustment of the part/ assembly responsible for lower/raise and locking of the trolley including replacement of un-serviceable spares, greasing of revolving assembly and movable parts in VCB chamber, checking of all DC supply system, electrical circuit to make it functional all as specified and directed by Engr -in - charge. Make of VCB`s of which Serviceing and repairing has to be carry out is Schneider/Crompton/Alstom / Kirloskar
Note :- (i) : Spare parts/components required for replacement of above VCB`s shall be measured and paid separately.
(ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items
(iii) For item No. 2 to 35 below, fixing charges of items are considered and included in item No 1 herein.
(iv) Location of VCB`s is in Tech and Domestic area at AF stn KKD and DDK Range. | 6 | Each job | 30,000 ₹1,80,000 Lowest |
| 2.00 | Supply only micom P 127 Relay for Schneider VCB and as existing model in Cromton and Kisloskar make VCB`s. complete al as specified and as diretced.
Make :- Schneider | 2 | Each | 60,000 ₹1,20,000 Lowest |
| 3.00 | Supply only Isolating contact 630A Complete all as specified and as directed. Make - Schneider Cat No - MVIG00134-01 of Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 4 | Set of 12 | 4,800 ₹19,200 Lowest |
| 4.00 | Supply only Vacuum Interrupter Complete all as specified and as directed.
Make - Schneider Cat No. VG2 Cat No - DRCVG2002-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 3 | Set of 3 | 1,70,000 ₹5,10,000 Lowest |
| 5.00 | Supply only Closing coil 110V DC Complete all as specified and as directed. Make - Schneider Cat No. ECO27SN117900FN for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 4 | Each | 7,500 ₹30,000 Lowest |
| 6.00 | Supply only Triping Coil 110V DC Complete all as specified and as directed. Make - Schneider Cat No. ECO27SOG83800FN for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 4 | Each | 7,500 ₹30,000 Lowest |
| 7.00 | Supply only Breaker auxillary swtich 6 No + 6NC Complete all as specified and as directed. Make - Schneider Cat No -MVIE00114-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 4 | Each | 13,000 ₹52,000 Lowest |
| 8.00 | Supply only Motor cut off switch Complete all as specified and as directed. Make - Schneider Cat No - EVU27S0307600NA for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 4 | Each | 8,000 ₹32,000 Lowest |
| 9.00 | Supply only Trip Fork Linkage assembly Complete all as specified and as directed. Make - Schneider Cat No -MVIE00072-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 2 | Each | 14,000 ₹28,000 Lowest |
| 10.00 | Supply only Trip prop support Assembly. Complete all as specified and as directed. Make - Schneider Cat no- MVIE00023-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s. | 3 | Each | 9,000 ₹27,000 Lowest |
Tender Value
₹65.0 L
EMD Value
₹1.2 L
Closing Date
22 Nov 2025, 6:00 pmClosed
Shri Shirish Sharma, IDSE, SE (SAG)
CWE (AF) KALAIKUNDA
COMP MAINT REP REPLACEMENT AND MAINT OF 33 KV SWITCH YARD MRS AND POWER TRANSFORMERS WITH PERIODICAL SERVICES CALIBRATION OF 11 KV HT SWITCH GEARS OF VCB HT CABLES RMUS AND ALLIED WORKS AT 33 / 11 KV HT NETWORK AND MRS AND LIFT MECH LAUNDRY EOT CRANE
2025_MES_734108_1
8719/KKD/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
CWE AF KALAIKUNDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) KALAIKUNDA
₹1.2 L
Yes
5 Dec 2025
7 Oct 2025
24 Nov 2025
7 Oct 2025
22 Nov 2025
3 Nov 2025
Amount
Material & labour for servicing/overhauling , Calibration and decarbonising of 11 KV PIX panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 800/630 Amps, indoor/out door type , taking shut down from 33 KV MRS and taking out breaker from VCB panel and checking of auxillary supply and control voltage, Physical checking of gears, checking of fixed and moving contacts, checking of close and trip coil, cleaning the gear thoroughly, lubricating the gear if necessary, applying grease on required parts, painting by insulation paint if required, checking of spring charging motor/mechanism, checking of manual spring charging, physical check of wear and tear if any and rectification of the same, physical checking of epoxy housing, checking of control circuit and tighten the cinnections if any. Special attention is to be given for adjustment of the part/ assembly responsible for lower/raise and locking of the trolley including replacement of un-serviceable spares, greasing of revolving assembly and movable parts in VCB chamber, checking of all DC supply system, electrical circuit to make it functional all as specified and directed by Engr -in - charge. Make of VCB`s of which Serviceing and repairing has to be carry out is Schneider/Crompton/Alstom / Kirloskar Note :- (i) : Spare parts/components required for replacement of above VCB`s shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items (iii) For item No. 2 to 35 below, fixing charges of items are considered and included in item No 1 herein. (iv) Location of VCB`s is in Tech and Domestic area at AF stn KKD and DDK Range.
Supply only micom P 127 Relay for Schneider VCB and as existing model in Cromton and Kisloskar make VCB`s. complete al as specified and as diretced. Make :- Schneider
Supply only Isolating contact 630A Complete all as specified and as directed. Make - Schneider Cat No - MVIG00134-01 of Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Vacuum Interrupter Complete all as specified and as directed. Make - Schneider Cat No. VG2 Cat No - DRCVG2002-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Closing coil 110V DC Complete all as specified and as directed. Make - Schneider Cat No. ECO27SN117900FN for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Triping Coil 110V DC Complete all as specified and as directed. Make - Schneider Cat No. ECO27SOG83800FN for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Breaker auxillary swtich 6 No + 6NC Complete all as specified and as directed. Make - Schneider Cat No -MVIE00114-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Motor cut off switch Complete all as specified and as directed. Make - Schneider Cat No - EVU27S0307600NA for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Trip Fork Linkage assembly Complete all as specified and as directed. Make - Schneider Cat No -MVIE00072-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Trip prop support Assembly. Complete all as specified and as directed. Make - Schneider Cat no- MVIE00023-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Charging pawl complete all as specified and as directed. Make - Schneider Cat no MST27SSD28500BL_S for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Buffer for spring complete all as specified and as directed. Make - Schneider Cat no-MVIE00060-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Over ride stop complete all as specified and as directed. Make - Schneider Cat no- MVIE00013-09 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Over ride stop pin complete all as specified and as directed. Make - Schneider Cat no- MVIE00232-01 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar for Crompton /Kirloskar Make VCB`s
Supply only limit switch 4 terminal 10 Amps.
Supply only R Phase Bus Bar Spout Complete all as specified and as directed. Make - Schneider Cat no- MVIF00072-02 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Y Phase Bus Bar Spout complete all as specified and as directed. Make - Schneider Cat no- MVIF00070-02 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only B Phase Bus Bar Spout complete all as specified and as directed. Make - Schneider Cat no- MVIF00066-02 for Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only housing for VCB complete all as specified and directed by Engr- in - charge. Make: Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Top stem complete all as specified and directed by Engr- in - charge. Make: Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Bottom stem complete all as specified and directed by Engr- in - charge. Make: Schneider Make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Spring charging motor 110 volt complete all as specified and directed by Engr- in - charge. Make: Schneider Make VCB, Cat No. VDRE00100-01 or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only TNC switch complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only 24 Pin Plug & Socket assembly complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB, Cat No.MHU3950019000FN or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Pin for Ratchet complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB, Cat No.MVIE00079-01 or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only PLA relay, 110 volt DC, 8 pin complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB, or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only 110 volt DC contactor 1 NO+1NC complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB, or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Master trip relay, 110-125 V DC complete all as specified and directed by Engr- in - charge. Make: Alstom, Cat No. VAJH13YF0751BBA.
Supply only HG bolted HRC fuse 4 Amp 415 volt complete all as specified and directed by Engr- in - charge.
Supply only Indicator lamp (LED type) 24-240 V DC/AC Red colour complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Indicator lamp (LED type) 24-240 V DC/AC Green colour complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Indicator lamp (LED type) 24-240 V DC/AC Blue colour complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Indicator lamp (LED type) 24-240 V DC/AC White colour complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only Indicator lamp (LED type) 24-240 V DC/AC Clear/transparent colour complete all as specified and directed by Engr- in - charge. Make: Schneider make VCB or Equivalent model in Crompton /Kirloskar/ Alstom for Crompton /Kirloskar/ Alstom Make VCB`s.
Supply only spray Moisture absorbing spray WD-40 on electric terminals of VCB Breaker and panel and allied equipment all as specified and directed.
Supply & fixing LED type Multi function meter 3 phase, class 1.0, measuring the following parameters : V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Interrupts, THD complete all as specified. Make- Schneider, Cat No. EM6400NG - or equivalent.
Supply, replacement and topping up new Transformer oil EHV grade as per IS 335 of 1993 Part II having die electric strength not less than 40 KV in the Transformers at various location complete all as specified and direct by EIC. Make of Transformer oil : Transol/Power oil/any brand of Indian oil corporation). Note : Transformer oil should be heated and should having dielectic strength 60 KV (ii) Transformer oil shall be bring in sealed barrel having proper test certificate from manufacturer.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm- 185 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm- 95 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm- 95 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm- 185 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm- 400 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for Cable jointing kit for 33 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm- 240 Sqmm all as specified and directed incl taking down unsv one.
Material & labour for detecting of fault in 11KV (E) HT cable of any size, 3 core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & Jointing kit shall be measured & paid separately. (iii) As the work is releated to maintenance, the work of fault detection has to be carry out on Priority and on requirement basis as on occurance of fault within 24 hrs so as to rectify the fault and to restore the electric supply of stn. If contractor delay the job, necessary panlty at the rate of Rs 1000.00 per hrs (after 24 hrs) will be impose on contractor.
Supply, Install, testing and commissioning of 33 KV single phase outdoor type oil cooled ,dead tank type CT of ratio 160-80/5-5-1 Amp accuracy class 0.5 for metering equipment of burden 15 VA as per IS:2705 including connection CT terminal to control panel through control cable and taking down unsv one complete all as specified and directed. Make as per IS and Model/designed as per existing sample. Note: (i) Contractor has to make all arrangement for mounting/ placing CT`s in existing system without any extra cost.
Supply, install, testing and commissioning 33 KV single phase outdoor type oil cooled,dead tank type PT of ratio 33 KV /√3 : /110V/√3-110V/√3 ,accuracy class 0.5, Burden 150 VA conforming to IS:3156 including connection PT terminal to control panel through conntrol cable and taking down unsv one complete all as specified and directed. Make as per IS and Model/designed as per existing sample. Note: (i) Contractor has to make all arrangement for mounting/ placing PT`s in existing system without any extra cost.
Material & labour for 33 KV Air break switch (isolator) outdoor type, off load, Triple pole, double break, consisting of hot dip galvanized channel iron base, mechanically operated, mounted on HT insulator and steel frame, with operating mechanism, copper or copper alloy high pressure heavily tinned complete with horizontal connecting sq.bar, GI pipe as down rod, coupling for pipe, lever and operating handle with locking arrangement worked from ground level, for current rating upto 1250 amps complete all as specified and as directed. Make as per IS and Model/designed as per existing sample.
Supply & fixing, installation VRLA batteries of capacity 55 Nos x 2 volt DC, 300 AH, total output voltage 110 volt DC including standard accessories and rack arrangement complete all as specified. Make- Exide/Amaran powerstack.
Supply & fiixing, installation battery charger automatic float cum boost charger of capacity 110 volt, 50 Amp. Load & charging : 50 Amp, Input : 415 volt AC (Three phase), output : 110 volt DC, float output cutoff :124 volt DC, Boost output cutoff : 131 volt DC. Protection : High Cut/ Low Cut; Overload cut-off Deep Discharge cut-off, Over charging cutoff Automatic Voltage Regulation: 415V AC ± 10% complete all as specified.
Supply and installation of power packs with and including battery 12 V, 7AH backup for 11 KV VCB, input voltage 230 V AC, output 110 V DC complete all as specified.
Supply & fixing VRLA battery 12V, 7AH for 11 KV VCB power pack complete all as specified.
Supply & fixing VRLA battery 12V, 300AH for 11 KV VCB complete all as specified.
Supply & installation of 3 phase copper 11 KV/110 V indoor draw out type potential transformer (PT) of ratio 11KV/√3 /110V/√3/110V/√3, class 0.5, burden 50 VA-50VA complete all as specified.
Supply and installation of 11 KV single phase in door resin cast dual core CT of ratio 100-50A/5-5A, class 0.5, burden 15 VA, protection core 5P10 complete all as specified.
Repair & Maintenance of transformer of capacity 630 KVA , 11kV/433 volt outdoor type step down transformer following works :- (i) Fault detection and Draining out of existing traformer oil, opening and lifting of core and winding assembly by hydra/ hydraulic lifter complete from in side the transformer after un screwing all nuts bolts washers and cleaning old / used insulating oil (ii) Loading and unloading the core assembly including transportation charges upto MES switch yard to outside workshop and back. (iii) Dismantling damaged laminated sheet replacement of damaged wraping insulating paper over primary and secondary coil including total insulating material. complete connection of HV & LV side cable, in existing cable with new nut bolts, washer, PG clams, Pad clams etc as required at site should be entire satisfication of Engr in charge.
Materal and labour for re-insulation charges for coil complete all as directed by Engineer-in-Charge.
Materal and labour for re-winding charges for coil complete all as directed by Engineer-in-Charge.
Material charges for total insulating material complete all as directed by Engineer-in-Charge.
Materal and labour for total brazing work required for job complete all as directed by Engineer-in-Charge.
Material and labour for Heating charges complete all as directed by Engineer-in-Charge.
Material and labour for Gasket charges complete all as directed by Engineer-in-Charge.
Material and labour for new Copper winding strips/wire for (HV+LV) transformer complete all as directed by Engineer-in-Charge.
Labour charges for refixing of coil assembly, and box up and final testing charges complete all as directed by Engineer-in-Charge.
Taking out saturated silica gel from existing breather and Supply and replace silica gel crystal 3/4 mesh, 6 mm to 9mm, (Blue to Pink to white) in breather of transformers complete all as specified and directed
Taking out old unserviceable breather and Supply and replace silica gel breather assy 250 gms , made up of aluminium TOP ,Powder coated, Transaparent Centre Portion made of Polycarbonate of size 80 mm x 80 mm, Nitirle rubber O ring connection1/2 " BSP thread, filled with Silica Gel Blue (including silica gel crystal) suitable for transformer of capacity 100 KVA to 200 KVA complete all as specified and directed
Taking out old unserviceable breather and Supply and replace silica gel breather assy 500 gms , made up of aluminium TOP, Powder coated, Transaparent Centre Portion made of Polycarbonate of size 90 mm x 140 mm, Nitirle rubber O ring connection1/2 " BSP or 3/4 " thread, filled with Silica Gel Blue (including silica gel crystal) suitable for transformer of capacity 250 KVA to 630 KVA complete all as specified and directed
Taking out old unserviceable breather and Supply and replace silica gel breather 1500 gms , made up of aluminium TOP, Powder coated, Transaparent Centre Portion made of Polycarbonate of size, Nitirle rubber O ring connection1/2 " BSP or 3/4 " thread, filled with Silica Gel Blue (including silica gel crystal) suitable for transformer of capacity upto 1600 KVA complete all as specified and directed
Taking out old unserviceable breather and Supply and replace silica gel breather 3000 gms , made up of aluminium TOP, Powder coated, Transaparent Centre Portion made of Polycarbonate of size, Nitirle rubber O ring connection1/2 " BSP or 3/4 " thread, filled with Silica Gel Blue (including silica gel crystal) suitable for transformer of capacity upto 4000 KVA complete all as specified and directed
Supply and replace in repair Pin Insulator porcelain vitreous, white brown or green , 150 mm height, 150 mm dia including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut for conductor working pressure 11000 volt grade complete all as specified and directed including taking down old unserviceable. Make as per IS and Model/designed as per existing sample.
Supply and replace in repair Post Insulator porcelain vitreous, white brown or green , 150 mm height, 150 mm dia including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut for conductor working pressure 33000 volt grade complete all as specified and directed including taking down old unserviceable. Make as per IS and Model/designed as per existing sample.
Supply & replace in repair 11 KV Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism, GI pipe as down rod, coupling for pipe, lever and operating handle with locking arrangement worked from ground level, for current rating upto 200 amps. Make as per IS and Model/designed as per existing sample.
Material & labour for 33 KV outdoor type Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed including taking down old unserviceable. Make as per IS and Model/designed as per existing sample.
Materila & labour for fixing flexible control cable PVC insulated 19 core of size 2.5 sqmm FR PVC sheathed multistraded cable with bright annealed electrolytic bare copper conductor for voltage grade upto 1100 Volt for connecting control panel to VCB including taking down unsv one.
Taking out old unserviceable HT under ground cable of any size and rating complete all as specified and directed.
Supply, laying, testing and commencing of HT cable XLPE insulated screnned PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts (Earth grade) , of size 95 Sq mm 3 core all as specified and directed.
Material & labour for servicing/overhauling and decorbonising of 33/11 KV, out door PC VCB , replacement of un-serviceable spares, and serviceability check from remote operation, checking of all DC supply system, electrical circuit including connection of control cables to make it functional in all respect all as specified and directed by Engr -in - charge. Note :- (i) Spare parts/components required to replaced of above control panel shall be measured and paid separately under relevant items. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items, making the control panel serviceable and making all electrical connecto,. (iii) For item No. 78 to 80 below, fixing charges of items are considered and included in item No 77 herein.
Supply only closing coil (control) assembly 35 volt DC. as per existing sample.
Supply only triping coil (control) assembly 35 volt DC. as per existing sample.
Vacuum interrupter 33 KV grade as per existing sample.
Material & labour in repair for Filteration and dehydration of HV grade transformer oil of distribution and Power transformer of out door type of 11/.433 KV, 100 KVA to 750 KVA and Power transformer of 33/11 KV 1000KVA to 4000KVA min three cycle to achive die elctric strength of 40 KV to 60KV for 1 Minute at 4 mm gap as per relevent IS with portable filteration plant, testing the oil for die elctric strength, break down voltage before filteration and after filteration complete all as specified and directed by EIC. Note : Filteration to be done by Dehydration machine till the desired level of dielectric strength of tranformer oil comes to 60 KV . (ii) The contractor will test the dielectric strength of oil of each Tranformer & voltage stabilizer before starting dehydration & filteration and after completion of dehydration & filteration process and he will submit a record of same. (iii) Each sample of oil will be tested with a transformer oil test machine at site in presence of concerned JE's/Engr-in-charge and test result will be submitted accordingly). (iv) Centrifugal machine with all T&P and Testing Machine , oil required shall be arranged by contractor. (v) Oil required for topping up the transformer oil will be measured and paid seperately in relvent item.
Excavation in trenches not exceeding 1.50 m wide and n.exc1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. Note :Excavation for laying of cable to be done manualy carefully without distrubing existing cable or water pipe lines. If any damaged occured to exiting cable and pipe line during excavation contractor has to repair it with in time limit without any extra cost. If contractor delayed in repairing Panality @ of 500/- per hour to be charghed if repairing is not carry out in 12 hours. In this GE diecision will be full and final.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)
Supply & Fixing burnt clay fly ash bricks old size designation 75 (kg/cm2) in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
Supply only HT Tinned copper fuse wire, solid conductor of capacity 30 amp.
Supply & fixing ACSR Dog conductor with both end lugs for jumpering or connecting by proper size nut bolts in outdoor type CT/PT/LA etc at 33 KV switch yard complete all as specified and as directed.
Supply & fixing aluminium 33 KV grade PG clamps for existing aluminium bar system in switch yard by fixing with proper size nut, bolts complete all as specified.
Supply & fixing aluminium 33 KV grade Pad clamps for existing aluminium bar system in switch yard by fixing with proper size nut, bolts complete all as specified.
Material & labour for painting external surfaces of 33 KV/11 KV outdoor type transformer of capacity upto 4000 KVA by scraping out the corroded / rusted body by emery paper and painting the transformer body with spraying two coat of synthetic enamel paint of existing colour complete all as specified and directed.
Material & labour for preparation of old painted steel surfaces of any description, over 10 cm width or girth using polish paper and one finishing coat with aluminium paint complete all as specified and directed.
Supply & fixing ACSR conductor for LA continuity conductor with fixing arrangement, clamps, nuts, bolt etc fixed on existing HT pole of height above 15 Mtr around the 33 KV MRS switch yard approx length 200 mtr complete all as specified and as directed.
Supply only danger notice board/plate for HT of size 250 mm x 200 mm and 1.6 mm thick mild steel sheet, viterous enameled white with letters/figures and conventional skull and bones in signal red colour complete all as specified and directed.
Supply only HT insulation tape, self bonding type of size 2.5 cm x 9.1 m x 0.076 cm. for HT cable. Make - 3M.
Supply only Acrylic Aerosol spray paint HT VCB panel painting. Make - TVB.
M & L for rectification of transformer oil leakage problem from LT terminal, taking shut down, tracing out the cause of leakage, removing cable, draining out oil, removing of transformer top cover, replacement of seal, rectifying oil leakage, changing all gaskets, lightening of transformer core, tightenoing/ replacement of bushing/ stud, refilling oil, replacement of top cover gasket, reconnecting cables etc. and testing and commisioning complete all as specified and upto the entire satisfaction of Engr-in-Charge
Comprehensive maintenance and repair including maintenance of defective parts of all existing Tumbler, extractor of Laundry system, flatwork roller complete etc. located in domestic area as per existing ,make them 100 % serviceable incl checking its connections, and functionallity of laundry all to be checked and as per existingand making them all functional in all respect and if any defect observed to rectify the same by repair/replacement of spares parts after dismantling the old unserviceable parts through OEM or any certified agencies as approved by GE complete all as specified and directed by Engineer-in-Charge. Note:- (i) Cost of new components shall be paid separately under relevant items. (ii) Contractor's rep i,e OEM shall visit every month for routine maintenence but during breakdown or on urgent requirement , rep shall attend within 24 hrs to check all system and check its functionility and them functional. (iii) Work shall be carried out by OEM or any certified agencies as approved by GE . (iv) After every visit from OEM rep , service report shall have to submit to the Dept for payment purpose ,
Supply only V- Belt of any size and as per existing make complete all as specified and directed .
Supply only Three way Water solenoid valve as per existing make complete all as specified and directed.
Supply only Water Solenoid valve as per existing make complete all as specified and directed .
Supply only Rubber Ring for Door as per existing make complete all as specified and directed .
Supply only Vibration/Lead Sensor as per existing make complete all as specified and directed .
Supply only Toughened Door Glass as per existing make complete all as specified and directed.
Supply only Hose Pipe for Drain Straight as per existing make complete all as specified and directed.
Supply only Hose Pipe for Drain – L shape as per existing make complete all as specified and directed.
Supply only Hose Pipe for Chemical Dispenser – L shape as per existing make complete all as specified and directed.
Supply only Water inlet Pipe as per existing make complete all as specified and directed.
Supply only Door Limit switch as per existing make complete all as specified and directed.
Supply only Emergency stop push button as per existing make complete all as specified and directed.
Supply only Buzzer as per existing make complete all as specified and directed.
Supply only Heater Element upto 2 KW as per existing make complete all as specified and directed.
Supply only Contactoras upto 32A or as per OEM recommendation complete all as specified and directed.
Supply only Terminal Block, 2.5mm as per existing make complete all as specified and directed.
Supply only Terminal Block, 10mm as per existing make complete all as specified and directed.
Supply only MCB upto 63 A or recommended by OEM complete all as specified and directed.
Supply only Shocker as per existing make complete all as specified and directed.
Supply only Tension Spring as per existing make complete all as specified and directed.
Supply only Relay as per existing rating complete all as specified and directed.
Supply only SMPS as per existing make complete all as specified and directed.
Supply only PLC as per existing make complete all as specified and directed.
Supply only VFD, 7.5 HP as per existing make complete all as specified and directed.
Supply only Motorized Drain Valve as per existing make complete all as specified and directed.
Supply only finger guard limit switch as per existing make complete all as specified and directed.
Supply only Teflon wire complete all as specified and directed.
Supply only steel wool complete all as specified and directed.
Supply only steel Gear Oil complete all as specified and directed.
Supply only PU Pipe, 12mm as per existing make complete all as specified and directed.
Supply only PU connector as per existing make complete all as specified and directed.
Supply only Padding cloth as per existing make complete all as specified and directed.
Supply only Single phase preventer as per existing make complete all as specified and directed.
M&L for chest polishing of machine complete all as specified and directed .
Comprehensive maintenance and repair including renewal / replacement of minor defective parts of electrically operated lift of capacity 08 passenger (680 Kgs), fully down collective with microprocessor based control panel, automatic operated sliding doors, service ground plus upper four floors (G+4). as per existing make. - KONE ELEVATOR INDIA PVT LTD installed at DWR Bldg including carrying out the daily check and routine periodical service as mentioned in PS of fully automatic electric lift with power operated door to examine, lubricate & adjust the equipment and to carry out planned maintenance in a systematic and controlled manner using techniques and expertise trained skilled mechanics and engineer from OEM or any certified agencies as approved by GE . The monthly services includes cleaning the machine room equipments, Clean & lubricate hoist way equipment & entrances, Cleaning the pit equipment, Greasing & oiling the bearings and guides, Cleaning lift cabin, car & all landing doors, Equalize the tension of all hoisting ropes. During the routine check up of lift if any parts of lift found unserviceavle to be replaced and then item shall be paid separately under respective item. NOTE : (i) OEM or any certified agencies as approved by GE shall visit every Months and service report shall submit to the Dept for payment purpose . (ii) If any spares found unserviceable then the same shall be replaced under relevant item of this schedule as supply only .
Supply only GGCPUm ASSEMBLY complete all as specified and directed by Engr-in-charge
Supply only AMD D10 MOTOR ASSEMBLY complete all as specified and directed by Engr-in-charge.
Supply only SENSOR,MAGNET 100VDC 150VAC D12MM complete all as specified and directed by Engr-in-charge
Supply only SENSOR,MAGNET 250VDC 250VAC 3A D12MM complete all as specified and directed by Engr-in-charge
Supply only Door Sensor complete all as specified and directed by Engr-in-charge
Supply only CONTACTOR,25A 230V 50HZ complete all as specified and directed by Engr-in-charge
Supply only BRAKE MAGNET ASSY,200V MR12 complete all as specified and directed by Engr-in-charge
Supply only GEAR INTERNAL,RATIO 1/43 MR12 complete all as specified and directed by Engr-in-charge
Supply only BUTTON, ROUND SURFACE MOUNTED SYMBOL UP complete all as specified and directed by Engr-in-charge
Supply only BUTTON, ROUND SURFACE MOUNTED SYM DOWN complete all as specified and directed by Engr-in-charge
Supply only AMD D10 SPARE MODULE (PARALLEL) -G03 complete all as specified and directed by Engr-in-charge
Supply only battery 7.5 AH with SMPS battery charger complete all as specified and directed by Engr-in-charge
Supply only Fan suitable for car complete all as specified and directed by Engr-in-charge
Supply only Light suitable for car complete all as specified and directed by Engr-in-charge
M&L for repair , Overhauling and Servicing of EOT crane Make : SAFETECH including complete checking of Brakes for hoists and cranes, cable trolley, control panel, coupling, drives, end carriage, gear box Hoist crab, hooks, rail clamp, rope drum, runner wheel, spring buffer, thrusters and winch etc. Replacement of unserviceable accessories and made fully serviceable including load testing through any authorised gogt agency complete all as directed by Engineer-in-Charge. Note :- The job include the following and the rate shall deemed to be inclusive for the unit quoted rate as under :- (A) Crab Hoist Part : Repair , Over hauling & servicing including Oil change & greasing etc. (i) Crab Hoist Gear box : Overhauling (ii) Thruster brake : Change of Oil and Overhauling (iii) Hoist Bottom Block : Full Servicing (iv) Hoist Rope : Full Servicing (B) Cross Travel Trolley : (i) Cross Travel Wheel : 4 set (ii) Coupling Bush : 12 Nos (iii) Hoist Bottom Block : Wheel Alignment (C) Long Travel Trolley & End trucks : (i) EM Solenoid Shoe brake : 01 set (ii)Both sides carriages : Complete Overhauling (iii) Runway track : Dismantling , complete checking , making functional if any defects found. (iv) Both sides Gearbox & motor : Overhauling . (v) Dual speed Pendant Push Button - 01 Set (vi) Relay of existing capacity - 04 Nos (vii)Panel box : Complete servicing incl replacement of faulty wiring (viii) LT Wheel Alignment/Diagonal : Complete Overhauling .
S & F in repair 180AH,12 Volt lead acid battery complete all as specified and directed by Engr-in-Charge. Make: Exide or equivalent.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
TENDERDOCUMENTSLIFT.pdf
Tender Documents • 0.71 MB
BOQ_821994.xls
BOQ • 1.10 MB
8719.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .