| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | ₹1.3 Cr | L1 | Accepted-AOC As per NIT |
| 2 | L2₹1.3 Cr+₹86,455 (0.65%)Rejected-Finance | ₹1.3 Cr+₹86,455 (0.65%) | L2 | Rejected-Finance As per NIT |
Tender Value
₹1.3 Cr
EMD Value
₹2.7 L
Closing Date
8 Dec 2023, 2:00 pmClosed
SUDHIR KUMAR
Electric Department West Zone MCD
Provision of DG Set along with allied accessories for Mata Gujri Hospital Tilak Nagar under MCD West Zone
2023_MCD_176293_1
EE/Elect/WestZone/2023-24/40
Open Tender
Electrical Works
Item Rate
120 days
WEST ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹2.7 L
19 Feb 2024
1 Dec 2023
8 Dec 2023
1 Dec 2023
8 Dec 2023
1 Dec 2023
Amount
Approved Rate
OD9627/2023-2024:Supply, installation, testing and commissioning of Exhaust Pipeline along the wall of the building in vertical/horizontal direction using B Class MS pipe of 14 inch(350 mm) dia with bend ,flanges, Nut & Bolts, Reducers etc along with providing insulation for pipeline using 50mm aluminum sheet with glass wool /mineral wool 26g covered with wire mesh/cock mesh with proper rivets including required exhaust pipeline supporting angle iron with proper welding and joint plates in every angles painted with red oxide primer & enamel paint including crane charges etc as required suitable for 750 KVA DG Genset
OD9628/2023-2024:Supply, installation, testing and commissioning of Exhaust Pipeline along the wall of the building in vertical/horizontal direction using B Class MS pipe of 10 inch(250mm) dia with bend ,flanges, Nut & Bolts, Reducers etc along with providing insulation for pipeline using 50mm aluminum sheet with glass wool /mineral wool 26g covered with wire mesh/cock mesh with proper rivets including required exhaust pipeline supporting angle iron with proper welding and joint plates in every angles painted with red oxide primer & enamel paint including crane charges etc as required suitable for 750 KVA DG Genset.
OD9629/2023-2024:Supply, Installation, Testing, and commissioning of AMF panel suitable for 750 KVA DG set with complete accessories as required.
OD9630/2023-2024:Supply, Installation, Testing, and commissioning of 750 KVA (CPCB -IV + compliant) rating silent DG Sets comprising of suitable engine coupled to suitable alternator mounted on a common base frame along with other accessories i.e Acoustic enclosure, control panel, fuel Tank, battery with leads complete as required.
122.1.21:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*120 sqmm
122.1.26:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*400 SQMM
122.1.34:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*95 sqmm
122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
OD10421/2023-2024:DSR 2022 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD10570/2023-2024:DSR 2022 2.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
OD10576/2023-2024:DSR 2022 7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
OD10577/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD10578/2023-2024:dsr 2022 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD10579/2023-2024:dsr 2022 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
OD10580/2023-2024:dsr 2022 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD10581/2023-2024:DSR 2022 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD10582/2023-2024:DSR 2022 2.2.9 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A, 35 KA,TPMCCB
OD10583/2023-2024:DSR 2022 2.2.7 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 35 KA,TPMCCB
OD10584/2023-2024:DSR 2022 2.2.19 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 A,50KA,FPMCCB
OD10667/2023-2024:DSR 2022 7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD10668/2023-2024:DSR 2022 7.6.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
OD10669/2023-2024:dsr 2022 7.6.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
OD10670/2023-2024:dsr 7.6.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
OD10671/2023-2024:DSR 2022 7.5.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
OD10672/2023-2024:DSR 2022 7.5.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
OD10673/2023-2024:DSR 2022 7.5.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
OD10684/2023-2024:DSR 2022 1105 Supply of 10.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD10685/2023-2024:DSR 2022 1104 supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD10686/2023-2024:DSR 2022 1103 supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD10687/2023-2024:DSR 2022 1102 supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD10688/2023-2024:DSR 2022 1101 supply 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD10689/2023-2024:Supply, Installation, Testing and Commissioning of Submersible dewatering pumpset Suitable for Storm Water/Sewage/Raw water having ratingupto 6 to 7.5 Hp, Head - 15 mtr, IP 68 with minimum capacity of 40 m3/hr (666 lpm) for Automatic operation for emergency conditions.
OD10690/2023-2024:Supply, Installation, Testing and Commissioning of Submersible dewatering pumpset Suitable for Storm Water/Sewage/Raw water having rating upto 2.5 to 3.0 Hp, Head - 15 mtr , IP 68 with minimum capacity of 5 m3/hr (82lpm) for normal/manual operation for normal conditions.
OD10691/2023-2024:S/I/T/C of Automatic Water Overflow Control Panel to automatically sense and stop the motor in case of overflow of tank complete as required.
OD10693/2023-2024:S/I/T/C of water level sensor prod. as required.
DSR civil
2.13.1.3:Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Water Power Engg Enterprises
Bidder Name
Water Power Engg Enterprises
VOID FIRE CONSULTANTS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .