| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.8 L+₹1.6 L (3.36%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹50.0 L+₹1.8 L (3.83%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹50.6 L+₹2.4 L (5.06%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹50.9 L+₹2.8 L (5.73%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Jan 2023, 6:00 pmClosed
GE Minnie bay
GE Minnie bay junglighat Post Minniebay Port Blair 744103
REPAIR/MAINT OF STREET LIGHT FITTINGS LT PANELS LT CABLES MCCB AND EXTERNAL LT WORKS AT BROOKSHABAD AND VAHU VIHAR UNDER AGE EM II AT GE MINNIE BAY
2023_MES_574253_1
8209/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE Minniebay
₹90,000
Yes
4 Mar 2023
10 Jan 2023
2 Feb 2023
11 Jan 2023
31 Jan 2023
25 Jan 2023
Amount
S&F in repairs aluminium cables lugs for cables of size upto 10Sqmm including necessary crimping with crimping tool complete all as specified and directed by Engr-in-Charge
All as per item No 01.00 above but size upto 16 Sqmm
All as per item No 01.00 above but size upto 25 Sqmm
All as per item No 01.00 above but size upto 35 Sqmm
All as per item No 01.00 above but size upto 50 Sqmmm
All as per item No 01.00 above but size upto 70 Sqmmm
All as per item No 01.00 above but size upto 95 Sqmmm
All as per item No 01.00 above but size upto 125 Sqmmm
All as per item No 01.00 above but size upto 185 Sqmmm
All as per item No 01.00 above but size upto 240 Sqmmm
All as per item No 01.00 above but size upto 300 Sqmmm
All as per item No 01.00 above but copper lugs of size upto 25 Sqmm
All as per item No 01.00 above but copper lugs of size upto 35 Sqmm
All as per item No 01.00 above but copper lugs of size upto 50 Sqmm
All as per item No 01.00 above but copper lugs of size upto 70 Sqmm
S&F in replacement of on load change over switch 415 V, 4 pole, 125A complete all as specified and directed by Engr-in-Charge
S&F in replacement of on load change over switch 415 V, 4 pole, 160A complete all as specified and directed by Engr-in-Charge
S&F in replacement of on load change over switch 415 V, 4 pole, 200A complete all as specified and directed by Engr-in-Charge
S&F in replacement of on load change over switch 415 V, 4 pole, 250A complete all as specified and directed by Engr-in-Charge
S&F in replacement of on load change over switch 415 V, 4 pole, 320A complete all as specified and directed by Engr-in-Charge
S&F in replacement of on load change over switch 415 V, 4 pole, 400A complete all as specified and directed by Engr-in-Charge
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 200A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 250A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 320A complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 400A complete all as specified and directed by Engr-in-Charge.
Supply and fixing as in repair of MCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of MCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of MCB 40 Amps, TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of MCB 63 Amps,double pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of MCB 32 Amps,double pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of MCB 63 Amps,single pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
M&L in repair for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of following size :- Note : Taking down the fault cable, excavation, returning filling, removal of surplus soil shall be measured and paid separately under relevant item of this schedule.
16 to 25 Sqmm 3.5 core
35 to 70 Sqmm 3.5 core
95 to 150 Sqmm 3.5 core
185 to 240 Sqmm 3.5 core
300 to 40 Sqmm 3.5 core
Supply and laying in replacement of GI tubing ISI marked light grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position including fittings of following size all as specified and directed:-
100mm dia
80mm dia
50mm dia
40mm dia
Supply and laying in replacement of LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes all as specified and directed :- Note : Taking down the fault cable, excavation, returning filling, removal of surplus soil shall be measured and paid separately under relevant item of this schedule.
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
25 Sqmm 4 Core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement of DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc. with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge.
All as per item No 39.00 above but outer dia of 63 mm and inner dia 50 mm.
All as per item No 39.00 above but outer dia of 77 mm and inner dia 63 mm.
All as per item No 39.00 above but outer dia of 90 mm and inner dia 76 mm .
All as per item No 39.00 above but outer dia of 110 mm and inner dia 95 mm.
All as per item No 39.00 above but outer dia of 120 mm and inner dia 103.5 mm.
All as per item No 39.00 above but outer dia of 160mm and inner dia 126 mm.
Excavation in soft / loose soil not exceeding 1.5m wide and n exc 1.5m depth and getting out incl forming of bottom for laying cable complete all as specified and as directed by Engineer-in-Charge.
Excavation in hard / dense soil including road cutting etc not exceeding 1.5m wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable complete all as specified and as directed by Engineer-in-Charge.
Returning filling in using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting LT supply and taking out defective LT draw out EDO type ACB 440 V 800Amp / 630Amp and servicing by OEM .i.e Authorised dealer cleaning the fixed and moving all parts, removing dust particles by using high speed blower applying grease/jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and complete testing and putting on full load all as specified and as directed by Engr-in-Charge Note: Necessary document reguarding service from OEM such as GST Service voucher, gate pass etc shall be submitted by the contractor while submitting RAR/FB for payment.
S&F in replacement of isolating JAW contacts suitable for 800Amp / 630Amp LT draw out EDO type ACB complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of polyester resin cast CT 800 / 5A suitable for 800Amp /630Amp LT draw out EDO type ACB complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of ARC Chutes for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Pole Unit for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Draw out terminals for Air circuit breakers EDO type suitable for 800/630 Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Lower terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Upper terminals for Air circuit brekers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Charging motor for Air circuit brekers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of shunt trip and closing coil for Air circuit brekers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of manual Charging handle for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of under voltage trip device compact with UVT coil for Air circuit breakers EDO type suitable for 800Amp/ 630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Safety shutter assembly for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Earth fault relay with NCT for Air circuit brekers EDO type suitable for 800/630 Amp complete all as specified and directed by Engr-in-Charge
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required,complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of digital soft starter suitable for 15 HP submersible pump complete all as specified and directed by Engr-in-Charge.
S & F in replacement of star delta starter suaitable for 10 to 12.5 HP submersible pump with proper electrical connection including additional wiring etc complete all as specified and as directed by Engineer-in-Charge.
M & L for repair of LT Panel board outdoor type such as replacement damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding & drilling hole etc.works required at site complete all as specified and as directed by Engineer-in-Charge.
M&L for providing plain cement concrete type B-1, 1:2:4 nominal mix using 20mm graded aggregate as in coping, benching, and similar works slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed by Engineer-in-Charge.
M&L for finding out cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detetor machine complete all as specified and as directed by Engineer-in-Charge. Note: Necessary documents for hiring / renting voucher of cable fault finder shall be produced to GE for payment prupose duly signed by Eng-in-charge
S&F in replacement of heavy duty resin filled capacitor 440 volt, 3 Ph of capacity upto 30 KVAR including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of APFC Controller upto 5 Step including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of digital Volt meter (0-500) including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of digital ammeter including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Indicating Lamp R. Y. B (LED) type including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of CTs of 50/5 rating including connections and testing for proper functioning complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old surfaces and spray painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with one coats of aluminium paint complete all as specified and as directed by Engr-in-Charge
M&L for Notice board 6 feet by 4 feet using half mm thick foam sheet including writing of DG set/ transformer/ AC plant/pumps details as per given formed and shall be print in blue color only and letters are white color minimum 76 letters and maximum 90 letters and fixing with rivet or screw including taking down old existing board from site, before placing order / execution a sample board shall be collect from site JE E/M with details complete all as specified and as directed by Engineer-in-Charge.
M&L for Notice board 4 feet by 3 feet using half mm thick foam sheet including writing of particular details of E/M installations and shall be printed in blue color only and letters are white color minimum 50 letters and maximum 70 letters and fixing with rivet or screw including taking down old existing board from site, before placing order / execution a sample board shall be collect from site JE E/M with details complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PCC cable route indicator of size 0.75MX0.20MX60mm including writing of cable size and location complete all as specified and as directed by Engineer-in-Charge. Note: Necessary Excavation and PCC work for fixing of cable route indicator is included in the quoted rate.
S & F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figure and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed.
Supply and laying stone aggregate of 40 mm size in 75 mm thickness underneath of 4 pole/ 2 pole structure / transformer yard all as diected.
Supply & Installation in replacement of 4 inch thick ACP Box of size 6 feet x 4 feet with MS pipe structure fix inside with 3 mm Acrylic sheet with digitally printed 3Mtr backelite Vinyl on HP Latex Printer, Display both side, LED modules complete upto 100 letters as specified size directed by Engr-in-Charge with Andaman & Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty 50 mm bore up to 3Mtr height by nuts/bolts and welding as required at site , spray painting with two coat synthetic enamel paint comlete MS pipe including necessary excavation and PCC work for foundation of MS poles as directed at site complete all as specified and direced by Engr-in-Charge
Supply & Installation in replacement of of 4 inch thick ACP Box of size 12 feet x 4 feet with MS pipe structure fix inside with 3 mm Acrylic sheet with digitally printed 3Mtr backelite Vinyl on HP Latex Printer, Display both side, LED modules complete upto 100 letters as specified size directed by Engr-in-Charge with Andaman & Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty 50 mm bore up to 6Mtr height by nuts/bolts and welding as required at site , spray painting with two coat synthetic enamel paint comlete MS pipe including necessary excavation and PCC work for foundation of MS poles as directed at site complete all as specified and direced by Engr-in-Charge
Supply and fix earth pit chamber board 3.15 mm thick mild steel sheet of size 45 cm x 45cm x 45 cm fixed with 12 mm thick mild steel rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete mild steel sheet both side including writing letters 6 cm height i.e. Earth Pit No, Location, Earthing test value and date complete all as directed by Engr-in-Charge
Supply and fix in replacement of street light timer digital type 240V AC 50 Hz type FMD 120 complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of contactor ML- 4, 70 Amps power operating voltages 415 V AC complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of contactor ML-3, 40 Amps Power operating voltages 415 V AC complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement LED driver 12 to 20 Watt 240V AC 50 Hz for street light/flood light/high bay light complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement LED driver 25 to 40 Watt 240V AC 50 Hz for street light/flood light/high bay light complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement LED driver 45 to 75 Watt 240V AC 50 Hz for street light/flood light/high bay complete all as specified and as directed by Engr-in-Charge
Supply & Fix in replacement surge protection device (SPDs) for street light/flood light surger protection rating up to 5 KV complete all as specified and as directed by Engr-in-Charge
S & F in replacement of on load change over switch 415 V, 4 pole, 100 A complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCCB, 415 volts, 4 pole 25 KA, 63 A complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB, 415 volts, TPN 10 KA, 63A/ 40A complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB, 220 volts, DP 10 KA, 63A/40A/32A complete all as specified and as directed by Engr-in-Charge
Supply only MCB SP 6 to 32 Amps, 220V, 10KA 'C' Curve complete all as specified and as directed by Engr-in-Charge
Supply only MCB SP 40 to 63 Amps, 220V, 10KA 'C' Curve complete all as specified and as directed by Engr-in-Charge
Cutting of road/pavement/hard standing or any other situation by manual mean for passing GI pipe 50mm bore grade and making good both the ends all as specified and directed by Engineer in Charge. Note: - Cost of GI pipe will be paid separately.
Demolition of cement concrete in ground floors and paving built in cement concrete (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed
M&L for Plain Cement Concrete 1:2:4 type B-1(Nominal mix) using 20mm grade stone aggregate as in coping of poles including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and as directed
M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation for stay assy, repairing of floor/paths, fencing post road cuts etc including necessary form work and fair finshing to exposed surface without using extra cement complete all as specified and as directed
M&L for Sub main wiring complete with 2x2.5 sqmm , single core , multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along street light pole / walls roofs etc including 2.5 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly including making of good distrubed surface complete all as specified and as directed by Engineer-in-charge. Note:- (i) All three runs of cable(phase, neutral and earth) should be run throught for each individual circuit from the DBs/junction boxs to light fittings. (ii) Two run of cable and one run of earth conductor shall be measured and paid as one unit run.
S&F in replacement 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart or fixing on wall with saddeles and screws all as directed and as per site requirement, of size 6 sqmm, twin core flat or circular complete all as specified and as directed
M&L for preparation of old street light poles by scraping, cleaning of old surfaces of the existing street light tubular / HDG poles of size upto 11 mtr long above ground level including brackets etc and painting with one coat of aluminium paint on complete pole and brackets including marking 30 cm strips on pole in black and yellow colour paint upto 2.1m height from the pedestal including write number on pole as specified and directed
M&L for preparation of old high mast light poles by scraping, cleaning of old surfaces of the existing street light tubular / HDG poles of size upto 30 mtr long above ground level including brackets, etc and paininting with one coat of aluminium paint on complete pole and bracket including marking 30 cm strips on pole in black and yellow colour paint upto 2.1m height from the pedestal including write number on pole as specified and directed
S&F in replacement cable junction box IP-55/IP-65 with metric knockout for cable entry size 210x310x116 mm with terminals including long entry thread metric (with one piece sealing ring) and fixing on pole with 32x6mm aluminium strip clamp with nuts, bolts and washers, electricals connections all as directed by Engr-in-charge.
S&F in replacement service bracket for street light fitting made out of 40/25 mm bore light graded GI pipe of length 1.50 mtr bend/weld to shape at 120 degree for fixing of street light fitting on pole all as specified and as directed by the Engineer-in-charge.
S&F in replacement of Street light fitting LED type,72 Watts 240 Volts high luminous, energy efficient not less than 100 lm/Watt , including SPD fittings and accessories complete mounted on suitable dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of smart bright Flood light fitting LED type,120 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics, reliable and sturdy, mounted on wall and providing connection complete all as specified and directed
S&F in replacement of smart bright Flood light fitting LED type,200 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light sleek and robust design for better aesthetics , reliable and sturdy, mounted on wall and providing connection complete all as specified and directed
S&F in replacement energy efficient post top light fitting on wall/gate 360 digree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed
S&F in replacement energy efficient post light (bollard light) 360 degree light distribution with IP-65 ,85.5 cm hight and 17.4 cm width fitting on ground , wall etc including excavation and PCC 300cmx300cm and high quality integerated LEDs assure soothing warm white light all night long LED 10 W black case aluminuim , synthetic model Robin including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc all as specified and directed
M&L for taking down high mast light assembly and servicing/repairing of high mast light pole upto 30m height,cleaning the glass cover in & out and the reflector with approved cleaning solution,refilling the gear oil in gear box and winch,adjusting the winch brake,tightening the anchor bolts of base plate,repairing and access door serviceable,cotter pins and fixture mounting ring all as specified and as directed by the Engineer-in-charge.
M&L for disconnecting electrically and mechanically defective induction electric motor capacity upto 5 HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enameled ,copper conductor winding wire and replacement of u/s burnt insulating materials, sleeves etc,varnishing and other connected works,re-assembling,re-fixing at site, electrical connection fixing with pump set with nuts,bolts,washers as per original position and testing complete all as directed
Material & Labour in replacement of SS Wire rope 6mm dia for high mast feeder pillar box etc complete all as directed at site.
Material & Labour for replacement of 10 Sqmm 415V 50Hz four core FRLHS copper conductor fixed with high mast light pole upto 30m height complete all as directed.
Supply and fix in replacement of single dome PVC LED aviation obstruction lights 20W 215Volt 50 Hz complete all as directed.
M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts including dismantling of fencing complete all as specified.
M&L for Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. for supporting of tanks/chainlink fencing etc as directed.
S & F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figure and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed.
M/s Power Engineering Co
ISLAND SALES ENTERPRISES
PTech Engineers
Usha Builders
DHAKSHNA MOORTHY AND SON
Ravi Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .