Loading…
Loading…
Tender Value
₹62.0 L
EMD Value
₹1.2 L
Closing Date
13 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Electrical work in connection with the work of "AAP-SB : Provision of water supply arrangement with summersible pump at way side colony under ADEN/ETW.".Electrical work in connection with the work of "Firozabad- Construction of underground water tank connected with JEDDAH JHAL Pariyojana at Firozabad station.".Electrical work in connection with the work of "Construction work of RPF POST PHD Office ."
ELG-28-2627
ELG-28-2627
Open
6 Months
Firozabad, Uttar Pradesh
₹0
₹1.2 L
19 Jun 2026
19 Jun 2026
29 Jun 2026
Item Breakup - 1-NS Schedule
Wiring for circuit / sub main wiring along with Metre earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 4 sq. mm+ 1 x 4 sq. mm earth wire.Inspection by- Consignee PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Wiring for circuit / sub main wiring along with Metre earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 6 sq. mm+ 1 x 6 sq. mm earth wire.Inspection by- Consignee
Wiring for circuit / sub main wiring along with Metre earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 10 sq. mm+ 1 x 10 sq. mm earth wire.Inspection by-Consignee
Wiring for light/power plug with 2x4 sq.mm FRLS Numbers 350.00 PVC insulated copper conductor single core cable insurface/recessed medium class PVC conduit, along with 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Inspection by- Consignee.
Supply, Erection, Testing and Commissioning of Numbers 150.00 following Modular Type switch 10 A (1-way) complete in all respect. Inspection by-Consignee
Supply, Erection, Testing and Commissioning of Numbers following Modular type Plug socket outlet 2/3 Pin 10 A complete in all respect.Inspection by- Consignee
Supply, Erection, Testing and Commissioning of Numbers following Modular Type switch 20 A (1-way) complete in all respect. Inspection by-Consignee
Supply, Erection, Testing and Commissioning of Numbers following Modular type Plug socket outlet 5/3 Pin 20 A complete in all respect. Inspection by- Consignee
Supply, Erection, Testing and Commissioning of Numbers following Modular type step type Electronic Fan Regulator complete in all respect.Inspection by- Consignee
Supply and Erection of Junction Box cover POP Numbers 300.00 type complete in all respect including hardware material for fixing.Inspection by-Consignee
Supply and Erection of Modular type switch Numbers blanking set to fill the blank space White finished mounting cover plate complete in all respect. Inspection by-Consignee
Supply and Erection of white finish single Numbers mounting cover plate with base frame suitable 3 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. Inspection by-Consignee
Supply and Erection of white finish single Numbers mounting cover plate with base frame suitable 8 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. Inspection by-Consignee
Supply and Erection of white finish single Numbers mounting cover plate with base frame suitable 12 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. Inspection by- Consignee
Supply and Erection of Modular Metal boxes Numbers concealed Boards suitable for mounting of 3 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall.Inspection by- Consignee PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply and Erection of Modular Metal boxes Numbers concealed Boards suitable for mounting of 8 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall. Inspection by- Consignee
Supply and Erection of Modular Metal boxes Numbers concealed Boards suitable for mounting of 12 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall. Inspection by- Consignee
Supply and Installation of Ceiling rose 3 plate as Numbers per IS No. 371/1999 (Latest Version) including connections, Testing and commissioning as per Tech. Specification. Inspection by-Consignee.
Supply and Erection of Fan Box cover POP type Numbers complete in all respect including hardware material for fixing. Inspection by-Consignee.
Termination of LT XLPE cables of various sizes Job (One Job means all 4 cores of cables). Inspection by-Consignee.
Supply, Installation, Testing and Commissioning Numbers of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Inspection by- Consignee.Inspection by-Consignee
Supply and laying of B class, 50 mm dia, GI pipe Metre of for cable riser/road crossing as required and as per relevant technical specification. Inspection by- Consignee. Inspection by- Consignee.
Collecting, Transporting from SSE/PS/ store to Metre site, laying, testing, and commissioning of above LT cable . Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/required in wall/in concrete floor by cutting recessed and finished originally as required as per relevant technical specifications.
Drilling of bituminous road/track and laying Metre charges of cable in road crossing for laying 110 mm dia HDPE pipe through it.
Supply and laying of HDPE Pipes (Upto PN 8.0 Metre Pressure Rating Material Grade: PE 63, Pressure Rating: PN 8.0, Nominal Dia(mm): 110) as per IS- 4984:2016 suitable for HT/LT XLPE cable & as required and as per relevant technical specification. Inspection by-Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Design, Manufacturing, Supply, Erection, testing Numbers and commissioning of LT switchgear panel board of 02 mm Tk. Dia pressed CRS steel sheet panel shall be treated for anti corrosion treatment and finished with smoke gray paint as per technicalspecification no. Sr.DEE/G/ALD/Panel- 94/113 Comprising with as under:-........MCCB of 400 A, 36 kA Standard breaking capacity, 415 volt, 3 Phase 4 Pole current rating 400 Amp.
MCCB of 250 A, 36 kA Standard breaking Numbers capacity, 415 volt, 3 Phase 4 Pole current rating 250 Amp.
MCCB of 125A, 36 kA Standard breaking Numbers capacity, 415 volt, 3 Phase 4 Pole currentrating 125 Amp.
MCCB of 63A, 36 kA Standard breaking capacity, Numbers 415 volt, 3 Phase 4 Pole current rating 63 Amp.
Supply of Indicator lamps with suitable holder.
Supply, commissioning of Outgoing/Feeder Panel Mounted Multi-function Mtrs. with Accuracy Class 1 as per IEC 62053-21 or Class 0.5, 0.5S as per IEC 62053-22.LED Mtrs. Cl 1 with RS485: Mtrs. should have following features built-in LED • Flush mounting 96 x 96 mm • True RMS measurement • Password protection provision for security • Site selectable for 3 Phase 4 wire, 3 Phase 3 wire, 1 Phase, CT Secondary 1A/5A, Universal Auxiliary Supply 80-300 VAC/DC, Input Voltage Measurement 50-500 VAC, 64 samples/ cycle The Mtrs. should be able to read/display following paraMtrs.s Instantaneous ParaMtrs.s (V1, V2, V3, V12, V23, V31, Avg (VLN, VLL), A1, A2, A3, Aavg, F, PF-1, PF-2, PF-3, PF (Avg) W1, W2, W3, W (total) VA1, VA2, VA3, VA (total) Cumulative ParaMtrs.s (Import Wh, Import Vah, Import load hours, Reset (old) Cumulative paraMtrs.s (Import Wh, Import load hours, Communication (RS485 Modus RTU). complete with all accessories.
Fabrication works and insulated Aluminum bus Numbers bars of 800A capacity for phases & 800A capacity for neutral Bus bar shall be suitably insulated with heat shrinkable sleeves/ epoxy coating/insulating tap to withstand the test voltage of 2.5 KV Copper strip for connection outgoing as well as incoming with suitable size be provided. item no. 26 to 32 Inspection by- Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, replacement, fixing, testing, connecting Numbers 144.00 and commissioning of energy efficient luminaries complete with all accessries of capacity 18/20 watt, 4 feet length, T8 LED lamps with sutable current control driver circuit ,suitable for surface/recessed mounting.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and potted driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp. (2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012) .Light Source (LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS: 16105(2012). IS:16108(2012), IEC:62471.1.Input operating voltage :-105-295 V AC. 2:-Normal Voltage-220V AC.3.Driver type: constant current driver with short circuit protection(For tube light). 4.Control of distribution:-Full cut off. 5.Drive component :Industrial grade only .6.Efficiency of driver electronic: > 85% (For tube light).7.Colour temperature:5000- 6500K(For tube light). 8.Colour rendering index(CRI):>75(For tube light). 9.Ingress protection :IP-20. 10.Lumen output: >100 lumens/[email protected] drive current(For tube light). 11.Power factor:->0.90(For tube light). 12.Total hormonics distrotion(THD):-<20% (For tube light). 13. Lamp cover :Acrylic cover which does not result in loss of lumens. 14. Finishing:Power coated /Anodized. 15.Secondry optics:poly corbonate reflector/ poly carbonate lens. 16. Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum. 17.Mounting :Suitable for surface mounting/recessed mounting. 18. Certificate: Firm to submit LM80(In respect of LED used) & LM79 (In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for complience of BIS/IEC. 19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials praMtrs.s must remain unchanged during entire warranty period. 1x18/20 watt. Inspection by- Consignee. Inspection by-Consignee.
Supply, erection, testing and commissioning of Numbers One phase distribution board comprising of one no. 32/40 amps DP MCB with 40 A ELCB/RCCB as incoming and 4 nos. 10 amps SP MCB , 4 nos. 20 A SP MCB as outgoing complete with copper bus bars, neutral link and other accessories housed in CRCA sheet enclosure with double door type. Inspection by-Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, replacement, fixing, testing, connecting Numbers and commissioning of 72 Watt or above LED street lights fittings as per IS:10322. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and potted driver together with parts of distribute lights,to position and protect the light source,and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101 (2012) IS :16106(2012). Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS:16105(2012). IS:16108(2012), IEC:62471. Type LED:- High power LED,SMD(Surface Mounting device)/COB(Clip on board). 1.Input operating voltage :-105-295 V AC.2:- Normal Voltage-220V AC,3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours. 5.Depreciation:- 30% max.after 50000 burning hours.6.Control of distribution:-Full cut off. 7.Surge protection:4KV. 8.Drive component :Industrial grade only.9.Efficiency of driver electronic: > 85%.10.Beam angle:>=140 degree along with road and >=80 degree across the road.11.Colour temperature:5000-6500K. 12.Colour rendering index(CRI):>=75. 13.Ingress protection :IP-66.14.Lumen output: >120 lumens/watt.15.Power factor:->0.95. 16.Total harmonics distortion(THD):- <15%.17.Lamp cover :Toughened glass or UV stabilised poly carbonate. 18.Finishing:Power coated/Anodized. 19.Secondry optics:poly carbonate reflector/ poly carbonates lens. 20.Construction of housing: extruded aluminum/ CRCA/Pressure die cast aluminum. 21.Mounting :Suitable for existing pole/ Truss/ Lantern mounted. 22.Certificate:Firm to submit LM 80(In respect of LED used) & LM79 (In respect of luminare used) test certificate from National/ International accredited Laboratory and OEM certificate for compliance of BIS/IEC. 23.Warranty:Firm to submit warranty certificate for five year along with the supply. All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Material paraMtrs.s must remain unchanged during entire warranty period. Inspection by- Consignee. Inspection by- Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply and erection of 6 Mtr. Galvanized (as per Numbers BS EN ISO 1461) octagonal pole with base plate 220x220x12mm, top 70 mm and bottom 130 mm of 3 mm thick sheet suitable for maximum wind speed upto 160 Km/Hr. including foundation bolts and foundation with M 20 grade RCC and FE 415 grade reinforcement (450x450x800 mm deep ) (foundation should be as per design approved by pole manufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fixing of double arm hot dipped galvanized bracket suitable for street light fittings and supplying and drawing of 3x2.5 Sq.mm FRLS copper conductor single core cable from junction box with two Nos 6/10 AMP MCB to luminaire complete including termination with copper lugs as required. Inspection by- Consignee.
Supply, erection, testing and commissioning of Numbers single earth electrode of 50 mm. dia 4000mmlong GI pipe class B complete with earth boxwith CI cover hinged to CI frame includingconnection from earth electrode toMDB/SDB/poles/with 8 swg GI wire/strip as perattached drawing. Inspection by-Consignee. Inspection by-Consignee.
Supply and instalation of 1-phase 5KVA, Numbers 120/96Volt DC input UPS with Battery Bank of 12V, 10 Nos tubular battereies of Okaya or any superior approved make each of 150AH for Emergency Supply of Metring system and sub- station lightings .After completion of the works all materials to be deposited to the concern SSEs stores. Inspection by- Consignee. Inspection by- Consignee
Supply erection, testing & commissioning of Set basic Earthing Kit 1set as per RDSO spec. No RDSO/PE/SPEC /PS/0109(REV.0)-2008, Amendment '1' or latest specification. Inspection by- Consigne
Supply, fixing, testing and commissioning of 250 Numbers mm sweep fresh air fan complete. Inspection by- Consignee.
Supply, fixing, testing and commissioning of wall Numbers mounted/recessed LT Double door 4Way distribution board made up of steel sheet, phosphatised powder painted complete with neutral link, earth point, Din rail and prewired with following items to be fixed in distribution board and site requirement. Inspection by- Consignee. Inspection by-Consignee.
Supply, fixing, testing and commissioning of wall Numbers mounted/recessed LT Double door 6Way distribution board made up of steel sheet, phosphatised powder painted complete with neutral link, earth point, Din rail and prewired with following items to be fixed in distribution board and site requirement. Inspection by- Consignee. Inspection by-Consignee.
Supply, fixing, testing and commissioning of DP Numbers RCBO's 10 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2,IEC-61009-1 or latest. Inspection by-Consignee.
Supply, fixing, testing and commissioning of DP Numbers RCBO's 16 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2,IEC-61009-1 or latest. Inspection by-Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
04 Pole On load Manual side handle operated Numbers Change Over Switch, Size frame-2 with extended handle rating 250 Amp 415 volt 50 HZ Conforming to IS:/IEC 60947-3, including terminal shrouds source separator and phase barriers. Inspection by-Consignee.
Supply of heavy duty aluminium stool type Numbers folding ladder having "C" shapes section of size 16"x12" on top suitable for height upto 12 feet complete similar to Sumer make design no. AL- 201/8818 (heavy duty) or equivalent. Inspection by-Consignee.
Supply, fixing, testing and commissioning of wall Numbers mounted LT distribution board made up of steel sheet, phosphatised powder painted complete with neutral link,earth point, Din rail and prewired confirming to IS:13032 & 8623:1991 withfollowing items to be fixed in distribution board, confirming to IS:8828 :1996 orlatest, IE rules and site requirement. 4P, MCCB 125 Amps. 10 kA 'C' series= 01 No.(Incoming) DP RCCB (25, 40 Amps., three nos. each) 10 kA 'C' series = 06 Nos.(Outgoing). Inspection by-Consignee
Supply, fixing, testing and commissioning of wall Numbers mounted LT distribution board made up of steel sheet, phosphatised powder painted complete with neutral link,earth point, Din rail and prewired confirming to IS:13032 & 8623:1991 with following items to be fixed in distribution board, confirming to IS:8828 :1996 orlatest, IE rules and site requirement. 4P, MCCB 125 Amps. 10 kA 'C' series= 01 No.(Incoming) DP RCCB (40 & 63 Amps., two nos. each) 10 kA 'C' series = 04 Nos.(Outgoing). Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning of 1 phase, 220 Volt, 03HP, 2.5 lps discharge, outer dia 4 inches, SS body max 15 stage submersible pump set of two star rated as per relevant technical specification. Inspection by-Consignee
Supply of 1 phase, 220 Volt, 03HP, 2.5 lps Numbers discharge, outer dia 4 inches, SS body max 15 stage submersible pump set of two star rated as per relevant technical specification. Inspection by-Consignee
Supply, erection, connecting, testing and Metre commissioning of multi stranded single phase 220 Volts, 3 X 2.5 Sq mm PVC insulated flat copper conductor submersible cable confirming to IS: 694:2010.Inspection by-Consignee
Supply, commissioning of single phase 220 V, AC, 50 C/S, 5 KW DOL, in 16 SWG steel sheet enclosure light gray spray painted, panel wiring of power section with 1x2.5 Sqmm multi stranded PVC insulated copper conductor 1.1 kV grade, comprising of - 1 No Toggle switch 15 Amps, 01 No Ammeter (0-200A), 01 No voltmeter (0- 600V), 01 set CT coil, 02 Nos LED Indication lamps, 03 Nos cut out 6A for control, 03 Nos Toggle switch 6A for control, 2 set Green/Red push button for ON/OFF, 01 No KWH meter.Inspection by-Consignee
Supply, erection, connecting, testing and Job commissioning of required of size 2 Inch (50 mm) dia, CPVC, class1(SDR-11) and IS:15778: Latest Riser pipe length 3 Meter each.Inspection by-Consignee PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, erection, connecting, testing and Metre commissioning of PVC coated stainless steel Multi stranded & tested wire rope of size 4 mm.Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning of column Pipe female adapter brass thread(FABT) of size 2 Inch (50 mm) dia.Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning of coupler of size 2 Inch (50 mm) dia.Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning reducer coupler of size 2"x1'' Inch(50x25 mm) dia.Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning of power coated metal clamp of size 2 Inch(50 mm) dia.Inspection by-Consignee
Supply, erection, connecting, testing and Numbers commissioning of elbow 90 degre of size 2 Inch(50 mm) dia. Inspection by-Consignee.
SITC of 10 kVA single phase air cooled servo Numbers stabilizer, IP55 suitable for phase voltage range 120 to 270 Volts.Inspection by-RITES
Supply, fixing, Testing and Commissioning of Numbers Vertical type submersible borewell pump set of capacity 20HP, 396LPM, 120 mtr head, 3Ph, 415 volt, 50 Hz, AC supply with SS/AI Bronze impeller, delivery size 80mm complete confirming to IS-8034-2002 (or latest) with all accessories and site requirement. Inspection by- Consignee.
Supply & testing of Vertical type submersible Numbers borewell pump set of capacity 20HP, 396LPM, 120 mtr head, 3Ph, 415 volt, 50 Hz, AC supply with SS/AI Bronze impeller, delivery size 80mm complete confirming to IS-8034-2002 (or latest) with all accessories and site requirement. (as standby). Inspection by- Consignee.
Supply, fixing and commissioning of 3 core flat Metre PVC insulation and sheathed with multi strand flexible copper conductor 1100 volts suitable for submersible pump (for maximum conductor temperature 70 deg. C to 85 deg. C approx, water proof, confirming to IS-694 latest as per IS/IE rule sand site requirement) 3Cx6 sqmm. Inspection by- Consignee.
Supply, fixing, testing and Commossioning of MS Numbers flange for joining the 3"" GI pipes having 3"" inner dia and outer dia suitable for passing smoothly in 8""casing of bore well as well as including 4 sqmm flat submersible double cable inparallel. Inspection by- Consignee.
Provision of fixing of flange in both side of 3" GI Numbers pipes complete. Inspection by- Consignee.
"Supply, fixing, testing and Commossioning of B Metre class GI pipe of the following size, 80 mm Inspection by- Consignee."
Supply, fixing, testing and Commossioning of 10 Numbers HP fully automatic star-delta starter for submersible pump with overload current range 08-14 amp, with single phase protection, Dry run, over voltage andunder voltage, phase reversal with all accessories and site requirement. Inspection by- Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Supply, fixing, testing and Commossioning of 15 Numbers HP fully automatic star-delta starter for submersible pump with overload current range 13-22 amp, with single phase protection, Dry run, over voltage and under voltage, phase reversal with all accessories and site requirement. Inspection by- Consignee.
Supply, fixing, testing and Commossioning of 20 Numbers HP fully automatic star-delta starter for submersible pump with overload current range 20-32 amp, with single phase protection, Dry run, over voltage andunder voltage, phase reversal with allaccessories and site requirement. Inspection by- Consignee.
Supply, erection, testing & commissioning of 12 Metre mm Multi stranded galvanized insulated & tested wire rope. Inspection by- Consignee.
Water pressure gauge 40 MM complete with Numbers fitting. Inspection by- Consignee.
Supply, fixing, testing and Commossioning of CI Numbers gate valve as per site requirement of the following size, 80 mm. Inspection by- Consignee.
"Supply, fixing, testing and Commossioning of Numbers Elbow of following size, 80 mm Inspection by- Consignee."
Supply, fixing, testing and Commossioning of MS Numbers Flange of size 3" suitable for 80 mm NRV & Gateway complete.Inspection by- Consignee.
Wiring for light/fan/exhaust fan/call bell points Numbers with 1.5 sqmm (22/.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI mark, MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor approved make) copper earth wire along with the pipe duly clamped as required and as per relevant technical specification No.Sr.DEE/G/ALD/IE/94/ 104/Rev and additional specification .a) Medium Point.
Wiring for 3/5 pin, 5 Amp. Plug point with 1.5 Numbers sqmm (22/.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable including providing and fixing 3/5 pin 5 Amps. Socket out let with switch on same board and earthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor approved make) copper earth wire etc. as required and as per relevant technical specification.
Wiring for 3/5 pin 5/15 amps plug points with 2.5 Numbers sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including providing and fixing 3/5 pin 5/15 Amps socket outlets and 5/15 Amps piano type switch and earthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor approved make) Copper earth wire along with pipe duly clamped as required and as per relevant technical specification.(5pin 15Amp). PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Wiring for submain with 4 sqmm (56/0.3 mm) Metre PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor approved make) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification.(a) 2 x 4 sq mm Inspection by- Consignee
Supply, commissioning of 300 mm sweep Exhaust Fan suitable for 230 volts, 50 Hz AC supply, 1440 RPM heavy duty with wiring and flexible PVC pipe as required. Inspection by- Consignee.
Design, andcommissioning of front operateddouble door type weather proof feederpillar feeder (MCCB - Incoming & MCCB- Outgoing) comprising with thefollowing MCCB's fixed in it conformingto IS- 60947:2 with digital measuringinstrument & bus-bar arrangement asper IS, IE rules and site requirement.4P MCCB 250 Amps 36 kA withadjustable thermal & fixed magneticrelease = 01 No. (Incoming), 4P MCCB125Amps 36 kA with adjustablethermal & fixed magnetic release = 02No. (Outgoing) 4P MCCB 63 Amps 36kA with adjustable thermal & fixedmagnetic release = 04 No. (outgoing)Inspection by-RITES
Supply, erection, testing and commissioning of Numbers approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification......DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's & 4-No SP MCB's of 6 Amps of approved make. Inspection by- Consignee.
Supply, erection, testing and commissioning of Numbers approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification......DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's & 4-No SP MCB's of 6 Amps of approved make. Inspection by- Consignee.
"Supply, fixing, testing and Commossioning of Numbers MCCB's with enclosure of the folowing sizes, 100 amp. Inspection by- Consignee. Total 6202972.30
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2026_03_13GCCAdvanceCorrectionSlipNo_11_1.pdf
ATTACHMENT
Tenderdocument_1.pdf
ATTACHMENT
GCCACS2022CORRECTION.pdf
ATTACHMENT
Likelysourceofsupply.pdf
ATTACHMENT
ACS_7to10.pdf
ATTACHMENT
GCC correction
ATTACHMENT
GCC_April-2022_2022__27_04_227.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
AnnxVIB.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_21.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-31.pdf
ATTACHMENT
2023_08_07RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4_1.pdf
ATTACHMENT
2023_10_20RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-5_1.pdf
ATTACHMENT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-6_1.pdf
ATTACHMENT
QTYbifurcation.pdf
ATTACHMENT
Download all tender documents and submit your bid