Ex Engineer std pulwama
office of Ex Engineer STd Pulwama
Stage Contract for Maintenance of 33/11 KV Receiving Stations Falling Under the Jurisdiction of Sub Transmission Division Pulwama for the Year 2022-2023 or till next rate contract
2022_PDD_196114_1
nit 35 of std pul
Open Tender
Electrical Works
Item Rate
15 days
STD Pulwama
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Ex Engineer std pulwama
₹30,000
25 Nov 2022
15 Nov 2022
23 Nov 2022
15 Nov 2022
22 Nov 2022
15 Nov 2022
Amount
Dismantalling of
11KV VCB Panel complete
33KV C&R Panel complete
33KV VCB / MOCB complete
Installation,testing and commissioning of Switchgear System complete (material to be provided by the department)
11KV VCB Panel complete
33KV C&R Panel complete
33KV VCB complete
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out/low size 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Allind Panels
Supply,installation,testing,commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out/low size 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable 11KV VCB panels of make Easun Reyrol / Vijay
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panels)
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV VCB panels)
Installation,testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11KV VCB panel)
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel
Alsthom make
Easun Reyroll Make
Vijay Make
Sudhir Make
Electric Field
Crompton Greeves
Allind
ABB Make
Providing and fixing of female contact (complete assembly, set of 6 pieces) for 11KV VCB by way of Replacement of Damaged/Burnt Out female contact set of same composition,type,make and class already installed in 11KV VCB panel
Alsthom make
Easun Reyroll Make
Vijay Make
Sudhir Make
Electric Field
Crompton Greeves
Allind
ABB Make
Providing and fixing of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make as already installed in 11KV VCB panel (1250amps)
Fixing of fresh 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department)
Supply,installation,testing and commissioning of Numerical/Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts
Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department)
Rectification,Re-Alignment,setting right the electrical section of 11KV Breakers (11KV VCB panel)
Rectification,Re-Alignment,setting right the mechnical section of 11KV Breakers (11KV VCB Panel)
Rectification,Re-Alignment,setting right the electrical section of 33KV C&R panel
Rectification,re-alignment,setting right the mechnical section of 33KV VCB
Rectification,re-alignment,setting right the mechnical section of 33KV MOCB
Replacement of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete.
Supply,installation,testing,commissioning of Tripping/closing coils suitable for 11KV VCB Panels like Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T etc
Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps)
Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type)
Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type)
Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type)
Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type)
Supply,installation,testing and commissioning of 33KV C.T(3-core) confirming to IEC:185 and IS:2705 (part-1 to 4) standards of ratio 300-150/5-5-5A/ 250-125/5-5-5A) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type
Supply, installation,testing and commissioning of 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3) confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type
Providing and fixing of 33KV isolator 800 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards
With earthing blade
Without earthing blade
Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade)
Providing, Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps.
Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps. (material to be supplied by the department)
Providing,Installation,Testing and commissioning of 11KV G.O Set 200 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one
Installation,Testing and commissioning of 11KV G.O Set 200 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V) (material to be supplied by the department)
Providing, fixing, installation, testing and commissioning of 11KV Isolators,800amps. conforming to IS 9921/IEC-129 standards
With earthing blade
Without earthing blade
Installation,Testing and commissioning of 11KV Isolators,800amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade ) (material to be supplied by the department)
Providing, Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damaged one heavy duty 600amps.
Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damaged one heavy duty 600amps. (material to be supplied by the department)
Providing and fixing of 33KV Drop out set with porcelaine insulator by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department)
Providing, Installation,Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department)
Oil Toping in 33/11 KV Power Transfromers and 33KV MOCB's (Transformer oil to be supplied by the department)
Providing,installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers
Providing,installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers
Providing and fixing of interrupting chambers (Housing Assembly) suitable for 11KV VCB of different make by way of replacement of damaged one
Crompton Greeves
Vijai
Alasthom
Easun Rey roll
Electric Field
Providing and fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different make by way of replacement of damaged one
Providing and fixing of spouts bushing suitable for 11KV VCB (Allind-Make) panel of different make by way of replacement of damaged one
Providing and fixing of spouts bushing suitable for 11KV VCB (Alasthom/Easun Reyroll/Vijay/Sudhir/Electric field/Crompton greeves/ ABB-Make) panel of different make by way of replacement of damaged one
Providing and fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one
33KV side
11KV side
Supply ,installation,testing and commissioning of 30V,200 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make
Supply,installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Laying,Testing,commissioning of 11KV (E) grade armoured ,3-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (material to be supplied by the department)
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Laying,Testing,commissioning of 11KV (E) grade armoured ,1-core,Xlpe Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (material to be supplied by the department)
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Supply,laying,Testing,commissioning of 2.5 sqmm Control cable armored , copper conductor sheathed PVC insulated multi colour voltage grade 1.1 KV conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 2.5 sqmm Control cable armored , copper conductor sheathed PVC insulated multi colour voltage grade 1.1 KV conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Installation,Testing and commissioning of 11KV cable termination kits (indoor Type) (material to be provided by the department)
630mm^²,3-core
400mm^²,3-core
300mm^²,3-core
240mm^²,3-core
185mm^²,3-core
150mm^²,3-core
120mm^²,3-core
Supply,installation,testing,commissioning of 11KV ,1 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Installation,testing,commissioning of 11KV ,1 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Installation,Testing and commissioning of 11KV cable termination kits (indoor Type) (material to be provided by the department)
630mm^²,1-core
400mm^²,1-core
300mm^²,1-core
240mm^²,1-core
185mm^²,1-core
150mm^²,1-core
120mm^²,1-core
Dragging(upto Avg. lead 50 mtrs.) and rotation (if required) of 33/11KV Power Transformer (Complete Job)
Loading of Power Transformer to the sub station bed / plateform (Complete Job)
Unloading of Power Transformer from the sub station bed / plateform (Complete Job)
Carriage of Power Transformer upto 20KM from source to destinantion
Carriage of Power Transformer (10/6.3/5/4/3.15 MVA) beyond 20KM
Unloading of material which are to be handled with care like 33KV CT / 33KV PT etc including manual carriage from dumping site upto proper stacking
Loading of of material which are to be handled with care like 33KV CT / 33KV PT etc including manual carriage stacking site upto loading
Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc
Upto first 100mtr lead
For every additional 50mtr or part there off
Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking
Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage stacking site upto loading
Supply ,installation,testing and commissioning of copper Bus Bar (2ftx10mm)
Repairing /Replacement of 11KV VCB's
Tripping Mechanism
Modification of Mechanism
Re-setting links
Replacement of operating shaft
Shower contact
Isolating Sockets
Closing mechanism (replacement)
High Tension spring
Tripping shaft
Rollers
Latch assembly
Overhauling of 11KV VCB
Deco spray painitng
Installation,Testing and commissioning of Power Transformer of capcity (3.15/4 MVA/5MVA/6.3 MVA/10MVA) complete job including all neceesary testing at site
Dismanteling of Power Transformer of capcity (3.15MVA /4 MVA /5MVA /6.3MVA /10MVA) complete job
Providing and fixing of yard lights of 50watt along with 10sqmm 2 core PVC cable of 50mtrs and one MCB 6/16Amp.
Supply and Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface etc complete, on steel work including Channel iron, Angle iron, chainlink fencing and ST poles.
Kashmir Engineering Aids
BHAT CONSTRUCTIONS
LIGHT ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .