| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.6 LAccepted-Finance 97 RAJA RAMMOHAN ROY ROAD SIRITY KOLKATA WEST BENGAL 700041 WB10A0004871 | KOLKATA | WEST BENGAL | 700041 | ₹61.6 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹73.3 LRejected-Finance 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | ₹73.3 L | L2 | Rejected-Finance The bidder rate is high |
| 3 | L3₹65.4 LRejected-Finance KAWAKHALJ SUSHRUTANAGAR MATIGARA PIN 734012 | MATIGARA | DARJEELING | WEST BENGAL | 734012 | ₹65.4 L | L3 | Rejected-Finance The bidder rate is high |
| 4 | Rejected-Technical 0 BETTER POWER SERVICES PVT LTD A K AZAD ROAD REHABARI KAMRUP ASSAM 781008 UDYAM AS 03 0002019 19AADCB7283J1Z9 B 29AADCB7283J1Z8 B 18AADCB7283J3Z9 M 16AADCB7283J1ZF B 18AADCB7283J3Z9 B R MII STATUS AS VERIFIED | KAMRUP METRO | ASSAM | 781008 | - | - | Rejected-Technical technically not accepted |
| Sl No | Description | Qty | Unit | switching avo Electro Power Ltd L1 | Shiv Shakti Construction L2 | BIKASH ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of 10 KVA UPS including Battery Bank of not less than 12480 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation. | 22 | Set | 1,77,604 ₹39,07,288 | 1,85,000 ₹40,70,000 | 2,11,540 ₹46,53,880 |
| 1.01Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. | ||||||
| 2.00 | SITC of 15 KVA UPS including Battery Bank of not less than 19200 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation. | 4 | Set | 2,79,448 ₹11,17,792 | 2,90,000 ₹11,60,000 | 3,24,245 ₹12,96,980 |
| 2.01Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. Certificate | ||||||
| 3.00 | SITC of 20 KVA UPS including Battery Bank of not less than 23049 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation. | 3 | Set | 3,16,842 ₹9,50,526 | 3,60,000 ₹10,80,000 | 4,19,956 ₹12,59,868 |
| 3.01Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. | ||||||
| 4.00Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required | ||||||
| 4.01 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC | 60 | Mtr | 1,370 ₹82,200 | 355 ₹21,300 | 795 ₹47,700 |
| 4.02 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC | 60 | Mtr | 860 ₹51,600 | 330 ₹19,800 | 590 ₹35,400 |
| 4.03 | 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC | 60 | Mtr | 528 ₹31,680 | 235 ₹14,100 | 376 ₹22,560 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
18 Dec 2025, 3:00 pmClosed
EE II CKHED
P12 CIT Road 1st floor Kol 14
Supply, installation, Testing and Comissioning of silent type Diesel Generator Sets and UPS of different capacity, including allied Electrical works for providing emer power supply to diff sensitives loads at different building of NRS mch SITC of UPS
2025_WBPWD_955626_1
WBPWD/EE-II/CKHED/ eNIT-71/25-26
Open Tender
ELECTRICAL WORKS ORG
90 days
NRS MCH
as per NIT
4 documents required · 4 mandatory
₹1.4 L
central kolkata health electrical division
10 Feb 2026
21 Nov 2025
22 Dec 2025
21 Nov 2025
18 Dec 2025
27 Nov 2025
26 Nov 2025
SITC of 10 KVA UPS including Battery Bank of not less than 12480 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects.
SITC of 15 KVA UPS including Battery Bank of not less than 19200 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. Certificate
SITC of 20 KVA UPS including Battery Bank of not less than 23049 VAH or higher (SMF Battery 12 Volt, not less than 45AH ) 3ph Input & 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 95% efficiency on 100% Load. For active input P.F. Correction system to obtain minimum 0.95 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Better Power/ Delta) Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
25mm size
Terms and Condition: The Agency mlist procure the materials from the Manufacturer/ OEM or from their authorised sales channel so that the standard warranty/ support of the Manufacturer/ OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticate such procurement from the Manufacturer/ OEM or from their authorized sales channel and standard warranty/ support should be sent from the e-mail of the Manufacturer/ OEM/ authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
Rate should be quoted incl. of all taxes and cess. (GST @18%)
Defect Liability period : 1 year
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
revised2911.pdf
Tender Documents • 0.50 MB
BOQ_2293331.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid