| 1 | L1₹34.9 LAccepted-AOC HOUSE NO E 1 PANCHSHEEL NAGAR NARMADA ROAD JABALPUR MP 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹35.1 L+₹18,438 (0.53%)Rejected-Finance D 154 ADARSH NAGAR NARMADA ROAD JABALPUR 482001 M P | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.7 L+₹2.7 L (7.81%)Rejected-Finance 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.9 L+₹4.9 L (14.1%)Rejected-Finance 37A 115 MADHU NAGAR AGRA 282001 UP | AGRA | AGRA | UP | 282001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.6 L+₹6.7 L (19.1%)Rejected-Finance H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹44.1 L
EMD Value
₹88,300
Closing Date
27 Jan 2024, 5:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF CEMENTED COVERED DRAIN FOR WASTE WATER FROM T-JUNCTION OF QTR GUARD TO CSD HQ 1STC,PROVN OF 03XALS AMBULANCE VEH PARKING SHED WITH HARDSTANDING ELECT CONNECTION IN FRONT OF MT GARAGE OF MH IN THE AREA AGE B/R-III UNDER GE (W) JABALPUR
2023_MES_635093_1
8667/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (West) Jabalpur
₹88,300
23 Feb 2024
30 Dec 2023
1 Feb 2024
1 Jan 2024
27 Jan 2024
13 Jan 2024
1 Jan 2024 - 8 Jan 2024
Amount
Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out any type of soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out any type of soil complete all as specified and directed.
M & L excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in soft/loose, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
Returing, filling in, spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified & directed.
Removing surplus soil to a distance n.exc 50m and depositing where directed at a lvel n.exc 1.5m above the starting point complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and lev- elled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed.
M & L 50 mm thick sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40mm fraded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M & L for Plain Cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in surface channels and drains.complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid separately)
M&L for Precast cement concrete M 15 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.complete all as specified and directed.
M&L for Brick work with Fly ash modular bricks,straight or curved on plan exc 6M mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with kiln burnt bricks built in CM (1:4) using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius with old size bricks all shown on drawing and as specified.
Use and waste of formwork to sides of foundations, footings bases for columns, rafts and rafts beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough finished surface of concrete flat all as specified. complete all as specified.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild Steel TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F rolled section as in man and cross beam ,hip and jack rafters ,purlin where connected to common rafters and running rails and guides for sliding doors ;fixed for sliding ;fixed with angle cleats or other connecting plates complete all as specified and directed.
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E-165)complete all as specified and directed.
S & F mild steel bolts exc 20 & n, exc 25 mm dia, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S& F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ® complete all as specified and as directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ® complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 ,Type B2 ,using 40 mm graded aggregate as in paving /path finished fair and even complete all as specified and directed.
M&L for 80 mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS - 15658-2006 of 80 mm thicknes M-40 Grade with pigment complete all as specified and as directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surfaces of walls with water proofing compound as per manufactures instruction finished even and smooth without using extra cement complete all as specified and as directed. ( Note:- WPC shall be measured and paid separately)
M&L for 15mm thick rendering in CM 1:6 on fair faces of bricks or concrete surfaces finished fair and even complete all as specified and as directed.
M & L for applying two coats of cement base paint over a coat of primer including preparation of surfaces complete all as specified and as directed.
M&L for applying three coats of white wash on newly plastered or unplastered surfaces of walls including preparation complete all as specified and as directed.
M & L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M & L for preparation of new or previously untreated surfaces of of steel of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed..
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor FRLSH cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of anticorrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white Bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor FRLSH cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed.
(a) One light point controlled by one switch.
(b) One socket point controlled by one switch on same board.
All as described in serial item No. 36 here-in-before, but with 1100 volts grade copper standard conductor FRLSH cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor cable for 3 pin 15 Amp switch socket outlet independent board complete all as specified and directed.
S & F in repair for switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S & F Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed.
S & F Ceiling rose surface bakelite 65 mm x 50 mm three terminal AC 230 volts flush type complete all as specified and as directed.
S & F switch socket combination multipin 5 and 16 Amps AC 230 volts flush type complete all as specified and as directed. Make : Anchor, Plaza, Leader
S&F in repairs Smart bright Batten Series, LED luminaire using LED 22 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), (Make : Philips Cat part No BN 021 LED 22S 6500/4000 PSU GR S1 or equivalent makes as mentioned here-in-after.
S&F in repair sheet metal enclosure DBs single pole and neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and as directed.
S & F in replacement MCB Single pole and neutral rated capacity 240 Volts 40 Amps, B series complete all as specified and directed by Engineer in charge
Supply and fixing in replacement MCB/Isolators single pole 240 volts upto 40 Amps, B Series complete all as specified and directed by Engineer in charge
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix replacement of LED Security light Luminaire 25 watt with 2500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted dreiver suitable of 180 to 270v, 50Hz, light engine driver base pole adapter, powder coated pressure die cast aluminium eith heat resistant toughened glass with lens type, GI pole fitting clamps made out of MS flat, nuts and bolts and painting with aluminium paint complete all as specified and as directed. Make: Philips cat part No: BRP029 LED25/WW MRPSU GR DX or Havells cat part NO ENDURASUNDOWNSL25WLED765PASYBOPCIHD or equivalent in Wipro/GE
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and directed by Engineer in charge
Supply and lay DWCP pipe OD 65 mm , ID 38 mm all as per required and directed by Engg I charge(Necessary excavtion may please be added in rate quoted) complete all as specified and as directed.
RADHEY CONSTRUCTION
Tiki Water proofing Co
M/s Om Infracon
DEEPAK CONSTRUCTION
M/S Modern builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .