Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.4 L+₹2.9 L (9.53%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹35.4 L+₹4.9 L (15.9%)Rejected-AOC | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | L4₹38.9 L+₹8.3 L (27.3%)Rejected-AOC | L4 | Rejected-AOC Rejected being not L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
29 Mar 2022, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
SPECIAL REPAIR TO BUILDING NO. 5 OF 5 NO. CHARGE INCLUDING PILLARS FLOORING AND ELECTRONIC PARTS AT RTS AND DEPOT SAHARANPUR
2022_MES_511379_1
8392/142/E8
Open Tender
Civil Works
Item Rate
180 days
Saharanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹92,000
Yes
1 Jun 2022
2 Mar 2022
31 Mar 2022
2 Mar 2022
29 Mar 2022
16 Mar 2022
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m deep for foundations etc or for shafts, wells, cesspits, manholes, pier holes, laying of pipe line, cable, electric poles/stays etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone agregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) in foundation, footing, plinth beam, bases of columns and similar works complete all as specified and directed.
Use and waste formwork to sides of concrete foundation, footing, bases of columns, sides and soffits (if any) of plinth beams and similar work (vertical or to batter) for rough finished flat concrete surfaces complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in Columns, pillars, piers and similar works complete all as specified and directed.
Use and waste formwork to sides of posts, struts, piers, columns and similar work (vertical or to batter) for rough finished flat concrete surfaces complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in floor/roof beams, cantilevers, bressummers, lintels over 1.5m span and similar work complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, cantilevers, bressummers, lintels over 1.5m span and similar work for rough finished flat concrete surfaces complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with soft lose soil obtained from excavation complete all as specified and directed.
Removing excavated surplus soil at a distance n.ex5 50 m and deposting where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed .
M&L for brick work in cement mortar (1:4) using old size sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks in half brick thick walls in cement mortar (1:4), straight or curved on plan exceeding 6 meter mean radius complete all as specified and as directed.
Taking down old cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including preparation of newly plastered surfaces of walls and applying three coats white wash complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick flooring laid with dry bricks flat or on edge complete all as specified and directed.
M&L for brick flooring with old size sub class 'A' bricks, laid dry on edge over and including 25mm thick layer of sand and filling the joints with dry sand complete all as specified and directed.
All as per srl item No. 20.00 above but except bricks. Note:- Old serviceable bricks obtained from dismantling to be re-used
M&L for brick flooring with old size sub class 'A' bricks, laid dry on edge over and including 25mm thick layer of sand and pointed in cement mortar (1:3) complete all as specified and directed.
Taking down asbestos (corrugated, semi-corrugated etc) sheets in roof covering including ridge of any description complete all as specified and directed.
S&F 6 mm thick asbestos cement corrugated sheets in roofs, wall cladings etc, fixed with J-type or L-type or cranked hook bolts complete all as specified and directed by Engineer-in-Charge.
Fixing only 6 mm thick asbestos cement corrugated or semi corrugated sheets in roofs , wall etc fixed with J-type or L-type or cranked hook bolts complete all as specified and directed by Engineer-in-Charge. Note:- Serviceable sheets retrieved from dismantling to be re-used.
S&F 0.63 mm plain galvanized mild steel sheeting in ridges, hips, valley gutters, drips and straight flashing (Length and Girths as fixed) with grade of zinc coating 275 complete all as specified and directed by Engineer-in-Charge..
S&F FRP based with stainless steel MOC fins and internal fittings Air ventilator, Throat Size 21" to 24", Max exhaust capacity 2700 CFM double jet sealed ball bearings all as per manufacturer's instructions complete all as per directions of Engineer-in-Charge. Make :- Dura Plast (Rhino tuff) or equivalent and approved make
Dismantling of timber scantlings of any description under 40 Sqcm in purlins etc complete all as specified and directed by Engineer-in-Charge.
S&F rolled mild steel work as in tubular beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates using ERW or induction butt welded tubes conforming to IS:1161- 1979 grade St.-240 complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down old unserviceable point wiring of any description (light, fan, socket or power ponts) including fittings and fixtures such as switches, sockets, ceiling rose, pendant, fan regulators etc and M&L for new point wiring with PVC insulated PVC unsheathed electric (FRLS) cable of size 1.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor, drawn throgh and including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting chases in wall and making good disturbed surfaces in cement mortar (1:3) to match the existing surfaces (PVC conduit shall be used on ceiling surface for fan point only) with 1.5 Sqmm green PVC insulated unsheathed electric (FRLS) cable having multistranded copper conductor as earth wire connected to earth dolly by providing lugs including sunk pressed steel terminal boxes made of 1.6 mm thick GI sheet duly painted with two coats of black bituminous paint over a coat of red oxide primer on inner and outer surfaces with and including 2.8mm thick plastic laminated bakelite sheet cover of hylam board including cutting holes for switches, sockets, regulators etc as per site requirement and fixing with machine made brass screws, washers etc complete all as specified for the following:-
One light point controlled by one, one way 5/6 Amps switch
One fan point controlled by one, one way 5/6 Amps switch
One socket outlet point for 3/5 pin 5 Amps socket on the same board with other switches.
One socket outlet point for 3/5 pin 5 Amps socket onindependent board.
All as per Srl item No. 31.00 here-in-before but one power point with 1.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor for 3/5 pin 15 Amps socket including 2.5 Sqmm green PVC insulated unsheathed electric (FRLS) cable having multistranded copper conductor as earth wire complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/6 Amps flush type complete all as specified.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified.
S&F electronic fan regulator 230 Volts , stepped type (5 steps) socket type, hum free 100/300 Watt complete all as specified and directed.
S&F ceiling rose in polycarbonate with 3 brass terminals, 6 Amps, 230 Volts, AC (ISI marked), fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet complete all as specified and directed.
S&F lamp holder PVC / polycarbonate type with back plate, fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet and 9 Watt LED bulb PAG series B-22 base complete all as specified and directed.
Taking down old unserviceable sub main wiring of any description and S&F new sub main wiring with two runs of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS) LT cable having multi stranded copper conductor, drawn through and including PVC non metallic conduit of 20mm / appropriate dia with all accessories and one run of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS) LT cable having multi stranded copper conductor complete all as specified and directed by Engineer-in-Charge. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
S&F in replacement, LED tube light fitting 1x16/20 Watt surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver complete with all accessories internally prewired and connecting up with three core single wire complete all as specified and directed.
S&F in replacement, building security light with new generation energy saving and environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source with exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35 watt capacity LED including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete all as specified and directed.
S&F in replacement, Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way conforming to IS : 13032-1991DB, 415 Volts IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, flush to wall complete all as specified and directed.
S&F in replacement, Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way conforming to IS : 13032-1991DB, 415 Volts IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, flush to wall complete all as specified and directed.
S&F in replacement, MCB single pole, 6 to 32 Amps 240 Volt 'B' curve 10 kA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and directed.
S&F in replacement, MCB double pole, 40 Amps 240 Volt 'B' curve 10 kA, IP 20, 50 Hz, transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and directed.
Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions) with cover made of RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm C/C both ways and angle iron 40X40X5mm frame etc duly painted with two coats of synthetic enamel paint over a coat of red oxided primer on exposed surfaces complete all as specified and directed by Engineer-in-Charge. Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point.
Supply & laying in replacement and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 Sqmm 2 core, laid in trenches or through pipe complete all as specified and directed.
Dismantling of unserviceable house service bracket and service cable of any type and description complete all as specified and directed.
S&F in replacement, 40mm dia bore GI tubing, medium grade with all fittings for cable protection including GI clamps, nut & bolts and washers or burried in ground complete all as specified and directed.
Supply and laying clean dry river sand for cushioning in layers, 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified and directed. Note:- Thickness of sand cushioning shall be measured as 18 cm after punning for payment)
Supply and laying old size sub class ‘B’ bricks for cable protection, laid dry flat adjacent to each other across the length of cable complete all as specified and directed.
RAM PRAKASH AND ASSOCIATES
Baggay construction Company
PANWAR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .