Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.1 LAccepted-AOC | 1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹88,472
Closing Date
20 May 2021, 3:00 pmClosed
EXECUTIVE ENGINEER
Water Supply and Sanitation Division No.2, Mansa Near DAC Bachat Bhawan Mansa
AS PER DNIT
2021_WB_64712_1
WSSD/MANSA-DIV-2 /2020-21/007
Open Tender
Civil Works - Water Works
Item Rate
120 days
MANSA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10
Yes
₹88,472
Yes
18 Jun 2021
4 May 2021
21 May 2021
4 May 2021
20 May 2021
4 May 2021
Item Wise Description :
Carriage of Earth, Surkhi, sand, Fly Ash, bajri, ballast, stone boulders, kankar and building rubbish, Earth. Carriage of material excluding initial lead of 5 Km (a) Phillaur Sand (Av. Lead 167 Km) 0 to 167 km
Carriage of material excluding initial lead of 5 Km (b) Ghaghar Sand (Av. Lead 320 Km) 0 to 320 km
Carriage of material excluding initial lead of 5 Km (c) Bajri Sand (Av. Lead 320 Km) 0 to 320 km
Carriage of material excluding initial lead of 5 Km (d) Filter Media (Av. Lead 320 Km) 0 to 320 km
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Earth Filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.
Removing doors and windows (steel and wood) with chowkhats by making recesses in walls when the wall not to be dismantled. Door of area 3 sqm and below
Windows of area 3 sqm and below
Scraping Cement plaster
Cement concrete 1:8:16 With stone aggregates 40mm gauge, mixing by mechanical means using concrete mixer volumetric type
Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
Providing and fixing cast iron 100mm dia rain water pipe with screw and wooden plugs fixed and wall face including filling joints with spun yarn and cement mortar 1:2 excluding head and shoes etc.
Providing and fixing cast iron head for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2
Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2
12.5 mm thick cement plaster 1:2
Cement rendering on plaster 1mm thick
White wash (Three coat)
Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Applying pink primer on aluminum priming coat on wood work including prepration of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. panelled, glazed or glazed and panelled. 35 mm thick
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Nuts & Bolts of all sizes and length required
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. and excavation of pipe line, minimum cover on pipe One meter (6kg/cm2 pressure) 63 mm o/d
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. and excavation of pipe line, minimum cover on pipe One meter (6kg/cm2 pressure) 90 mm o/d
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. and excavation of pipe line, minimum cover on pipe One meter (6kg/cm2 pressure) 160 mm o/d
Providing, Stringing out, cutting, Jointing and testing of C.I. Double Flanged pipes with casted flanged as per IS:7181, Class-B (ISI marked with the prior approval of Engineer-inCharge) and laying the same in trenches to correct alignment and gradients, jointed with nut bolts and rubber insertion fitted complete including all cartage. 200 mm i/d pipe line
Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-inCharge conforming to ISI specifications. C.I. specials upto 300mm i/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). Class PN-1 as per ISI 80mm i/d Sluice Valves
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). Class PN-1 as per ISI 200mm i/d Sluice Valves
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Class PN-1.0 as per ISI with rubber Flap 200mm i/d Non-return valve
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, ncluding cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 20mm i/d
Providing and placing in horizontal layers filtering mei/d screened, washed and cleaned as described below :- Top layer :----- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4mm with uniformity coefficient 2.00 to 3.00) from Pathankot or other approved source.
Second Layer :----- Coursed sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry).
Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm (from Pathankot or approved equivalent quarry).
Fourth Layer :----- Bajri (Coursed) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry).
Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry).
Construction of masonry sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. 0.60 x 0.60 m
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC manhole cover with frame 560 mm i/d RCC manhole cover with frame as per ISI Medium duty
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16/20Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (With fan box)
Wiring light point
Wiring 6Amp. wall socket point
Wiring 16/20Amp. power plug control point
Non Schedule Items Providing house hold connection including laying, jointing, fixing testing below ground level MDPE pipe and above of ground level GI pipes (as approved by Engineer-In-Charge), including cost of excavation, Refilling, CI bib cock as per IS:210 with stainless steel spindle, 15mm i/d GI pipe 2.50 Mtr. & 15mm o/d MDPE pipe 2.00 Mtr. (length on average basis) 3" uPVC clamp, ISI marked G.M. Ferrule as per IS:2692 connection of 10mm i/d ferrule medium, specials such as tees, bends, sockets, elbow, nipples (100 mm & 150mm) Union Couplings, GI hooks, Dhagha Sephaida etc., cutting, threading, making hole in wall and testing in tranches in the ground all material should be of approved make (to the approval of Engineer-in-charge) complete in all respect including cost of carriage. (Ref. CSR item Nos. 28.1, 28.34 (a), 28.36 (a), 30.65 b (i). Water Connection on Old pipe line
(ii) Water Connection on New pipe line
Non Schedule Items Provision for connecting the proposed pipe with existing pipe line any size including cost of excavation, bailing out water, uPVC T/ Bend/ Elbow/ Socket/ pipe piece / D-joint and Bailing out water etc. complete in all respect.
Non Schedule Items Dismantling brick or flagged stone flooring without concrete base.
Non Schedule Items Providing, installing testing & commissioning of 2 No. electrically centrifugal driven pump set capable of delivering 2160LPM against a head of 38 Mtr and 13 mtr complete in all respects (i) Clear Water Pumping set, Discharge = 2160 LPM, Head = 38 Mtr, BHP = 30.00 (Motor with Pump)
Non Schedule Items Providing, installing testing & commissioning of 2 No. electrically centrifugal driven pump set capable of delivering 2160LPM against a head of 38 Mtr and 13 mtr complete in all respects (ii) Raw Water Pumping set, Discharge = 2160 LPM, Head = 13 Mtr, BHP = 10.00 (Motor with Pump)
Non Schedule Items Provision for electric panel board consisting of electrical appliances Such as automatic Star Delta Push Button or oil immersed starter, Main Switch, Voltmeter .Ampere Meter, ELCB, Shunt Capacitor. Single Phase, preventer indicating Lamps , Kit Kat etc. including cost of Electronic over current relay complete in all respects. (i) Panel Board for Clear water motor
Non Schedule Items Provision for electric panel board consisting of electrical appliances Such as automatic Star Delta Push Button or oil immersed starter, Main Switch, Voltmeter .Ampere Meter, ELCB, Shunt Capacitor. Single Phase, preventer indicating Lamps , Kit Kat etc. including cost of Electronic over current relay complete in all respects. (ii) Panel Board for Raw water motor
Non Schedule Items Providing, installing, testing & Commissioning one no. Electronically actuated, Diaphragm operated, Metering system, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6.0 Liters of Bleaching powder solution/ Sodium Hypo Solution per Hour under maximum delivery pressure up to 7 kg./ scum and suction lift not less than 1.5m as per DWSS standard specifications.
Non Schedule Items Taking out and washing filter media and placing the same after washing, cleaning in filter beds. a) Top Layer :-- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4mm with uniformity coefficient 2.00 to 3.00)
b) Second Layer :-- Coarse sand screened, cleaned and washed and graded from 3mm to 6 mm
c) Third Layer :-- Bajri screened, cleaned and washed and graded from 6mm to 20mm
d) Fourth Layer :--- Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm
e) Bottom Layer :-- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm
Non Schedule Items Washing the false floor slabs with brushing & cleaning the cross drains etc. complete in all respects.
Non Schedule Items Repair of expansion joint for existing OHSR (i) 150mm i/d
(ii) 200mm i/d
Non Schedule Items Providing & Fixing ISI Marked 1200mm Ceiling Fan (White) & Regulator etc. complete.
Non Schedule Items Providing & Fixing ISI Marked 18-Watt LED Tube Light (Cool Day Light) complete.
Non Schedule Items Providing & Fixing ISI Marked 15W B22 LED Bulb (Cool Day Light) complete.
Non Schedule Items Proving & Fixing C.I. T - TYPE / Rose ventilator complete in all respects
Non Schedule Items Proving & Fixing CI assembly & flanged for CI Slucie valve and CI Bends. (d) 200 mm
Non Schedule Items Painting of Sign Boad at W/W Site
Non Schedule Items Credit of old Sluice Valve of size 200mm i/d
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .