EXECUTIVE ENGINEER (ELECTRICAL)
CSIR MADRAS COMPLEX, TARAMANI, CHENNAI-113
Rewiring of RP and UPS wiring and replacement of light fitting, power DBs, Fire alarm system etc., in G3 room at CECRI unit in CSIR Campus
2021_CSIR_73249_1
480(385)/2020-21/EW
Open Tender
Electrical Works
Works
60 days
CSIR MADRAS COMPLEX, TARAMANI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹12,000
31 Mar 2021
15 Mar 2021
31 Mar 2021
15 Mar 2021
30 Mar 2021
15 Mar 2021
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in the existing surfac/recess medium class including pvc conduit with modular switch,modular plate suiatble GI/PVC box and earting the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc.., as required.
Group B
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Two way 5/6A switch
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
12 Module
2 Module
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recess steel/PVC conduit as required.
3 x 2.5 sq mm
3 x 4 sq mm
3 x 6 sq mm
6 x 6 sq mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable including PVC conduit in the existing surface as required
3 x 1.5 sq mm
4 X 16 Sq + 2 X6 Sq mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
TP MCB
Supplying and fixing of following way ,single pole and neutral ,sheet steel ,MCB distribution board ,240V,on surface/recess ,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar, interconnections,powder painted including earthing etc..,as required.(But without MCB/RCCB/Isolator)
12Way SPN Double door
supplying and fixing of DP sheet steel enclosure on surface/recess along with 25/32A 240V C curve DP MCB complete with connections,testing and commissioing etc..,as required
Supplying and Drawing of UTP 4 pair CAT 6 Lan cable in the existing surface/recessed steel/ PVC conduit as required
2 run of cable
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmoured telephone cable in the existing surface/recessed steel/apvc caonduit as required
Earthing with copper earth plate 600 mm x 600 mm x3 mm thick including the accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with chacoal/coke and salt as required.
supplying and fixing of TP 63A 415V C curve MCB in the existing power DB including complete with connections,testing and commissioing etc..,as required
supplying and fixing of FP RCBO sheet steel enclosure on surface/recess along with 32A 415V C curve FP MCB complete with connections,testing and commissioing etc..,as required.Make: Legrand/Siemens/Schinder
Supply,Installation,testing and commissioing of surface mounted LED fitting type,LED 2' X 2' full glow luminaire consuming a system wattage 36w and delivering an system lumen of minimum 3600 lumens,with electronic driver,incoming connections with 1.5 sq mm FRLS PVC insulated,copper conductor,single core cable,earthing required , and suitable fixing accessopries. etc as required,as per site condition.Model No: LCTLSNE-36-FO-CDL,Make:Crompton or similar models in philips/bajaj)
Supply,Installation,testing and commissioing of surface mounted type,LED 1' X 1' or square luminaire consuming a system wattage 18W and delivering an system lumen of minimum 1800lumens,with electronic driver,incoming connections with 1.5 sq mm FR PVC insulated,copper conductor,single core cable,earthing required , etc as required.(Make. Crompton \ philips/bajaj)
Supplying and fixing of modular RJ 45 socket outlet with shutter (1 Module) in the existing modular box including connection ,testing as required as per site condition.
Supplying and fixing of following ways surface/recess mounting,vertical type,415V,TPN MCCB distribution board of sheet steel,dust protected,duly powder painted,inclusive of 250A tinned copper bus bar,common neutral link,earth bar,din bar with provision for DPX 160 MCCB as incomer and SP/TP MCB's as outgoing mounting as required as per site condition.
12 way , Double door,MCCB VTPN DB
8 Way ,Double Door MCCB VTPN DB
SITC of 4 Pole,160A MCCB ,16KA,Thermal Magnetic protection unit in the existing MCCB DB including spredder for connection incoming and out going cables as reqired as per site condition.Make: Legrand ,Schinder and Hager.
SITC of 4 Pole,100A MCCB ,16KA,Thermal Magnetic protection unit in the existing MCCB DB including spredder for connection incoming and out going cables as reqired as per site condition.Make: Legrand ,Schinder and Hager.
Supplying and fixing of 3 phase 415V Metal Tempra plug & socket DB 63A 3Ph +N+E-FP including FP 63A C curve MCB in the existing surface including connection,testing as required as per site condition.as per IEC 61439-3.Make: Legrand/schinder/hager
Supplying and fixing of 1200mm 5 star rated(BEE) ,High speed ceiling fan with suiatble down rod in the existing surface including connection,testing as required as per site condition.Make: Orient,Model:Hector 500 I series or in Similar Model in Usha/Crmpton
Supplying and fixing of following size DLP U PVC trunnking without partion, suitable flexi cover including necessary fitting accessories in the existing surface, as required as per site condition.Make:Legrand.
105 x 50 mm including Full flexiable cover
32 x20 mm mini truncking
cover joints 85 mm
flat angle 90 DEGREES
End cap for 105 x 50 mm
SITC of following Fire Alarm panel and smoke detector in the existing wall surface including connection,testing as required as per site condition.Make: Ravel/Agin/Apollo
Conventional Micro Processor Based 2 Zone Fire Alarm panel
12V/7AH SMF Battery
Conventional smoke detector with base
Conventional Manual call point
Conventional Electronic hooter
Junction box
Removing the existing Raw power , ups wiring ,point wiring,ceiling fan , PDB,s (3 nos) including the power wiring as requires as per site condition in G3 room.
Supplying and Laying of 2 core x 1.5 FRLSH sq mm -Fire Alarm system Arm Cable-Red colour in the existing surface including suitable fixing accessories as per site condition as required.Make: Polycab/RR/Havells
Removing and relocation of the existing 4 feet twin led tube lights(12 Nos) with down rod in the existing surface and fixing in different location including connection,testing ,commissioing as required as per site condition.
Supplying and fixing of 20A,240V, SPN Industrial type socket outlet,with 2 pole and earth,metal enclosed plug top alongwith 20A 'C' curve ,SP MCB ,in sheet steel enclosure ,on surface or in recess,with chained metal cover for the socket outlet and complete with connection,testing and commissioing as required.
supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC Sheathed/XLPE aluminium conductor cable of 1.1kv grade as required.
4 x 25 sq mm
3.5 x 95 sq mm
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections as required. Note 1: The rates quoted for all items shall be inclusive of Income tax, GST & TNCWW Cess etc., as applicable. Note 2: TNCWW Cess @ 1%, Income tax @2 % and TDS on GST @ 2 % will be deducted from the bill.
kaveri electricals
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .