Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC Quoting lowest rate | |
| 2 | L2₹15.2 L+₹1.4 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹16.1 L+₹2.3 L (17.0%)Rejected-Finance 114 4 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance Quoting Higher rate |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
17 Feb 2021, 1:00 pmClosed
Executive Engineer,PWD, Electrical Constn. Divn.
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Construction of 5th floor over the G IV storied New Academic Building and Group - D staff Quarter -cum-Guest room building for Dinabandhu Andrews College in Kolkata.
2021_PWDE_322706_1
WBPWD/ECD/eNIT10/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Garia
Please refer tender documents
4 documents required · 4 mandatory
₹36,000
2 Dec 2021
3 Feb 2021
19 Feb 2021
3 Feb 2021
17 Feb 2021
3 Feb 2021
3 Feb 2021 - 17 Feb 2021
Amount
Supply of Cable Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. (Make:- As per direction of EIC) 2 core 6 sq. mm.
4 core 35 sq. mm.
4 core 50 sq. mm.
Laying on Wall / surface with Saddles / clamps Laying of cable of the following size concealed on wall / surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. Mending good damages and painting Upto 2 Core 25 sqmm
From 3/3½/4 core 35 sqmm to 50 sqmm
Laying through RCC / Hume / GI Pipe Laying only Cable upto 50 sqmm through existing RCC / Hume / GI Pipe / open masonary trench for single, 2, 3, 3½ & 4 core
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of the following XLPE/PVC armoured cable as per GS. 2 core 6 sq. mm.
4 core 35 sq. mm.
4 core 50 sq. mm.
Finishing the end of the XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials as per GS 2 core 10 sq. mm.
4 core 35 sq. mm.
4 core 50 sq. mm.
Supplying and fixing upto 160 A 4 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( Make-Legrand )
Supplying and fixing 4 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand)
Supplying and fixing double door sheet steel (16SWG), powder coated cable/wire end box for 4 way Horizontal TPN DB enclosure with IP-42/43 protection, concealed on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make- Legrand )
Supplying and fixing double-door (2+12) Way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment..(Make-Legrand )
Supplying and fixing double door sheet steel (16SWG), powder coated wire way box suitable for (2+12) way SPN MCB DB enclosure with IP-42/43 protection, concealed on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make-Legrand )
S&F 415 V , 200A 4- Pole MCCB of Breaking capacity 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS (Make-Legrand )
Supply & fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make-Legrand ) 63A FP MCB
63A TP MCB
32A TP MCB
40A DP MCB
6-32A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick ploythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 3 nos. suitable "Ph , N & E" copper bar with top cover plate making earthing attachment fixed on wall including mending good damages to original finish. [only PVC Rigid conduit on ceiling and remaining portion concealed]. as per GS. On board 5A
Average run: 6 Mtr.
Average run: 8 Mtr.
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Fixing of the following size PVC Rigid conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (a) 20mm size
(b) 25mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulate & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required.as per GS 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make-Legrand ) 2 Way
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. As per GS 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc as per GS
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc as per GS.
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with separate 2 nos. 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate complete with 3 nos. suitable "Ph , N & E" copper bar with top cover plate making earthing attachment fixed on wall including mending good damages to original finish. as per GS
Supply & Fixing 240 V, 2 nos. 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with separate 2 nos. 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover platecomplete with 3 nos. suitable "Ph , N & E" copper bar with top cover plate making earthing attachment fixed on wall including mending good damages to original finish. as per GS.
Supply & Fixing modular type Blank Plate on existing GI / PVC modular switch board with modular cover plate.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
S&F 240 V, 25A modular plug socket (Brand approved by EIC) on 2-module sheet metal board, with 25A plug top & indicator, embedded in wall incl. cover plate and making necessary connections as required.
Fixing only lamp.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire.
Fixing only cabin/wall fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Fixing only following exhaust fan after making hole in wall and making good damages and smooth cement finish etcx. As practicable as possible and providing necy. Length of PVC insulated wire and making connection for exhaust of following diameter. (b) 30 cm. (12")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm. Exhaust fan (12")
37.5 cm. Exhaust fan (15")
Supply and Fixing EI danger board on wall" 20cm x 30cm (8" x 12")
Supply and Fixing angular batten holder (Anchor)on 75mm dia PVC round block/ round bakelite on wall/ceiling.
Supplying and Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 15 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S & F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.29 ]
Fixing LED downlighter lifgt fitting for aesthetic look , complete with all accessories directly on false ceiling.
Earthing Installation – with Pipe Electrode : Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By TATA-Medium GI pipe
Earth Busbar Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Earth Continuity Strip Connecting the equipments to earth busbar including S & F 25 mm x 6 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc.
Fittings & Fixtures etc. Supply of following fan etc. as complete in all respect. Ceiling Fan (Orient/ Usha / Crompton Grieves) - 5 star rating as per BEE (a) 1200mm sweep
Wall Bracket Fan complete metal body and metal blade - 400mm sweep (Orient/ Usha / Crompton Grieves)
Supply of following Exhaust Fan complete metal body and metal blade - (Orient/ Usha / Crompton Grieves) (a) 300mm sweep
(b) 375mm sweep
Supply of following Light Fittings with Lamps (Make- Philips) a) Philips Cat No. : BN021C LED 20S PSU as required to complete set.
b) LED twin Tube light Fittings with 2 nos MAS LED tube 1200mm 18W 2100 lm each tube (Philips Cat No. : TMC 501 P 2xT-LED 22W P3242) as required to complete set.
c) Philips Cat No. : RC380B LED34S-6500 G3 PSD OD as required to complete set.
d) Philips Cat No. : DN296B LED20S 6500 PSU WH as required to complete set.
e) Philips Cat No. : DN296B LED10S 6500 PSU WH as required to complete set.
d) Philips Cat No. :BVP410 LED 165 CW HE SY20 FG S3 XTFC as required to complete set.
Philips: 9 W LED Bulb
S&F double door 4-Way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall incl. Inter connection & provision for earthing attachment (Make-Legrand )
Supplying and fixing 100A 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make: Legrand)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 40 A TP MCB
6-32A SP MCB
S & F 4 pole MCB enclosure with 1 no. 415 V 40A 4 pole MCB (Make-Legrand )
S & F 2 pole MCB enclosure with 1 no. 240 V 16A 2 pole MCB (Make-Legrand ) onwall.
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 9watt LED lamp complete set.
Supply & Laying of 1.1 KV grade XLPE insulated & armoured cable of 4 core 16 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE armoured cables incl finishing of the XLPE insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc .4 core 16 sqmm
Supplying & Fixing of 230 V 1 no 6A plug with switch in suitable size MS box with backelite cover on wall.-FOR LIFT.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x2.5 sqmm + 1 x 1.5 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2 x2.5 sqmm + 1 x 1.5 sqmm
S&F EPC make 12" Heavy Duty sweep A.C Exhaust fan incl. making hole on wall with nuts & bolts of required with S&F of Alluminium coul. (Make-Legrand )
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe
S&F earth busbar of galvanized (Hot Dip) MS flat on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required S&F galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall
Connecting the equipments body to earth busbar including S&F galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat
Supplying and fixing 415V, 32 A TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
SHATABDI ENGINEERING AND CONSULTANCY
NEW INDIA ELECTRICAL AND ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .