Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.0 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹7.4 L+₹28,008 (3.92%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | Rejected-Technical SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | - | Rejected-Technical DOCUMENTS NOT FOUND IN ORDER. NOT ENLISHED IN CATEGORY C(I) |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
2 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJAY KUMAR SINGH
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR AND MAINTENANCE OF SUMMER/COOLING APPLIANCES AND ALLIED WORKS AT MIL STN TALBEHAT
2023_MES_625529_1
AGE(I)/TBT/TOK-70/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
TALBEHAT MIL STN
8 documents required · 8 mandatory
₹500
Yes
AGE I TALBEHAT
₹14,000
Yes
27 Dec 2023
28 Oct 2023
4 Dec 2023
4 Nov 2023
2 Dec 2023
11 Nov 2023
Amount
Dismantling/Disconnecting of the sealed unit compressor of water coolers of any capacity, Air Conditioner window/split type of any capacity, Deep Freezers and refrigerators of any make and capacity complete all as specified and directed by Engr-In-Charge. Note: - Old unserviceable compressor/ retrieved material of any type will be issued to the contractor in schedule of credit.
Water Coolers :-
Supply and fixing of hermetical sealed unit compressor 60/120 Ltrs capacity (No KCJ 463) including charging of gas including testing of required pressure and flushing for water coolers complete all as specified and directed by Engr-In-Charge.
Supply and fixing hermetical sealed unit compressor for 40/80 Ltrs capacity (No KCJ 444) including testing of required pressure and flushing for water coolers complete all as specified and directed by Engr-In-Charge.
Replacement of blower/Fan motor SP 230 volts of capacity (1/35 HP) with blade complete all as specified and directed by Engr-In-Charge.
Replacement of float Valve, PTMT assembly complete with PVC ball with rod of size 15mm bore complete all as specified and directed by Engr-In-Charge.
Supply and fixing of chromium plated push cock of size 15mm bore with suitable check nut complete all as specified and directed by Engr-In-Charge.
Replacement of over load protector suitable for water coolers of any type complete all as specified and directed by Engr-In-Charge.
Supply and fixing starting capacitor 60/120 Mfd for water coolers of any type complete all as specified and directed by Engr-In-Charge.
Supply and fixing running capacitor 10/15 Mfd for water coolers of any type complete all as specified and directed by Engr-In-Charge.
Supply and fixing thermo stat switch for water coolers of any type complete all as specified and directed by Engineer-In-Charge
WINDOW / SPLIT Type Air Conditioners (1.5/ 2 Ton capacity).
Replacement of starting capacitor of capacity 50+6 Mfd all complete all as specified and directed by Engr-In-Charge.
Replacement of starting capacitor of capacity 60+2 Mfd all complete all as specified and directed by Engr-In-Charge.
Replacement of Running capacitor capacity of 45 Mfd capacity complete all as specified and directed by Engr-In-Charge.
S&F copper tube of size 1/2” bore complete all as specified and directed by Engr-In-Charge.
S&F copper tube of size 3/8” bore complete all as specified and directed by Engr-In-Charge.
S&F copper tube of size 5/8” bore complete all as specified and directed by Engr-In-Charge.
S&F insulating material for suction line tube type complete all as specified and directed by Engr-In-Charge.
Replacement of air dust cleaner for WINDOW type AC 1.5 Ton cap complete made of nylon complete all as specified and directed by Engr-In-Charge.
Replacement of air dust cleaner for SPLIT type AC 1.5 Ton cap complete made of nylon complete all as specified and directed by Engr-In-Charge.
S & F Rotary type compressor unit including charging of gas with Mafron R-22 including testing of required pressure and flushing for Split type/ window type AC of 2 Ton capacity complete all as specified and directed by Engr-In-Charge.
S & F Rotary type compressor including charging of gas with Mafron R-22 including testing of required pressure and flushing for Split / window type AC of 1.5 Ton capacity complete all as specified and directed by Engr-In-Charge.
S & F of blower motor for AC window 2 Ton type single phase 230 volts of size 1/8HP complete all as specified and directed by Engr-In-Charge.
S & F of blower motor for AC Split 1.5 Ton type single phase 230 volts of size 1/3HP complete all as specified and directed by Engr-In-Charge.
S&F capacitor 4/6 Mfd, suitable for 1.5 Ton AC blower motor complete all as specified and directed by Engr-In-Charge.
S & F of Fan motor outer unit for AC window 2 Ton /1.5 Ton type single phase 230 volts complete all as specified and directed by Engr-In-Charge.
S & F in Replacement of PCB suitable for Split / window AC 1.5 /2 Ton of any make complete all as specified and directed by Engr-In-Charge.
S&F electric panel of 1.5 / 2.0 TR AC units including making all electrical connections all as specified and directed by Engr-In-Charge.
S&F over load relay suitable for 1.5 / 2.0 TR capacity AC complete all as specified and directed by Engr-In-Charge.
Supply and Charging of Refrigerant gas Mafran-22 to window/split type AC/Water cooler for old compressor including testing of required pressure and flushing complete all as specified and directed by Engr-In-Charge. Note: Cylinder for refrigerant gas shall be arranged by the contractor at own arrangement and empty cylinder shall be taken back from the department after the use of refrigerant complete all as specified and directed by Engr-In-Charge.
Shifting of Split type 1.5 Ton AC complete with proper connection of outer and inner unit with gas charging if reqd all as specified and directed by Engr-in-Charge
Taking out defective sealed unit compressor of window/split type AC of capacity 1.5 TR of any make and transportation to company for repair and thereafter fixing back the repaired compressor of original make in the existing AC, including welding, brazing of gas pipe line, vacuum pressure for leakage & testing with charging of Refrigerant Gas and testing & commissioning of AC complete all as specified and directed.
REFRIGERATOR :-
S & F of hermetical sealed compressor unit including charging of gas with Mafron R-134 including testing of required pressure and flushing for 300 Ltr capacity refrigerator complete all as specified and directed by Engr-In-Charge.
S & F of hermetical sealed compressor unit including charging of gas with Mafron R-12 including testing of required pressure and flushing for 270 Ltr capacity refrigerator complete all as specified and directed by Engr-In-Charge.
S & F in replacement of thermostat switch for refrigerator of capacity 165/310 Ltrs complete all as specified and directed by Engr-In-Charge.
S & F in replacement of starting relay suitable for any capacity of refrigerator complete all as specified and directed by Engr-In-Charge.
S & F in replacement of door gasket set magnetic type complete for 165 to 310 Ltrs complete all as specified and directed by Engr-In-Charge.
S & F in replacement of freezer for refrigerator for 270Ltrs capacity complete all as specified and directed by Engr-In-Charge.
S & F in of electric bulb SP 230 volts screw/Pin type with base complete all as specified and directed by Engr-In-Charge.
S & F in Replacement of vegetable tray glass for 300 Ltrs capacity refrigerator (Set of 2) complete all as specified and directed by Engr-In-Charge.
S & F in replacement of vegetable box fiber glass for 165 to 310 Ltrs capacity Refrigerators (As per sample kept in E/M Yard ) complete all as specified and directed by Engr-In-Charge.
S & F top plug three pins 05 Amps complete all as specified and directed by Engr-In-Charge.
S & F over load protector for refrigerator of any capacity complete all as specified and directed by Engr-In-Charge.
Supply and fixing bio-metal switch for controlling refrigerant of any size/cap of refrigerators complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of PCB for 270 Ltr capacity refrigerator complete all as specified and directed
Supply and fixing in replacement of PCB for 310 Ltr capacity refrigerator complete all as specified and directed by Engr-In-Charge.
S & F of blower motor for Refrigerator type single phase 230 volts of suitable size complete all as specified and directed by Engr-In-Charge.
DESERT COOLERS:-
S & F in replacement of Submersible pump for Desert cooler 1.5 mtr head AC 230 Volt complete all as specified complete all as specified and directed by Engr-In-Charge.
S & F in replacement of fan motor Kit , single phase, 220 volts AC, 1/3 HP, complete with blade arm suitable for desert cooler all as specified and directed by Engineer-in-Charge.
Supply and fixing of wood wool pad of best quality complete all as specified and directed by Engr-In-Charge.
Supply and fixing speed switch Three speed suitable for desert cooler including wiring to existing system complete all as specified and directed by Engr-In-Charge.
S & F in replacement of front grill complete made out of 24 gauge MS sheet duly painted as per sample complete all as specified and directed by Engr-In-Charge..
M&L for dismantling of existing old unserviceable PGI/MS sheet water tank/tray and in replacement fabrication of Water tank/ Tray for desert cooler of 22 gauge PGI sheet of suitable size of desert cooler including one coat of red oxide primer and two coat of synthetic enamel complete all as specified and directed by Engr-in-charge .
S & F in replacement of side shutters of Desert coolers heavy duty made out of 24 gauge MS sheet suitable for existing desert coolers as per sample complete all as specified and directed by Engr-In-Charge.
Taking down to desert cooler of any make/capacity carefully without damaging, scraping old paint, completely and painted with 2 coat of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler and inner surface of bottom & sides painted with 2 - coat of silver gray paint completed all as specified and as directed by Engineer-in-Charge.
Supply and fixing PVC insulated copper conductor flexible cable of size 23/0.0076 heavy duty multi standard 3 core complete all as specified and directed by Engr-In-Charge.
M&L for rewinding of desert cooler motor, AC 220 volt, Single phase, 50 Hz, of any make, Model and vintage with super enamelled copper wire with same gauge and turn with and including top quality of insulation material such as varnish, cotton tape and sleeve etc., Including changing of two No. bushes, capacitor 4 mfd and shaft complete all as specified and directed by Engineer-In-Charge.
DEEP FREEZERS:-
Supply and fixing of hermetical sealed compressor unit including charging of gas with Mafron R-134 including testing of required pressure and flushing capacity for deep freezer 300/400 Ltrs. All as per Sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing of blower motor 1/ 9 HP 230 volt single phase complete all as specified and directed by Engr-In-Charge.
Supply and fixing Thermostat for Deep Freezer 200/300/400 Ltrs complete all as specified and directed by Engr-In-Charge.
Supply and fixing Top Gasket for deep freezer 200/300/400 Ltrs capacity complete all as specified and directed by Engr-In-Charge.
Supply and charging of refrigerant gas Mafron- R-134 to deep freezer/ Water cooler /Refrigerator for old compressor including testing of required pressure and flushing complete all as specified and directed by Engr-In-Charge. Note: Cylinder for refrigerant gas shall be arranged by the contractor at own arrangement and empty cylinder shall be taken back from the department after the use of refrigerant.
Dismantling of voltage stabilizer of 5/3/2 KVA Cap. for repair / replacement of U/S parts i.e. transformer ,relay , wiring and refixing after repair of damaged/U/S parts all as directed by Engr-in-Charge .
M&L for servicing of water cooler/ split AC/ Window AC/ Refrigerator of any capacity including replacement of unserviceable parts i.e. running capacitor ,starting capacitor complete all as specified and directed by Engr-In-Charge.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
m/s gupta trading
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .