Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹570Qualified Make: Mastech
Model: MASTECH 830L 24 G JYOTISH ROY ROAD NEW ALIPORE KOLKATA 700053 CALCUTTA SOUTH DIVISION WEST BENGAL 700053 INDIA | KOLKATA | WEST BENGAL | 700053 | Make: Mastech
Model: MASTECH 830L | L1 | Qualified | |
| 2 | Disqualified Make: Motwane
Model: DM3540A AIRTECH ENTERPRISES JE 9 105 FIRST FLOOR OPPOSITE M BLOCK TIKONA PARK MALVIYA NAGAR NEW DELHI 110017 SOUTH DELHI | SOUTH DELHI | DELHI | 110017 | Make: Motwane
Model: DM3540A | - | Disqualified | |
| 3 | Disqualified Make: FLUKE
Model: FLUKE 101 HOUSE NO 24 BHAGAT SINGH MARG POLO II MANDORE ROAD JODHPUR RAJASTHAN RAJASTHAN 342001 | JODHPUR | RAJASTHAN | 342001 | Make: FLUKE
Model: FLUKE 101 | - | Disqualified | |
| 4 | Disqualified Make: FLUKE
Model: Fluke 101 7 MB 250 I G NAGAR JAIPUR JAIPUR JAIPUR CITY SOUTH RAJASTHAN 302025 | 302025 | Make: FLUKE
Model: Fluke 101 | - | Disqualified | |
| 5 | Disqualified Make: RISHABH
Model: Rishabh 615 F 31 MIDC SATPUR NASHIK CITY MAHARASHTRA SATPUR MIDC NASHIK NASHIK MAHARASHTRA 422007 | NASHIK | MAHARASHTRA | 422007 | Make: RISHABH
Model: Rishabh 615 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Jul 2018, 6:00 pmClosed
digital multimeter Experience with Gov. Required 3 Year (s) Digital Multimeter ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type Average Average
True RMS Counts 6000 4000
6000
50000
2000 00 MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 0.1 0.005
0.05
0.1
0.5
1 DC Voltage resolution 10 0.001
0.01
1
10
10 0 AC Voltage Range 1000 600
1000 AC Voltage Accuracy 0.1 0.08
1 AC Voltage resolution 10 0.001
10 0 DC Current Range 10 3
10 DC Current Accuracy 1 0.005
1.5 DC Current resolution 1 0.001
10 0 AC Current Range 10 3
10 AC Current Accuracy 1 0.5
1.5 1/5 AC Current resolution 1 0.001
10 0 Resistance Range 100 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 1 0.001
10 0 Capacitance Range ( Micro farad ) NA 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) NA 1.5
3.5
5
NA Capacitance resolution ( nF ) NA 0.001
10 0
NA Frequency Range ( KHz ) NA 50
200
300
NA Frequency Accuracy ( % ) 1 0.1
NA Frequency resolution ( Hz ) NA 0.001
NA Temperature Range ( Degree C ) -40 to 400 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) NA 1.5
NA Temperature resolution ( Degree C ) NA 0.001
NA OTHER FEATURES Continuity test and Diode test Not Available - Data logging Not Available - If Data Logging Feature is Available
Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) NA - Weight 500 - Other Features NA - SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 2/5 61010
Category IV 1000 V of IEC 61010 Safety Certification UL - POWER REQUIREMENTS Power Requirements 230 V +/-10% AC
50 Hz +/- 3% through Adaptor - if Battery Operated
then Type of Battery NA - if rechargeable
then chemistry of the battery NA - if Non-rechargeable
then size of the battery cell NA - number of non- rechargeable the battery/cell NA - Voltage of rechargeable Battery 1000 - capacity of rechargeable battery(milli Ampere Hour) 1000 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment NA - WARRANTY Warranty 1 1
5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Condition 50 - Operating Humidity (RH) 95 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 true - 3/5 0/part-2/section-4/1977 latest conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test NA - Name and address of the Lab for the specification test NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Reenu Tanwar N 110011
Jt Dir SI-1
Room No-950
ADGSI(SI-1)
9 th Floor
A Wing
Sena Bhawan 1 15
312785
GEM/2018/B/44371
digital multimeter
15 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Experience with Gov. Required 3 Year (s) Digital Multimeter ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type Average Average | - | - | - |
| True RMS Counts 6000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 2000 00 MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.1 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 10 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 10 0 AC Voltage Range 1000 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.1 0.08 | - | - | - |
| 1 AC Voltage resolution 10 0.001 | - | - | - |
| 10 0 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 1 0.005 | - | - | - |
| 1.5 DC Current resolution 1 0.001 | - | - | - |
| 10 0 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 1 0.5 | - | - | - |
| 1.5 1/5 AC Current resolution 1 0.001 | - | - | - |
| 10 0 Resistance Range 100 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 1 0.001 | - | - | - |
| 10 0 Capacitance Range ( Micro farad ) NA 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) NA 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) NA 0.001 | - | - | - |
| 10 0 | - | - | - |
| NA Frequency Range ( KHz ) NA 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) NA 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -40 to 400 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) NA 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) NA 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Not Available - Data logging Not Available - If Data Logging Feature is Available | - | - | - |
| Internal Memory NA - Computer Interface along with software Not Available - Dimensions ( mm X mm X mm ) NA - Weight 500 - Other Features NA - SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 2/5 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL - POWER REQUIREMENTS Power Requirements 230 V +/-10% AC | - | - | - |
| 50 Hz +/- 3% through Adaptor - if Battery Operated | - | - | - |
| then Type of Battery NA - if rechargeable | - | - | - |
| then chemistry of the battery NA - if Non-rechargeable | - | - | - |
| then size of the battery cell NA - number of non- rechargeable the battery/cell NA - Voltage of rechargeable Battery 1000 - capacity of rechargeable battery(milli Ampere Hour) 1000 - Suitable charger adaptor provided NA - ACCESSORIES Standard Accessories Supplied with the Equipment NA - WARRANTY Warranty 1 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Condition 50 - Operating Humidity (RH) 95 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 true - 3/5 0/part-2/section-4/1977 latest conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test NA - Name and address of the Lab for the specification test NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Reenu Tanwar N 110011 | - | - | - |
| Jt Dir SI-1 | - | - | - |
| Room No-950 | - | - | - |
| ADGSI(SI-1) | - | - | - |
| 9 th Floor | - | - | - |
| A Wing | - | - | - |
| Sena Bhawan 1 15 | - | - | - |
Exempted
15 Jul 2018
10 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_312785.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .