GE (AF) AWANTIPUR C/o 56 APO PIN-937208
ADDN/ALTN TO CERTAIN BUILDINGS WITH CONTROLLED ENVIRONMENT AUTOMATIC TEMPERATURE AND HUMIDITY SENSOR AT 8FBSU, AF
2026_MES_773774_1
GE (AF) AWA-16/2026-27
Open Tender
Civil Works
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹19,400
Yes
20 Jun 2026
20 Jun 2026
13 Jul 2026
20 Jun 2026
11 Jul 2026
4 Jul 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE (AF), 8FBSU,AF
Name of Work: ADDN/ ALTN TO CERTAIN BUILDINGS WITH CONTROLLED ENVIRONMENT AND AUTOMATIC TEMPERATURE AND HUMIDITY SENSOR AT 8FBSU
Contract No: GE (AF) AWA-16/2026-27
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles & rubbish of the premises complete. 32 Sqm 0 Full Conversion INR
M&L coloured/printed vitrified tiles 9 to 10mm thick (square or rectangular ) of area exc. 0.18 sqm and not exc 0.36 sqm and laid in floors etc., set and jointed in neat cement slurry and painted in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement, complete all specified and directed. 32 Sqm 0 Full Conversion INR
Dismantling of plain or corrugated steel sheeting of any gauge, thickness etc in roof coverings/ cladding/ eave etc complete all as specified. 38.25 Sqm 0 Full Conversion INR
S&F galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hooked bolts with washers in roof, 0.63mm thick, grade-O quality, with 120 grms/sqm zinc coating and grade 'B' Class 8, complete all as specified and directed by Engineer-in-Charge. 26.25 Sqm 0 Full Conversion INR
S&F Galvanised plain mild steel sheeting 0.63mm thickness fixed with 'L' type or 'J' or cranked hook bolts with washers, in roofs as in ridge etc all as specified and directed. 4.5 Sqm 0 Full Conversion INR
S&F 1.00mm thick Plain, galvanised, mild steel sheeting, in eaves board & straight flashings (length & girth as fixed) with welded and shouldered joint to be provided all as specified and directed by Engr-in-Charge. 7.5 Sqm 0 Full Conversion INR
Preparation of new painted surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10cm width or girth, not otherwise described and applying two coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown), complete all as specified and directed. 41.93 Sqm 0 Full Conversion INR
M&L for preparing of old painted steel surfaces over 10cm width or girth and making good with & including by necessary red lead putty and make the surface smooth by rubbing with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of steel complete all as specified and directed. 35 Sqm 0 Full Conversion INR
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 12.92 Cum 0 Full Conversion INR
M&L for rendering 10mm thick on fair faces of concrete/brick interior surfaces in cement mortar 1:6 on wall finished fair and even without using extra cement, complete all as specified and directed. 64.8 Sqm 0 Full Conversion INR
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on wall surfaces, finishing the surface even and smooth without using extra cement, complete all as specified. Note:- Integral water proofing compound shall be measured and paid for separately. 64.8 Sqm 0 Full Conversion INR
M&L preparation of newly plastered wall surface and applying of Birla/JK white wall putty approx 3 mm thick as per manufacturer's instruction and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified and directed. 60.96 Sqm 0 Full Conversion INR
M&L for complete removal of existing treatment of old decorated plastered or un-plastered surfaces of wall and applying 3mm wall putty and two coats of Acrylic washable distemper over a coat of primer, complete all as specified and directed. 25.44 Sqm 0 Full Conversion INR
Preparing new plastered or un-plastered surfaces of walls and applying two coats Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, Grey & Brown colour) over a coat of acrylic primer, complete all as specified and directed. 108 Sqm 0 Full Conversion INR
Taking down (Steel/ Wooden) chowkhats of frames of any description exceeding 1.5 Sqm and n.exc 4 Sqm with shutters (without taking off shutters from the frames) and making good disturbed portion, complete all as specified and directed. 7 Each 0 Full Conversion INR
S&F Anodised aluminium frame for doors, windows and ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified 60 Kg 0 Full Conversion INR
S&F anodised aluminium door shutters, aluminium section weighing 1.10kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. with glass on upper half, complete all as specified. Note : Glass to be measured separately. 4.4 Sqm 0 Full Conversion INR
Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing of 0.55 Kg/RM including fixed with aluminum beading, silicon lining and gaskets, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note : Glass to be measured separately. 10.8 Sqm 0 Full Conversion INR
M&L for 12 mm prelaminated particle board both side decorative, fixed with aluminium beading and rubber neoprene packing to aluminium frame, complete all as specified. 6.5 Sqm 0 Full Conversion INR
M&L for 4.8 mm thick frosted sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane, complete all as specified and directed. 6.5 Sqm 0 Full Conversion INR
S&F wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples with 25 mm mesh size, compete all as specified. 6.5 Sqm 0 Full Conversion INR
S&F Aluminium (extruded section body) automatic door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed, complete all as specified and directed. 2 Each 0 Full Conversion INR
S&F in repair brass 4-levers Mortice lock, vertical type, size 100mm for aluminium door, complete all as specified and as directed. 1 Each 0 Full Conversion INR
M&L for prelaminated particle board 18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination with all around 6mm thick teak wood beading as in, cup board shutters, shelves, palmet boxes etc, fixed to timber frame complete all as specified 6.5 Sqm 0 Full Conversion INR
S&F 75 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed for cupboard shutter compete all as specified. 18 Each 0 Full Conversion INR
S&F for size 125mm Brass handles, cast type, polished bright, complete all as directed by Engr-in-Charge. 6 Each 0 Full Conversion INR
M&L RCC (nominal mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like Type B1 1:2:4 (20 mm graded aggregate), complete all specified and directed. 0.8 Cum 0 Full Conversion INR
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all specified and directed. 52 Kg 0 Full Conversion INR
Formwork to sides and soffits of floor or slab, roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. 6 Sqm 0 Full Conversion INR
S&F 6 mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws as in false ceiling, complete as specified and directed. 28.16 Sqm 0 Full Conversion INR
S&F Anodised aluminium/ GI snap grid frame work for false ceiling of grid size 605x605 mm and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia. 40 mm long, complete all as specified and directed. 28.16 Sqm 0 Full Conversion INR
Demolition of cement concrete to ground floor(unreinforced) and paving n.exc 15cm thickness (below or above ground level) and removing rubbish of out side MOD land, complete all as specified and directed. 3.03 Cum 0 Full Conversion INR
M&L 100mm thick cement concrete 1:2:4 Type B-2 (using 40mm graded crushed stone aggregate) as in hardstanding including finishing even and smooth without using extra cement, complete all as specified and directed. 10 Sqm 0 Full Conversion INR
M&L 75 mm thick PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in plinth protection even and smooth without using extra cement, complete all as specified and directed. 27 Sqm 0 Full Conversion INR
Taking down carefully unserviceable copper/ aluminium point wiring (light, fan, socket, power or AC,s) complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed. 28 Per Point 0 Full Conversion INR
Point wiring for one light point/ fan point controlled by one switch with 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including concealed pvc conduit on wall/ceiling with all fittings (ISI marked) controlled by one switch including CI/MS sunk box required size including base plate and switch cover etc., complete all as specified and directed by Engr-in-Charge, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete.
(a) One light point controlled by one switch. 15 Per Point 0 Full Conversion INR
(b) One 3 pin socket outlet point 5 Amps on independent, with cables 1.5 sq. mm size . 9 Per Point 0 Full Conversion INR
(c) One 3 Pin socket outlet point 5 Amps on the same board with other switches. 1 Per Point 0 Full Conversion INR
(d) One 3 pin socket outlet point 15 Amps on independent, with cables 2.5 sq. mm size . 3 Per Point 0 Full Conversion INR
(e) M&L all as per item No-38 above but for one 3 pin socket out let 16 Amps on Independent board with the cable 4.0 Sqmm and 4 Sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead medium grade with all fittings (ISI marked) for installation of ACs all as specified and directed by Engineer-in-Charge. 2 Per Point 0 Full Conversion INR
S&F sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA for single phase AC supply complete all as specified and directed by Engineer-in-charge. 1 Each 0 Full Conversion INR
Supply and fixing for energy saving environmental friendly, LED tubelight fittings 20 watts 4 feet (Aluminium body) long life, impact proof, surface/wall mounting IP 20 LEDs including PVC square block 02 Nos complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size with ceiling rose, complete all as specified and directed. 2 Each 0 Full Conversion INR
S&F Socket outlet modular type 6A 2/3 pin combined 2 module with suitable plate and cover, complete all as specified and directed. 10 Each 0 Full Conversion INR
S&F Socket outlet modular type 6A/16A 2/3 Pin combined 2 module with suitable plate and cover, complete all as specified and directed. 3 Each 0 Full Conversion INR
S&F Switch Modular type one way 06 amps 1 module with suitable plate and cover, complete all as specified and directed. 15 Each 0 Full Conversion INR
S&F Switch Modular type one way 16 amps 1 module with suitable plate and cover, complete all as specified and directed. 3 Each 0 Full Conversion INR
S & F ceiling rose surface bakelite 3 terminals, complete all as specified and as directed by Engineer-in-Charge. 6 Each 0 Full Conversion INR
Supply and fixing GI Bracket bent to shape fabricated with GI Pipe 40mm dia light grade 1.5m long including mounting clamps nut bolts, complete all as specified and directed. 4 Each 0 Full Conversion INR
Supply and fixing of street light with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics for building outside application with system wattage of 60W 230V AC outdoor type with a nominal efficiency 100 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non corrosive high-pressure die-cast aluminum with PF > 0.95. Lifetime of 50K hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. 4 KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance complete all as specified and as directed. 4 Each 0 Full Conversion INR
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed on walls/ceiling including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. 20 RM 0 Full Conversion INR
Supply install, commissioning and testing LT panel outdoor type both side openable, cubical type, double door, floor mounted, made out of 3.15mm thick MS sheet duly powder coated complete with aluminium bus bar 300 amps rating mounted on epoxy based post insulators duly drilled holes for connections, all as specified including necessary foundation grouted in PCC 1:2:4 for mounting the panel suitable for 415 Volts, 50 C/s 3 phase and neutral system and ,internal wiring with suitable size of PVC insulated copper cable, copper lugs comprising of following accessories:- (Stand of panel should be such that panel be 45 cm above the ground level and 30 cm below ground. Cost of stand, earthwork and installation be included in deemed rate.(O-Level) (A) Incoming:- (i) MCCB 100 Amp, Breaking capacity 36 KA, 4 pole -01 No (Main incoming) (ii) Digital multifunctional meter showing V,A,PF etc=01 No (iii) Indicating lamp LED (RYB) - 01 set of three (B) Outgoing:- (i) MCCB 63 Amp, Breaking cap 16 KA, 4 pole - 02 Nos (ii) Timer Switch for operation of street light along with suitable contactor complete - 01 No 1 Each 0 Full Conversion INR
S&F MCB protected socket PVC plastic base model with socket plug top and 32 Amp MCB SP 240 Volts enclosures with two pin and earth plug and socket complete all as specified and directed by Engineer-in-Charge. 2 Each 0 Full Conversion INR
Supply and install hi wall split AC indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity 2.0 TR of BEE 3 star rating minimum, single phase and Digital Inverter twin rotary complete with mounting arrangements all as specified and as directed by Engr-in-Charge. 2 Each 0 Full Conversion INR
Supply and install 5.0 KVA Voltage stabilizer suitable for Air conditioner 2.0 TR having voltage range 90-300 volts I/C outgoing stabilized at 230 Volts+/- 5% tolerance complete all as specified. 2 Each 0 Full Conversion INR
S&F drain pipe PVC of size 15 mm 3 Mtr long, complete all as specified and as directed. 2 Each 0 Full Conversion INR
Supply and install copper tubing of size 5/8" and 1/4" of superior quality with a thickness greater than 0.7 mm for connecting the outer unit to the inner unit in a split-type air conditioner. This includes brazing and jointing work, ensuring all connections are secure and leak-proof, complete all as specified and as directed. 10 Ft 0 Full Conversion INR
Supply and wrapping of insulation on and around suction and discharge copper tubing of size 3/8" and 5/8" with 6 mm thick flexible corrugated thermocool, heat resistant, for split type AC complete all as specified and directed. MAKE : SUPREME INSUFLEX / AEROFOAM/SUPERLON 10 RM 0 Full Conversion INR
S&F for outdoor unit wall mounting bracket stand suitable for 1.5/2.0 ton capacity split AC outdoor unit, all as per specified and directed. 2 Each 0 Full Conversion INR
M&L for tin shed structure over the wall mounted outer unit of split ac to protect it from rain/snow all as per specified and directed by Engineer-in-charge. 2 Each Job 0 Full Conversion INR
S&F MCB Distribution board, Triple pole and neutral 415 Volt, 04 way, type With 200 Amps bus bar, complete all as specified and directed. 1 Each 0 Full Conversion INR
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB, complete with connection testing and commissioning. (a) SP 5 To 32 AMP 8 Each 0 Full Conversion INR
(b) SPN 40 to 63 AMP 2 Each 0 Full Conversion INR
(c) TPN 63 Amp 1 Each 0 Full Conversion INR
Supply and fixing 36 watts recess /surface mounting LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser IP20, all as required at site and as specified and directed by Engineer-in-charge. 9 Each 0 Full Conversion INR
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 4 core including making electrical connection with thimbles, complete all as specified and directed. 25 RM 0 Full Conversion INR
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil, complete all as specified and directed. 10 Cum 0 Full Conversion INR
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed. 8 Cum 0 Full Conversion INR
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified& directed. 2 Cum 0 Full Conversion INR
Supply and laying of DWC (Double wall corrugated) pipe, ISI marked, having outer dia as 63 mm and inner dia as 50 mm for non pressure under ground cable including all connected accessories/ fittings such as coupler, 'O' ring and suitable nos of clamp to fix with wall/ roof/ ceiling if required at site etc. for protection of cable, complete all as specified and directed by Engr-in-Charge. 10 RM 0 Full Conversion INR
Supply and installation of advance maintenance free Single rod earthing system by boring the required nos of holes of dimension 8 to 10 inch wide and length of hole should be less than approximately 2 inches of the electrode length in semi hard soil or hard soil consisting of one Nos UL 467 listed CPRI tested Pure copper tube earth electrode designed in accordance to IS:3043(1987).The system consists of copper tube earth electrode having purity of 99.99%.There is a copper strip inside it which is pressure filled with highly conductive crystalline mixture of metal alloys and other conductive material. Both the ends of the electrode should be permanently sealed with the extended terminal having two holes at the top for connecting the earthing system to the equipment/load. The Copper tube earth electrode should be of outer dia 50 mm,thickness of rod 01mm and length 03 mtrs tested according to IEC 62561-2 including min 25 Kgs/electrode of earth enhancing compound (PROCEM) NABL certified enhancing compound should have restivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the environment and non corrosive to the earth electrode itself. Provision of the connector for connecting electrode with earthing conductor/strip including fastener having suitable size according to the electrode and earthing conductor dimensions. Note-copper strip of 7.5m length from earthing electrode to the test point is included in the quoted rate. The Earth pit inspection chamber should be as per IEC 62561-5 or latest and will be of 300x300x300 mm inside dimension of RCC with 50 mm thick and fine finish all as specified and directed by Engineer-in-Charge. 3 Each 0 Full Conversion INR
Supply & Fix single pointed Copper air termination rod, 12 mm dia, 300 mm long all as specified and directed. 2 Each 0 Full Conversion INR
S & F Copper strip 20 X 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. 20 RM 0 Full Conversion INR
M&L for Earth Test point terminal block made of Gun metal or Phosphorus Bronze size 75x75x25mm drilled and screwed including 3Nos 8mm dia 25mm long Hex Headed Screw, all as specified and directed. 3 Each 0 Full Conversion INR
Supplying and laying GI tubing light grade fixed to the wall/ ground of size 50 mm bore for cable protection, complete all as specified and directed. 20 RM 0 Full Conversion INR
S&F Universal data logger 8 Channel having USB facility to insert the pen drive to download data in excel format, universal input-RTD, thermocouple, 4-20ma. Operating temperature -10 to 60 degree and operating RH 0 to 95 %, panel mounted, 8000 Reading storage facility, all as specified and directed by Engr-in-Charge. 1 Each 0 Full Conversion INR
Supply and fix UPS with battery bank lithium ion for back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 05 KVA. 1 Each 0 Full Conversion INR
Point wiring for inverter/UPS light / fan/ socket with 1.5 sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable in existing conduit complete all as specified and directed by Engr-in-Charge, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete. 10 Per Point 0 Full Conversion INR
Point wiring for inverter/UPS light / fan/socket with 2.5 sqmm FRLS PVC insulated unsheathed copper conductor single core multi strand flexible cable in existing conduit complete all as specified and directed by Engr-in-Charge, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete. 6 Per Point 0 Full Conversion INR
Note :- An amount of Rs. 4078.50 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_866503.xls
BOQ • 1.36 MB
Tender16.pdf
Tender Documents • 2.07 MB
Download all tender documents and submit your bid