GEMC-511687714307480
Awarded to DIGITAL MARKETING SYSTEMS PVT. LTD.
₹3.0 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Fluke 376 True-rms AC/DC Clamp Meter with iFlex | FLUKE 376 | - | 9 NOS | ₹33,340 | 300,060 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.0 LQualified Make: FLUKE
Model: FLUKE 376 122 KANCHAN BAGH KANCHAN BAGH KANCHAN BAGH INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: FLUKE
Model: FLUKE 376 | L1 | Qualified | |
| 2 | L2₹3.0 L+₹1,350 (0.45%)Qualified Make: FLUKE
Model: FLuke 376 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: FLuke 376 | L2 | Qualified | |
| 3 | L3₹3.4 L+₹36,000 (12.0%)Qualified Make: FLUKE
Model: FLUKE 376 AC/ DC Clamp Meter with Iflex COLLECTOR SIVAKUMAR STREET COIMBATORE COIMBATORE TAMIL NADU 641038 | COIMBATORE | TAMIL NADU | 641038 | Make: FLUKE
Model: FLUKE 376 AC/ DC Clamp Meter with Iflex | L3 | Qualified | |
| 4 | L4₹3.4 L+₹37,431 (12.5%)Qualified Make: FLUKE
Model: Fluke 376 00 FRONT OF DR S P CHAUDHARY MALVIYA ROAD GANDHI NAGAR BASTI BASTI UTTAR PRADESH 272001 | BASTI | UTTAR PRADESH | 272001 | Make: FLUKE
Model: Fluke 376 | L4 | Qualified | |
| 5 | L5₹3.4 L+₹43,740 (14.6%)Qualified Make: FLUKE
Model: FLUKE 376 AC/ DC Clamp Meter with Iflex PLOT NO 1 98 PLOT N0 1 98 SECTOR 1 VAISHALI GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: FLUKE
Model: FLUKE 376 AC/ DC Clamp Meter with Iflex | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 Sept 2018, 10:00 amClosed
true rms clamp meter True Rms Clamp Meter ( 9 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL FEATURES Type Hand Held Hand Held Display 3.5 digit Backlit LCD 3 digit Backlit LCD
3.5 digit Backlit LCD
4 digit Backlit LCD
4.5 digit Backlit LCD Measurement Type True RMS True RMS count 6000 3000
4000
6000
10000 MEASUREMENT FEATURES Resistance Measurement Range 1000 4
10
100
1000 Resistance Measurement Accuracy (+/-) 1 0.5
1
1.5
2 Frequency Measurement Range 500 0.5
500 Frequency Measurement Accuracy (+/-) 0.5 0.5
0.3
0.1 AC Current 1000 10
1000 1/4 Measurement Range AC Current Measurement Accuracy (+/-) 1 1
2
2.5 AC Voltage Measurement Range 1000 400
600
750
1000 AC Voltage Measurement Accuracy (+/-) 1 1.5
2 DC Current Measurement Range 1000 100
1000 DC Current Measurement Accuracy (+/-) 1 1.5
1 DC Voltage Measurement Range 1000 0.4
4
40
400
1000 DC Voltage Measurement Accuracy (+/-) 1 1
2 Other features
if applicable iFlex® Flexible Current Probe expands the measurement range to 2500 A AC CAT IV 600 V
CAT III 1000 V True RMS AC voltage and current for accurate measurements on non- linear signals Min
max
average and Inrush recording to capture variations automatically * GENERIC Jaw Size (Dia in Closed State) 34 * Dimensions (H x W x L) (mm x mm x mm) 269 mm x 277 mm x 160 mm * Weight 388 * POWER REQUIREMENTS Power Requirements Battery Operated * Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell AA * Number of non- rechargeable the battery/cell 2 * 2/4 Voltage of rechargeable Battery milliamphere hour 0 * Suitable charger/adaptor provided NA * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 55 * Operating Humidity (RH) 90 * SAFETY Safety Certification UL
CE
CSA
TUV * Safety Rating CAT III 600 V of IEC 61010 -2-D31 CAT III 600 V of IEC 61010 -2-D31 ACCESSORIES Details of the Standard Accessories Supplied with the Equipment Coated instruction card. Safety information sheet. Soft carrying case. TL75 test leads. Five AA Alkaline batteries. IFLEX UPTO 2500 AMPS CURRENT PROBE. * SERVICE Warranty 3 3.0 TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * 3/4 Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 J. Jeeva 583119
NMDC LIMITED DIOM
DONIMALAI PO BELLARY DIST KARNATAKA STATE 9 30
599978
GEM/2018/B/85219
GeM Contract
true rms clamp meter
GeM Contract
30 days
Karnataka; Ballari
PRODUCT
Awarded to DIGITAL MARKETING SYSTEMS PVT. LTD.
₹3.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Fluke 376 True-rms AC/DC Clamp Meter with iFlex | FLUKE 376 | - | 9 NOS | ₹33,340 | 300,060 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| true rms clamp meter True Rms Clamp Meter ( 9 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL FEATURES Type Hand Held Hand Held Display 3.5 digit Backlit LCD 3 digit Backlit LCD | - | - | - |
| 3.5 digit Backlit LCD | - | - | - |
| 4 digit Backlit LCD | - | - | - |
| 4.5 digit Backlit LCD Measurement Type True RMS True RMS count 6000 3000 | - | - | - |
| 4000 | - | - | - |
| 6000 | - | - | - |
| 10000 MEASUREMENT FEATURES Resistance Measurement Range 1000 4 | - | - | - |
| 10 | - | - | - |
| 100 | - | - | - |
| 1000 Resistance Measurement Accuracy (+/-) 1 0.5 | - | - | - |
| 1 | - | - | - |
| 1.5 | - | - | - |
| 2 Frequency Measurement Range 500 0.5 | - | - | - |
| 500 Frequency Measurement Accuracy (+/-) 0.5 0.5 | - | - | - |
| 0.3 | - | - | - |
| 0.1 AC Current 1000 10 | - | - | - |
| 1000 1/4 Measurement Range AC Current Measurement Accuracy (+/-) 1 1 | - | - | - |
| 2 | - | - | - |
| 2.5 AC Voltage Measurement Range 1000 400 | - | - | - |
| 600 | - | - | - |
| 750 | - | - | - |
| 1000 AC Voltage Measurement Accuracy (+/-) 1 1.5 | - | - | - |
| 2 DC Current Measurement Range 1000 100 | - | - | - |
| 1000 DC Current Measurement Accuracy (+/-) 1 1.5 | - | - | - |
| 1 DC Voltage Measurement Range 1000 0.4 | - | - | - |
| 4 | - | - | - |
| 40 | - | - | - |
| 400 | - | - | - |
| 1000 DC Voltage Measurement Accuracy (+/-) 1 1 | - | - | - |
| 2 Other features | - | - | - |
| if applicable iFlex® Flexible Current Probe expands the measurement range to 2500 A AC CAT IV 600 V | - | - | - |
| CAT III 1000 V True RMS AC voltage and current for accurate measurements on non- linear signals Min | - | - | - |
| max | - | - | - |
| average and Inrush recording to capture variations automatically * GENERIC Jaw Size (Dia in Closed State) 34 * Dimensions (H x W x L) (mm x mm x mm) 269 mm x 277 mm x 160 mm * Weight 388 * POWER REQUIREMENTS Power Requirements Battery Operated * Type of Battery Non- Rechargeable (Alkaline) * if rechargeable | - | - | - |
| then chemistry of the battery NA * if Non-rechargeable | - | - | - |
| then size of the battery cell AA * Number of non- rechargeable the battery/cell 2 * 2/4 Voltage of rechargeable Battery milliamphere hour 0 * Suitable charger/adaptor provided NA * OPERATING CONDITION Minimum Operating Temperature -10 * Maximum Operating Temperature 55 * Operating Humidity (RH) 90 * SAFETY Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| TUV * Safety Rating CAT III 600 V of IEC 61010 -2-D31 CAT III 600 V of IEC 61010 -2-D31 ACCESSORIES Details of the Standard Accessories Supplied with the Equipment Coated instruction card. Safety information sheet. Soft carrying case. TL75 test leads. Five AA Alkaline batteries. IFLEX UPTO 2500 AMPS CURRENT PROBE. * SERVICE Warranty 3 3.0 TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * 3/4 Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 J. Jeeva 583119 | - | - | - |
| NMDC LIMITED DIOM | - | - | - |
| DONIMALAI PO BELLARY DIST KARNATAKA STATE 9 30 | - | - | - |
Exempted
24 Sept 2018
12 Sept 2018
contract_GEMC-511687714307480.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_599978.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .