Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.0 L+₹51,790 (5.44%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹10.6 L+₹1.0 L (10.9%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹11.3 L+₹1.8 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
16 Apr 2021, 6:00 pmClosed
VIJAY NEHRA
GE SATWARI
REPAIR/MAINT OF LT PANELS AND ALLIED WORKS UNDER AGE E/M (MH) OF GE SATWARI
2021_MES_431454_1
GEJM-07/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE SATWARI
₹20,000
Yes
17 Jun 2021
19 Mar 2021
19 Apr 2021
19 Mar 2021
16 Apr 2021
2 Apr 2021
Amount
Dismantling PCC all as directed and making good surface
Dismantling of all unserviceable components of the APFC panel, applying two coats of powder coated painting by spray machine complete inner and outer side of APFC panel complete all as spefified and directed by Engg-in-Charge.
Disconnecting all electric connections, taking down, lifting and transportation of unserviceable APFC panels of any capacity and make to workshop for repair. After repair lifting, transportation to site and making all electric connections all as specified and directed by Engg-in-Charge.
M&L for shifting of LT panel/ APFC panel incl necessary PCC foundation wk and necessary electric connection all as specified and directed.
S&F standard duty box capacitor with inbult MCB and LED indication of rating 25 KVAR with necessary electrical connection all as specified and directed.
Digital multi functional meter which showing PF, Volts, Amps etc complete.
Phase indicating lamps each backed up with suitable MCB including necessary cable connection.
01 KVAR APP based Box Series: LTBCP capacitor bank.
02 KVAR APP based Box Series: LTBCP capacitor bank.
03 KVAR APP based Box Series: LTBCP capacitor bank.
05 KVAR APP based Box Series: LTBCP capacitor bank.
10 KVAR APP based Box Series: LTBCP capacitor bank.
15 KVAR APP based Box Series: LTBCP capacitor bank.
MCCB 3 pole 160 Amp, 36 KA Adjustable type 415 V.
MCCB 3 pole 250 Amp, 36 KA Adjustable type 415 V .
MCCB 3 pole 350 Amp, 36 KA Adjustable type 415 V.
MCCB 4 pole 250 Amp, 36 KA Adjustable type 415 V .
MCCB 4 pole 160 Amp, 36 KA Adjustable type 415 V .
MCCB 4 pole 250 Amp, 36 KA Adjustable type 415 V .
MCCB 4 pole 350 Amp, 36 KA Adjustable type 415 V .
Material and labour for double compression brass cable gland suitable for LT cable of size 25 to 95 sqmm 3.5 core
Material and labour for double compression brass cable gland suitable for LT cable of size 120 to 300 sqmm 3.5 core
M&L for replacement of MS channel, clamps, flats fabricated from structural steel including nuts, bolts, washers, welding, bending cold or hot & drilling holes for bolts in any shape or size all as specified and directed.
Repairs to door shutters of out door/Indoor LT switch board panel,MCCB,s covers,Bus bar chamber covers etc fabricated with MS sheet 3.15mm thick complete including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed by the Engineer-in-Charge.
M&L for Painting of Bus bar chamber of size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete including angle iron frame 50x50x6 mm in all respect all as specified and directed.
M&L for Bus bar chamber of size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect all as specified and directed.
Supplying, installation, commissioning and testing of LT switch gear control panel board 440 volt AC 3 phase 4 wire for out door installation "KIOSK TYPE" fabricated out of steel sections i.e CRCA sheet 3.15 mm thick , angle / channel and flat iron sections of suitable size with opening on front, and back door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard, with phosphatised powder coating painting externally and internally to protect against corrosion: The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, complete duly incorporated with following accessories: -
Supplying, installation, commissioning and testing of LT switch gear control panel board 440 volt AC 3 phase 4 wire for Indoor type installation "KIOSK TYPE" fabricated out of steel sections i.e CRCA sheet 3.15 mm thick , angle / channel and flat iron sections of suitable size with opening on front, and back door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard, with phosphatised powder coating painting externally and internally to protect against corrosion: The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, complete duly incorporated with following accessories: - (a) Bus bar chamber with electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators 4 strip of suitable length for current rating 400 amps
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth lead iron wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, GI light grade protection pipe 15mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 5 of SSR-1991 pt-I and testing complete including earth work in any type of soil PCC 1:2:4 as in earthing pit CI pit cover 5.5mm thick common salt charcoal all as specified.
Chemical earthing with Copper earth plate 900 X 600 X 5 mm & copper srip 32 X 6 mm
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar of size 50 cm X 50 cm X 20 cm factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect all as specified and directed.
Supplying, installation, commissioning and testing of LT switch gear control panel board 440 volt AC 3 phase 4 wire for out door installation "KIOSK TYPE" fabricated out of steel sections i.e CRCA sheet 3.15 mm thick , angle / channel and flat iron sections of suitable size with opening on front, and back door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard, with phosphatised powder coating painting externally and internally to protect against corrosion: The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, complete duly incorporated with following accessories: -
BMMJ TRADERS AND ENGINEERS
SATISH AND CO
SHREE KRISHANA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .