| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC INDEX NO B 33 NC R O KRALPORA DISTT BUDGAM SRINAGAR J K 190019 | SRINAGAR | BUDGAM | JAMMU AND KASHMIR | 190019 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.3 L+₹2.0 L (7.03%)Rejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹31.2 L+₹2.8 L (10.0%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹31.3 L+₹3.0 L (10.4%)Rejected-Finance NA | NA | NA | 121004 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹31.8 L+₹3.4 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹41.1 L
EMD Value
₹82,200
Closing Date
30 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA BATHINDA MIL STN PIN-151004
SPL REPAIR TO BLDG NO T-10, T-15, T-17, T-21, T-24 AND T-25 AT WEU (OLD LOC) UNDER AGE BR-III AND AGE EM OF GE NORTH BATHINDA AT BATHINDA MIL STN
2022_MES_521440_1
8937/NIT-05/22-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BATHINDA
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹82,200
Yes
13 Jun 2022
2 May 2022
1 Jun 2022
2 May 2022
30 May 2022
18 May 2022
2 May 2022 - 9 May 2022
60 days
Amount
SCHEDULE 'A' B/R Works
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc., including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of door frames,chowkhats of pressed steel and in bed blocks and like etc. complete all as specified and as directed by Engineer-in-charge.
Supply & fixing factory made 2nd class hardwood, rail and style, thickness of shutter 35mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treate, complete all as specified and as directed by Engineer-in-charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge.
Supply and fixing mild steel barrel tower bolt, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 200mm, oval type stove enamelled black complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing by welding or riveting complete all as specified and as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & as directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 4mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material, oil putty complete all as specified & directed by Engineer-in- charge.
Supply and fixing in replacement mild steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod complete all as specified & directed by Engineer-in- charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying 3mm thick wall putty upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Supply and fixing Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with 'L' type or 'J' type or cranked hook bolts/fixed with screws and rubber washer, including dismantling existing AC sheet or any other type of sheet, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in Gate covering/ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws, including dismantling existing AC sheet or any other type of sheet, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications, including dismqantling existing ceiling board, complete all as specified and as directed by Engineer-in-charge.
Material and labour for providing precast cement concrete type B-0 (1:2:4), 12.5mm graded aggregate as in louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4, including dismantling old existing jallies etc., complete all as specified and as directed by Engineer-in-charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) including making good excess taking down plaster area (above skirting tile ) complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by the Engineer-in-Charge.
Demolition stone/marble slabs of any description or thickness as in floors/ cooking platform/steps/Interlocking tiles/brick tiles etc. laid bedded and pointed in any mortar including removing rubbish material from the site complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles/in trenches for cable protection, interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour welding in repairs not exc. 2.5cm in length and not exc. 6mm in thickness, complete all as specified & directed by Engineer-in- charge.
SCHEDULE 'A' ELECTRIFICATION WORKS
Taking down carefully existing unserviceable copper/aluminium point wiring (light/fan/socket or power point) complete with all accessories such as hylum sheet, switches, sockets, ceiling rose, wall brackets, regulator gang boxes etc & making good distrubed surfaces of walls/floor etc and matching with existing surface all as specified and directed by Engr - in- Charge
Material and labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly etc., including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3 ) to matching with existing surface complete all as specified and as directed by Engineer-in-charge. Make of cable and conduit :- Havellls/Dcab/Finolex/Anchor
All as per item No 48 here in before but for socket outlet 5 pin 5 Amp on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 48 here in before but for socket outlet 5 pin 5 Amp on independent board but not below the switch board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No 48 here in before but for socket outlet 6 pin, 5/15 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush type , single pole, one way, 15/16 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Batten holder 2 Amp 250V AC with skrit ISI marked top line series , polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb, complete all as specified and as directed by Engineer-in-Charge. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply and fixing wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing New generation energy saving long life versatile pressure die -cast aluminium IP 66 roadway luminaire with high power LED of 25 watt with toughened glass complete with GI bracket suitable for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing, including taking down old unserviceable light fittings any type complete, complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing Air Circulator Wall Mounted Fan 400 mm sweep, metallic body having copper winding, single phase, 230 volts 50 Hz double ball bearing energy efficiant, three curvy metal blades / Aerodynamically designed blades with fine finishing, Rigid frame for protection from foreign matters /Sturdy close-mesh guards and Highly powerful motor for high air thrust including fixing material including electrical connection complete all as specified and directed by Engineer-in-Charge Make - CROMPTON /USHA/HAVELLS/KHAITAN
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq mm 2 core including taking down unserviceable Service cable from pole to bldg all as specified and directed..
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
N.G BUILDERS
V K CONTRACTOR
M/s Goyal Builders
KARTIK BUILDERS
M/s Vandana Builders
SHARDA ENTERPRIES
M K Enterprises
M/s MITTAL CONSTRUCTIONS
Easyways Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .