Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC 16 20 GALI NO 7 8 SWAROOP NAGAR EXTENSION DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹4.0 L+₹51,464 (14.8%)Rejected-AOC | L2 | Rejected-AOC Other than lowest |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
31 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
Noida
REPAIR MAINTENANCE OF SERVO STABILIZER AND OTHER LT EQUIPMENT AT SEC 23 24 SEC 52 UNDER AGE I COAST GUARD NOIDA
2023_MES_593054_1
AGE I CGN 13 23 24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Noida
E b i
7 documents required · 7 mandatory
₹500
AGE I CG
₹12,000
13 Jul 2023
4 May 2023
2 Jun 2023
4 May 2023
31 May 2023
17 May 2023
Amount
Disconnecting electrical connections of Servo voltage stabilizer by taking out transformer oil and storing for reuse after cleaning and removing moisture, taking all the assembly of voltage stabilizer and removing / repairing the unserviceable parts, reassembling it after repair testing and commissioning the voltage stabilizer of following capacities:- Note:- (i) Spares required for replacement of unserviceable parts shall be measured and paid separately under item of this BOQ of scheldule as supply only and cost shall be deemed to be included in unit rate for this item. (ii) Cost of transportation, loading, unloading from site to workshop & back including its installation, testing & commissioning complete is included in the quoted item rate.
Supply only PCB control card for automatic voltage correction suitable for voltage stabilizer of following capacities:
Supply only carbon bushes for voltage stabilizer of following capacities:
Supply only servo motor for voltage stabilizer of following capacities:
Supply only Cast Iron dimmer gear set for automatic voltage correction for servo voltage stabilizer of capacities:
Supply only Servo Dimmer Booster coil for automatic voltage correction suitable for servo stabilizer of following capacities:
Supply only super enamelled copper conductor winding wire of same guage including necessary insulating materials for servo voltage stabilizer of capacities 30 KVA to 500 KVA.
Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge copper conductor as per existing winding for stabilizer of capacity 30 KVA complete all as specified and directed.
Supply and fixing in replacement Changover switches with 1 P 2W with centre Off upto 16 Amps complete all as directed . Make :- L & T or equivalent as approved.
Supply and fixing in replacement Digital Temp indicator Square type suitable for Servo Voltage stabilizer complete all as directed
M&L for filtration / dehydration of insulating oil of transformer in position to achieve dielectric strength 50 KV or above (when tested with 2.5 mm gap electrode) complete all as directed.
Supply only new transformer oil, clear, transparent and free from all type of suspended matter or sediment, ISI marked as per IS:335/93 with amdt. No.1 (Reaffirmed: 2005) dehydrated to give BDV value not less than 60 KV when tested with 2.5 mm gap electrode for topping up complete all as directed. Make :- Savita / Powerlink / Power oil as approved.
M & L for Preparation of old painted iron surfaces of the Voltage Stabilizer 30 KVA (out side body) up , by scraping old paint surface, cleaning and applying two coats of automotive paint by spray painting including denting and filling with putty complete all as directed by EIC and specified.
M & L for Preparation of old painted iron surfaces of the Voltage Stabilizer 500 KVA (out side body) up , by scraping old paint surface, cleaning and applying two coats of automotive paint by spray painting including denting and filling with putty complete all as directed by EIC and specified.
M & L for Dismantling of LT cable of Different Sizes,cutting of unservicable lugs ,glands etc and making insulation by insualtion tapes of different color and providing the new lugs and doublle compression type cable Glands etc complete all as specified and directed. Note:- Cable glands and lugs will be measured and paid seperately
Supply only Double compression type brass cable glands of following size cable : Make : Dowell's or equivalent
(a) 400 Sqmm 3.5 core
(b) 300 Sqmm 3.5 core
(c ) 120 Sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(d) 35 Sqmm 3.5 core
(e) 25 Sqmm 4 Core
Supply only Aluminium LugsLong barrel type of following size cable : Make : Dowell's or equivalent
(a) 400 Sqmm 3.5 core
(b) 300 Sqmm 3.5 core
(c ) 120 Sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(d) 35 Sqmm 3.5 core
(e) 25 Sqmm 4 Core
Taking down old unserviceable voltage stabilizer and Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA Make V Guard VWR 400 or equ in
Labor for cleaning the vegetation / surplus soil around the earth pits upto 1.00 mtr all around the pit , cleaning the chamber of the earth pit, replacing the rusted earthing leads / funnel with mesh etc checking the results of the earthing using earth tester, re-activating the earth pit using suitable measures as required to bring the results within the limits of 1 ohm all as directed by engineer-in charge. NOTE :1) All materials required for re-activation of earthing will be measured and paid separately under respective item of respective item of schedule. 2) The resistance of earth pits to be carried out once in three months. 3) Contractor has to provide details of Earthing cleanng job with users Signature
supply of common salt
Supply of magnesium sulphate
M&L for earthing complete with galvanized steel earth plate electrode 90cmx60cm x 5 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 32x6mm as earth lead up to 7.5 mtr length by means of bolts, nuts check must and washers etc. of galvanized iron or steel all as shown in electrical plate No. 3 including provn of GI protection pipe light grade of 40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.3 of SSR part - I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs test point etc.
S & F in replacement copper strip 32 x 6mm buried in ground duly connected to earthing etc all as directed by engineer-in-charge
M & L for Overhauling, servicing, Testing of ACB 800Amps/630 Amps including the following:- (i) Primary injection test, & Release test (ii) All types of RELAY - Testing, servicing & certification at site,Check condition of arcing contact and gap between fixed and moving arcing contacts shall be checked. (iii) Checking the reset mechanism, tripping of breaker through push button,Tripping of ACB manually through volt metric release. (iv) Checking tripping of ACB through protection release, (v) Checking and adjust freeness of DN and volt metric release trip rod, (vi) Checking presence and proper tightening of hardware. Checking condition and alignment of jaw contact with cradle terminals, (v) Checking and adjusting gap between hylam sheet and side plate, (vi) Checking ACB tripping through shunt release. Note :- The Servicing Shall be carried out from OEM of ACB ,necessary test certificate has to be submitted
S & F in replacement of HRC Fuse base of capacity 250-315 Amps
S & F in replacement HRC fuse link of capacity 250-315 Amp complete all as directed
S & F in replacement MCCB's,415 Volts , 4 pole/3 pole , with adjustable thermal & fixed magnetic settings having following capacities :-.( Make:- Havells or equivalent in Schneider/ L& T/ABB)
(a) 63 Amps 16 KA,3 Pole
(b) 125 Amps 16 KA,3 Pole
(c) 160 Amps 16 KA,3 Pole
(d) 200 Amps 25 KA,4 pole
(e) 315 Amps 25 KA
(f) 400 Amps 50 KA
M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing (Make :- M seal/Recham /Denson) complete for : -
(a) Cable size 150 to 185 Sqmm, 3.5 core
(b) Cable size 70 to 120 Sqmm, 3.5 core
(c) Cable size 25 to 50 Sqmm, 3.5 core
BLUE HILL ELECTRICAL AND ELECTRONICS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .