Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.0 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹23.7 L+₹3.0 L (14.4%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹24.9 L+₹4.2 L (20.0%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹27.4 L+₹6.7 L (32.1%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹28.6 L+₹7.8 L (37.8%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
28 Apr 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR / MAINT OF DG SET, BATTERY BANK, DBs, SUBMAIN WIRING, METER BOXES, SERVICE CABLES AND EARTHING SYSTEM OF LIGHTENING CONDUCTOR, ARRESTOR, BLDG AND ALLIED ITEMS AT SUNJUWAN, BALIDAN STAMBH, SAINIK ARAM GRAH UNDER GE JAMMU
2022_MES_516018_1
GEJC-01/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
200 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹56,000
Yes
8 Jul 2022
1 Apr 2022
30 Apr 2022
1 Apr 2022
28 Apr 2022
16 Apr 2022
Amount
Comprehensive maintenance consisting of normal repairs with periodical routine maintenance and testing of DG set complete of following as per manufacturer's instruction through authorised workshop / agency as approved by GE for the following DG sets (i.e. Engine, alternator, radiator, battery and control wiring etc all including consumables like cotton waste cloth, kerosine oil etc.) Maintenance will be carried out as under: - (i) Examine suction and exhaust valves in regard smooth operation. (ii) Examine and clean fuel injection, nozzles. (iii) Check clearance of suction and exhaust valves and adjust if required. (iv) Changing of oil filters, fuel filters, screen filters assembly. (v) Changing of DCA water filter. (vi) Labour charge for coolant top up. (vii) Change of Hydraulic governor oil. (viii) Change of anerold oil. (ix) Clean alternator winding in position by pressurised air and internal surfaces lubrication of DE and NDE bearings. (x) Tightening of all nut bolts. (xi) Greasing of all points. (xii) Test IR value of alternator winding and recording the readings. (xiii) Checking of any leaking in fuel and oil lines. (xiv) Cleaning of any fuel tank by removing any dirt / foreign particles. Note 1: - DHPP (N) required at the time of maintenance / testing will be issued by MES. Note 2: - Labour charges for dismantling / taking down and replacement / fixing new parts as and when required is deemed to be included the rate quoted by the contractor. Note 3: - Spare parts like oil filter, fuel filter, Air flter etc. will be measured and paid separately.
Description same as per Ser Item No 1.00 here-in-before but of capacity upto 40 KVA complete all as specified and as directed.
Description same as per Ser Item No 1.00 here-in-before but of capacity above 40 KVA to 100 KVA complete all as specified and as directed.
Description same as per Ser Item No 1.00 here-in-before but of capacity above 100 KVA to 250 KVA complete all as specified and as directed.
Supply only fuel filter primary element with 'O' ring set as required at site for upto 40 KVA capacities of DG sets complete all as specified and as directed.
Description same as per Ser Item No 2.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 2.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only fuel filter secondary element with 'O' ring set as required at site for upto 40 KVA capacities of DG set complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only lubricant oil filter with 'O' ring set as required at site for upto 40 KVA capacities of DG set complete all as specified and as directed.
Description same as per Ser Item No 4.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 4.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only air cleaner element as required at site for upto 40 KVA capacities of DG set complete all as specified and as directed.
Description same as per Ser Item No 5.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 5.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only fan belt set for radiator, alternator and water pump etc as required at site for upto 40 KVA capacities of DG sets complete all as specified and as directed.
Description same as per Ser Item No 6.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 2.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only rubber hose pipe for radiator, water pump with set and MS clamps of suitable size as required at site for upto 40 KVA capacities of DG sets complete all as specified and as directed.
Description same as per Ser Item No 7.00 here-in-before but for capacity above 40 KVA to 100 KVA DG set complete all as specified and as directed.
Description same as per Ser Item No 7.00 here-in-before but for capacity above 100 KVA to 250 KVA DG set complete all as specified and as directed.
Supply only battery lead copper heavy duty having length 1.5 metre each complete with one side banjo bolt and other side brass battery terminal bolt type set of 2 pieces complete all as specified and as directed.
Repair / servicing of self starter 12 volts DC complete with and including replacement of burnt / unserviceable spare parts, clutch assembly, carbon brush, solenoid switch, plunger, armature and refixing for DG set 10 KVA to 160 KVA complete all as specified and as directed.
Dismantling / repair / overhauling of water pump assembly of DG set upto 160 KVA by replacing defective parts like pump, shaft, impeller CI, mechanical seal, water set gaskit, hub for pulley, set screw, bearing grooves nuts, spacers and spring washer and metling / machine work if any and refixing after repair complete all as specified and as directed.
Dismantling / repair / overhauling of charging alternator (dynamo) of DG set having capacity of 10 KVA to 160 KVA and replacement of unserviceable / defective parts like carbon brushes, bearing, leaver, pulley, spacer, commutator assembly, armature, washer etc. and refitting after repair complete all as specified and as directed.
Material and labour for lubricant oil SAE 15 W - 40 for Top up and filling up the oil in the sump (tank) after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling complete all as specified and as directed.
Dismantling / taking down radiator assembly for repair / servicing of DG set 25 KVA to 160 KVA and carry out complete internal cleaning, brazzing to tubing and rectification of leakage and refitting including replacement of minor spare parts like inlet / outlet rubber hose with MS clamps, pipe for thermostat to radiator washer, nut, bolts complete all as specified and as directed.
Disconnecting the existing battery of capacity 12 V, 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function complete all as specified and as directed.
Disconnecting the existing battery of capacity 12 V, 90 AH to 150 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function complete all as specified and as directed.
Disconnecting FIP pump of DG set of following capacity and carry out complete servicing / calliberation from authorised service centre and refitting after calliberation including replacement of injector nozzle, delivery valves, gaskit, fuel pump gear, flange assembly, plunger, copper washer, adaptor, set both etc. as required to make the FIP serviceable complete all as specified and as directed.
DG set capacity 10 KVA to 63 KVA complete all as specified and as directed.
DG set capacity 70 KVA to 160 KVA complete all as specified and as directed.
Supply and fixing in repair self starter 12 Volts, 180 AH heavy duty suitable for DG set 10 KVA to 63 KVA complete all as specified and as directed.
Supply and fixing in repair self starter 24 Volts, 180 AH heavy duty suitable for DG set 63 KVA to 250 KVA complete all as specified and as directed.
Supply and fixing in replacement of battery charger heavy duty, 180 AH, 9 to 24 Volts with lead, Volt / Amp meter complete all as specified and as directed.
Supply and fixing in replacement set of high pressure of fuel pipe of engine complete nut, set volt, clamp and spring washer etc complete all as specified and as directed.
Supply and fixing in replacement of oil sump gaskit complete all as specified and as directed.
Supply and fixing in replacement of water temp switch suitable for DG set 25 KVA to 160 KVA complete all as specified and as directed.
Supply and fixing in replacement of AVR suitable for DG set 25 KVA to 160 KVA complete all as specified and as directed.
Supply and fixing in replacement Digital parameter generator set control panel as per existing make for DG set 25 KVA to 63 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of diode and rectifier for alternator suitable for DG set 25 KVA to 160 KVA complete all as specified and as directed.
Supply and fixing in replacement of onload change over switch open execution type 4 pole 415 Volts 200 Amp conforming to IS with front operated handle complete with fixing in existing LT Panel complete all as specified and as directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 Volts 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement complete all as specified and as directed.
Supply and fixing in replacement Alternator fly wheel ring for DG set capacity 25 to 63 KVA complete with disconnecting alternator from the engine and for replacement of fly wheel complete all as specified and as directed.
Supply and fixing in replacement Alternator fly wheel ring for DG set capacity 70 to 250 KVA complete with disconnecting alternator from the engine and for replacement of fly wheel complete all as specified and as directed.
Labour for Dismantling to alternator from the engine of capacity 25 KVA to 250 KVA by opening nut and bolt and transport to workshop for repair / maint and rewinding with super enamelled heat resistant copper winding wire of existing size and no's of turn complete with insulating material i.e. varnishing, bamboo strips, cotton thread / tape, leather paper etc and drying the winding complete with checking, realignment, welding, grinding, earth work and polishing the alternator rotor shaft and refitting the alternator with engine after repair / rewinding and testing on full load complete all as specified and as directed. Note: - Copper winding wire will be measured and paid separately.
Material and labour for Rewinding coil of alternator 25 KVA to 160 KVA with super enamelled heat resistant copper winding wire of existing size and no of turn conforming to ISI complete all as specified and as directed.
Material and labour for replacement of unserviceable ball bearing of alternator heavy duty conforming to ISI suitable for DG set alternator 25 KVA to 160 KVA complete all as specified and as directed.
Material and labour for replacement of unserviceable speed controller with auto cut sensor unit for DG set capacity 40 KVA to 100 KVA complete as specified and as directed.
Dismantling all incoming / outgoing electric connection carefully of transformer, voltage stabilizer, LT panel, switch, change over etc and repair the cable, fixed properly with proper aluminium thimble / lugs including preparation of cable end for jointing (incoming / outgoing cable connection for each cable will be measured as one job each). Replacement of Thimbles / Lugs rates are deemed to be included in above jobs.
Material and labour for refixing at said location with replacement of below mentioned items including connecting the MCCB's bus bars with suitable size of PVC insulated copper cable, copper lugs, cable gland, bolts, nuts and washers, phase terminals etc. complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection suitable thimble should be used as per site situation.
Supply and fixing in replacement MCCB 4 pole 250 A, breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type adjustable thermal and adjustable magnetic setting, lcs=75% of lcu).
Supply and fixing in replacement unserviceable indicators LED set of three pieces as per existing size and sample completed all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement copper wound CT 100/5-03 No's complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement ampere meter digital type 0-200 / 0 to 400, 0 to 600, 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement volt meter digital type 0-500 Volt, 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of old burnt out aluminium bus bar and connected link bar with proper colour coating with insulation tape of current rating 630 / 400 Amps including replacement of old rusted nut and bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of unserviceable batteries 12 Volt 180 AH heavy duty conforming to ISI complete with initial charging and battery lead set of 2 pieces having length of 1.5 metre each complete with one side banjo bolt and other side battery terminal bolt type complete all as specified and as directed.
Supply and fixing in replacement battery bank for 30 Volt DC supply having 16 No's sealed maintenance free batteries each battery of capacity 2 Volt and 200 AH at C / 10 with steel rack / case complete all as specified and as directed by Engineer-in-Charge.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 70 Sq mm 3½ core with necessary aluminium lugs / thimble as required at site to connect the cables to equipment and panels complete all as specified and as directed.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 Sq mm 3½ core with necessary aluminium lugs / thimble as required at site to connect the cables to equipment and panels complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep any type of soil getting out and levelling of bottom surface to required level for poles / stay assembly / cable complete all as specified and as directed.
Material and labour for road cutting, PCC hard standing with width 0.4 and depth 0.9 metre including excavation for laying of GI pipe and making good the disturbed surface complete all as per existing surface all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25m thick complete all as specified and as directed.
Removing excavated material from site to a distance not exceeding 50 metre away and depositing where directed not exceeding 1.5 metre from the starting point complete all as specified and as directed.
Material and labour in replacment of GI pipe light grade 40 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Supply and fixing in replacement for sub class 'B' bricks well burnt laid with length perpendicular to the axis of the cable in trenches for protection to cable complete all as specified and as directed.
Supplying and laying in trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level all as specified and as directed.
Taking out / down unserviceable, defective cable any type / size including disconnecting all the electrical connections all as required at site and all as specified and as directed.
Taking out existing unserviceable / old steel / mild steel angle iron frame of any size from the wall by dismantling bricks and making the surface good complete with brick works, plaster, white wash, patch work matching with existing colour all as specified and as directed.
Supply and fixing in replacement for meter board for housing electric meter with transparent lid tampered proof with suitable locking arrangements including removing existing serviceable electric meter from the panel board after disconnecting all incoming / outgoing connection carefully and refixing the same in position all as specified and as directed by Engineer-in-Charge.
Taking down old and unserviceable submain wiring any size of two core and including earth wire complete including batten / conduit any type (concealed / surface) and making good the disturbed surface to match the existing surface complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement PVC flat serviceable cable 10 Sqmm 2 core multistranded conductor 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Supply and laying in trenches, fixing or passing through pipe, fixed to wall / pole, connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 Sqmm, 4 core, complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and laying in trenches, fixing or passing through pipe, fixed to wall / pole, connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 Sqmm, 3.5 core, complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and laying in trenches, fixing or passing through pipe, fixed to wall / pole, connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 35 Sqmm, 3.5 core, complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Taking down old and unserviceable, distribution board SPN, TPN of any type including fuses, MCCB's etc after removing all connection and making good the disturbed surface all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement distribution board sheet metal enclosure steel phosphatised powder coated for MCB with copper busbar and neutral link earthing stud SPN 12 way 240 Volts double door flush to wall fitted complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board sheet metal enclosoure steel phosphatised powder coated for MCB with copper busbar and neutral link earthing stud SPN 8 way 240 Volts double door flush to wall fitted complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board sheet steel phosphatised powder coated for MCB with copper busbar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board double door sheet steel phosphatised powder painted for MCB / DB with copper busbar and neutral link earthing stud TPN 4 way 415 Volts double door complete all as specified and as directed.
Material and labour for replacement distribution board double door sheet steel phosphatised powder painted for MCB / DB with copper busbar and neutral link earthing stud TPN 6 way 415 volts double door complete all as specified and as directed.
Supply and fixing in replacement TP&N vertical load line double door DB with 200 Amps bus bar, 415 Volt sheet metal enclosure suitable for 'G' frame MCCB, 4 way complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps, 10KA complete all as specified and as directed.
Supply and fixing in replacement Isolator 4 Pole, TPN 415 Volts, 100 Amps rating with rupturing capacity 10 KA complete all as specified and as directed.
Supply and fixing in replacement for MCB TP&N 63 Amps 415 Volts, 'B' series rupturing capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement for MCB SP 6 to 32 Amps, 240 Volt 'B' series complete all as specified and as directed.
Supply and fixing in replacement for MCB SPN 40 Amps 240 Volts, 'B' series complete all as specified and as directed.
Supply and fixing in replacement for MCB SPN 63 Amps 240 Volts, 'B' series complete all as specified and as directed.
Material and labour in replacement for submain wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through existing PVC concealed conduit fixed on wall complete all as specified and as directed. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for submain wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through existing PVC concealed conduit fixed on wall complete all as specified and as directed. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for earthing complete with galvanized steel plate earth electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 1.5 metre below normal ground level connected to galvanized iron wire of 4 mm dia earth lead by means of bolts, nuts and washers made of galvanized iron protected by 40mm bore light grade GI pipe up 7.5 Rm with 4mm earth lead and connected for body earthing of feeder pillar box all as specified and including PCC (1:3:6) type C-2 pit and precast RCC (1:11 / 2:3) type A-1 pit cover slab of size 300 x 300 x 50mm with handle as shown in drawing funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work and excavation in hard / dense soil and removal etc complete all as specified in electrical plate No 3 of SSR Part - I 2020 and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC enclosure DP complete with MCB SPN 32 Amp, 10 KA, 230 Volt complete all as specified and as directed.
Supply and fixing in replacement of sheet steel cable and box (busbar) 4 way 440 Volt, 50 Hz single door with 200 Amp rated busbar mounted on insulator complete all as specified and as directed.
Material and labour for testing of old earthing using calibrated earth tester and submitting result to Engineer-in-Charge. Earthing which showing much more results as specified in IS rule and disconnectivity should be replaced with new earthing items are considered as below complete all as specified and as directed. Note: - (i) Watering of earthing with 2 Buckets (30 litres) water mixed with salt (total 5 Kg) shall be carried out one day before the testing and the cost of the same shall deemed to be included in unit rate quoted.
Dismantling / taking down old existing unserviceable lightening conductors and Material and labour / fixing for lightening conductor assembly made out of GI pipe medium grade of size 40 mm bore alongwith welded flange at one end and GI reducer socket to connect epoxy insulators of suitable size of air termination and connector for earth strip duly fixed with necessary nuts, bolts and washers in PCC (1:2:4) type B-0 30cm x 30cm x 30cm complete all as specified and as directed. Note: - GI pipe 40mm and air temination shall be measured and paid separately under relevant items.
Supply and fixing in replacement GI pipe medium grade of size 40 mm bore with all fittings for erection of lightening conductor complete as required all as specified and as directed.
Supply and fixing in replacement air termination Aluminium rod 20mm dia, 300 mm long for lightening conductor with epoxy insulators of suitable size of air termination complete all as specified and as directed.
Supply and fixing in replacement air termination copper rod 12mm dia, 300 mm long for lightening conductor with epoxy insulators of suitable size of air termination complete all as specified and as directed.
Dismantling of existing copper / aluminium earthing / lightening conductor strip from wall / roof of building and refixing on porcelain insulators after grouting insulators on wall / roof with neccesory fixing arrangement (nuts, bolts and PCC work) complete all as specified and as directed.
Material and labour for new earthing complete with copper plate earth electrode 600 X 600 X 3.15mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to 20 x 3mm copper strip at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard / dense soil, returning, filling in and removal of surplus soil to a distance upto 50 metres, PCC pit in (1:3:6) type C-1 (using 20mm grade crushed stone aggregate), RCC (1:2:4) type B-1 (using 20mm grade crushed stone aggregate) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm centre to centre, both ways mild steel handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) including taking down old one all as specified and as directedand shown in electrical plate No 3 of SSR Part-I including testing on completion. Note: - Copper strip and protection pipes 40 mm GI light grade upto 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Material and labour for new earthing complete with galvanised steel plate earth electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25 X 4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard / dense soil, returning, filling in and removal of surplus soil to a distance upto 50 metres, PCC pit in (1:3:6) type C-1 (using 20mm grade crushed stone aggregate), RCC (1:2:4) type B-1 (using 20mm grade crushed stone aggregate) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm centre to centre, both ways mild steel handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) including taking down old one all as specified and as directed and shown in electrical plate No 3 of SSR Part-I including testing on completion. Note: - GI strip and protection pipes 40 mm GI light grade upto 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Material and labour for new earthing complete with galvanised steel plate earth electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI wire 4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard / dense soil, returning, filling in and removal of surplus soil to a distance upto 50 metres, PCC pit in (1:3:6) type C-1 (using 20mm graded crushed stone aggregate), RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm centre to centre, both ways mild steel handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 20mm bore (light grade) including taking down old one all as specified and as directed and shown in electrical plate No 3 of SSR Part-I including testing on completion. Note: - GI strip and protection pipes 20 mm GI light grade upto 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Supply and fixing in replacement for copper strip 20 x 3.15 mm on wall / batten or recessed with replacement of porcelain insulators, mild steel saddle / clamp, fixing screws etc for roof conductor and down conductor above ground and on wall or buried in ground complete all as specified and as directed.
Supply and fixing in replacement for aluminium strip 25 x 3.15 mm on wall / batten or recessed with replacement of porcelain insulators, mild steel saddle / clamp, fixing screws etc for roof conductor and down conductor above ground and on wall or buried in ground complete all as specified and as directed.
Supply and fixing in replacement for GI strip 25 x 4 mm on wall / batten or recessed with replacement of porcelain insulators, mild steel saddle / clamp, fixing screws etc for roof conductor and down conductor above ground and on wall or buried in ground complete all as specified and as directed.
Supply and fixing in replacement for GI wire 4 mm on wall / batten or recessed or buried in ground complete all as specified and as directed.
Dismantling / Taking down and supply, installation, testing and commissioning of LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 no's LED are provided AC circuit, 230 Volts with all components and fixing arrangements on pipe necessary flat iron clamps, nuts, bolts and washers etc including necessary wiring circuit complete all as specified and as directed.
Dismantling / Taking down and supply and fixing 2 core 2.5 Sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 Volts grade including PVC conduit on pole, wall etc with mild steel clamps all as specified and as directed.
Supply and fixing in replacement test point terminal block made out of GI strip 32 X 6 mm as per site requirement complete with fixing mild steel clamp, nut, bolt complete all as specified and as directed.
Labour for repair to existing unserviceable / loose / hanging GI or aluminium earth strip fix on and around the RCC reservoir complete with and including porcelain insulators, mild steel saddle / clamps, nut, bolt, screws as per site requirement and fix the strip properly with RCC reservoir wall complete all as specified and as directed. Note: - Rates are deemed to be including charges for hiring T&P and life insurance of person deployed at site.
Material and labour for replacement of tubing GI "medium grade" with all fittings laid in floors or trenches including taking out old unserviceable pipe of size 15 mm dia complete all as specified and as directed.
Supply and fixing in replacement gun metal globe / gate valve 15 mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and as directed.
Material and labour for cutting to existing GI pipe line of any size in position for addition, alteration / for branch connection or insertion of tee complete with including GI fittings for jointing branch connection, threading, earthwork as per site requirement all as specified and directed.
Material and labour for replacement of syntex tank double layer 250 litre complete with float valve complete all as specified and as directed.
Bidder Name
Prakash Trading Corporation
G R CONSTRUCTIONS
Sarbat Construction Co
M/S Bali Agencies
M/S SALARIA ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .